Plan Review Details - Permit 05010754
Plan Review Stops For Permit 05010754
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-04-07 Cont ID  
Sent By lmartine Date 2005-04-07 Time 16:04 Rev Time 0.00
Received By lmartine Date 2005-04-05 Time 16:06 Sent To  
Notes
2005-04-07 00:00:00SEE PROVISOS ON PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-03-04 Cont ID  
Sent By lmartine Date 2005-03-04 Time 15:43 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2005-03-04 00:00:00PLANS DENIED BY CITY ATT. CLAUDIA
 MCKENNA, SEE LETTTER ATTACED TO 2/28/05
 SUBMITTAL
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-07 Cont ID  
Sent By alange Date 2005-02-07 Time 13:28 Rev Time 1.00
Received By alange Date 2005-02-07 Time 13:28 Sent To  
Notes
2005-02-07 00:00:00DENIED
  
 1.PLEASE SIGN OWNER/AGENT ON ENERGY
 CALCS.
  
 2.1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
  
 3.ROOFING DETAILS ON PLANS SPEC A
 METAL ROOF. PRODUCT APPROVALS ARE FOR
 COMP. SHINGLES.PLEASE VERIFY.
  
 4.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS COMPLYING WITH FBC 2309.6
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop DEMO DEMO/BOARD/SEC/EMERGENCY
Rev No 1 Status N Date 2005-03-04 Cont ID  
Sent By lmartine Date 2005-03-04 Time 15:45 Rev Time 0.00
Received By lmartine Date 2005-03-03 Time 09:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-04-04 Cont ID  
Sent By btrobaug Date 2005-04-04 Time 17:20 Rev Time 0.50
Received By btrobaug Date 2005-04-04 Time 17:20 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-28 Cont ID  
Sent By btrobaug Date 2005-01-28 Time 16:21 Rev Time 0.50
Received By btrobaug Date 2005-01-28 Time 15:16 Sent To P
Notes
2005-01-28 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE A CALCULATION INCLUDI-
 NG ALL ADDED LOADS IMPOSED,ALL EXISTING
 LOADS. THE A/C,WATER HEATER AND POOL
 EQUIPMENT IN POOL HOUSE ARE NOT SHOWN ON
 THE CALC'S.
  
 2} THERE IS NO LAUNDRY CIRCUIT IN THE
 CALCULATION PER 220.16(B).
  
 3} THERE IS NO DRYER IN THE CALCULATION
 PER 220.18.
  
 4} THE TWO RISER DIAGRAMS DO NOT
 CORRELATE. IS THE 150 AMP PANEL FED FROM
 THE METER OR THE200 AMP HOUSE PANEL?
  
 5} SHOW LOCATION OF ALL SERVICE
 EQUIPMENT ON THE POOL HOUSE ON THE
 PLAN.
  
 6} SHOW 150 AMP PANEL SCHEDULE AND
 GROUNDING PER 250.32
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-01 Cont ID  
Sent By pkrauss Date 2005-03-01 Time 15:47 Rev Time 0.00
Received By pkrauss Date 2005-03-01 Time 15:47 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-20 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 08:14 Rev Time 0.00
Received By mjacobs Date 2005-01-20 Time 08:14 Sent To E
Notes
2005-01-20 00:00:00TO "E' BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-18 Cont ID  
Sent By mjacobs Date 2005-01-18 Time 13:49 Rev Time 0.00
Received By mjacobs Date 2005-01-18 Time 13:49 Sent To Z
Notes
2005-01-18 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-02-04 Cont ID  
Sent By pkrauss Date 2005-02-04 Time 09:02 Rev Time 0.20
Received By pkrauss Date 2005-02-04 Time 09:02 Sent To P
Notes
2005-02-04 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED WITH THE PERMIT APPPLICATION.
 ENERGY AND MANUAL J CALCS SUBMITTED WITH
 THE BUILDING PERMIT APPLICATION.PLEASE
 PROVIDE EQUIPMENT SCHEDULE AND PLANS
 WITH MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-02-05 Cont ID  
Sent By pschmitz Date 2005-02-05 Time 11:05 Rev Time 0.00
Received By pschmitz Date 2005-02-05 Time 11:05 Sent To B
Notes
2005-02-05 00:00:00BACK FLOW PREVENTER.

Review Stop Z ZONING
Rev No 3 Status P Date 2005-04-05 Cont ID  
Sent By mmclean Date 2005-04-05 Time 08:22 Rev Time 0.00
Received By mmclean Date 2005-04-05 Time 08:22 Sent To  
Notes
2005-04-05 00:00:00CONDITIONAL APPROVALS SHOULD BE ISSUED
 WITH THE UNDERSTANDING THAT THE APPROVAL
 WILL BE REVOKED & ANY IMPROVEMENTS
 REVERSED IF, FOR ANY REASON, THE
 COMMISSION DOES NOT ADOPT THE CORRECTIVE
 PLAN.

Review Stop Z ZONING
Rev No 2 Status P Date 2005-01-28 Cont ID  
Sent By mmclean Date 2005-01-28 Time 11:52 Rev Time 0.00
Received By mmclean Date 2005-01-28 Time 11:52 Sent To E
Notes
2005-02-28 00:00:00SURVEY PROVIDED.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By mmclean Date 2005-01-19 Time 16:54 Rev Time 0.00
Received By mmclean Date 2005-01-19 Time 16:54 Sent To I
Notes
2005-01-19 00:00:00DENIED, MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE LOCATION OF THE ADDITION
 (POOL HOUSE) WITH SETBACKS AND DIMENSION
 OF LOT.CALLED BOBBY C.