Plan Review Details - Permit 05010631
| Plan Review Stops For Permit 05010631 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-25 |
Time |
16:29 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2005-02-25 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-24 |
Time |
13:50 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-01-24 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010631 | | | ADD: 321 S DIXIE HWY | | | CONT: THE CORRADIND GROUP | | | TEL: (305)216-7488 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 3)DOOR# 113 TO MEET THE REQUIREMENTS | | | OF: | | | 1012.1.4. DURING ITS SWING, ANY DOOR | | | IN A MEANS OF EGRESS SHALL LEAVE | | | UNOBSTRUCTED AT LEAST 1/2 OF THE REQUIRE | | | REQUIRED WIDTH OF AN AISLE, CORRIDOR, | | | PASSAGEWAY, OR LANDING, NOR PROJECT MORE | | | THAN 7" INTO THE REQUIRED WIDTH. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-21 |
Time |
14:43 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-01-21 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-03-11 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-03-11 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-02-08 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-02-08 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2005-02-08 00:00:00 | 1. DOOR # 113 SWINGS TO FAR INTO | | | THE CORRIDOR WHICH SERVES AS AN | | | EXIT ACCESS TO AN EXISTING EXIT. | | | PLEASE REVISE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | TO "COMM" BD#47 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-13 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | TO "COMM BD#42 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-03-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-21 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-26 |
Time |
10:20 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-01-26 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2005-01-26 00:00:00 | DENIED: | | | 1.PLAN SHEET M-1 INDICATES RETURN AIR | | | GRILLES FROM THE FILING ROOM AND ALSO BY | | | THE MENS ROOM.PLAN DOES NOT INDICATE A | | | DUCTED RETURN BACK TO THE AHU.WILL | | | THESE AREAS BE A RETURN AIR PLENUM? | | | PLEASE NOTE AIR FROM THE RESTROOM IS NOT | | | TO BE RECIRCULATED. | | | | | | 2.NO COMBUSTIBLES ALLOWED ABOVE THE | | | CEILING IN THE RETURN AIR PLENUM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-07 |
Time |
12:35 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-02-07 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |