Plan Review Details - Permit 05011510
Plan Review Stops For Permit 05011510
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-03-17 Cont ID  
Sent By btrobaug Date 2005-03-17 Time 11:32 Rev Time 0.50
Received By btrobaug Date 2005-03-17 Time 10:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-02-28 Cont ID  
Sent By btrobaug Date 2005-02-28 Time 14:34 Rev Time 0.25
Received By btrobaug Date 2005-02-28 Time 14:21 Sent To M
Notes
2005-02-28 00:00:00 
 THE ENGINEER OF RECORD MUST SEAL,SIGN
 AND DATE PLANS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-02-17 Cont ID  
Sent By btrobaug Date 2005-02-11 Time 15:53 Rev Time 0.50
Received By btrobaug Date 2005-02-11 Time 15:05 Sent To M
Notes
2005-02-11 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 SHEET E-1 INDICATES A 40KW GENERATOR AND
 E-2 INDICATES 100KW, PLEASE CORRELATE.
  
 SUPPLY MFGR SPECIFICATION FOR THE
 GENERATOR.
  
 GIVE SPECIFICATIONS FOR PANEL "A"(AMPS,
 VOLTS RATING, MAIN BKR.OR MLO)ETC.
  
 THE VALUE ON THE APPLICATION MUST
 REFLECT THE COST OF ALL MATERIAL AND
 LABOR IN THE SCOPE OF WORK TO BE DONE.
 THIS INCLUDES THE GENERATOR AND RELATED
 EQUIPMENT, REGARDLESS OF WHO FURNISHES
 SAME. FBC 104.6.5.
  
 A GAS PERMIT IS REQUIRED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-03-05 Cont ID  
Sent By kstevens Date 2005-03-05 Time 08:00 Rev Time 0.33
Received By kstevens Date 2005-03-05 Time 08:00 Sent To Z
Notes
2005-03-05 00:00:00 
  
 SEPARATE PLANS/PERMIT REQUIRED BY
 LICENSED CONTRACTOR FOR GENERATOR. GAS
 INDICATED AS FUEL CONSUMPTION
  
  
  
  
  
  
  
 SEPARATE PLANS/PERMIT REQUIRED BY
 LICENSED CONTRACTOR FOR GENERATOR. GAS
 INDICATED AS FUEL CONSUMPTION
  
  
  
  
  
  
  
 .

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-08 Cont ID  
Sent By adarroug Date 2005-03-08 Time 09:00 Rev Time 0.00
Received By adarroug Date 2005-03-08 Time 09:00 Sent To E
Notes
2005-03-08 00:00:00TO "BT" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-18 Cont ID  
Sent By adarroug Date 2005-02-18 Time 16:26 Rev Time 0.00
Received By adarroug Date 2005-02-18 Time 16:26 Sent To E
Notes
2005-02-18 00:00:00TO BT DESK/RESUB
 WITH PLAN#05020170
 MUST BE SEEN BY "Z",AND "M"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-04 Cont ID  
Sent By adarroug Date 2005-02-04 Time 09:31 Rev Time 0.00
Received By adarroug Date 2005-02-04 Time 09:31 Sent To E
Notes
2005-02-04 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-31 Cont ID  
Sent By mjacobs Date 2005-01-31 Time 12:43 Rev Time 0.00
Received By mjacobs Date 2005-01-31 Time 12:43 Sent To Z
Notes
2005-01-31 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2005-03-01 Cont ID  
Sent By prafter Date 2005-03-01 Time 11:09 Rev Time 0.35
Received By prafter Date 2005-03-01 Time 11:09 Sent To P
Notes
2005-03-01 00:00:00NO MECHANICAL REVIEW REQUIRED FOR
 NATURAL GAS GENERATOR, SENT TO PLUMBING

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-02-15 Cont ID  
Sent By prafter Date 2005-02-15 Time 07:54 Rev Time 0.30
Received By prafter Date 2005-02-15 Time 07:54 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-03-07 Cont ID  
Sent By mmclean Date 2005-03-07 Time 12:42 Rev Time 0.00
Received By mmclean Date 2005-03-07 Time 12:42 Sent To  
Notes
2005-03-07 00:00:00APPROVING SETBACK OF 5FT FROM PROPERTY
 LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-02-03 Cont ID  
Sent By mmclean Date 2005-02-03 Time 11:56 Rev Time 0.00
Received By mmclean Date 2005-02-03 Time 11:56 Sent To I
Notes
2005-02-03 00:00:00DENIED,
 1. MUST PROVIDE THE SETBACKS FOR SLAB
 AND GENERATOR.CALLED CONTR PHONE
 DISCONNECT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 CONSTRUCTION SERVICES
 805-6720