| Plan Review Stops For Permit 05010646 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-01 |
Time |
15:40 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-04-01 |
Time |
15:17 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-03 |
Time |
07:11 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2005-02-03 |
Time |
07:11 |
Sent To |
PC |
|
| Notes |
| 2005-02-03 00:00:00 | PAY BALANCEBUILDING PLAN REVIEW | | | PERMIT: 05100646 | | | ADD: 1597 HAWKS LANDING | | | CONT: DREAMSTAR | | | TEL: (561)694-7750 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK OF | | | COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) PAY THE BALANCE DUE ON PERMIT OF | | | $2,325.75. | | | | | | 3) SHEET A-3 TRUSS ANCHOR "D" VALUE IS | | | HIGH, SEE 2005 USP CATALOG, 2 PLY IS | | | 4255 & 3 PLY IS 6110. | | | | | | 4) SHEET A-3 ROOF FRAMING PLAN, MISSING | | | GIRDERS AT THE BACK COVERED PORCH | | | TRUSSES ARE CANTILEVERED 14'-10". | | | | | | 5A) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THERE IS NO FRAMING DETAILS FOR THE | | | CHIMNEY? | | | 5B) WITH A PREMANUFACTURED CHIMNEY | | | APPROVAL FROM THE MANUFACTURER WILL BE | | | REQUIRED FOR THE CHIMNEY CAP ENCLOSURE, | | | SINCE IT MAY NOT BE ABLE TO PULL A | | | DRAFT. | | | | | | 6) 2804.4.1 FACTORY-BUILT CHIMNEYS | | | FACTORY BUILT CHIMNEYS SHALL BE LISTED | | | AND SHALL BE INSTALLED IN ACCORDANCE | | | WITH THE CONDITIONS OF THE LISTING, AND | | | MANUFACTURER'S INSTRUCTION. | | | | | | 7) CHIMNEYS FOR THE USE WITH FACTORY- | | | BUILT FIREPLACES SHALL MEET THE | | | REQUIREMENTS OF UL 127. | | | | | | 8) 2806.1.2 FACTORY BUILT FIREPLACES | | | SHALL BE TESTED IN ACCORDANCE WITH AND | | | MEET THE REQUIREMENTS OF UL 127. | | | | | | 9) 2804.4.4. FACTORY-BUILT CHIMNEYS FOR | | | USE WITH CLOSED COMBUSTION WOOD BURNING | | | APPLIANCES SHALL COMPLY WITH | | | THE TYPE HT REQUIREMENT UL 103. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-23 |
Time |
08:12 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-02-23 |
Time |
07:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-21 |
Time |
13:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-21 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-20 |
Time |
16:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-20 |
Time |
16:04 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-20 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-20 |
Time |
16:29 |
Sent To |
E |
|
| Notes |
| 2005-12-20 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-09 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-09 |
Time |
14:53 |
Sent To |
G |
|
| Notes |
| 2005-09-09 00:00:00 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-16 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-16 |
Time |
11:41 |
Sent To |
P |
|
| Notes |
| 2005-03-16 00:00:00 | TO "KSTEVENS" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-10 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-10 |
Time |
11:01 |
Sent To |
Z |
|
| Notes |
| 2005-03-10 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-20 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2005-01-20 00:00:00 | TO "SFR" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-14 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-14 |
Time |
10:37 |
Sent To |
Z |
|
| Notes |
| 2005-01-14 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-24 |
Time |
08:07 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-24 |
Time |
08:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2005-03-21 |
Time |
12:55 |
Rev Time |
0.50 |
| Received By |
gsalfeld |
Date |
2005-03-21 |
Time |
12:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-27 |
Time |
10:56 |
Rev Time |
0.42 |
| Received By |
kstevens |
Date |
2005-01-27 |
Time |
10:56 |
Sent To |
B1 |
|
| Notes |
| 2005-01-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT A4 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) EVERY DRY VENT CONNECTING TO A | | | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE | | | CENTERLINE OF THE HORIZONTAL DRAIN PIPE. | | | SECTION 905.3. (SEE BIDET IN M/B AND | | | SHOWER IN BATH #3). | | | B) WASH MACHINE SHALL HAVE A STANDPIPE | | | PER SECTIONS 1002.1 & 802.4 | | | C) CLEANOUT FOR WASH MACHINE SHALL BE | | | 4' ABOVE THE FLOOR. SECTION 708.10 | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-15 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-15 |
Time |
16:43 |
Sent To |
I |
|
| Notes |
| 2005-03-15 00:00:00 | DENIED, | | | 1. SITE PLAN & SURVEY SHOWS DIFFERENT | | | ADDRESS. BOUNDARY SURVEY & APPLICATION | | | SHOWS 7597 HAWKS LANDING DRIVE LOT 13 | | | AND SITE PLAN SHOWS CRANES POINT WEST, | | | LOT 13.NEED TO HAVE SURVEY AND SITE | | | PLAN TO MATCH.CALLED LISA LEFT MSG ON | | | VOICE MAIL. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-19 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-19 |
Time |
14:04 |
Sent To |
I |
|
| Notes |
| 2005-01-19 00:00:00 | DENIED, CHIMNEY IS OVER THE HEIGHT | | | REQUIREMENT 33FT.NEED TO REDUCE | | | CHIMNEY HEIGHT. |
|
|