| Plan Review Stops For Permit 05020237 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-04-12 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-04-12 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | REVISED SP1, SP2, A1, A2, A10 DATED 12/7 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-01-10 |
Time |
12:26 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2006-01-10 |
Time |
12:18 |
Sent To |
PC |
|
| Notes |
| 2006-01-10 00:00:00 | REVISED SP1, AP2, A1, A2, A10, |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-20 |
Time |
13:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-05-20 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2005-05-20 00:00:00 | REVISED S2,3,4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-20 |
Time |
13:09 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-05-20 |
Time |
13:09 |
Sent To |
PC |
|
| Notes |
| 2005-05-20 00:00:00 | ***CORRECTIONS*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | 1.)NO CHANGES SHOWN ON S2 AND S3. | | | PLEASE CLOUD ALL CHANGES. | | | | | | 2.)SHEET S4, NO ZONE 3 FOR THE HIP | | | ROOF IS SHOWN.FBC FIGURE 1606.2(C). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-04-22 |
Time |
09:12 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-04-22 |
Time |
09:12 |
Sent To |
PC |
|
| Notes |
| 2005-04-22 00:00:00 | SUBMIT STATE OR LOCAL PRODUCT APPROVALS | | | FOR NOA03-0730.03, USP TD HOLDDOWNS OR | | | SUBMIT A REVISION FOR CONNECTORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-03-28 |
Time |
09:05 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-03-28 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2005-03-28 00:00:00 | DENIED | | | | | | 3.PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE REQUIRED FOR THEFOLLOWING. | | | STRAPS AND TIE-DOWNS AND LATICRETE | | | MEMBRANE. | | | | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-03-08 |
Time |
07:09 |
Rev Time |
2.25 |
| Received By |
alange |
Date |
2005-03-08 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | DENIED | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3.PRODUCT APPROVALS WITH QUALITY | | | ASSURANCE REQUIRED FOR THE FOLLOWING. | | | FLAT ROOF, STRAPS AND TIE-DOWNS, | | | LATICRETE MEMBRANE. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 4.ATTIC ACCESS SHALL BE A MIN OF 20 X | | | 36" PER FBC 2309.6 | | | | | | 5.SUBMIT A GUARDRAIL DETAIL SHOWING | | | OPENINGS COMPLYING WITH FBC 1015.3 | | | | | | 6.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 7.REVISE DETAIL ON DOOR AND WINDOW | | | BUCKS SO THAT THE BUCK OFFERS FULL | | | SUPPORT OF THE DOOR OR WINDOW FRAME. | | | FBC 1707.4.4.2 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-25 |
Time |
14:36 |
Sent To |
PC |
|
| Notes |
| 2006-06-25 00:00:00 | *** PLEASE SEE RISER SHOW PANEL "C" AS | | | 100A AND PANEL "C" SCHEDULE SHOWS 125A. | | | | | | PLEASE CORRELATE BEFORE FINAL. | | | THIS CAN BE ADDRESSED IN LTR FORM AS | | | LONG AS THERE ARE NO OTHER | | | REVISIONS/CHANGES. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICALPLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-09 |
Time |
07:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-09 |
Time |
07:01 |
Sent To |
PC |
|
| Notes |
| 2006-06-09 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE IN NO CASE CAN WHITE | | | OUT BE USED ON PLANS WHICH ARE SIGNED, | | | DATED AND SEALED. FS 471/481 | | | PLEASE SEE CONDUCTORS ON PLANS CHANGED | | | FROM 3/0'S TO 2/0'S FROM ALL PREVIOUS | | | DESIGNS ON PLANS. | | | 215.5 | | | | | | 2) NOTE: PLEASE CORRELATE RISER WITH | | | FEEDERS SHOWN ON PANEL "B" FOR PANEL | | | "C". | | | PLEASE SEE TWO DIFFERENT SIZES ARE | | | SHOWN? | | | 215.5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-05-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-19 |
Time |
12:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-19 |
Time |
09:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-03-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-18 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-18 |
Time |
13:22 |
Sent To |
Z |
|
| Notes |
| 2006-03-18 00:00:00 | ********* UNSAT ********* | | | | | | PLEASE SEE SOME COMMENTS FROM PREVIOUS | | | REVIEW AND SOME NEW COMMENTS DUE TO | | | CHANGES IN PLANS. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW WIHT NEW | | | NOTES ADDED. | | | | | | | | | 1)NOTE: NOTE #1 NO, SPOKE TO CONTRACTOR, | | | HE WILL COME IN AND ADJUST. | | | | | | ** PREVIOUS NOTE** | | | PLEASE SEE THERE HAVE BEEN MAJOR | | | CHANGES IN THE SCOPE OF ELECTRICAL WORK | | | AND OTHER REMODEL WORK DONE FOR | | | DWELLING. | | | PLEASE SEE FBC ADMINSTRATIVE 104.6.5 | | | WHICH REQUIRES A MAJOR ADJUSTMENT IN | | | VALUATION OF PERMITTING. | | | PLEASE SEE ORIG WAS INCLUSIVE OF SOME | | | REMODEL AND ADDITION WORK AT $130,000 | | | PLEASE ADJUST. | | | PLANS ARE NOW INDICATING THE ENTIRE | | | HOUSE BEING REWIRED ETC. | | | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE REDLINED | | | PLANS. THESE LOCATIONS COULD BE | | | REDLINED, HOWEVER PLANS ARE COMING BACK | | | FOR OTHER COMMENTS. | | | | | | ** PREVIOUS NOTE** | | | PLEASE SEE SOME RECEPTS NOW | | | MISSING DUE TO SOME WALL CHANGES.210.52 | | | | | | 3)NOTE: NOTE #3 OK? SPACE IN KITCHEN | | | SEEMS TO BE 12" OR MORE, THIS IS TO BE | | | FEILD VERIFIED AND IF ONE IS NEEDED, IT | | | IS TO BE ADDED. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE BE SURE TO DOUBLE CHECK | | | KITCHEN COUNTERSPACE AS SOME SPACING | | | SEEMS TO REQUIRE ADDITIONAL | | | RECEPTS.210.52C1 | | | | | | 4)NOTE: NOTE #4 OK. | | | | | | 5)NOTE: NOTE #5 OK. | | | | | | 6)NOTE: NOTE #6 NO, PLEASE SEE NEW | | | COMMENTS DUE TO CHANGES NOW MADE AND | | | SOME ITEMS ARE MISSING. | | | | | | ** PREVIOUS NOTE** | | | PLEASE SEE COMPLETE CHANGE IN | | | ELECTRICAL SERVICE HAS NOW CREATED SOME | | | ELECTRICAL COMMENTS: | | | | | | A)OK | | | | | | B)OK | | | | | | C)OK, HOWEVER SEE CONDUITS FROM MAINS AT | | | HOUSE TO SUB PANELS AT HOUSE ARE MISSING | | | EQUIPMENT GROUNDING CONDUCTOR. | | | 250.110,250.122 | | | ** PRE-NOTE** | | | PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTORS FROM METER/MAIN UP TO MAIN | | | HOUSE. 250.32 | | | PLEASE ALSO SEE MISSING GROUNDING | | | ELECTRODE SYSTEM AT MAIN HOUSE, SINCE | | | SERVICE IS NOW MOVED. | | | | | | D) OK, PLEASE SEE OCP WAS ADDED , | | | HOWEVER SEE NEW NOTE AS 100A OCP IN | | | METERMAIN IS FEEDING A 70 BRKR PANEL. | | | PLEASE VERIFY AS EITHER THE GUEST HOUSE | | | BRKR PANEL IS 100A'S, OR BRKR AT METER | | | MAIN IS 70A'S? | | | | | | ** PRE-NOTE**PLEASE SEE METER/MAIN IS | | | SHOWN AS | | | 400A, AND THERE IS NO INDICATION OF THE | | | OCP PROVIDED FOR SUB-PANEL FEEDERS TO | | | MAIN HOUSE OR ANY OTHER BRANCH BRKRS. | | | 240.4,310.16 ETC. | | | PLEASE ALSO VERIFY GUEST HOUSE BEING | | | SHOWN WITH A MAIN DISCONNECT AND | | | SUB-PANEL, AS IT IS SHOWN ON RISER BEING | | | FED FROM THE METER MAIN PANEL AT GUEST | | | HOUSE BLDG ALREADY? | | | DISC? | | | | | | E) NO, PLEASE SEE PANEL SCHEDULES STILL | | | SHOW PANEL AS 200A MCB WHICH IS OK, | | | HOWEVER PLEASE SEE RISER DIAGRAM NOW | | | SHOWS THE PANELS LOCATED INSIDE AS MLO?? | | | PLEASE CORRELATE. | | | | | | ** PRE-NOTE** | | | PLEASE ALSO VERIFY THE PANELS INSIDE | | | THE MAIN HOUSE AS BOTH ARE SHOWN WITH | | | MCB'S WHICH ARE PERMITTED ALTHOUGH NOT | | | REQUIRED. THIS IS ONLY A NOTE AND NO | | | CHNAGE IS NEEDED. PLEASE KNOW, IF SHOWN | | | AS MCB , THEN THESE WILL BE REQUIRED. | | | | | | F) OK. | | | | | | 7)NOTE: NOTE #7 OK | | | | | | 8)NOTE: NOTE #8 OK. | | | | | | 9)NOTE: NOTE # 9 OK. | | | | | | 10)NOTE: NOTE #10 OK , NOTED. | | | | | | ** NOW NOTE** | | | | | | 11)NOTE: PLEASE CORRELATE LOADS SHOWN | | | ON PANEL "C" AND LOAD ON PANEL "B" FOR | | | PANEL "C" LOAD. PREVIOUS PLANS, THESE | | | MATCHED, BUT HAVE NOW BEEN CHANGED. | | | | | | 12)NOTE: PLEASE KNOW, RISER SHOWS "IRON" | | | GROUND RODS, THIS IS OK, HOWEVER DOES | | | NOT SEEM TO BE A COMMON GE. THIS SI ONLY | | | A NOTE: | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-21 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-21 |
Time |
17:45 |
Sent To |
Z |
|
| Notes |
| 2005-12-21 00:00:00 | ********* UNSAT ********* | | | | | | 1)NOTE: PLEASE SEE THERE HAVE BEEN MAJOR | | | CHANGES IN THE SCOPE OF ELECTRICAL WORK | | | AND OTHER REMODEL WORK DONE FOR | | | DWELLING. | | | PLEASE SEE FBC ADMINSTRATIVE 104.6.5 | | | WHICH REQUIRES A MAJOR ADJUSTMENT IN | | | VALUATION OF PERMITTING. | | | PLEASE SEE ORIG WAS INCLUSIVE OF SOME | | | REMODEL AND ADDITION WORK AT $130,000 | | | PLEASE ADJUST. | | | PLANS ARE NOW INDICATING THE ENTIRE | | | HOUSE BEING REWIRED. | | | | | | 2)NOTE:PLEASE SEE SOME RECEPTS NOW | | | MISSING DUE TO SOME WALL CHANGES.210.52 | | | | | | 3)NOTE: PLEASE BE SURE TO DOUBLE CHECK | | | KITCHEN COUNTERSPACE AS SOME SPACING | | | SEEMS TO REQUIRE ADDITIONAL | | | RECEPTS.210.52C1 | | | | | | 4)NOTE: PLEASE SEE CU'S HAVE NOW BEEN | | | MOVED TO SIDE OF DWELLING, HOWEVER A NEW | | | GFI RECEPT WAS NOT ADDED FOR CU'S AS | | | REQUIRED PER 210.63 | | | | | | 5)NOTE: PLEASE SEE SD IN MASTER BEDRM | | | SHALL BE MOVED TO BE LOCATED WITHIN 3' | | | OF THE PEAK OF THE SLOPED CEILING AS | | | REQUIRED UNDER NFPA-72 11.8.3.5 | | | PLEASE SEE THIS WAS NOT NOTICED ON | | | PREVIOUS REVIEW, HOWEVER STILL IS | | | REQUIRED TO MEET CODE COMPLIANCE. | | | | | | 6)NOTE: PLEASE SEE COMPLETE CHANGE IN | | | ELECTRICAL SERVICE HAS NOW CREATED SOME | | | ELECTRICAL COMMENTS: | | | | | | A)PLEASE SEE RISER DIAGRAM AS IT SHOWS A | | | 200A DISCONNECT FEEDING THE 200A PANEL | | | WITH 3-#1'S ETC. | | | | | | B)PLEASE SEE CONDUCTORS TO POOL PANEL | | | ARE NOW SHOWN AS 3/0'S?? | | | BOTH SEEM TO BE A MIX-UP OF SORTS, | | | PLEASE CORRELATEAND ADJUST. | | | 310.16,240.4 | | | | | | C)PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTORS FROM METER/MAIN UP TO MAIN | | | HOUSE. 250.32 | | | PLEASE ALSO SEE MISSING GROUNDING | | | ELECTRODE SYSTEM AT MAIN HOUSE, SINCE | | | SERVICE IS NOW MOVED. | | | | | | D)PLEASE SEE METER/MAIN IS SHOWN AS | | | 400A, AND THERE IS NO INDICATION OF THE | | | OCP PROVIDED FOR SUB-PANEL FEEDERS TO | | | MAIN HOUSE OR ANY OTHER BRANCH BRKRS. | | | 240.4,310.16 ETC. | | | PLEASE ALSO VERIFY GUEST HOUSE BEING | | | SHOWN WITH A MAIN DISCONNECT AND | | | SUB-PANEL, AS IT IS SHOWN ON RISER BEING | | | FED FROM THE METER MAIN PANEL AT GUEST | | | HOUSE BLDG ALREADY? | | | DISC? | | | | | | E)PLEASE ALSO VERIFY THE PANELS INSIDE | | | THE MAIN HOUSE AS BOTH ARE SHOWN WITH | | | MCB'S WHICH ARE PERMITTED ALTHOUGH NOT | | | REQUIRED. THIS IS ONLY A NOTE AND NO | | | CHNAGE IS NEEDED. PLEASE KNOW, IF SHOWN | | | AS MCB , THEN THESE WILL BE REQUIRED. | | | | | | F)PLEASE SEE PANEL "C" AS THIS PANEL | | | SCHEDULE SHOWS THE OCP AND FEED FOR | | | GUEST HOUSE PANEL.?? | | | PLEASE CORRELATE WITH THE ABOVE NOTES | | | AND PLANS. | | | | | | 7)NOTE: PLEASE INDICATE THE GFI | | | PROTECTION REQUIRED FOR SPA/JACUZZI AT | | | MASTER BATH. THIS WAS REDLINED ON | | | PREVIOUS PLANS. | | | 680.71 | | | | | | 8)NOTE: PLEASE SEE WHAT APPEARS TO BE | | | SWITCHED RECEPTS IN A ROOM WITHOUT ANY | | | MEANS OF CONTROL. | | | | | | 9)NOTE: PLEASE PROVIDE ALL ROOM AND AREA | | | DESIGNATIONS ON PLANS. | | | | | | 10)NOTE: PLEASE SEE BLDG AND ZONING | | | COMMENTS AS BLDG ELECTRICAL AND ZONING | | | CHANGES ON SITE PLANS, AND DETAILED SITE | | | PLAN WILL BE REQUIRED TO BE DONE UNDER | | | SEPARATE PERMITS FOR FENCE/GATES, | | | FOUNTAIN, ETC. SEE OTHER REVIEWERS | | | NOTES. | | | ELECTRIC FOR GATES , LTS ETC SHALL BE ON | | | SEPARATE PLANS AND PERMITS. PLEASE KNOW, | | | WHEN SUBMITTING FOR ELECTRICAL FOR | | | GATES, SUPPLY ANY GATE CONTOLLER | | | SPEC/CUT SHEETS AND BE SURE THEY CONTAIN | | | A LISTING FROM A NRTL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-12 |
Time |
18:58 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-04-12 |
Time |
18:44 |
Sent To |
B |
|
| Notes |
| 2005-04-12 00:00:00 | NOTED THE FOLLOWING, NO CORRECTIONS OR | | | CHANGES NEEDED. | | | | | | "J-BOX" SHOWN FOR WP TUB, THIS IS TO BE | | | A DISC(IF HARDWIRED), GFI RECEPT OR | | | RECEPT WITH GFI BRKR PROTECTION. | | | 680.24 | | | | | | NOTED ON RISER, "ONLY NEW FOOTER STEEL | | | IS REQUIRED TO BE ATTACHED TO GROUNDING | | | ELECTRODE CONDUCTOR/SYSTEM. | | | | | | ARCHITECT CALLED, ALL COMMENTS WERE GONE | | | OVER AND CORRECTED AS NOTED. | | | | | | PLANS STAMPED. | | | THANK YOU |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-25 |
Time |
15:09 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-03-25 |
Time |
14:12 |
Sent To |
B |
|
| Notes |
| 2005-03-25 00:00:00 | ******* UNSAT 2ND REVIEW ********** | | | | | | PLEASE SEE SOME ITEMS FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #1 OK. | | | | | | 2)NOTE: NOTE #2 NO, PLEASE SEE MISSING | | | ONE. | | | | | | 3)NOTE: NOTE #3 OK | | | | | | | | | 4)NOTE: NOTE #4 OK, HOWEVER PLEASE SEE | | | TWO SD'S WHICH APPEAR TO HAVE BEEN ADDED | | | TODINING RM? | | | THIS IS ONLY A NOTE AND ARE PERMITTED, | | | IF SHOWN ON PLANS THEN THEY MUST BE | | | INSTALLED. | | | | | | 5)NOTE: NOTE #5 OK | | | | | | 6)NOTE: OK, HOWEVER PLEASE CLARIFY HOW | | | DETACHED BLDG IS BEING FED? | | | 225.31,250.32 ETC. | | | | | | 7)NOTE: NOTE #7 OK | | | | | | 8)NOTE: NOTE #8 OK, HOWEVER NOW THAT | | | PANEL SCHEDULES HAVE BEEN SUBMITTED FOR | | | REVIEW WITH CIRCUITING/OCP ETC, PLEASE | | | SEE NEW COMMENTS AT END OF THIS REVIEW. | | | | | | 9)NOTE: NOTE #9 OK | | | | | | 10)NOTE; NOTE #10 OK | | | | | | 11)NOTE: NOTE #11 NO, PLEASE SEE TWO | | | LOCATIONS REDLINED ON PLANS ON SECOND | | | FLR. | | | | | | 12)NOTE: NOTE # 12 OK | | | | | | 13)NOTE: NOTE #13 OK | | | | | | 14)NOTE: NOTE #14 NO, PLEASE SEE BOTH | | | AHU'S STILL DO NOT SHOW DISC'S. PLEASE | | | SEE PLANS REDLINED. | | | | | | 15)NOTE: NOTE #15 OK. | | | | | | 16)NOTE: NOTE #16, NO, SAME NOTE. 5' | | | STILL INDICATED. | | | | | | NEW NOTES. | | | | | | 1)NOTE: PLEASE SEE END OF NOTES ON | | | PREVIOUS REVIEW. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS IN | | | SETS AND INSERT ONLY NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | PLEASE SEE THIS IS TO HELP IN THE | | | PROCESS AND EXPEDITE PLANS. PLAN SETS | | | SHALL BE COMPLETE SETS WHEN SUBMITTING. | | | ONE SET OF OLD SHEETS SHOULD BE | | | SUBMITTED SEPARATELY FOR REFERENCE ONLY. | | | | | | 2)NOTE: PLEASE SEE 424.3B FORMIN OCP | | | FOR AHU'S. PLEASE SEE PLANS REDLINED. | | | | | | 3)NOTE: PLEASE CORRELATE PANEL "B" WITH | | | RISER DIAGRAM FOR POOL SUB PANEL. | | | ONE SHOWS 1/0'S AND THE OTHER #1'S. | | | | | | 4)NOTE: PLEASE SEE RANGE/OVEN SHOWN AS | | | 2P30A W/# 10AWG, YET RANGE IS SHOWN AS | | | MIN 8KW ON LOAD CALCULATIONS. | | | PLEASE VERIFY SIZE OF RANGE/OVEN AND | | | PROVIDE MIN OCP/AWG. | | | | | | 5)NOTE: PLEASE SEE PLANS AND PANEL | | | SCHEDULES BOTH INDICATE WATER HEATERS ON | | | BOTH LEVELS, HOWEVER LOAD CALCULATIONS | | | ONLY INDICATE ONE WATER HEATER?? | | | PLEASECORRELATE. | | | | | | 6)NOTE: PLEASE CORRELATE APPLIANCE LOADS | | | ON LOAD CALCULATIONS AS SHOWN ON PANEL | | | SCHEDULE. | | | PLEASE SEE PANEL SCHEDULES INDICATE SM | | | APPL AS 360VA AND 1500 VA. | | | PLEASE SEE A MIN OF 1500 VA IS REQUIRED | | | FOR "EACH" SMALL APPL CIRCUIT PROVIDED. | | | PLEASE ADJUST PANEL SCHEDULE AND LOAD | | | CALCS. | | | | | | 7)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES WASHER AS 360 VA ALSO, YET | | | LOAD CALCS INDICATE 1500 VA AS REQUIRED | | | UNDER 220.16, 220.11, 210.52 | | | | | | 8)NOTE: PLEASE SEE WHIRLPOOL TUB SHOWN | | | ON LOAD CALCUALTIONS, YET NOT ON PANEL | | | SCHEDULES? | | | | | | 9)NOTE: PLEASE SEE MISSING FRONT GFI | | | RECEPT AS REQUIRED PER 210.52E , NOT A | | | COMMENT ON FIRST REVIEW. | | | | | | 10)NOTE: PLEASE SEE ATTACHED COPY OF FS | | | 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONAL. | | | THIS IS A NOTICE ONLY GIVEN AT THIS | | | TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
11:48 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-02-14 |
Time |
11:48 |
Sent To |
P |
|
| Notes |
| 2005-02-14 00:00:00 | ******** UNSAT********* | | | | | | 1)NOTE: PLEASE SEE 210.52C1 FOR REQUIRED | | | RECETPS ALONG KITCHEN COUNTERSPACE. | | | | | | 2)NOTE: PLEASE SEE 210.8A6, ALL RECEPTS | | | SERVING KITCHEN COUNTERSPACE ARE TO BE | | | GFI/GFI PROTECTED. | | | | | | 3)NOTE: PLEASE SEE MISSING GFI FOR UPPER | | | BATH RM. 210.52D/210.11C3 | | | | | | 4)NOTE:SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | PLEASE SEE PLANS HAVE BEEN REDLINED FOR | | | MIN LOCATIONS. | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 6)NOTE: PLEASE SEE RISER SHOWS ONE METER | | | , YET PLANS INDICATES TWO? PLEASE | | | CORRELATE AND SEE ZONING FOR ANY | | | POSSIBLE COMMENTS FOR MORE THAN ONE | | | METER. | | | | | | 7)NOTE: PLEASE SEE 250.6,250.24, | | | EQUIPMNET GROUNDING CONDUCTORS ARE | | | INSTALLED AFTER THE FIRST MEANS OF DISC. | | | | | | 8)NOTE: PLEASE PROVIDE PANEL SCHEDULE(S) | | | SHOWING MIN CIRCUITS REQUIRED ALONG WITH | | | OCP AND AWG. | | | 215.5 | | | | | | 9) NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 10)NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 11)NOTE: PLEASE SEE 210.52 FOR SOME | | | RECEPTS MISSING IN RMS WHICH ARE BEING | | | REMODELED. | | | | | | 12)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 13)NOTE: PLEASE VERIFY LOCATION OF POOL | | | PANEL, APPEARS TO BE SHOWN "IN" | | | WALL/COLUMN? | | | PLEASE SEE 110.26 FOR MIN CLEARENCE. | | | | | | 14)NOTE: PLEASE SHOW ALL DISC'S REQUIRED | | | FOR A/C EQUIPMENT SHOWN. 440.11 | | | | | | 15)NOTE: PLEASE SEE MISSING GFI FOR A/C | | | EQUIPMENT. 210.63 | | | | | | 16)NOTE: PLEASE SEE "NOTE#6" OF | | | ELECTRICAL NOTES. MENTIONS ALL RECEPT | | | W/IN 5FT, TO BE GFI. PLEASE SEE THIS | | | MEASUREMENT SHOULD READ 6' , HOWEVER THE | | | "93" NEC CHANGED TO REQUIRE ALL RECEPTS | | | SERVING KITCHEN COUNTERSPACE TO BE | | | GFI/GFI PROTECTED. PLEASE SEE PREVIOUS | | | NOTE; | | | | | | PLEASE SEE MANY OF THE ABOVE ITEMS HAVE | | | BEEN REDLINED ON ONE SET OF PLANS FOR | | | AREAS OF COMMENTS. | | | | | | PLEASE REMOVE ANY/ OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING ME. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | ** ADDED NOTE: PLEASE PROVIDE ROOM | | | DESIGNATIONS ON ELECTRICAL PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-23 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-23 |
Time |
15:03 |
Sent To |
E |
|
| Notes |
| 2006-06-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-31 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-31 |
Time |
15:54 |
Sent To |
E |
|
| Notes |
| 2006-05-31 00:00:00 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-18 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-18 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2006-05-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-14 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-14 |
Time |
15:38 |
Sent To |
E |
|
| Notes |
| 2006-03-14 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-06 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-06 |
Time |
08:27 |
Sent To |
B |
|
| Notes |
| 2006-01-06 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-13 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-13 |
Time |
19:30 |
Sent To |
E |
|
| Notes |
| 2005-12-13 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
15:38 |
Sent To |
M |
|
| Notes |
| 2005-09-27 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-06 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-06 |
Time |
15:43 |
Sent To |
B |
|
| Notes |
| 2005-05-06 00:00:00 | TO "SHILL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-06 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-06 |
Time |
16:52 |
Sent To |
E |
|
| Notes |
| 2005-04-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-23 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-23 |
Time |
11:26 |
Sent To |
E |
|
| Notes |
| 2005-03-23 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-02-11 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-02-11 |
Time |
10:22 |
Sent To |
E |
|
| Notes |
| 2005-02-11 00:00:00 | TO "E" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
14:46 |
Sent To |
Z |
|
| Notes |
| 2005-02-04 00:00:00 | TO "Z"BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-28 |
Time |
12:03 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-28 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2005-09-28 00:00:00 | MECH. REVISION (AS BUILT) 9-28-05 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-23 |
Time |
08:24 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-02-23 |
Time |
08:24 |
Sent To |
B |
|
| Notes |
| 2005-02-23 00:00:00 | MECH. PLAN REVIEW. | | | | | | PROVISO:PROVIDE FOR AUX. DRAIN PAN | | | UNDER A/C UNITS IN CLOSITS.2003 FBC/M | | | 307.2.3 . | | | PAT RAFTER 561/805/6728 . | | | PLEASE CALL IF THEAR ENY QUISTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-17 |
Time |
18:30 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-02-17 |
Time |
18:30 |
Sent To |
M |
|
| Notes |
| 2005-02-17 00:00:00 | NO PLUMBING RISER DIAGRAM. UNABLE TO DO | | | PLAN REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-05 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-05 |
Time |
14:27 |
Sent To |
I |
|
| Notes |
| 2006-01-05 00:00:00 | APPROVING REVISION FOR THE REAR DECK OF | | | PROPERTY ONLY. | | | | | | NOTE: MUST PULL SEPERATE PERMIT FOR | | | FENCE/GATE/COLUMNS/WALL WITH EASEMENT | | | APPROVAL FROM THE CITY OF WEST PALM | | | UTILITY DEPT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-10 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-10 |
Time |
16:13 |
Sent To |
I |
|
| Notes |
| 2005-02-10 00:00:00 | MUST PULL SEPERATE PERMIT FOR | | | WALL/FENCE/GATE WITH UTILITY EASEMENT | | | APPROVAL FROM CITY OF WEST PALM BEACH | | | UTILITY DEPT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 |
|
|