Plan Review Details - Permit 05011527
| Plan Review Stops For Permit 05011527 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-07 |
Time |
16:27 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-07 |
Time |
16:27 |
Sent To |
FIRE |
|
| Notes |
| 2005-03-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)DECLARE AN OCCUPANCY, FBC CHAPTER | | | 3. | | | | | | 2.)SEE PREVIOUS COMMENTS 3, 4, 5. | | | EITHER NOT ADDRESSED OR NOT ADDRESSED | | | PROPERLY. | | | | | | 3.)BOTTOM DISTANCE OF RAIL TO SLAB IS | | | SHOWN AS 3", NOT COMPLIANT WITH | | | FBC1015.3. (REJECT A 2" OBJECT). | | | | | | 4.)SEE ATTACHED FS553.80(2)(B). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-03 |
Time |
11:48 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-02-03 |
Time |
11:48 |
Sent To |
PC |
|
| Notes |
| 2005-02-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | CORRECTIONS APPLY TO 05011528, 05011529 | | | | | | 1.)THE TITLE BLOCK IS TO INCLUDE THE | | | PRINTED LICENSE NUMBER OF THE PERSON | | | SEALING THE DOCUMENT FAC61G15-23.002. | | | | | | 2.)SPECIFY ANCHOR DISTANCE FROM EDGE | | | OF SLAB. | | | | | | 3.)GUARDRAILS ARE TO COMPLY WITH | | | FBC1608.2.2; SPECIFY (DO NOT JUST | | | PROVIDE CODE NUMBER). | | | | | | 4.)GUARDRAILS ARE TO COMPLY WITH | | | FBC1015.3.A 4" OPENING BETWEEN | | | PICKETS | | | DOES NOT COMPLY.SPECIFY DISTANCE OF | | | BOTTOM RAIL FROM SLAB. | | | | | | 5.)SPEC STATES "1/2" X 6" WEDGE | | | ANCHORS AT FRONT AND BACK".BACK OF | | | WHAT?THE BACK OF THE RAILING TUBE IS | | | AGAINST THE SLAB.IF I AM | | | MISUNDERSTANDING THE SPECIFICATION | | | PLEASE PROVIDE A PLAN VIEW FOR | | | CLARIFICATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-03-22 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-03-22 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | COMPLY WITH NFPA 101 CH 7.2.2.4.5 GUARD | | | RAILS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-23 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-23 |
Time |
14:01 |
Sent To |
B |
|
| Notes |
| 2005-02-23 00:00:00 | TO "SHILL" RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
| 2005-01-31 00:00:00 | TO "MISC" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |