|
 |
 |
 |
 |
 |
Plan Review Details - Permit 05020170
| Plan Review Stops For Permit 05020170 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-15 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-04-15 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-28 |
Time |
13:45 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-28 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-07 |
Time |
12:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-07 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1}THERE IS A NOTE ON THE PLAN THAT | | | STATES "MAIN BREAKER AND ANOTHER THAT | | | SAYS MAIN LUG, PLEASE CLARIFY. | | | | | | 2} PROVIDE A LOAD CALCULATION FOR THE | | | EXISTING SERVICE AND INDICATE THE SIZE | | | OF SAME. SHOW CALCS FOR THE 150 AMP | | | PANEL ON PLAN. | | | | | | 3} THE EXIT LIGHTS SHOWN ON THE PANEL | | | SCHEDULE CIRCUIT #7, AND LIGHTING ON | | | OTHER CIRCUITS DO NOT SEEM TO COMPLY | | | WITH ARTICLE 700.18, ALSO 700.12(E). | | | PLEASE SHOW COMPLIANCE, USE A FLOOR PLAN | | | INDICATING LIGHT CIRCUIT NUMBERS IF | | | NECESSARY. | | | | | | 4} THE NOTE STATING THE LOAD CENTER | | | LOCATION ON THE 2ND FLOOR SEEMS TO | | | INDICATE THE PANEL BEING REFED IS ON A | | | DIFFERENT LEVEL. IF NEW CONDUIT IS | | | PENETRATING FIRE SEPARATIONS, SHOW | | | STOPPING METHOD. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL, | | | OR IF THE CONTRACTOR WOULD LIKE A | | | MEETING TO DISCUSS ANY OF THE COMMENTS, | | | CALL | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-11 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-11 |
Time |
11:03 |
Sent To |
E |
|
| Notes |
| 2005-04-11 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-18 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
16:24 |
Sent To |
E |
|
| Notes |
| 2005-02-18 00:00:00 | TO BTROBAUG DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-03 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-03 |
Time |
08:48 |
Sent To |
E |
|
| Notes |
| 2005-02-03 00:00:00 | TO "E" BOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |