Plan Review Details - Permit 05020756
Plan Review Stops For Permit 05020756
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-02-19 Cont ID  
Sent By rbrown Date 2006-02-19 Time 18:51 Rev Time 0.00
Received By rbrown Date 2006-02-19 Time 18:51 Sent To  
Notes
2006-02-19 00:00:00SUBMITTAL FOR UL LISTING ON PROPOSED
 UNVENTED FIRE BOX.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-08-23 Cont ID  
Sent By rbrown Date 2005-08-22 Time 15:09 Rev Time 0.00
Received By rbrown Date 2005-08-22 Time 15:18 Sent To  
Notes
2005-08-23 00:00:00ARCHITECTURAL REVISION SUBMITTED 6/9/05
 FOR SIGNATURE DOORS ENTRY DOOR AND FIXED
 LITE LOCAL PRODUCT APPROVALS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-06-30 Cont ID  
Sent By rbrown Date 2005-06-30 Time 19:20 Rev Time 0.00
Received By rbrown Date 2005-06-30 Time 19:20 Sent To  
Notes
2005-06-30 00:00:00ARCHITECTURAL AND STRUCTURAL REVISION
 FOR SHEETS A-1 TO A-10, S-1 AND S-2

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-04-26 Cont ID  
Sent By rbrown Date 2005-04-26 Time 15:10 Rev Time 0.00
Received By rbrown Date 2005-04-25 Time 16:31 Sent To  
Notes
2005-04-25 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 --PROVISO--
 PRE-MANUFACTURED FIRE BOX.
 BEFORE INSPECTION, THE UL LISTING FOR
 THE PROPOSED FIRE BOX MUST BE CONFIRMED.
 FOR THE PROPOSED MAJESTIC FIREPLACES
 (CFM SPECIALTY HOME PRODUCTS)MODEL#
 UVSRC42A THE QUOTED UL LISTING NUMBER,
 ULMH 17022, COULD NOT BE FOUND ON THE UL
 ON-LINE CATALOG.UL WERE CONTACTED AND
 STATED THAT THE LISTING DOES EXIST.
 THIS WAS CONFIRMED BY MAJESTIC
 FIREPLACES TECHNICAL SUPPORT CONTACT,
 NEVIN (TEL: 905 670 7777 X2323) WHO
 STATED THAT THE UL RECORDS NEED TO BE
 UPDATED AND THAT UL TECHNICAL
 REPRESENTATIVE, BOB ZIMMERMAN (TEL: 847
 664 3129) WILL BE ADDRESSING THIS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-04-08 Cont ID  
Sent By rbrown Date 2005-04-08 Time 11:51 Rev Time 0.00
Received By rbrown Date 2005-04-08 Time 11:47 Sent To  
Notes
2005-04-08 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 3/8/05:
  
 1) 713.13 F.S.RESPONSE MEMO IS NOTED.
 THE CONTRACTOR WILL PROVIDE A COPY OF A
 RE-RECORDED NOTICE OF COMMENCEMENT
 BECAUSE THE DESCRIBED IMPROVEMENT DID
 NOT START WITHIN 90 DAYS OF RECORDING.
  
 3) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THIS COMMENT HAS NOT
 BEEN PROPERLY ADDRESSED.THE ADDITION
 OF A CERTIFICATE OF AUTHORIZATION NUMBER
 TO EACH PLAN SHEET IS NOTED BUT THE
 NUMBER DOES NOT CORRELATE WITH THE
 COMPANY NAME 'DAILEY JANSSEN ARCHITECTS,
 P.A.' ON THE TITLE BLOCK.A SEARCH ON
 THE DBPR WEBSITE SHOWS THAT THE COMPANY
 NAME LISTED UNDER THE STATED CERTIFICATE
 OF AUTHORIZATION NUMBER IS DAILEY &
 PARTNERS ARCHITECTS, P.A.CHANGE THE
 COMPANY NAME ON EACH TITLE BLOCK TO
 'DAILEY & PARTNERS ARCHITECTS, P.A.', OR
 REMOVE THE CERTIFICATE OF AUTHORIZATION
 NUMBER, COMPANY NAME AND COMPANY ADDRESS
 AND ADD THE ADDRESS OF ROGER P. JANSSEN
 TO EACH TITLE BLOCK (REF: 61G1-16.004
 FL. ADMIN. CODE).
  
 6) FBC 1606.1SHEET S-4, TRUSS ANCHOR
 SCHEDULE. THIS COMMENT HAS NOT BEEN
 PROPERLY ADDRESSED.IT IS NOTED THAT
 ANCHOR TYPE G IS SPECIFIED AS 'NU-VUE'
 NVUCC 223 LF.THIS ANCHOR COULD NOT BE
 FOUND ON THE STATEWIDE, MIAMI-DADE OR
 ICC-ES PRODUCT APPROVAL SEARCH WEB
 SITES.SUBMIT PRODUCT APPROVAL
 DOCUMENTS OR SPECIFY A DIFFERENT ANCHOR.
  
 12) FBC 2806.1SHEET A-2, FACTORY
 BUILT FIREPLACE.THIS COMMENT HAS NOT
 BEEN PROPERLY ADDRESSED.THE COMMENT
 RESPONSE MEMO IS NOTED, BUT THE PLAN
 STILL REFERS TO A FIRE-BOX BY 'SUPERIOR'
 WHILE THE SUBMITTED MANUFACTURERS SHEETS
 ARE FROM 'MAJESTIC'.ALSO, THE SHEETS
 MENTION A "UNIVERSAL UL LISTING" BUT
 GIVE NO SPECIFIC UL REQUIREMENTS THAT
 THE PRODUCT MEETS.PROVIDE TWO
 COPIES OF MANUFACTURERS DOCUMENTS WHICH
 SHOW THE UL TEST REPORT LISTING.
  
 15) ENTRY DOOR.SHEET A-2 SHOWS THIS AS
 AN INSWING DOOR WHILE THE SUBMITTED
 PRODUCT APPROVAL IS FOR AN OUTSWING
 DOOR.AMEND THE PLAN OR SUBMIT AN
 ALTERNATIVE PRODUCT APPROVAL.IN ANY
 EVENT, THE APPLICATION FOR LOCAL PRODUCT
 APPROVAL OF THE SIGNATURE DOOR, INC
 IMPACT, WOOD PANEL/FRENCH DOORS HAS BEEN
 APPROVED.THREE COPIES ARE ATTACHED,
 ONE FOR THE MANUFACTURER/DISTRIBUTOR AND
 TWO TO BE RE-SUBMITTED WITH THESE PLANS
 FOR PERMITTING.
  
 19) FRENCH DOORS.THE APPLICATION FOR
 LOCAL PRODUCT APPROVAL OF THE
 CONSTRUCTION GLASS INDUSTRIES CORP.
 IMPACT ALUMINUM STOREFRONT DOORS HAS
 BEEN APPROVED.THREE COPIES ARE
 ATTACHED, ONE FOR THE
 MANUFACTURER/DISTRIBUTOR AND TWO TO BE
 RE-SUBMITTED WITH THESE PLANS FOR
 PERMITTING.
  
 20) CASEMENT WINDOWS.NO PRODUCT
 APPROVAL HAS BEEN SUBMITTED FOR THE
 CASEMENT WINDOWS.THE PLANS SHALL BE
 AMENDED IF THIS WINDOW TYPE IS NO LONGER
 TO BE USED(SEE COMMENT #21).
  
 21) SINGLE HUNG WINDOWS.NO SINGLE HUNG
 WINDOWS APPEAR TO BE SHOWN ON THE PLANS.
 THE PLANS SHALL SHOW WHAT WINDOW TYPE IS
 TO BE USED (SEE COMMENT #20).THE
 SUBMITTED INNOVATIVE WINDOW CONCEPTS LLC
 STATEWIDE PRODUCT APPROVAL FL2742 DOES
 NOT HAVE AN APPROVED STATUS.SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL
 OR SPECIFY AN ALTERNATIVE THAT HAS
 STATEWIDE OR LOCAL PRODUCT APPROVAL.
  
 22) IMPACT FEE STAMP.IT IS NOTED THAT
 THE PALM BEACH COUNTY IMPACT FEE STAMP
 IS ON THE OLD TITLE/LOCATION PLAN SHEET.
 INCLUDE ONE COPY OF THIS SHEET WITH EACH
 CURRENT PLAN SET SO THAT THE IMPACT FEE
 STAMP MAY BE CONSIDERED STILL
 APPLICABLE.
  
 23) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-08 Cont ID  
Sent By rbrown Date 2005-03-08 Time 17:42 Rev Time 0.00
Received By rbrown Date 2005-03-08 Time 19:20 Sent To  
Notes
2005-03-08 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) 713.13 F.S.SUBMITTAL OF A NOTICE OF
 COMMENCEMENT IS NOTED BUT IT MUST BE
 RE-RECORDED BECAUSE THE DESCRIBED
 IMPROVEMENT OR CONSTRUCTION DID NOT
 COMMENCE WITHIN 90 DAYS OF RECORDING.
  
 2) 61G1-16.004FL. ADMIN. CODE.EACH
 SHEET OF PLANS PREPARED BY A REGISTERED
 ARCHITECT SHALL INCLUDE A TITLE BLOCK
 WHICH MUST:
 - STATE THE FIRM LICENSE NUMBER (SEE
 COMMENT #3, BELOW)
 - INCLUDE THE PRINTED NAME OF THE
 ARCHITECT SEALING THE PLANS
 THIS INFORMATION MAY BE ADDED BY HAND.
  
 3) 481.219 F.S.CERTIFICATE OF
 AUTHORIZATION.THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT
 PRACTICING UNDER A FICTITIOUS NAME, A
 CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE
 THE CERTIFICATE OF AUTHORIZATION
 NUMBER.ADD THE NUMBER TO EACH SHEET.
 THIS MAY BE ADDED BY HAND.
  
 4) 61G15-23.002(2)FL. ADMIN. CODE.IT
 IS NOTED THAT THE STRUCTURAL PLAN SHEETS
 S-1 TO S-5 HAVE BEEN SIGNED AND SEALED
 BY ALBERT A GARGIULO, P.E. BUT HIS TITLE
 BLOCK DOES NOT APPEAR ON THOSE SHEETS.
 PLANS SIGNED & SEALED BY A PROFESSIONAL
 ENGINEER SHALL INCLUDE EITHER THE NAME,
 ADDRESS AND LICENSE NUMBER OF THE
 ENGINEER OR, THE PRINTED NAME AND
 LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF ANY ENGINEERING
 BUSINESS THROUGH WHICH THE ENGINEER IS
 PRACTICING (471.025 F.S. AND 471.023
 F.S.).
  
 5) FBC 1804.4.2SHEET S-1, FOOTING
 SIZES.THE INCLUSION OF FOOTING TYPE
 MARKERS F-1, F-2 AND TE-1 ON THE PLAN IS
 NOTED.NO FOOTING SIZES SCHEDULE OR
 DESIGN SOIL BEARING CAPACITY STATEMENT
 ARE INCLUDED ON THE PLANS.ADD THE
 REQUIRED INFORMATION.
  
 6) FBC 1606.1SHEET S-4, TRUSS ANCHOR
 SCHEDULE. ANCHOR TYPE E, USP USC43 IS
 STATED AS HAVING AN UPLIFT CAPACITY OF
 12,340 LBS. THE 2005 USP CATALOGUE LISTS
 THE CAPACITY AS 11,150 LBS BECAUSE 1/3
 STRESS INCREASE IS NOT PERMITTED ON
 STEEL CAPACITIES.AMEND THE SCHEDULE
 AND ALSO THE ANCHOR FOR THE RIGHT SIDE
 VALLEY OVER THE FRONT ELEVATION WHICH IS
 SHOWN, ON SHEET S-3, AS HAVING A
 REQUIRED UPLIFT OF 11286 LBS
 (>11,150 LBS CAPACITY)
  
 7) SHEET S-4, STRUCTURAL NOTES, REFERS
 TO 'PALM BEACH COUNTY AMENDMENTS' UNDER
 THE SUBTITLE 'CODES'.AMEND THIS TO
 READ CITY OF WEST PALM BEACH AMENDMENTS.
  
 8) FBC 1604.1SHEET S-4, STRUCTURAL
 NOTES, 'GRAVITY LOAD' AND 'MATERIAL NOTE
 H - WOOD TRUSSES'.AMEND THE NOTES TO
 INCLUDE THE TRUSS BOTTOM CHORD LIVE LOAD
 REQUIREMENT OF 30 PSF FOR RESIDENTIAL
 ATTICS WITH STORAGE.
  
 9) FBC 3502SHEET S-4, STRUCTURAL
 NOTES, REFERS TO "ACI-95" (FOR
 REINFORCED CONCRETE) UNDER THE SUBTITLE
 'CODES'.THE STANDARD REFERENCED BY
 FLORIDA BUILDING CODE IS 'ACI 318-02 -
 BUILDING CODE REQUIREMENTS FOR
 STRUCTURAL CONCRETE'.AMEND THE NOTES.
  
 10) FBC 3502SHEET S-4, STRUCTURAL
 NOTES, REFERS TO OUTDATED STANDARDS ASTM
 C90-70, C140-70, C270-73 AND C150-74
 UNDER THE SUBTITLE 'CODES'.THE
 VERSIONS OF THESE STANDARDS REFERENCED
 BY FLORIDA BUILDING CODE ARE ASTM
 C90-99B, C140-99B, C270-00 AND C150-94.
 AMEND THE NOTES.
  
 11) FBC 11-11(1)SHEET A-12, POWDER
 ROOM DOOR 114.THE PROPOSED DOOR WIDTH
 IS 2'-6" WHICH WILL NOT GIVE THE
 REQUIRED CLEAR OPENING WIDTH OF 29" WHEN
 MEASURED IN ACCORDANCE WITH FIG. 24(A).
 AMEND THE DOOR SCHEDULE.
  
 12) FBC 2804.4SHEET A-10, FACTORY
 BUILT CHIMNEY/FIRE-BOX.SUBMIT TWO
 COPIES OF MANUFACTURER'S DATA COVERING
 INSTALLATION INSTRUCTIONS AND TEST
 REPORT LISTING.
  
 13) ONLY ONE COPY OF SOME DOCUMENTS HAVE
 BEEN SUBMITTED.TWO COPIES OF THE SITE
 SURVEY, SOIL REPORT AND ALL PRODUCT
 APPROVALS ARE REQUIRED.
  
 14) THE REQUIRED STATEWIDE PRODUCT
 APPROVAL LISTING COVER SHEETS HAVE BEEN
 ADDED TO THE SUBMITTED NOA'S FOR THE
 ROOF TILES AND GARAGE DOORS.PLEASE USE
 THESE AS EXAMPLES OF WHAT IS REQUIRED TO
 ADDRESS THE PRODUCT APPROVAL COMMENTS
 BELOW.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE
 STANDING SEAM METAL ROOF AND THE
 MAHOGANY ENTRY DOOR (DOOR 101).
 NOTE: FL. ADMIN CODE RULE 9B-72 (IN
 EFFECT SINCE OCTOBER 1, 2003) REQUIRES
 THAT PRODUCTS HAVE STATEWIDE, LOCAL OR
 SITE-SPECIFIC PRODUCT APPROVAL.THE
 SUBMITTAL SHOULD INCLUDE THE STATEWIDE
 PRODUCT APPROVAL NUMBER (FL###),
 AVAILABLE FROM THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 (IF YOU FIND THAT THE QUOTED WEB PAGE IS
 NO LONGER AVAILABLE, PLEASE INFORM THE
 PLAN REVIEWER).
  
 16) FL. ADMIN CODE RULE 9B-72.
 A SEARCH AT THE DEPT OF COMMUNITY
 AFFAIRS PRODUCT APPROVAL WEBSITE
 WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP
 SHOWS NO MATCHING STATEWIDE PRODUCT
 APPROVAL FOR THE SUBMITTED CONSTRUCTION
 GLASS INDUSTRIES CORPORATION ALUMINUM
 STOREFRONT DOOR, FIXED WINDOW OR
 CASEMENT WINDOW PRODUCT APPROVAL NOA'S
 01-1109.03, 01-0918.01 AND 01-1002.03
 RESPECTIVELY.
 SPECIFY ALTERNATIVES THAT HAVE STATEWIDE
 OR LOCAL PRODUCT APPROVAL.IF YOU FIND
 THAT THE QUOTED WEB PAGE IS NO LONGER
 AVAILABLE, PLEASE INFORM THE PLAN
 REVIEWER.
  
 17) PRODUCT APPROVAL.RULE 9B-72 FAC.
 FOR PRODUCTS WHICH DO NOT HAVE STATEWIDE
 PRODUCT APPROVAL, LOCAL PRODUCT APPROVAL
 CAN BE ACHIEVED IF THERE IS A QUALITY
 ASSURANCE PROGRAM IN PLACE WITH A STATE
 APPROVED QUALITY ASSURANCE ENTITY.IF
 NEITHER IS APPLICABLE, THEN SITE
 SPECIFIC APPROVAL IS REQUIRED.LOCAL
 PRODUCT APPROVAL WILL ALLOW A PRODUCT TO
 BE USED, IN ACCORDANCE WITH THE TEST
 CRITERIA, THROUGHOUT THE JURISDICTION OF
 WEST PALM BEACH.SITE SPECIFIC PRODUCT
 APPROVAL WILL ALLOW A PRODUCT TO BE
 USED ONLY ON THE PROJECT FOR WHICH THAT
 SITE SPECIFIC APPROVAL IS GRANTED.
 LOCAL AND SITE SPECIFIC PRODUCT APPROVAL
 APPLICATION FORMS ARE AVAILABLE FROM
 THIS OFFICE.APPROVED QUALITY ASSURANCE
 ENTITIES ARE LISTED ON THE DCA WEBSITE:
 WWW.FLORIDABUILDING.ORG/COMMON/C_ORG_
 REGI_SRCH.ASP (IF YOU FIND THAT THE
 QUOTED WEB PAGE IS NO LONGER AVAILABLE,
 PLEASE INFORM THE PLAN REVIEWER)
  
 18) TO EXPEDITE REVIEW OF A RESUBMITTAL
 WHICH REQUIRES NEW PLANS IN ORDER TO
 ADDRESS THE ABOVE COMMENTS, THE OLD
 SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHOULD BE STAPLED/CLIPPED TO THE
 REMAINING OLD SHEETS, TO FORM A SET OF
 'OLD/VOID SHEETS', FOR COMPARISON OF
 REVISIONS WHEN REVIEWING THE RESUBMITTED
 PLANS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2006-03-29 Cont ID  
Sent By btrobaug Date 2006-03-29 Time 10:20 Rev Time 0.50
Received By btrobaug Date 2006-03-29 Time 10:20 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status F Date 2006-03-27 Cont ID  
Sent By btrobaug Date 2006-03-27 Time 13:06 Rev Time 0.50
Received By btrobaug Date 2006-03-27 Time 12:10 Sent To PC
Notes
2006-03-27 00:00:00BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
  
  
 FAILED
 ~~~~~~
  
 1} REVISION #6 WAS SUBMITTED ON 3/10/06.
 THIS WOULD BE REVISION #7.
 PLEASE INDICATE THE MOST CURRENT CHANGES
 ONLY ON THE REVISED PLAN WITH THE
 CORRECT REVISIION NUMBER.
  
 2} THE CABANA PANEL SHOULD NOW BE LABLED
 "D" ON SHEET "E-1".
  
 3} THE PLANS MUST CONTAIN THE ARCHITECTS
 SIGNATURE PER 61G1-16.003 FAC. THE STAMP
 ON THE SEAL DOES NOT COMPLY PER THE
 FLORIDA BOARD OF ARCHITECTURE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-03-13 Cont ID  
Sent By btrobaug Date 2006-03-13 Time 17:41 Rev Time 0.75
Received By btrobaug Date 2006-03-13 Time 17:03 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-11-23 Cont ID  
Sent By btrobaug Date 2005-11-23 Time 09:08 Rev Time 1.00
Received By btrobaug Date 2005-11-22 Time 17:12 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-06-30 Cont ID  
Sent By btrobaug Date 2005-06-30 Time 18:12 Rev Time 0.33
Received By btrobaug Date 2005-06-30 Time 18:12 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-04-18 Cont ID  
Sent By btrobaug Date 2005-04-18 Time 16:27 Rev Time 0.75
Received By btrobaug Date 2005-04-18 Time 12:46 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-03-25 Cont ID  
Sent By btrobaug Date 2005-03-25 Time 16:03 Rev Time 1.00
Received By btrobaug Date 2005-03-25 Time 13:59 Sent To P
Notes
2005-03-25 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
  
 1} PANEL "C" MUST BE GROUNDED PER
 250.32.
  
 2} THE GREOUNDING ELECTRODE CONDUCTOR
 FOR THE SERVICE MUST BE A MINIMUM #1/0CU
 PER 250.66.
  
 3} THE AHU'S HAVE 30 AMP DISCONNECTS
 WITH #12 WIRE ON THE RISER.THEY HAVE 60
 AMP OCP WITH #12 WIRE AND ARE RATED AT
 9.6KVA ON THE PANEL SCCHEDULE, PLEASE
 CORRELATE.
  
 4} THE RISER SHOWS PANEL "C" BEING FED
 FROM PANEL "B", BUT THERE IS NO FEED FOR
 SAME IN PANEL SCHEDULE "B".
  
 5} PLEASE NOTE THAT THE TERM "OUTLETS"
 IN 210.12 REGARDING BEDROOMS ALSO
 INCLUDES SMOKE DETECTORS, LIGHTS,FANS, "
 ALL 15 & 20 AMP BRANCH CIRCUITS".
  
 6} THE GUEST ROOM (106) NEEDS A
 RECEPTACLE TO COMPLY WITH 210.52(A).
  
 7} THE CABANA BATHROOM RECEPTACLE MUST
 COMPLY WITH 210.11(3)(C). INDICATE SAME
 ON PANEL SCHEDULE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-02-22 Cont ID  
Sent By btrobaug Date 2005-02-22 Time 16:44 Rev Time 0.75
Received By btrobaug Date 2005-02-22 Time 15:32 Sent To M
Notes
2005-02-22 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE ARE NO MAIN DISCONNECTS SHOWN
 FOR PANELS "A" & "B", THE RISER ONLY
 SHOWS A METERAS DOES THE PLAN. ALSO
 PANELS ARE LISTED AS MLO, THEY MUST HAVE
 A DISCONNECTING MEANS.
  
 2} PLEASE SEE THAT THE FEEDERS FOR THE
 AHU'S AND CU'S ARE INCORRECT ON THE
 RISER DIAGRAM, ALSO THE OCP'S.
  
 3} A RECEPTACLE NEEDS TO BE ADDED TO THE
 FRONT OUTSIDE PER 210.52(E).
  
 4} RECEPTACLES NEED TO BE ADDED TO THE
 LIBRARY PER 210.52(A).
  
 5} THE KITCHEN COUNTERTOP RECEPTACLES DO
 NOT COMPLY WITH 210.52(C) SPACING
 REQUIREMENTS.
  
 6} BEDROOM #3 NEEDS A RECEPTACLE ADDED
 TO COMPLY WITH 210.52(A)(2).
  
 7} THE ARHITECTS TITLE BLOCK NEEDS THE
 FIRM LICENSE # PER 61G1-16.004(2), FAC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2006-03-28 Cont ID  
Sent By adarroug Date 2006-03-28 Time 12:14 Rev Time 0.00
Received By adarroug Date 2006-03-28 Time 12:14 Sent To E
Notes
2006-03-28 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2006-03-23 Cont ID  
Sent By dpalmer Date 2006-03-23 Time 12:52 Rev Time 0.00
Received By dpalmer Date 2006-03-23 Time 12:52 Sent To E
Notes
2006-03-23 00:00:00TO BT'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-03-13 Cont ID  
Sent By adarroug Date 2006-03-13 Time 14:44 Rev Time 0.00
Received By adarroug Date 2006-03-13 Time 14:44 Sent To E
Notes
2006-03-13 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-03-02 Cont ID  
Sent By adarroug Date 2006-03-02 Time 11:54 Rev Time 0.00
Received By adarroug Date 2006-03-02 Time 11:54 Sent To B
Notes
2006-03-02 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-11-22 Cont ID  
Sent By adarroug Date 2005-11-22 Time 15:36 Rev Time 0.00
Received By adarroug Date 2005-11-22 Time 15:36 Sent To E
Notes
2005-11-22 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-10-20 Cont ID  
Sent By adarroug Date 2005-10-20 Time 09:55 Rev Time 0.00
Received By adarroug Date 2005-10-20 Time 09:55 Sent To M
Notes
2005-10-20 00:00:00TO "M" BOX

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-09-02 Cont ID  
Sent By adarroug Date 2005-09-02 Time 16:08 Rev Time 0.00
Received By adarroug Date 2005-09-02 Time 16:08 Sent To B
Notes
2005-09-02 00:00:00TO "RBROWN" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-06-09 Cont ID  
Sent By shill Date 2005-06-09 Time 13:54 Rev Time 0.00
Received By shill Date 2005-06-09 Time 13:54 Sent To B
Notes
2005-06-09 00:00:00TO RB DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-05-31 Cont ID  
Sent By adarroug Date 2005-05-31 Time 14:13 Rev Time 0.00
Received By adarroug Date 2005-05-31 Time 14:13 Sent To B
Notes
2005-05-31 00:00:00TO "RBROWN" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-14 Cont ID  
Sent By adarroug Date 2005-04-14 Time 10:03 Rev Time 0.00
Received By adarroug Date 2005-04-14 Time 10:03 Sent To E
Notes
2005-04-14 00:00:00TO "BTROBAUG" DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-24 Cont ID  
Sent By adarroug Date 2005-03-24 Time 10:56 Rev Time 0.00
Received By adarroug Date 2005-03-24 Time 10:56 Sent To E
Notes
2005-03-24 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-21 Cont ID  
Sent By adarroug Date 2005-03-21 Time 08:54 Rev Time 0.00
Received By adarroug Date 2005-03-21 Time 08:54 Sent To Z
Notes
2005-03-21 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-22 Cont ID  
Sent By rbrown Date 2005-03-08 Time 17:42 Rev Time 0.00
Received By adarroug Date 2005-02-22 Time 11:35 Sent To E
Notes
2005-02-22 00:00:00TO SF RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-14 Cont ID  
Sent By adarroug Date 2005-02-14 Time 09:04 Rev Time 0.00
Received By adarroug Date 2005-02-14 Time 09:04 Sent To Z
Notes
2005-02-14 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-11-10 Cont ID  
Sent By tgordon Date 2005-11-10 Time 11:22 Rev Time 0.20
Received By tgordon Date 2005-11-10 Time 11:22 Sent To  
Notes
2005-11-10 00:00:00'E' CAL. REV.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-10-20 Cont ID  
Sent By tgordon Date 2005-10-20 Time 16:38 Rev Time 0.30
Received By tgordon Date 2005-10-20 Time 16:38 Sent To  
Notes
2005-10-20 00:00:00*** DENIED ***
 1) A/C EQUIPMENT LIST ON PLANS SHOWS A/C
 #1 10.25 SEER, #2 10.25 SEER, #3 10.25
 SEER, AND #4 10.0 . ENERGY CAL'S. ON
 FLLE CALL FOR A/C #1 12.25 SEER, #2
 12.50 SEER, #3 12.00 SEER, AND #4 10.00
 SEER. THE PLANS MUST MATCH THE ENERGY
 CAL'S. .
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-04-07 Cont ID  
Sent By prafter Date 2005-04-07 Time 07:59 Rev Time 0.45
Received By prafter Date 2005-04-07 Time 07:59 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-02-24 Cont ID  
Sent By btrobaug Date 2005-02-22 Time 16:45 Rev Time 0.50
Received By prafter Date 2005-02-24 Time 10:24 Sent To P
Notes
2005-02-24 00:00:00MECH. PLAN REVIEW.2/24/05
  
 EQUIPMENT INFORMATION FOR CABANA NOT
 REFLECTED ON A/C PLANS.
  
 PAT RAFTER 561/805/6728.
  
 PLEASE CALL IF THEAR ANY QUESTION.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-04-02 Cont ID  
Sent By kstevens Date 2005-04-02 Time 14:29 Rev Time 0.60
Received By kstevens Date 2005-04-02 Time 14:29 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-02-26 Cont ID  
Sent By jleech Date 2005-02-26 Time 14:27 Rev Time 0.50
Received By jleech Date 2005-02-26 Time 14:27 Sent To B
Notes
2005-02-26 00:00:00DENIED;
 RISER DIAGRAM IS NOT TO CODE. SEE RED
 LINES ON ONE OF THE PLANS
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status P Date 2005-03-23 Cont ID  
Sent By mmclean Date 2005-03-23 Time 15:57 Rev Time 0.00
Received By mmclean Date 2005-03-23 Time 15:57 Sent To I
Notes
2005-03-23 00:00:00MUST PULL A SEPERATE PERMIT FOR
 POOL/DECK

Review Stop Z ZONING
Rev No 1 Status F Date 2005-03-08 Cont ID  
Sent By mmclean Date 2005-02-18 Time 11:29 Rev Time 0.00
Received By mmclean Date 2005-02-18 Time 11:29 Sent To I
Notes
2005-02-18 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE 1ST 25FT
 FRONT SETBACK. MUST REDUCE THE DRIVEWAY
 TO MEET 1000SQ FT OR 75% WHICHEVER IS
 LESS OF LANDSCAPE WITHIN THE FRONT
 SETBACK.
 2. THE ALLOWABLE HEIGHT REQUIRED FOR
 STRUCTURE IS MAX 33FT (WITH CHIMENY).
 ELEVATION SHOWS 38FT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 CONSTRUCTION SERVICES
 805-6720