Plan Review Details - Permit 05011527
Plan Review Stops For Permit 05011527
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-03-07 Cont ID  
Sent By shill Date 2005-03-07 Time 16:27 Rev Time 1.00
Received By shill Date 2005-03-07 Time 16:27 Sent To FIRE
Notes
2005-03-07 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)DECLARE AN OCCUPANCY, FBC CHAPTER
 3.
  
 2.)SEE PREVIOUS COMMENTS 3, 4, 5.
 EITHER NOT ADDRESSED OR NOT ADDRESSED
 PROPERLY.
  
 3.)BOTTOM DISTANCE OF RAIL TO SLAB IS
 SHOWN AS 3", NOT COMPLIANT WITH
 FBC1015.3. (REJECT A 2" OBJECT).
  
 4.)SEE ATTACHED FS553.80(2)(B).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-03 Cont ID  
Sent By shill Date 2005-02-03 Time 11:48 Rev Time 0.50
Received By shill Date 2005-02-03 Time 11:48 Sent To PC
Notes
2005-02-03 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
 CORRECTIONS APPLY TO 05011528, 05011529
  
 1.)THE TITLE BLOCK IS TO INCLUDE THE
 PRINTED LICENSE NUMBER OF THE PERSON
 SEALING THE DOCUMENT FAC61G15-23.002.
  
 2.)SPECIFY ANCHOR DISTANCE FROM EDGE
 OF SLAB.
  
 3.)GUARDRAILS ARE TO COMPLY WITH
 FBC1608.2.2; SPECIFY (DO NOT JUST
 PROVIDE CODE NUMBER).
  
 4.)GUARDRAILS ARE TO COMPLY WITH
 FBC1015.3.A 4" OPENING BETWEEN
 PICKETS
 DOES NOT COMPLY.SPECIFY DISTANCE OF
 BOTTOM RAIL FROM SLAB.
  
 5.)SPEC STATES "1/2" X 6" WEDGE
 ANCHORS AT FRONT AND BACK".BACK OF
 WHAT?THE BACK OF THE RAILING TUBE IS
 AGAINST THE SLAB.IF I AM
 MISUNDERSTANDING THE SPECIFICATION
 PLEASE PROVIDE A PLAN VIEW FOR
 CLARIFICATION.

Review Stop E ELECTRICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-03-22 Cont ID  
Sent By nmccray Date 2005-03-22 Time 10:00 Rev Time 0.00
Received By nmccray Date 2005-03-22 Time 10:00 Sent To  
Notes
2005-03-22 00:00:00COMPLY WITH NFPA 101 CH 7.2.2.4.5 GUARD
 RAILS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-23 Cont ID  
Sent By adarroug Date 2005-02-23 Time 14:01 Rev Time 0.00
Received By adarroug Date 2005-02-23 Time 14:01 Sent To B
Notes
2005-02-23 00:00:00TO "SHILL" RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-31 Cont ID  
Sent By mjacobs Date 2005-01-31 Time 14:34 Rev Time 0.00
Received By mjacobs Date 2005-01-31 Time 14:34 Sent To B
Notes
2005-01-31 00:00:00TO "MISC" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved