| Plan Review Stops For Permit 05020247 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
F |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-15 |
Time |
10:58 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-02-15 |
Time |
10:58 |
Sent To |
R |
|
| Notes |
| 2006-02-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05020247 | | | ADD: 5405 N HAVERHILL BLDG# 3 | | | CONT:MILLER | | | TEL: (786)303-8374 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVREVIEW | | | ACTION: DENIED | | | | | | STRUCTURAL LETTERS SIGNED NOT SEALED | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-15 |
Time |
10:57 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-02-15 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-03 |
Time |
12:47 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-02-03 |
Time |
12:47 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05020247 | | | ADD: 5405 N HAVERHILL BLDG # 3 | | | CON: MILLER | | | TEL: (786)303-8374 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW | | | ACTION: DENIED | | | | | | 1) CHANGE OF WIND SPEED AND EXPOSURE, | | | STRUCTURAL ENGINEER TO REVIEW COMPLETE | | | BUILDING. | | | 61G15-27 | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
16:07 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-12-23 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-20 |
Time |
13:32 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2005-08-20 |
Time |
13:29 |
Sent To |
P |
|
| Notes |
| 2005-08-20 00:00:00 | 8-20-05 SOILS LETTER BLDG# 3 | | | STEEL SHOP DRAWINGS MEZZANINE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-16 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-16 |
Time |
18:21 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | TILT UP SHOPS, PHASE III |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-16 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-16 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | PANEL SHOPS, TILT UP LIFTING AND BRACING | | | SPECS, PHASE I | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-16 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-08-16 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | SHOP DRAWINGS, STRUCTURAL STEEL | | | MEZZANINE FRAMING, ROOF FRAMING, COLUMNS | | | | | | SHOP DRAWINGS, STRUCTURAL STEEL | | | MEZZANINE STAIR, STAIR FRAMIN BAY 1, | | | STAIR FRAMING BAY 14, STAIR FRAMING BAY | | | 3, 5, 15, 17 & 19, STAIR FRAMING 4, 16, | | | 18, STAIR FRAMING BAY 6, STAIR FRAMING | | | 7, 9, 11, 21, 23, 25; STAIR FRAMING BAY | | | 8, 10 12 20 22 24, BAY 13, MEZZANINE | | | RAILING PLAN, COLUMNS ANGLES & STAIRS, | | | TREAD & LANDING AT STAIR ***PROVISO*** | | | GUARDRAIL AT LANDING TO REJECT A | | | 2"OBJECT AT BOTTOM OF RAILING FBC1015.3 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-14 |
Time |
15:43 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-14 |
Time |
15:43 |
Sent To |
PC |
|
| Notes |
| 2005-08-14 00:00:00 | BLDG III CONCRETE TEST REPORTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-04 |
Time |
11:22 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-04 |
Time |
11:22 |
Sent To |
PC |
|
| Notes |
| 2005-08-04 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05020247 | | | ADD: 5405 N HAVERHILL BLDG III | | | CONT: MILLER | | | TEL: (954)444-6881 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW SOILS CERTIFICATION BLDG III | | | ACTION: DENIED | | | FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THE HEADER OR REFRENCE IS FOR BUILDING | | | III BUT IN THE BODY OF THE LETTER WORK | | | COMPLETED IS FOR BUILDING I. IF LETTER | | | IS FOR BUILDING III THE DESCRIPTION | | | SHALL MATCH. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-27 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-06-27 |
Time |
07:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-17 |
Time |
10:02 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2005-02-17 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2005-02-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05020247 | | | ADD: 5405 N HAVERHILL RD PH III | | | CONT:NORTON | | | TEL: (561)232-0590 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | COMMENTS FOR PHASE III ARE THE SAME AS | | | FOR PHASE II UNDER PERMIT # 05020246. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-12 |
Time |
14:43 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-12 |
Time |
14:31 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-01 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-01 |
Time |
17:41 |
Sent To |
ENG |
|
| Notes |
| 2006-03-01 00:00:00 | REV'S, 0.00,3.06,3.07,3.09 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-10 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-10 |
Time |
19:12 |
Sent To |
FIRE |
|
| Notes |
| 2006-02-10 00:00:00 | ************ UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE PLANS DO NOT INDICATE | | | OR SHOW GROUPING OF MAINS? ALTHOUGH ONLY | | | ONE MAIN IS SHOWN. | | | PLEASE VERIFY WHY SITE PLANS SHOWS MAINS | | | INT TWO DIFFERENT LOCATIONS.? | | | MAINS MUST BE GROUPED IN CLOSE | | | PROXIMITY, WHICH THAT DOES APPEAR TO BE | | | THE CASE AS SHOWN ON PLANS. | | | 230.72 | | | | | | 2)NOTE: PLEASE CORRELATE NOTES ON RISER | | | DIAGRAM AS THIS SHOWS TWO DIFFERENT | | | SIZES SERVICES.?600A , 800A? | | | PLEASE SEE PANELS 120/208V. | | | PLEASE SHOW LOAD CALCULATIONS AND | | | VOLTAGE FIGURED AS TOTAL DEMAND DOES NOT | | | SEEM TO CORRELATE WITH A 120/208V | | | 3-PHASE SYSTEM OR 277/480V? | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE GROUNDING ELECTRODE | | | SYSTEM. PLEASE SEE THE "EQUIPMENT | | | GROUNDING CONDUCTORS" AND THE NEUTRAL IS | | | "ONLY" BONDED AT THE FIRST MEANS OF | | | DISCONNECT. PLEASE SEE DETAIL AS THIS | | | SHOWS THE PARALLELING OF THE NEUTRAL AND | | | OBJECTIONABLE CURRENTS PER 250.6 | | | PLEASE PROVIDE A ONE-LINE OF THE | | | GROUNDING ELECTRODE SYSTEM ON RISER | | | DIAGRAM. 250.58 | | | | | | 4)NOTE: PLEASE SEE ONLY3-PHASE PANELS | | | ARE BEING SHOWN, HOWEVER, PLEASE SEE | | | RISER INDICATES SINGLE PHASE AND THREE | | | PHASE FEEDERS??? | | | PLEASE ALSO SEE TYPICAL DETAIL WHICH | | | SHOWS BOTH ?? | | | 215.5 | | | IF SERVICE IS THREE PHASE ALL THE WAY | | | THROUGH TO TENANT, PLEASE ADJUST AND | | | CORRELATE ALL PANELS. | | | | | | | | | *** PLEASECORRELATE ANDCOMPLETE | | | | | | PLEASE SUBMIT ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-12 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-12 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2006-01-12 00:00:00 | REV'S FOR SHEETS E3.02, .03,.05 ONLY | | | UNIT LAYOUT ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-14 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-11-14 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2006-01-12 00:00:00 | REDLINED HP, AS ORIG PLANS CALLED FOR | | | 277/480, HOWEVER PLANS NOW SHOW 120/208V | | | FOR HP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-06-13 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2005-06-13 00:00:00 | STAMPED ELECTRICAL SHEETS | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-25 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-02-25 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2005-02-25 00:00:00 | ***** UNSAT **** | | | | | | 1)NOTE: PLEASE SEE BLDG /FIRE REVIEW | | | COMMENTS WHICH WILL HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | 2)NOTE: PLEASEPLACE NOTE ON PLANS: | | | "OCCUPANCIES NOT SUBJECT TO | | | PUBLIC/PEDESTIRAN TRAFFIC" | | | IF SO, PLEASE SEE 600.5 | | | PLEASE ADJUST IF NEEDED. | | | \ | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-03-03 |
Time |
11:06 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2006-03-03 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-01-27 |
Time |
17:29 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2006-01-27 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | PASSED: | | | | | | 1. REVIEWED FOR REVISION. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-02-07 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2005-02-07 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | PASSED: | | | | | | 1. SEE PERMIT # 04110991 FOR | | | UNDERGROUND UTILITIES AND SITE WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-02-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-02-16 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-30 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-30 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2006-01-30 00:00:00 | REVISION DATED 12/5/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-16 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-16 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-14 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-14 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-22 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-22 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | 1) PLEASE BE ADVISED THAT ALL LIFE | | | SAFETY MUST COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2) THE TURN AROUND LOCATED NEXT TO THE | | | 10' UTILITY EASEMENT MUST PROVIDE A | | | CENTERLINE TURNING RADIUS OF 50'. | | | | | | 3) PLEASE BE ADVISED THAT THE FIRE | | | DEPARTMENT CONNECTION SHALL BE LOCATED | | | NO FURTHER THAN 150' FROM THE CLOSEST | | | FIRE HYDRANT. | | | | | | 4) PLANS DON'T REFLECT ANY FIRE HYDRANTS | | | ON THE WEST SIDE OF THE PROJECT. ARE | | | THERE ANY, AND COULD YOU PROVIDE THE | | | LOCATIONS? | | | | | | 5) WILL THERE BE GATE ACCESS INTO THE | | | PROPERTY AFTER HOURS? IF SO, PLEASE BE | | | ADVISED THAT A KNOX KEY SYSTEM SHALL BE | | | PROVIDED WITH A BACK UP IN THE EVENT OF | | | POWER FAILURE. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2006-04-12 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2006-04-12 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | REV/MECH GIVEN TO HAROLD MOSER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2006-02-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-10 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-10 |
Time |
16:18 |
Sent To |
B |
|
| Notes |
| 2006-02-10 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-03 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-03 |
Time |
15:25 |
Sent To |
E |
|
| Notes |
| 2006-02-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
19:41 |
Sent To |
|
|
| Notes |
| 2006-01-19 00:00:00 | TO "COMM" BD#37 | | 2005-12-12 00:00:00 | WAITING FOR "COMM" BD/3 | | | REV.(BLDG,ELEC,MECH) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-03 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-03 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | TO "COMM" BD#45 | | 2005-10-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-11 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-11 |
Time |
17:17 |
Sent To |
B |
|
| Notes |
| 2005-08-11 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-10 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-10 |
Time |
17:05 |
Sent To |
B |
|
| Notes |
| 2005-08-10 00:00:00 | TO "JWITMER" DESK/2SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-09 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-09 |
Time |
15:49 |
Sent To |
B |
|
| Notes |
| 2005-08-09 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-04 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-04 |
Time |
10:02 |
Sent To |
B |
|
| Notes |
| 2005-08-04 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-28 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-28 |
Time |
13:23 |
Sent To |
B |
|
| Notes |
| 2005-07-28 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-17 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-04 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2005-05-17 00:00:00 | TO "COMM" BD#11 | | 2005-05-04 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2005-02-04 00:00:00 | TO "COMM" BD/#63/COMM SHELF |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-04-13 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-04-13 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-01-23 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-01-23 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | PLEASE HAVE MANUFACTURERS INSTALLATION | | | INSTRUCTIONS FOR EQUIPMENT STANDS ON | | | SITE FOR INSPECTOR. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-12-05 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | NO MECHANICAL PLANS SUBMITTED WITH THIS | | | REVISION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-24 |
Time |
09:18 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-06-24 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2005-06-24 00:00:00 | PROVISO: | | | PLAN SHEET M7.01 SPLIT SYSTEM A/C UNIT | | | SCHEDULE, NOTE #7 - ALL A/C UNITS HANG | | | IN WAREHOUSE WITH TOP OF THE UNITS AT 19 | | | FT AFF.PER 2001 FBC(M)306.5, WHERE | | | EQUIPMENT IS INSTALLED AT A HEIGHT | | | GREATER THAN 16 FT, PERMANENT MEANS OF | | | ACCESS IS REQUIRED.THIS HEIGHT WILL | | | EXTEND FROM THE FLOOR LEVEL TO THE LEVEL | | | SERVICE SPACE OF THE EQUIPMENT.PLEASE | | | PROVIDE INFORMATION ON HOW THE EQUIPMENT | | | IS TO BE SERVICED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-22 |
Time |
06:31 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-03-21 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | DENIED: | | | 1.PLAN SHEET M8.01 DETAIL 2, THE | | | DETAIL FOR THE AHU INDICATES AN OVERFLOW | | | SWITCH IN THE UNIT DRAIN PAN.PER 2001 | | | FBC/M 307.2.3, AN AUXILIARY DRAIN PAN IS | | | REQUIRED WITH THE FLOAT SWITCH INSTALLED | | | IN THE AUXILIARY DRAIN PAN.THE CODE | | | DOES NOT ALLOW FOR THE INSTALLATION AS | | | DEPICTED IN DETAIL 2. | | | | | | 2.PLEASE INDICAGE AT WHAT HEIGHT THE | | | AHU WILL BE INSTALLED. | | | | | | 3.PLEASE NOTE, SYSTEMS WITH THE DESIGN | | | CAPACITY GREATER THAN 2,000 CFM ARE | | | REUQIREED TO BE EQUIPPED WITH A DUCT | | | SMOKE DETECTOR.PLEASE REFERENCE AC-3 | | | ON THE EQUIPMENT SCHEDULE. | | | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2005-10-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-10-15 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-10-15 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2005-10-15 00:00:00 | NO CHANGES SHOWN ON THIS REVISION FOR | | | PLUMBING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-01 |
Time |
13:49 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-05-25 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | SEPARATE IRRIGATION PLANS/PERMIT | | | REQUIRED - PLANS SHALL SHOW THE LOCATION | | | FOR THE CONTROLLER/TIMER, RAIN SENSOR, | | | AND THE BACKFLOW PROTECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-04 |
Time |
17:11 |
Rev Time |
3.85 |
| Received By |
kstevens |
Date |
2005-03-04 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT L-3 SHOW THE LOCATION OF THE | | | CONTROLLER/TIMER, AND RAIN SENSOR. | | | SECTION 104.2.1. | | | 2) SHT C.5 RPZ BACKFLOW IS REQUIRED ON | | | THE WATER SERVICE TO EACH BUILDING. | | | SECTION 608.13.2. | | | 3) INDICATE THE SF AREA FOR EACH UNIT TO | | | CALCULATED THE MINIMUM FACILITIES PER | | | TABLES 1003.1 & 403.1. | | | 4) SHT A3.06 DETAIL #3 PROVIDE | | | CALCULATIONS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.26.3(2)(3)(4). | | | CALCULATIONS FROM THE ENGINEER REQD. | | | 5) SHT A3.09 SHOW COMPLIANCE WITH | | | SECTION 11-4.19.4 EXPOSED PIPES & | | | SURFACES. EXPOSED PIPES SHALL BE | | | INSULATED TO PREVENT INJURY. | | | 6) SHTS P5.01 & P5.02 WATER RISER | | | DIAGRAMS, SECTION 606.1(4) FULL OPEN | | | VALVES ARE REQUIRED ON EVERY WATER DOWN | | | FEED PIPE. SECTION 606.2(2) SHUT OFF | | | VALVES REQUIRED FOR HOSE BIBBS. THESE | | | VALVES SHALL BE SHOWN ON ALL ISOMETRIC | | | WATER RISER DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2006-01-30 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-01-30 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
lshapiro |
Date |
2006-01-20 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
lshapiro |
Date |
2006-01-20 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | THE PLANNING & ZONING DEPARTMENT WILL | | | NEED A REVISED SITE AND LANDSCAPE PLANS | | | PRIOR TO BUILDING PERMIT APPROVAL. | | | | | | THE FOLLOWING INFORMATION IS NEEDED: | | | 1. PROVIDE A SITE PLAN AND LANDSCAPE | | | PLAN MATCHING THE BUILDING PLANS | | | (INCLUDING BUILDINGS 1-3); | | | 2. MATCH THE PHOTOMETRIC PLAN WITH THE | | | APPROVED SITE PLAN (PAGE E.300). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-01 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-01 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | JOSH LONG, SENIOR PLANNER, 822-1449 | | | APPROVED. |
|
|