| Plan Review Stops For Permit 05020155 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-06-27 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-06-27 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2007-06-27 11:38:17 | REVISION FOR KNEE WALL , UPSTAIRS BATH. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-10-17 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-10-17 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2006-10-17 15:19:11 | | | | | | | | | | REVISION TO ENCLOSE CABANA FOR STORAGE ONLY, OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-08-07 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-08-07 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | | | | | | | "PROVISO" | | | ------- | | | | | | | | | | | | 1] | | | PERMITTED SETS OF PLANS ARE REQUIRED TO | | | BE STAMPED BY THE COUNTY IMPACT OFFICE. | | | (SQUARE FOOTAGE IS DIFFERENT FROM | | | STAMPED SETS SUBMITTED) | | | | | | 2) | | | ENGINEERS GRADE BEAM AND COLUMN SK1 AND | | | SK2 SHALL BE SIGNED AND SEALED. | | | | | | 3) | | | ENERGY EFFICIENCY FORM 600A-2004 SHALL | | | BE SIGNED AND DATED BY OWNERS/AGENT. | | | | | | | | | | | | | | | | | | | | | L. MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-07-18 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-07-18 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | | | | | | | | | | | | | BUILDING REVIEW COMMENTS | | | ------- ------ -------- | | | | | | | | | | | | 1) | | | SUBMIT ALL PRODUCT APPROVAL REPORTS FOR | | | NEW WINDOWS, DOORS AND ROOF COVER. | | | | | | 2) | | | PROVIDE ENGINEER'S STRUCTURAL PAGES | | | REFERRED TO THROUGHOUT THE DRAWINGS. | | | INCLUDE DETAIL FOR NEW STEEL COLUMN AT | | | PUB ROOM. | | | | | | 3) | | | SUBMIT PLANS TO PALM BEACH COUNTY | | | IMPACT FEE OFFICE FOR REVIEW, PROVIDE | | | RECEIPT AND STAMPED PLANS BACK TO THE | | | CITY. | | | | | | 4) | | | PROVIDE ENERGY EFFICIENCY REPORT. | | | | | | 5) | | | ADDITIONAL FEES OWED FOR INCREASE IN | | | CONSTRUCTION VALUE. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-04-05 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-04-05 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-25 |
Time |
14:06 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-04-01 |
Time |
08:28 |
Sent To |
Z |
|
| Notes |
| 2005-02-25 00:00:00 | DENIED | | | | | | 1.SUBMIT 2 COMPLETE SETS OF QUALITY | | | ASSURANCE PRODUCT APPROVALS FOR PGT | | | SH-701 AND PW-701 ALSO FOR STRAPS AND | | | TIE-DOWNS. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2.SUBMIT INFORMATION ON TYPE OF SIDING | | | USED.PRODUCT APPROVALS MAY BE REQUIRED | | | DEPENDING ON THE TYPE OF SIDING USED. | | | | | | 3.IF YOU WANT TO REMOVE THE ELEVATOR, | | | PLEASE CROSS OF ALL INFORMATION FOR THE | | | ELEVATOR. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-22 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-22 |
Time |
10:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-17 |
Time |
12:20 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2007-05-17 |
Time |
09:12 |
Sent To |
B |
|
| Notes |
| 2007-05-17 12:20:45 | | | | | | | REVISION DENIED | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE 350 MCM SERVICE CONDUCTORS MUSTTERMINATE IN | | | 350 AMP OVERCURRENT PROTECTION. 400 AMP IS ON THE PLAN. | | | SEE 240.6,310.15(B)(6) AND 230.90(A). | | | | | | 2} PLEASE PROVIDE A PANEL SCHEDULE FOR THE 400 AMP | | | DISCONNECT SO THE OCP FOR THE 200 AMP FEEDERS CAN BE | | | REVIEWED. | | | | | | 3}PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 4}AN EQUIPMENT GROUNDING CONDUCTOR MUST BE INSTALLED | | | FROM THE FIRST MEANS OF DISCONNECT TO THE PANEL PER | | | 250.118, SIZED PER 250.122. THEY ARE OMITTED FROM THE | | | PLAN. | | | | | | 5} THE EQUIPMENT GROUNDING CONDUCTOR MUST COMPLY WITH | | | 250.66, 1/0 CU. MINIMUM. | | | | | | 6} THE FEED TO PANEL "C" IS NOT LISTED ON PANEL "B" | | | SCHEDULE. VERIFYTHE FEED IS 2/0 CONDUCTORS TO THE 100 | | | AMP SUB PANEL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-08-17 |
Time |
10:22 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2006-08-17 |
Time |
10:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-08-03 |
Time |
08:01 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2006-08-03 |
Time |
08:01 |
Sent To |
M |
|
| Notes |
| 2006-08-03 00:00:00 | ON PAGE E1 PANEL A ON RISER IS IN GARAGE | | | AND ON PLAN IT IS IN THE PANTRY OFF THE | | | KITCHEN. | | | | | | THE PANEL IN THE GARAGE THAT COMES OFF | | | THE GUTTER SHOWN AS PANEL "A" DOES IT | | | HAVE A MAIN BREAKER?THE PLAN DOES NOT | | | SHOW IT!!!!!!!!!!! | | | | | | THE GUTTER EXISTING OR NOT MUST BE SIZED | | | INACCORDANCE WITH THE CODE. | | | | | | NEW OFFICE ON SECOND FLOOR WILL REQUIRE | | | ARC FAULT PROTECTION BECAUSE IT COULD BE | | | TURNED INTO A BEDROOM IF THIS OWNER | | | SELLS. PLEASE INDICATE ALL ARC FAULT | | | BREAKERS IN THE PANEL(S). | | | | | | NO WIRE SIZES SHOWN ON RISER TO GUTTER | | | AND PANEL "A" | | | | | | STEAM UNIT? UNIT SHOWS 5000W THIS CAN | | | NOT BE PUT ON A 20A BREAKER. | | | | | | PANEL SCHEDULE FOR "A SHOWS 15,000 WATTS | | | ON THE GENERAL LIGHTING CIRCUITS. | | | | | | QUESTIONS 644-7291JAKE | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-06 |
Time |
15:24 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-07-06 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2006-07-06 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE A LOAD CALCULATION PER | | | 220.31, INCLUDE ADDED LOADS. SHOW | | | ELEVATOR CIRCUITING AS WELL. | | | | | | 2} SUBMIT A PANEL SCHEDULE PER 408.4 NEC | | | AND 106.3.5.4(8) FBC, ALL PANELS. | | | | | | 3} THE RISER INDICATES A NEW METER, SHOW | | | THE GROUNDING ELECTRODE SYSTEM AND SIZE | | | PER 250.50 AND 250.66. | | | | | | 4} PLACE THE GUTTER, SHOWN ON THE RISER, | | | ON THE PLAN AT LOCATION. | | | | | | 5} INDICATE WHAT THE 200 AMP DISCONNECT | | | ON THE RISER AND LOCATED IN THE GARAGE, | | | SERVES. SHOW CONNECTIONS ON RISER. | | | | | | 6} THE DISCONNECTING MEANS MUST COMPLY | | | WITH 225.32. IT IS UNCLEAR WHETHER THE | | | FEEDERS TO THE PANELS ARE UNDER THE | | | SLAB. IF NOT A DISCONNECT WOUD BE | | | REQUIRED AT THE METER, SINCE THE PANELS | | | ARE NOT BACK TO BACK, THEREFORE NOT AT | | | THE NEAREST POINT OF ENTRANCE. | | | | | | 7} PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE SERVICE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 8} 210.63 HEATING, AIR-CONDITIONING, AND | | | REFRIGERATION EQUIPMENT OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR | | | 20-AMPERE-RATED RECEPTACLE OUTLET SHALL | | | BE INSTALLED AT AN ACCESSIBLE LOCATION | | | FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE SHALL BE | | | LOCATED ON THE SAME LEVEL AND WITHIN 7.5 | | | M (25 FT) OF THE HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE OUTLET SHALL | | | NOT BE CONNECTED TO THE LOAD SIDE OF THE | | | EQUIPMENT DISCONNECTING MEANS. | | | | | | 9} PLEASE SEE ALL SMOKE DETECTORS MUST | | | BE INTERCONNECTED, WITH A BATTERY BACK | | | UP, PER R313 FBC. ALSO ARC FAULT PER | | | 210.12. PLEASE LOCATE DETECTORS ON THE | | | PLAN SO LOCATION COMPLIANCE PER 313.1 | | | CAN BE REVIEWED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-04-01 |
Time |
08:28 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-04-01 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-02-15 |
Time |
09:07 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-02-15 |
Time |
09:06 |
Sent To |
M |
|
| Notes |
| 2005-02-15 00:00:00 | NEED TO SHOW SIZE OF MOTOR FOR ELEVATOR | | | | | | SHOW LOCATION OF ELEVATOR EQUIPMENT. | | | | | | SHOW BRANCH CIRCUIT NUMBERS FOR THE | | | ELEVATOR CIRCUITS. | | | | | | NEED LOCATION OF PANEL FOR BRANCH | | | CIRCUITS. | | | | | | SHOW SIZE OF SERVICE MAIN. IF SMALL | | | SHOW LOAD CALCULATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-14 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-14 |
Time |
09:37 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
14:15 |
Sent To |
E |
|
| Notes |
| 2007-05-08 14:16:16 | TO "JLEAHY" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-10 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-10 |
Time |
09:57 |
Sent To |
B |
|
| Notes |
| 2006-10-10 09:57:41 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-10-06 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-04 |
Time |
16:46 |
Sent To |
Z |
|
| Notes |
| 2006-10-04 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-10-06 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-11 |
Time |
11:18 |
Sent To |
Z |
|
| Notes |
| 2006-08-11 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-01 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
11:08 |
Sent To |
E |
|
| Notes |
| 2006-08-01 00:00:00 | TO "JLEAHY" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-29 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-29 |
Time |
16:59 |
Sent To |
B |
|
| Notes |
| 2006-06-29 00:00:00 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-25 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-25 |
Time |
11:17 |
Sent To |
Z |
|
| Notes |
| 2005-03-25 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-03 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-03 |
Time |
08:04 |
Sent To |
E |
|
| Notes |
| 2005-02-03 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-03 |
Time |
10:57 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-08-03 |
Time |
10:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-07 |
Time |
15:30 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-07-07 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | *** DENIED *** | | | 1) PLEASE SUBMIT MECHANICAL PLANS | | | SHOWING NEW A/C SYSTEM AND DUCT WORK. | | | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS, | | | PER FBC 13-600.3.A . | | | | | | 3) PLEASE SUBMITMANUAL J CALCULATIONS, | | | PER 2004 FBC 13-607.1.ABC.1 . | | | | | | 4) PLEASE SUBMIT DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR WINE COOLER EQUIPMENT. | | | | | | 5) PLEASE SUBMIT DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR KITCHEN HOOD IF | | | EXHAUSTED BY DUCTS. | | | | | | NOTE: THIS MAY BE DONE AS A REVISION TO | | | MACHANICAL PERMIT #06021326 BUT MUST BE | | | DONE BEFORE BUILDING PERMIT REVISION | | | REVIEWS CAN BE COMPLETE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-16 |
Time |
09:11 |
Rev Time |
0.15 |
| Received By |
prafter |
Date |
2005-02-16 |
Time |
09:11 |
Sent To |
B |
|
| Notes |
| 2005-02-16 00:00:00 | | | | NO A/C MECH. WORK REFLECTED ON PLANS OR | | | JOB DESCRIPTION. | | | | | | PAT RAFTER 561/805/6728 . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-07 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-07 |
Time |
07:33 |
Sent To |
B |
|
| Notes |
| 2006-07-07 00:00:00 | REVISION; | | | ADDED ONE AND 1/2 BATHROOMS OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-01 |
Time |
15:53 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-10-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-10-06 |
Time |
10:19 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-08-07 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-08-07 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | SEE PLANS FOR APPROVAL |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-06 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-06 |
Time |
09:58 |
Sent To |
B |
|
| Notes |
| 2006-07-06 00:00:00 | DENIED, (REVISION) | | | 1. NEED TO SUBMIT TWO COPY OF THE | | | CURRENT SURVEYS SHOWING THE LOCATION OF | | | THE WORK THAT IS SHOWN ON THE SITEPLAN. | | | 2. MUST SHOW THE A/C UNIT ON THE TWO | | | COPY OF SURVEYS, AS WELL SITEPLANS. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-29 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-29 |
Time |
10:04 |
Sent To |
B |
|
| Notes |
| 2005-03-29 00:00:00 | APPROVING ADDITION - MASTER BEDROOM & | | | BALCONY MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-01 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-01 |
Time |
12:13 |
Sent To |
B |
|
| Notes |
| 2005-03-01 00:00:00 | DENIED, | | | 1. MUST PROVIDE A FULL SITEPLAN TO SCALE | | | SHOWING THE EXTENDED MASTER BEDROOM & | | | CLOSING EXISTING BALCONY WITH SETBACKS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 | | | | | | RETURNED PLANS TO LUIS M MM |
|
|