Plan Review Details - Permit 05021151
Plan Review Stops For Permit 05021151
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-02-24 Cont ID  
Sent By btrobaug Date 2005-02-24 Time 10:39 Rev Time 0.33
Received By btrobaug Date 2005-02-24 Time 10:19 Sent To  
Notes
2005-02-24 00:00:00 
  
 PROVISO
 ~~~~~~~
  
 PLEASE NOTE ARTICLE 230.70 CITY OF WEST
 PALM BEACH AMMENDMENTS REQUIRE A
 DISCONNECTING MEANS GROUPED WITH THE
 METER IF MORE THAN 8' OF CONDUCTORS ARE
 INSIDE THE HOUSE UNPROTECTED TO THE
 FIRST BREAKER (OVERCURRENT PROTECTION).
 IF THIS CONDITION EXISTS A DISCONNECT
 BMUST BE ADDED AND THE PLANS REVISED
 PRIOR TO INSPECTION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-22 Cont ID  
Sent By adarroug Date 2005-02-22 Time 13:46 Rev Time 0.00
Received By adarroug Date 2005-02-22 Time 13:46 Sent To E
Notes
2005-02-22 00:00:00TO "E" BOX