Plan Review Details - Permit 05010646
Plan Review Stops For Permit 05010646
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-04-01 Cont ID  
Sent By jwitmer Date 2005-04-01 Time 15:40 Rev Time 2.22
Received By jwitmer Date 2005-04-01 Time 15:17 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-03 Cont ID  
Sent By jwitmer Date 2005-02-03 Time 07:11 Rev Time 4.44
Received By jwitmer Date 2005-02-03 Time 07:11 Sent To PC
Notes
2005-02-03 00:00:00PAY BALANCEBUILDING PLAN REVIEW
 PERMIT: 05100646
 ADD: 1597 HAWKS LANDING
 CONT: DREAMSTAR
 TEL: (561)694-7750
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
  
 1)PROVIDE NOC RECORDED WITH THE CLERK OF
 COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2) PAY THE BALANCE DUE ON PERMIT OF
 $2,325.75.
  
 3) SHEET A-3 TRUSS ANCHOR "D" VALUE IS
 HIGH, SEE 2005 USP CATALOG, 2 PLY IS
 4255 & 3 PLY IS 6110.
  
 4) SHEET A-3 ROOF FRAMING PLAN, MISSING
 GIRDERS AT THE BACK COVERED PORCH
 TRUSSES ARE CANTILEVERED 14'-10".
  
 5A) FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 THERE IS NO FRAMING DETAILS FOR THE
 CHIMNEY?
 5B) WITH A PREMANUFACTURED CHIMNEY
 APPROVAL FROM THE MANUFACTURER WILL BE
 REQUIRED FOR THE CHIMNEY CAP ENCLOSURE,
 SINCE IT MAY NOT BE ABLE TO PULL A
 DRAFT.
  
 6) 2804.4.1 FACTORY-BUILT CHIMNEYS
 FACTORY BUILT CHIMNEYS SHALL BE LISTED
 AND SHALL BE INSTALLED IN ACCORDANCE
 WITH THE CONDITIONS OF THE LISTING, AND
 MANUFACTURER'S INSTRUCTION.
  
 7) CHIMNEYS FOR THE USE WITH FACTORY-
 BUILT FIREPLACES SHALL MEET THE
 REQUIREMENTS OF UL 127.
  
 8) 2806.1.2 FACTORY BUILT FIREPLACES
 SHALL BE TESTED IN ACCORDANCE WITH AND
 MEET THE REQUIREMENTS OF UL 127.
  
 9) 2804.4.4. FACTORY-BUILT CHIMNEYS FOR
 USE WITH CLOSED COMBUSTION WOOD BURNING
 APPLIANCES SHALL COMPLY WITH
 THE TYPE HT REQUIREMENT UL 103.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-02-23 Cont ID  
Sent By btrobaug Date 2006-02-23 Time 08:12 Rev Time 0.50
Received By btrobaug Date 2006-02-23 Time 07:52 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-12-21 Cont ID  
Sent By btrobaug Date 2005-12-21 Time 13:47 Rev Time 0.50
Received By btrobaug Date 2005-12-21 Time 12:39 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-20 Cont ID  
Sent By btrobaug Date 2005-01-20 Time 16:50 Rev Time 0.50
Received By btrobaug Date 2005-01-20 Time 16:04 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 16:29 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 16:29 Sent To E
Notes
2005-12-20 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-09 Cont ID  
Sent By adarroug Date 2005-09-09 Time 14:53 Rev Time 0.00
Received By adarroug Date 2005-09-09 Time 14:53 Sent To G
Notes
2005-09-09 00:00:00TO "G" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-16 Cont ID  
Sent By adarroug Date 2005-03-16 Time 11:41 Rev Time 0.00
Received By adarroug Date 2005-03-16 Time 11:41 Sent To P
Notes
2005-03-16 00:00:00TO "KSTEVENS" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-10 Cont ID  
Sent By adarroug Date 2005-03-10 Time 11:01 Rev Time 0.00
Received By adarroug Date 2005-03-10 Time 11:01 Sent To Z
Notes
2005-03-10 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-20 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 08:16 Rev Time 0.00
Received By mjacobs Date 2005-01-20 Time 08:16 Sent To E
Notes
2005-01-20 00:00:00TO "SFR" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-14 Cont ID  
Sent By mjacobs Date 2005-01-14 Time 10:37 Rev Time 0.00
Received By mjacobs Date 2005-01-14 Time 10:37 Sent To Z
Notes
2005-01-14 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-24 Cont ID  
Sent By prafter Date 2005-01-24 Time 08:07 Rev Time 0.45
Received By prafter Date 2005-01-24 Time 08:07 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-03-21 Cont ID  
Sent By gsalfeld Date 2005-03-21 Time 12:55 Rev Time 0.50
Received By gsalfeld Date 2005-03-21 Time 12:55 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-27 Cont ID  
Sent By kstevens Date 2005-01-27 Time 10:56 Rev Time 0.42
Received By kstevens Date 2005-01-27 Time 10:56 Sent To B1
Notes
2005-01-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT A4 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) EVERY DRY VENT CONNECTING TO A
 HORIZONTAL DRAIN SHALL CONNECT ABOVE THE
 CENTERLINE OF THE HORIZONTAL DRAIN PIPE.
 SECTION 905.3. (SEE BIDET IN M/B AND
 SHOWER IN BATH #3).
 B) WASH MACHINE SHALL HAVE A STANDPIPE
 PER SECTIONS 1002.1 & 802.4
 C) CLEANOUT FOR WASH MACHINE SHALL BE
 4' ABOVE THE FLOOR. SECTION 708.10
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2005-03-15 Cont ID  
Sent By mmclean Date 2005-03-15 Time 16:43 Rev Time 0.00
Received By mmclean Date 2005-03-15 Time 16:43 Sent To I
Notes
2005-03-15 00:00:00DENIED,
 1. SITE PLAN & SURVEY SHOWS DIFFERENT
 ADDRESS. BOUNDARY SURVEY & APPLICATION
 SHOWS 7597 HAWKS LANDING DRIVE LOT 13
 AND SITE PLAN SHOWS CRANES POINT WEST,
 LOT 13.NEED TO HAVE SURVEY AND SITE
 PLAN TO MATCH.CALLED LISA LEFT MSG ON
 VOICE MAIL.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By mmclean Date 2005-01-19 Time 14:04 Rev Time 0.00
Received By mmclean Date 2005-01-19 Time 14:04 Sent To I
Notes
2005-01-19 00:00:00DENIED, CHIMNEY IS OVER THE HEIGHT
 REQUIREMENT 33FT.NEED TO REDUCE
 CHIMNEY HEIGHT.