Plan Review Details - Permit 05020193
Plan Review Stops For Permit 05020193
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-08-17 Cont ID  
Sent By shill Date 2005-08-17 Time 17:03 Rev Time 1.00
Received By shill Date 2005-08-17 Time 17:03 Sent To PC
Notes
2005-08-17 00:00:00PROVISO - PROVIDE INSTALLATION
 INSTRUCTIONS FOR CASEMENT WINDOWS AT
 INSPECTION.
  
 NOTE - THE WORK WAS COMPLETED PRIOR TO
 ISSUANCE, APPLYING FOR A PERMIT AS A
 RESULT OF A STOP WORK ORDER, NOC NOT
 EXPIRED

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-08-06 Cont ID  
Sent By shill Date 2005-08-06 Time 11:52 Rev Time 0.00
Received By shill Date 2005-08-06 Time 11:52 Sent To  
Notes
2005-08-06 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE PREVIOUS TWO LISTS IN REGARDS
 TO SHOWING COMPLIANCE WITH FBC1005.4.
 THE FLOOR PLAN SHOWING WINDOW SIZES,
 ROOM LOCATIONS, TYPE OF WINDOWS IS NO
 LONGER IN THE PACKAGE.
  
 FROM PREVIOUS REVIEW, THE FOLLOWING
 COMMENTS.AS DISCUSSED WITH CONTRACTOR,
 I WILL PRINT THE PRODUCT APPROVALS
 REQUESTED IN WRITING FOR YOU.WHEN
 RESUBMITTING, PLEASE BE SURE THAT THIS
 REQUEST STAYS IN THE PACKAGE!
  
 2.)THE COVER SHEET TO A POMA SHUTTER
 NOA WAS SUBMITTED.PLEASE PROVIDE A
 COMPLETE, LEGIBLE TEST REPORT AND
 FLORIDA STATE OR LOCAL PRODUCT APPROVAL.
  
 3.)PROVIDE A FLORIDA STATE OR LOCAL
 PRODUCT APPROVAL FOR THE WINDOW (NOA WAS
 PROVIDED), TWO COPIES.
  
 4.)TEST REPORT AND FLORIDA STATE OR
 LOCAL PRODUCT APPROVAL REQUIRED FOR THE
 MULLIONS.
  
 PRODUCT APPROVALS ARE AVAILABLE AT
 WWW.FLORIDABUILDING.ORG.
  
 5.)THE APPLICATION IS NO LONGER IN THE
 PACKAGE.
  
 6.)AS DISCUSSED, PLEASE COMPLETE THE
 ATTACHEDHURRICANE SHUTTER INSTALLATION
 SCHEDULE AS PER CITY POLICY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-04-06 Cont ID  
Sent By shill Date 2005-04-06 Time 08:57 Rev Time 0.50
Received By shill Date 2005-04-06 Time 08:57 Sent To PC
Notes
2005-04-06 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)SEE THE PREVIOUS LIST, ITEM #7.
 EMERGENCY EGRESS REQUIRED FOR BEDROOMS
 FBC1005L.4.A SINGLE HUNG 37X50 5/8"
 DOES NOT COMPLY.PROVIDE A PLAN SHOWING
 BEDROOM LOCATIONS AND SHOW HOW EMERGENCY
 EGRESS REQUIREMENTS WILL BE MET.
  
 2.)THE COVER SHEET TO A POMA SHUTTER
 NOA WAS SUBMITTED.PLEASE PROVIDE A
 COMPLETE, LEGIBLE TEST REPORT AND
 FLORIDA STATE OR LOCAL PRODUCT APPROVAL.
  
 3.)PROVIDE A FLORIDA STATE OR LOCAL
 PRODUCT APPROVAL FOR THE WINDOW (NOA WAS
 PROVIDED), TWO COPIES.
  
 4.)TEST REPORT AND FLORIDA STATE OR
 LOCAL PRODUCT APPROVAL REQUIRED FOR THE
 MULLIONS.
  
 PRODUCT APPROVALS ARE AVAILABLE AT
 WWW.FLORIDABUILDING.ORG.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-09 Cont ID  
Sent By shill Date 2005-02-09 Time 11:15 Rev Time 1.00
Received By shill Date 2005-02-09 Time 10:33 Sent To PC
Notes
2005-02-09 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)FLOOR LEVELING IS ON THE PLAN,
 PLAN
 SPECIFIES SHUTTERS.NEITHER IS ON THE
 APPLICATION.PLEASE PROVIDE A
 REASONABLE VALUE FOR THE JOB (NOT THE
 VALUE OF YOUR SERVICES; VALUE IS TO
 INCLUDE MATERIALS AND LABOR AS A PERMIT
 WAS NOT APPLIED FOR PREVIOUSLY FOR THE
 WINDOWS).
  
  
 2.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 3.)AS PER CONVERSATION WITH
 CONTRACTOR, WINDOWS WERE INSTALLED
 (APPARENTLY WITHOUT A PERMIT) IMPROPERLY
 BY OTHERS.PLEASE PROVIDE TEST REPORTS
 AND FLORIDA OR LOCAL PRODUCT APPROVALS
 FOR THE FOLLOWING, AS PER THE PLAN:
 SINGLE HUNG WINDOWS
 MULLIONS
 IMPACT PROTECTION (UNLESS WINDOWS ARE
 IMPACT GLASS)
 FIXED WINDOW
  
 4.)PROVIDE A LEGIBLE SEAL,
 FAC61G1-15.
  
 5.)THE STRUCTURAL NOTES #13 AND BUCK
 DETAIL CONFLICT.PLEASE PROVIDE AN
 ATTACHMENT DETAIL OR SPEC WITH SPACING.
 (CAN'T HAVE 1 1/4" EMBEDMENT WITH A 2
 1/4" TAPCON ON A 2X4 BUCK.)
  
 6.)THE WALL SECTION SHOWS SLAB ON
 GRADE, A NOTE ON THE PLAN STATES 12"
 MINUMUM FROM GRADE TO JOIST.CLARIFY.
  
 7.)THE PLAN SHOWS A 37X50 5/8" S/H AS
 AN EGRESS WINDOW.THIS DIMENSION DOES
 NOT NORMALLY MEET EMERGENCY EGRESS
 REQUIREMENTS FBC1005.4.CLARIFY.
  
 8.)THE TEST REPORT PROVIDED WAS FOR A
 HORIZONTAL SLIDER, IMPACT.THE PLAN
 SPECIFIES SINGLE HUNG.BOTH SHOULD BE
 CONSISTENT.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-27 Cont ID  
Sent By adarroug Date 2005-07-27 Time 08:35 Rev Time 0.00
Received By adarroug Date 2005-07-27 Time 08:35 Sent To B
Notes
2005-07-27 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-30 Cont ID  
Sent By adarroug Date 2005-03-30 Time 13:46 Rev Time 0.00
Received By adarroug Date 2005-03-30 Time 13:46 Sent To B
Notes
2005-03-30 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-02-03 Cont ID  
Sent By mjacobs Date 2005-02-03 Time 07:45 Rev Time 0.00
Received By mjacobs Date 2005-02-03 Time 07:45 Sent To B
Notes
2005-02-03 00:00:00TO "MISC" BOX.