Plan Review Details - Permit 05010811
Plan Review Stops For Permit 05010811
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-08-10 Cont ID  
Sent By rmcdouga Date 2005-08-10 Time 17:58 Rev Time 0.00
Received By rmcdouga Date 2005-08-10 Time 15:56 Sent To  
Notes
2005-08-11 00:00:00PROVISO
  
 A SEPARATE PERMIT IS REQUIRED FOR STORM
 PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-07 Cont ID  
Sent By rmcdouga Date 2005-02-07 Time 07:57 Rev Time 0.00
Received By rmcdouga Date 2005-02-07 Time 07:57 Sent To  
Notes
2005-02-07 00:00:00DENIED
  
 1) SUBMIT A LETTER FROM A LICENSED
 THRESHOLD INSPECTOR STATING THAT AN
 INSPECTION WILL BE MADE AT THE
 MANUFACTURED SITE OF THE JOB SPECIFIC
 COMPONENTS TO VERIFY CONSTRUCTION
 COMPLIANCE OF THE COMPONENTS WITH THE
 ENGINEERED DESIGN. A CERTIFICATE OF
 COMPLIANCE AFFIDAVIT WILL BE REQUIRED
 FROM THE THRESHOLD INSPECTOR WILL ALSO
 BE REQUIRED DURING CONSTRUCTION. SEE
 ATTACHMENT.
  
 2) SUBMIT FLORIDA PRODUCT APPROVALS FOR
 THE TRUSS CONNECTORS.
  
 3) THE TRUSS ANCHOR SCHEDULES ON SHEETS
 RF-1 AND SD2 CONTAIN CONFLICTING
 INFORMATION. PLEASE CORRECT.
  
 4) SUBMIT STATE PRODUCT APPROVAL FOR THE
 LARGE (48 SQFT) FIXED GLASS WINDOW IN
 THE DINING ROOM.
  
 5) THE STATE PRODUCT APPROVALS FOR THE
 CLOPAY GARAGE DOORS DO NOT HAVE THE
 CORRECT EVALUATION REPORTS AND DRAWINGS
 ATTACHED. DOWNLOAD THE PROPER REPORTS
 FROM THE WWW.FLORIDABUILDING.ORG
 WEBSITE.THE EVALUATION ENTITY IS GARY
 PFLUEHLER, P.E.
  
 6) SUBMIT STORM PANEL PRODUCT APPROVAL,
 KEY PLANS AND INSTALLATION SCHEDULES OR
 APPLY UNDER A SEPARATE PERMIT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-24 Cont ID  
Sent By dpalmer Date 2005-01-24 Time 19:30 Rev Time 0.30
Received By dpalmer Date 2005-01-24 Time 19:30 Sent To M
Notes
2005-01-24 00:00:00PLANS STAMPED.
  
 ALL REVISIONS/OPTIONS ARE RESUBMITTED
 AND REVIEWED BEFORE ROUGH ELECTRICAL
 INSPECTION IS CALLED IN.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 11:37 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 11:37 Sent To M
Notes
2005-07-28 00:00:00TO "PKRAUSS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-24 Cont ID  
Sent By mjacobs Date 2005-01-24 Time 17:04 Rev Time 0.00
Received By mjacobs Date 2005-01-24 Time 17:04 Sent To E
Notes
2005-01-24 00:00:00TO "E SFR" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-20 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 08:35 Rev Time 0.00
Received By mjacobs Date 2005-01-20 Time 08:35 Sent To Z
Notes
2005-01-20 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-08-03 Cont ID  
Sent By prafter Date 2005-08-02 Time 09:18 Rev Time 1.00
Received By prafter Date 2005-08-03 Time 11:35 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-01-26 Cont ID  
Sent By prafter Date 2005-01-26 Time 11:16 Rev Time 1.00
Received By prafter Date 2005-01-26 Time 11:16 Sent To P
Notes
2005-01-26 00:00:00A/C #1 REFLECTS 10.70 SEER RATING,
 WHERA AS THE FL. ENERGY PERFORMANCY
 METHOD (A) REPORT SHOW 11.0 SEER MIN.
 RATING FOR A/C #1.
 PAT RAFTER 561/805/6725 OR 805/6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-08-02 Cont ID  
Sent By prafter Date 2005-08-03 Time 11:36 Rev Time 0.50
Received By jleech Date 2005-08-02 Time 10:48 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-27 Cont ID  
Sent By kstevens Date 2005-01-27 Time 11:28 Rev Time 0.50
Received By kstevens Date 2005-01-27 Time 11:28 Sent To B1
Notes
2005-01-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT 1.1 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS NOR DOES IT
 REFLECT THE FLOOR PLAN.
 A) RISER SHALL SHOW FIXTURES THAT ARE
 INSTALLED AND NOT OPTIONAL FIXTURES.
 SECTION 104.2.1.
 B) POWDER ROOM SHOWS THE LAV ON THE
 RIGHT SIDE OF THE ROOM AND THE W/C ON
 THE LEFT SIDE ON THE RISER, BUT BOTH
 FIXTURES ARE ON THE LEFT SIDE OF THE
 ROOM ON THE FLOOR PLAN. PLEASE CORRELATE
 THE RISER AND FLOOR PLAN. SECTION
 104.2.1.
 C) LAUNDRY TRAY SHALL NOT DRAIN THROUGH
 THE HORIZONTAL WET VENT FOR THE BATHROOM
 FIXTURES. SECTION 909.1
 D) A CLEANOUT IS REQUIRED 4' ABOVE THE
 FLOOR AT THE WASH MACHINE. SECTION
 708.10.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-24 Cont ID  
Sent By mmclean Date 2005-01-24 Time 16:49 Rev Time 0.00
Received By mmclean Date 2005-01-24 Time 16:49 Sent To I
Notes
***NONE***