| Plan Review Stops For Permit 05011482 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-19 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-19 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | REVISED S1, A4 DATED 6/5/6 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-04-12 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-04-12 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | PROVISO - SEPARATE PERMIT DOORS, | | | WINDOWS, ROOF |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-02-16 |
Time |
10:36 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2006-02-16 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)WHEN RESUBMITTING, PROVIDE TWO | | | COLLATED SETS.REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED. | | | | | | PLEASE PREPARE TWO COLLATED STAPLED SETS | | | FOR PERMIT ISSUANCE.YOUR SITE PLAN, | | | MECHANICAL SHEET, ELECTRIC SHEET ARE IN | | | ONE PACKAGE MARKED "OLD" AND THE | | | ARCHITECTURAL AND STRUCTURAL SHEETS ARE | | | IN ANOTHER INCOMPLETE SET. | | | | | | 2.)ADDRESSED. | | | | | | 3.)SEE PREVIOUS LISTS.FLORIDA STATE | | | OR LOCAL PRODUCT APPROVAL REQUIRED IN | | | ADDITION TO THE NOAS PROVIDED.ANY | | | ITEMS NOT SUBMITTED PROPERLY PRIOR TO | | | ISSUANCE WILL REQUIRE SEPARATE PERMITS. | | | | | | NOT ADDRESSED.FLORIDA STATE PRODUCT | | | APPROVALS MAY BE AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG | | | | | | NEW COMMENT | | | | | | 4.)THE NOC HAS EXPIRED (OVER 90 DAYS | | | WITHOUT COMMENCING WORK), FS713.13(2). | | | PLEASE REFILE THE NOC. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-12 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-12-12 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2005-12-12 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)WHEN RESUBMITTING, PROVIDE TWO | | | COLLATED SETS.REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED. | | | | | | 2.)THE PACKAGE MARKED "CONTRACTOR | | | COPY" IS MISSING FROM THE PACKAGE.THIS | | | MUST STAY IN THE PACKAGE UNTIL ISSUANCE. | | | PROVIDE A SECOND COPY OF THE REQUIRED | | | DOCUMENTS. | | | | | | 3.)SEE PREVIOUS LISTS.FLORIDA STATE | | | OR LOCAL PRODUCT APPROVAL REQUIRED IN | | | ADDITION TO THE NOAS PROVIDED.ANY | | | ITEMS NOT SUBMITTED PROPERLY PRIOR TO | | | ISSUANCE WILL REQUIRE SEPARATE PERMITS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-27 |
Time |
16:35 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-08-27 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2005-08-27 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE NOC IS EXPIRED, OVER 90 DAYS | | | WITHOUT COMMENCING WORK, FS713.13(2). | | | | | | 2.)THE BEDROOM WINDOW NOW SHOWS A | | | 53X50 SINGLE OPENING CASEMENT.THIS IS | | | A DOUBLE OPENING; SEE PRODUCT APPROVAL. | | | PROVIDE INFORMATION FROM THE | | | MANUFACTURER SHOWING COMPLIANCE WITH | | | FBC1005.4.3.THIRD REQUEST. | | | | | | 3.)SHEET A2 TYPICAL ROOF NAILING NOTE | | | HAS BEEN REVISED TO 6" OC THROUGHOUT. | | | THIS IS STILL NONCOMPLIANT FOR ZONE 3. | | | THIRD CORRECTION. | | | | | | 4.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED IN ADDITION TO THE | | | NOAS PROVIDED, FAC9B72L. | | | WWW.FLORIDABUILDING.ORG. | | | | | | A 4X FEE HAS BEEN CHARGED AS REQUIRED BY | | | FS553.80(2)(B). | | | | | | WHEN RESUBMITTING, PLEASE REPLACE SHEETS | | | WHICH HAVE CHANGED AND SUBMIT OLD SHEETS | | | SEPARATELY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-08-05 |
Time |
13:44 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-08-05 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
| 2005-08-05 00:00:00 | PERMIT #05011482 | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 | | | | | | 3.) PROVIDE A COPY OF A SURVEY FOR THIS | | | PROPERTY. | | | | | | 4.) SEE PREVIOUS LIST, ITEM #6. | | | EMERGENCY EGRESS REQUIRED, FBC | | | 1005.4.SHOW WINDOW SIZE AND TYPE FOR | | | OFFICE/GUEST BEDROOM.A NOTE WAS PLACED | | | ON THE PLAN "NEW WINDOWS TO BE EGRESS". | | | THIS DID NOT ADDRESS THE REQUEST FOR A | | | WINDOW SIZE AND TYPE TO SHOW COMPIANCE | | | WITH FBC1005.4. | | | | | | 5.) SEE PREVIOUS LIST, ITEM #7, THE ROOF | | | SHEATHING NAILING NOTE (SHEET SP) | | | CONFLICTS WITH 2-A4 AND IS | | | NOT COMPLIANT FOR ZONE 4, FBC*TABLE | | | 2306.1.SHEET SP HAS BEEN REVISED TO | | | HAVE A NAILING PATTERN OF 12/6, A2 IS | | | 6/6 EXCEPT FOR GABLES AT 4/6.THERE ARE | | | NO GABLES ON THE PLAN.THE NAILING | | | SHOULD BE A MINIMUM OF 6/6 IN ZONES 1 | | | AND 2, 4/6 IN ZONE 3.CHECK ALL SHEETS | | | AND REVISE ALL AFFECTED DETAILS AND | | | NOTES TO BE COMPLIANT WITH THE MINIMUM | | | REQUIREMENTS OF FBC*2306.1. | | | | | | 6.) THE "ENERGY CALC REQUIREMENTS" FOR | | | THE BLOCK WALLS ON SHEET SP DO NOT MEET | | | THE MINIMUM REQUIREMENTS OF THE ENERGY | | | CALCS PREPARED BY EARTHSMART. | | | | | | 7.) IF SHUTTERS ARE TO BE A PART OF THIS | | | PERMIT, COMPLETE THE SHUTTER ANCHORING | | | SCHEDULE AS WELL AS A PLAN SHOWING WHICH | | | OPENINGS ARE TO BE SHUTTERED AS WELL AS | | | SHOWING THE MEANS OF ESCAPE FBC1005.4.5. | | | NOTE THAT OCCUPANTS MUST BE ABLE TO | | | ACCESS THE MEANS OF ESCAPE WITHOUT | | | PASSING THROUGH A GARAGE OR A LOCKABLE | | | DOOR NOT UNDER THEIR CONTROL. | | | | | | 8.) SEE PREVIOUS LIST, ITEM #16, FLORIDA | | | STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | | IN ADDITION TO TEST REPORTS, FAC9B72. | | | WWW.FLORIDABUILDING.ORG.PLEASE PRINT | | | THE STATE PRODUCT APPROVAL, IF | | | AVAILABLE, AND CLEARLY INDICATE ON THAT | | | APPROVAL WHICH PRODUCT YOU ARE USING. | | | | | | 9.)FOR THE FLAT ROOF, PLEASE CIRCLE | | | THE APPROVED ASSEMBLY YOU ARE GOING TO | | | INSTALL. | | | | | | ANY PRODUCT APPROVALS NOT SUBMITTED | | | PROPERLY PRIOR TO ISSUANCE WILL REQUIRE | | | SEPARATE PERMITS. | | | | | | 10.)SEE ATTACHED FS553.80(2)(B).A 4X | | | PLAN REVIEW FEE IS REQUIRED TO BE | | | CHARGED IF THE COMMENTS ARE NOT PROPERLY | | | ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-22 |
Time |
16:49 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-02-18 |
Time |
16:38 |
Sent To |
PC |
|
| Notes |
| 2005-02-22 00:00:00 | PERMIT #05011482 | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.) A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 3.) ENERGY CALCS REQUIRED, FBC13-101.2. | | | | | | 4.) PROVIDE A COPY OF A SURVEY FOR THIS | | | PROPERTY. | | | | | | 5.) THE ARCHITECT'S SEAL IS TO BE DATED, | | | FAC61G1-16.003. | | | | | | 6.) EMERGENCY EGRESS REQUIRED, FBC | | | 1005.4.SHOW WINDOW SIZE AND TYPE FOR | | | OFFICE/GUEST BEDROOM. | | | | | | 7.) THE ROOF SHEATHING NAILING NOTE | | | (SHEET SP) CONFLICTS WITH 2-A4 AND IS | | | NOT COMPLIANT FOR ZONE 4, FBC*TABLE | | | 2306.1. | | | | | | 8.) THE INFORMATION PROVIDED IN ENERGY | | | CALC REQUIREMENTS, SHEET SP, CONFLICTS | | | WITH THE DETAILS ON THE PLAN.ALSO NOTE | | | THAT IF A FORM 600C IS USED FOR ENERGY | | | CALCS, THE INSULATION SPECIFIED DOES NOT | | | MEET THE MINIMUM PRESCRIPTIVE | | | REQUIREMENTS. | | | | | | 9.) SAFETY GLASS REQUIRED IN M.BATH | | | (A1), FBC2405.1.PLEASE NOTE ON THE | | | PLAN.IMPACT GLASS IS COMPLIANT. | | | | | | 10.) THE SHUTTER PRODUCT APPROVALS | | | SUBMITTED ARE NOT NECESSARY AS ALL | | | PRODUCTS ARE IMPACT, AND IMPACT WAS | | | SPECIFIED ON THE PLAN.IF YOU WOULD | | | LIKE TO INSTALL THE SHUTTERS OVER THE | | | IMPACT RESISTANT PRODUCTS, PROVIDE A | | | SHUTTER ANCHORING SCHEDULE, SEE | | | ATTACHED. | | | | | | 11.) THE SOFFIT VENTS ARE TO COMPLY WITH | | | FBC2309.7. | | | | | | 12.) INDICATE THE DISTANCE FROM GRADE TO | | | THE BOTTOM OF THE FLOOR JOISTS, | | | FBC2304.3. | | | | | | 13.) SHOW CRAWL SPACE VENTILATION, | | | FBC1804.6.3.1. | | | | | | 14.) 1-A5, STATES "TOP OF FTG ELEVATION | | | IS A MINIMUM OF 8? BELOW ADJACENT | | | GRADE."DO YOU MEAN BOTTOM OF FOOTING? | | | THE BOTTOM IS REQUIRED TO BE MINIMUM OF | | | 12" BELOW GRADE, FBC1804.1.3.PLEASE | | | CLARIFY. | | | | | | 15.) FOOTING B, S1, SHOWS A 12" FOOTER | | | DEPTH ALTHOUGH THE NOTE (AND OTHER | | | DETAILS) INDICATE 18".BOTTOM OF | | | FOUNDATION TO BE A MINIMUM OF 12" BELOW | | | GRADE, FBC1804.1.3.THE TOP OF SLAB IS | | | TO BE 4" ABOVE GRADE, FBC*1804.1.7. | | | | | | 16.) FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED IN ADDITION TO TEST | | | REPORTS, FAC9B72. | | | WWW.FLORIDABUILDING.ORG.PLEASE PRINT | | | THE STATE PRODUCT APPROVAL, IF | | | AVAILABLE, AND CLEARLY INDICATE ON THAT | | | APPROVAL WHICH PRODUCT YOU ARE USING. | | | | | | 17.) SPECIFY A DESIGN PRESSURE FOR THE | | | ROOF. | | | | | | 18.) PRODUCT APPROVAL REQUIRED FOR THE | | | CUSTOM GARAGE DOOR.SEE | | | WWW.FLORIDABUILDING.ORG, FAC9B72. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-29 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-29 |
Time |
15:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-06 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-06 |
Time |
09:26 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-05 |
Time |
09:34 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-12-05 |
Time |
08:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-02 |
Time |
14:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-02 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-22 |
Time |
06:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-22 |
Time |
06:04 |
Sent To |
P |
|
| Notes |
| 2005-11-22 00:00:00 | | | | THERE ARE NO REVISIONS DESIGNATED ON THE | | | PLANS SUBMITTED, AND NO DATE ON THE | | | ARCHITECTS SEAL. THE TITLE BLOCK ON ALL | | | SHEETS HAVE THE SAME DATE. | | | | | | THERE IS NO ELECTRICAL REVIEW ON THIS | | | RESUB. PLEASE BE MORE SPECIFIC ON THE | | | ELECTRICAL RESUB, IF ONE IS NEEDED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-02 |
Time |
08:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-02 |
Time |
08:41 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-10 |
Time |
08:59 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-09 |
Time |
16:26 |
Sent To |
M |
|
| Notes |
| 2005-02-10 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | I SPOKE WITH THE OWNER/CONTRACTOR WHO | | | INDICATED HE WANTS TO INSTALL AN | | | UPGRADED SERVICE. PLEASE PROVIDE THE | | | FOLLOWING FOR REVIEW. | | | | | | 1} A RISER DIAGRAM FOR ALL ELECTRICAL | | | EQUIPMENT. | | | | | | 2} PROPSED LOCATIONN OF ALL EQUIPMENT ON | | | THE DRAWING. | | | | | | 3} PLEASE INCLUDE THE AIC RATINGS PER | | | 110.9. CONTACT FPL FOR FAULT CURRENT AT | | | THEIR TRANSFORMER SERVING THE | | | RESIDENCE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-23 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-23 |
Time |
15:49 |
Sent To |
E |
|
| Notes |
| 2007-08-23 15:50:18 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-27 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-27 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2007-06-27 14:53:16 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-23 |
Time |
10:22 |
Sent To |
M |
|
| Notes |
| 2007-01-23 10:22:49 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-05 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-05 |
Time |
12:41 |
Sent To |
M |
|
| Notes |
| 2007-01-05 12:42:11 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-26 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-26 |
Time |
11:32 |
Sent To |
M |
|
| Notes |
| 2006-12-26 11:32:34 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
15:38 |
Sent To |
M |
|
| Notes |
| 2006-12-17 15:39:16 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
|
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
19:19 |
Sent To |
E |
|
| Notes |
| 2006-11-29 19:19:47 | SENT TO BILL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-08 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-08 |
Time |
13:15 |
Sent To |
B |
|
| Notes |
| 2006-06-08 00:00:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-06 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-06 |
Time |
11:22 |
Sent To |
P |
|
| Notes |
| 2006-04-06 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-08 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-08 |
Time |
16:38 |
Sent To |
P |
|
| Notes |
| 2006-02-08 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
18:08 |
Sent To |
E |
|
| Notes |
| 2005-11-17 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-17 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-17 |
Time |
15:56 |
Sent To |
B |
|
| Notes |
| 2005-08-17 00:00:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-01 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-01 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
| 2005-08-01 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
12:34 |
Sent To |
Z |
|
| Notes |
| 2005-07-21 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
09:40 |
Sent To |
E |
|
| Notes |
| 2005-02-04 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
10:51 |
Sent To |
Z |
|
| Notes |
| 2005-01-31 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-23 |
Time |
15:29 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-01-23 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2007-01-23 15:32:04 | REVISION TO MECHANICAL PLANS AND ENERGY CAL'S. | | | *** PROVISO *** | | | 1) PROVIDE COMBUSTION AIR FOR GAS CLOTHES DRYER, PER | | | 2004 FBC?R M1701.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-01-05 |
Time |
13:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-01-05 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-01-05 13:51:07 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) MECHANICAL PLANS ARE SEALED BY AN ARCHITECT, ONLY BE | | | CAN MAKE CHANGES TO THE PLANS, AND WHITE OUT MAY NOT BE | | | USED ON PLANS. | | | | | | 2) PLANS DO NOT SHOW HOW THE RETURN AIR PLENUM IS GOING | | | TO RETURN AIR TO THE AIR HANDLER. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-27 |
Time |
08:37 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-27 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2006-12-27 08:49:30 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) PLEASE PROVIDE COMBUSTION AIR FOR GAS CLOTHES DRYER, | | | PER 2004 FBC/R M1701.1. | | | | | | 2) RETURN AIR GRILL IN MUD ENTRY WILL NOT WORK IF THE | | | DOORS ARE CLOSED, PLEASE MOVE TO DINNING ROOM, PER 2004 | | | FBC/R M1602.4. | | | | | | 3) 9" RETURN AIR DUCT TO MASTER SUITE IS TO SMALL FOR | | | 535 CFM'S OF SUPPLY AIR, AND NEEDS TO BE 12". | | | BALANCED RETURN AIR. | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-18 |
Time |
16:16 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-18 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2006-12-18 16:22:03 | *** DENIED *** | | | 1) REVISIONS TO THE MECHANICAL PLANS CAN ONLY BE DONE | | | BY THE ARCHITECT OF RECORDS (EDWARD H. SHEAHAN) AND | | | PLANS AND ENERGY CALCULATION WILL REQUIRE HIS SEAL AND | | | SIGNATURE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2005-11-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-23 |
Time |
10:50 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-11-23 |
Time |
10:50 |
Sent To |
E |
|
| Notes |
| 2005-11-23 00:00:00 | MECH. PLANS HAD PASSED ON 8-3-05. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-08-03 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-08-03 |
Time |
18:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-15 |
Time |
11:42 |
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-02-15 |
Time |
11:42 |
Sent To |
P |
|
| Notes |
| 2005-02-15 00:00:00 | MECH. A/C REVIEW. | | | | | | 1. PROVIDE FL. ENERGY CALCULATIONS FOR | | | RENOVATED BULDING. FBC/CHAPTER 13 | | | /101.5.1 . | | | 2.PROVIDE FOR COMBUSTION AIR FOR GAS | | | DRYER IN LND/ROOM, TO CONFORM WITH 2001 | | | FBC/M SECTION 702 THROUGH 705 FOR SIZING | | | AND INSTALLATION.NOTE;SUBMIT GAS | | | DRYER INFORMATION FOR GAS BTU/PER HR | | | RATING. | | | 3.R/A AIR DUCTS ARE NOT SIZED. | | | 4. MAIN SUPPLY AIR DUCTS NOT SIZED. | | | 5. PROVIDE FOR R/A OUT OF BEDROOM, | | | OFFICE/GBRM. 2001 FBC/M 601.4 BALANCED | | | RETURN AIR. | | | | | | PAT RAFTER 561/805/6728 . | | | PLEASE CALL IF THEAR ENY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-07 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-07 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-10 |
Time |
12:04 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2006-02-10 |
Time |
12:04 |
Sent To |
B |
|
| Notes |
| 2006-02-10 00:00:00 | DENIED; | | | PLUMBING PLANS WERE NOT CORRECTED FROM | | | LAST REVIEW 11/22/05. | | | 1.TUB SHOWER AND SINK IN GARAGE ARE NOT | | | VENTED TO FBC-2001 CHAPTER 9. | | | 2.CLEANOUTS ARE REQUIRED WHEN DRAINAGE | | | SYSTEM EXITS THE HOUSE. SEE FBC-2001 | | | SEC. 708.3.5. CLEANOUTS REQUIRED AT | | | KITCHEN, TUB, SHOWER AND BATHROOM DRAIN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-22 |
Time |
15:04 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-11-22 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2005-11-22 00:00:00 | DENIED; | | | PLUMBING PLAN WAS CHANGED FROM LAST | | | REVIEW 8/3/05. TUB AND SHOWER ARE NOT | | | VENTED. CLEANOUTS REQUIRED AT JUNCTION | | | OF BUILDING DRAIN AND BUILING SEWER. | | | SEC708.3.5. | | | SINK IN GARAGE IS NOT VENTED. | | | PLUMBING REVIEW BY | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-03 |
Time |
09:16 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-08-03 |
Time |
09:16 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-17 |
Time |
15:44 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-02-17 |
Time |
15:44 |
Sent To |
B |
|
| Notes |
| 2005-02-17 00:00:00 | DENIED; | | | 1.PAGE P-1 NOTE 20 WATER TEST ON | | | DRAINAGE PIPE IS 5' NOT 3'. | | | 2.TWO WAY CLEANOUTS ARE REQUIRED WHEN | | | DRAINAGE PIPES EXIT HOUSE. | | | 3.TUB AND SHOWER ARE NOT VENTED, | | | 4.SINK IN GARAGE REQUIRES A VENT AND | | | CANNOT BE PART OF THE WET VENT SYSTEM OF | | | A BATHROOM GROUP. SEC 909.1 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-29 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-28 |
Time |
17:55 |
Sent To |
I |
|
| Notes |
| 2005-07-29 00:00:00 | NOTE: MUST PULL SEPERATE PERMIT FOR | | | WALL/GATE/FENCE WITH UTILITIES EASEMENT | | | APPROVAL. | | | | | | NOTE: MUST PULL SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE. | | | | | | APPROVAL DOES NOT INCLUDE | | | FENCE/WALL/GATE/POOL/SPA/DECK/SCREEN | | | ENCLOSURE. | | 2005-07-28 00:00:00 | NEED TO HAVE SECOND OPINION ON PLANS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-03 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-03 |
Time |
10:50 |
Sent To |
I |
|
| Notes |
| 2005-02-03 00:00:00 | DENIED | | | 1. NEED TO PROVIDE TWO COPY OF SURVEY | | | (SIGNED & SEAL). | | | 2.DRIVEWAY DIMENSION SHOULD BE PROVIDED | | | (WIDTH & LENGTH (MUST MEET 1000SQ FT OR | | | 75% OF LANDSCAPE WITHIN THE FIRST 25FT | | | FRONT SETBACK). | | | 3. MUST PULL SEPERATE PERMIT FOR | | | POOL/DECK/SCREEN ENCLOSURE. | | | 4. MUST PULL SEPERATE PERMIT FOR | | | PRIVACY | | | WALL WITH CITY OF WEST PALM BEACH | | | UTILITY DEPT APPROVAL.WALL MUST BE | | | DRAWN TO SCALE. | | | 5. TRELLIS MUST BE DRAWN TO SCALE, WITH | | | THE HEIGHT. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SVCS | | | 805-6720 |
|
|