Plan Review Details - Permit 05020451
Plan Review Stops For Permit 05020451
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-01-26 Cont ID  
Sent By alange Date 2006-01-26 Time 12:06 Rev Time 0.50
Received By alange Date 2006-01-26 Time 12:06 Sent To  
Notes
2006-01-26 00:00:00REVISION TO BLOCK UP 2 WINDOWS....OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-07-18 Cont ID  
Sent By alange Date 2005-07-18 Time 16:21 Rev Time 1.00
Received By alange Date 2005-07-18 Time 16:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-27 Cont ID  
Sent By alange Date 2005-06-27 Time 13:20 Rev Time 1.25
Received By alange Date 2005-06-27 Time 11:16 Sent To  
Notes
2005-06-27 00:00:00DENIED
  
 CORRECTIONS NOT ADDRESSED FROM FIRST
 REVIEW:
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 4.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS WITH QUALITY ASSURANCE FOR THE
 FOLLOWING.
 SINGLE HUNG WINDOW MISSING MIAMI-DADE
 APPROVAL.
 ALL PRODUCT APPROVALS SUBMITTED SHALL
 HAVE THE FOLLOWING ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 8.ROOF SHEATHING FASTENING SHALL
 COMPLY WITH FBC 2306.1.SHOW ON PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-03-07 Cont ID  
Sent By alange Date 2005-03-07 Time 13:30 Rev Time 1.66
Received By alange Date 2005-03-07 Time 11:34 Sent To  
Notes
2005-03-07 00:00:00DENIED
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA THE VALUATION HAS BEEN CHANGED TO
 $56,027.00.ADDITIONAL PERMIT FEES OF
 $515.65 ARE DUE.
  
 4.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS WITH QUALITY ASSURANCE FOR THE
 FOLLOWING.ROOFING, WINDOWS, EXTERIOR
 DOORS, IMPACT PROTECTION, STRAPS AND
 TIE-DOWNS AND LINTELS.
 ALL PRODUCT APPROVALS SUBMITTED SHALL
 HAVE THE FOLLOWING ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5.SAFTEY GLAZING REQUIRED AT WINDOW AT
 TUB LOCATION FBC 2405.2.1
  
 6.SUBMIT 2 COPIED OF A SITE PLAN
 SHOWING ROOM ADDITION AND ALL BUILDINGS
 ON PROPERTY.
  
 7.SUBMIT 2 COPIES OF ENERGY CALCS.
  
 8.ROOF SHEATHING FASTENING SHALL
 COMPLY WITH FBC 2306.1.SHOW ON PLANS.
  
 9.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 10.FBC 3401.7.1.2.1 SHOW HOW
 COMPLIANCE WILL BE MADE FOR THIS SECTION
 FOR GFCI OUTLETS AND SMOKE DETECTORS.
  
 11.SQUARE FOOTAGE SUBMITTED ON
 APPLICATION WAS NOT CORRECT.IT HAS
 BEEN REVISED TO 728 SQ. FT.
 SHOW ON PLANS EXISTING SQUARE FOOTAGE
 AND NEW SQUARE FOOTAGE.
  
 12.IMPACT PROTECTION REQUIRED FOR NEW
 WINDOWS AND DOORS.
  
 13.NOTE:FINISH GRADE IS 4" ABOVE
 GRADE. THIS IS THE MINIMUM ALLOWED.
 THE FOOTING IS AT 12" DEEP ALSO A MIN.
 ALLOWED.IF THE GRADE ISN'T EXACTLY
 CORRECT EITHER THE FOOTING WON'T BE DEEP
 ENOUGH OR THE GRADE WILL BE TOO HIGH.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-01-20 Cont ID  
Sent By jleahy Date 2006-01-20 Time 22:22 Rev Time 0.45
Received By jleahy Date 2006-01-20 Time 22:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-06-22 Cont ID  
Sent By btrobaug Date 2005-06-22 Time 07:30 Rev Time 0.50
Received By btrobaug Date 2005-06-22 Time 07:18 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-02-22 Cont ID  
Sent By btrobaug Date 2005-02-22 Time 09:59 Rev Time 0.50
Received By btrobaug Date 2005-02-22 Time 09:21 Sent To P
Notes
2005-02-22 00:00:00 
 THERE ARE TWO RECEPTACLES IN THE BEDROOM
 AND ONE IN THE FAMILY TO BE ADDED FOR
 COMPLIANCE WITH 210.52(A)(1) & (2).
  
 THE LOAD CALCULATIONS DO NOT INCLUDE THE
 ADDITIONAL AHU TO BE INSTALLED. IT IS
 OBVIOUS THAT THE EXISTING SERVICE IS NOT
 LARGE ENOUGH TO SUPPORT THE ADDITIONAL
 LOAD. PLEASE SUBMIT PLANS FOR A SERVICE
 CHANGE INCLUDING RISER DIAGRAM AND AIC
 CALCULATIONS PER 110.9 & 10., IF
 ADDITIONAL LOADS WARRANT.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-01-17 Cont ID  
Sent By adarroug Date 2006-01-17 Time 15:14 Rev Time 0.00
Received By adarroug Date 2006-01-17 Time 15:14 Sent To E
Notes
2006-01-17 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 08:58 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 08:58 Sent To Z
Notes
2005-07-18 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-15 Cont ID  
Sent By shill Date 2005-06-15 Time 13:27 Rev Time 0.00
Received By shill Date 2005-06-15 Time 13:27 Sent To E
Notes
2005-06-15 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-08 Cont ID  
Sent By mjacobs Date 2005-06-08 Time 09:43 Rev Time 0.00
Received By mjacobs Date 2005-06-08 Time 09:43 Sent To Z
Notes
2005-06-08 00:00:00TO 'Z' BOX/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-18 Cont ID  
Sent By adarroug Date 2005-02-18 Time 10:49 Rev Time 0.00
Received By adarroug Date 2005-02-18 Time 10:49 Sent To E
Notes
2005-02-18 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 09:19 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 09:19 Sent To Z
Notes
2005-02-08 00:00:00TO "Z"BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-06-27 Cont ID  
Sent By hmoser Date 2005-06-27 Time 08:35 Rev Time 0.00
Received By hmoser Date 2005-06-27 Time 08:35 Sent To B
Notes
2005-06-27 00:00:00PASS PRIVISO
 RETURN AIR NI MASTER BEEDROOM MUST BE 9
 IN.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-03-01 Cont ID  
Sent By prafter Date 2005-03-01 Time 08:13 Rev Time 0.50
Received By prafter Date 2005-03-01 Time 08:13 Sent To B
Notes
2005-03-01 00:00:00MECH. PLAN REVIEW.
  
 1. RETURN AIR OUT MASTER BEDROOM AREA
 REQUIRED. FBC/M 601.4 EXCEPTION 1.
 (TRANSFER 1 1/2 TIME THE CROSS SECTION
 AREA IN SQ. IN" FOR SIZE).
 2.A.H.U. ATTIC TO BE WITH IN 6 FOOT OF
 EXCESS. FBC/M 306.3 APPLIANCE IN ATTIC.
  
 PAT RAFTER 561/805/6728OR
 805/6719.
 PLEASE CALL IF THEAR ANY QUESTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-02-23 Cont ID  
Sent By kstevens Date 2005-02-23 Time 18:01 Rev Time 0.33
Received By kstevens Date 2005-02-23 Time 18:01 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2005-07-18 Cont ID  
Sent By mmclean Date 2005-07-18 Time 15:48 Rev Time 0.00
Received By mmclean Date 2005-07-18 Time 15:48 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2005-06-14 Cont ID  
Sent By mmclean Date 2005-06-14 Time 16:55 Rev Time 0.00
Received By mmclean Date 2005-06-14 Time 16:55 Sent To I
Notes
2005-06-14 00:00:00DENIED,
 1. NEED TO SHOW THE ADDITON ON THE TWO
 COPY OF SURVEY WITH THE SETBACK ON THE
 SIDE AND REAR.
 2. THE SITEPLAN AND SURVEY DOES NOT
 MATCH. (DRIVEWAY, DIMENSION OF STURCTURE
 AND SIDE SETBACK).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-02-16 Cont ID  
Sent By mmclean Date 2005-02-16 Time 16:38 Rev Time 0.00
Received By mmclean Date 2005-02-16 Time 16:38 Sent To I
Notes
2005-02-16 00:00:00DENIED, MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE ADDITION WITH SETBACKS.