| Plan Review Stops For Permit 05010754 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-04-07 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-04-05 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2005-04-07 00:00:00 | SEE PROVISOS ON PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-04 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | PLANS DENIED BY CITY ATT. CLAUDIA | | | MCKENNA, SEE LETTTER ATTACED TO 2/28/05 | | | SUBMITTAL | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-07 |
Time |
13:28 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-02-07 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2005-02-07 00:00:00 | DENIED | | | | | | 1.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 2.1015.2 HEIGHT. GUARDRAILS SHALL | | | FORM A VERTICAL PROTECTIVE BARRIER NOT | | | LESS THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | | REJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE. | | | | | | 3.ROOFING DETAILS ON PLANS SPEC A | | | METAL ROOF. PRODUCT APPROVALS ARE FOR | | | COMP. SHINGLES.PLEASE VERIFY. | | | | | | 4.SHOW SIZE AND LOCATION OF ATTIC | | | ACCESS COMPLYING WITH FBC 2309.6 | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
DEMO |
DEMO/BOARD/SEC/EMERGENCY |
| Rev No |
1 |
Status |
N |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-04 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-03-03 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-04 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-04 |
Time |
17:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-28 |
Time |
16:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-28 |
Time |
15:16 |
Sent To |
P |
|
| Notes |
| 2005-01-28 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE A CALCULATION INCLUDI- | | | NG ALL ADDED LOADS IMPOSED,ALL EXISTING | | | LOADS. THE A/C,WATER HEATER AND POOL | | | EQUIPMENT IN POOL HOUSE ARE NOT SHOWN ON | | | THE CALC'S. | | | | | | 2} THERE IS NO LAUNDRY CIRCUIT IN THE | | | CALCULATION PER 220.16(B). | | | | | | 3} THERE IS NO DRYER IN THE CALCULATION | | | PER 220.18. | | | | | | 4} THE TWO RISER DIAGRAMS DO NOT | | | CORRELATE. IS THE 150 AMP PANEL FED FROM | | | THE METER OR THE200 AMP HOUSE PANEL? | | | | | | 5} SHOW LOCATION OF ALL SERVICE | | | EQUIPMENT ON THE POOL HOUSE ON THE | | | PLAN. | | | | | | 6} SHOW 150 AMP PANEL SCHEDULE AND | | | GROUNDING PER 250.32 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-01 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-01 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-20 |
Time |
08:14 |
Sent To |
E |
|
| Notes |
| 2005-01-20 00:00:00 | TO "E' BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-18 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-18 |
Time |
13:49 |
Sent To |
Z |
|
| Notes |
| 2005-01-18 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-04 |
Time |
09:02 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-02-04 |
Time |
09:02 |
Sent To |
P |
|
| Notes |
| 2005-02-04 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH THE PERMIT APPPLICATION. | | | ENERGY AND MANUAL J CALCS SUBMITTED WITH | | | THE BUILDING PERMIT APPLICATION.PLEASE | | | PROVIDE EQUIPMENT SCHEDULE AND PLANS | | | WITH MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-02-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-02-05 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-02-05 |
Time |
11:05 |
Sent To |
B |
|
| Notes |
| 2005-02-05 00:00:00 | BACK FLOW PREVENTER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-05 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-05 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2005-04-05 00:00:00 | CONDITIONAL APPROVALS SHOULD BE ISSUED | | | WITH THE UNDERSTANDING THAT THE APPROVAL | | | WILL BE REVOKED & ANY IMPROVEMENTS | | | REVERSED IF, FOR ANY REASON, THE | | | COMMISSION DOES NOT ADOPT THE CORRECTIVE | | | PLAN. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-28 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-28 |
Time |
11:52 |
Sent To |
E |
|
| Notes |
| 2005-02-28 00:00:00 | SURVEY PROVIDED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-19 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-19 |
Time |
16:54 |
Sent To |
I |
|
| Notes |
| 2005-01-19 00:00:00 | DENIED, MUST PROVIDE TWO COPY OF SURVEY | | | SHOWING THE LOCATION OF THE ADDITION | | | (POOL HOUSE) WITH SETBACKS AND DIMENSION | | | OF LOT.CALLED BOBBY C. |
|
|