| Plan Review Stops For Permit 05011510 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-17 |
Time |
11:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-03-17 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-28 |
Time |
14:34 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2005-02-28 |
Time |
14:21 |
Sent To |
M |
|
| Notes |
| 2005-02-28 00:00:00 | | | | THE ENGINEER OF RECORD MUST SEAL,SIGN | | | AND DATE PLANS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-11 |
Time |
15:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-11 |
Time |
15:05 |
Sent To |
M |
|
| Notes |
| 2005-02-11 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | SHEET E-1 INDICATES A 40KW GENERATOR AND | | | E-2 INDICATES 100KW, PLEASE CORRELATE. | | | | | | SUPPLY MFGR SPECIFICATION FOR THE | | | GENERATOR. | | | | | | GIVE SPECIFICATIONS FOR PANEL "A"(AMPS, | | | VOLTS RATING, MAIN BKR.OR MLO)ETC. | | | | | | THE VALUE ON THE APPLICATION MUST | | | REFLECT THE COST OF ALL MATERIAL AND | | | LABOR IN THE SCOPE OF WORK TO BE DONE. | | | THIS INCLUDES THE GENERATOR AND RELATED | | | EQUIPMENT, REGARDLESS OF WHO FURNISHES | | | SAME. FBC 104.6.5. | | | | | | A GAS PERMIT IS REQUIRED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2005-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-05 |
Time |
08:00 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-03-05 |
Time |
08:00 |
Sent To |
Z |
|
| Notes |
| 2005-03-05 00:00:00 | | | | | | | SEPARATE PLANS/PERMIT REQUIRED BY | | | LICENSED CONTRACTOR FOR GENERATOR. GAS | | | INDICATED AS FUEL CONSUMPTION | | | | | | | | | | | | | | | | | | | | | | | | SEPARATE PLANS/PERMIT REQUIRED BY | | | LICENSED CONTRACTOR FOR GENERATOR. GAS | | | INDICATED AS FUEL CONSUMPTION | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-08 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-08 |
Time |
09:00 |
Sent To |
E |
|
| Notes |
| 2005-03-08 00:00:00 | TO "BT" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-18 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
16:26 |
Sent To |
E |
|
| Notes |
| 2005-02-18 00:00:00 | TO BT DESK/RESUB | | | WITH PLAN#05020170 | | | MUST BE SEEN BY "Z",AND "M" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
09:31 |
Sent To |
E |
|
| Notes |
| 2005-02-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
12:43 |
Sent To |
Z |
|
| Notes |
| 2005-01-31 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-03-01 |
Time |
11:09 |
Rev Time |
0.35 |
| Received By |
prafter |
Date |
2005-03-01 |
Time |
11:09 |
Sent To |
P |
|
| Notes |
| 2005-03-01 00:00:00 | NO MECHANICAL REVIEW REQUIRED FOR | | | NATURAL GAS GENERATOR, SENT TO PLUMBING |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-15 |
Time |
07:54 |
Rev Time |
0.30 |
| Received By |
prafter |
Date |
2005-02-15 |
Time |
07:54 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-07 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-07 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2005-03-07 00:00:00 | APPROVING SETBACK OF 5FT FROM PROPERTY | | | LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-03 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-03 |
Time |
11:56 |
Sent To |
I |
|
| Notes |
| 2005-02-03 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE SETBACKS FOR SLAB | | | AND GENERATOR.CALLED CONTR PHONE | | | DISCONNECT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 |
|
|