| Plan Review Stops For Permit 05010583 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-01-19 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
jhiggins |
Date |
2005-01-19 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | BLDG EXTENSION 19 CREATED FOR UNIT #801 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-02-18 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-01-24 |
Time |
08:14 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-09 |
Time |
12:01 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-02-09 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2005-02-09 00:00:00 | REVISED E-2. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-19 |
Time |
15:53 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-01-19 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-02-18 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-02-18 00:00:00 | | | | APPROVED BY NATE, PENDING SUBMITTAL OF | | | REVISED CLASS B MINIMUM REQUIREMENT FOR | | | THE EXIT ACCESS NOTE. SIGNED AND SEALED | | | | | | | | | | | | | | | L.MARTINEZ FOR | | | N.MCCRAY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-18 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-18 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION SHALL COMPLY WITH NFPA | | | 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3) INTERIOR WALL AND CEILING FINISH | | | MATERIALS COMPLYING WITH SECTION 10.2 | | | SHALL BE CLASS A OR CLASS B IN EXITS AND | | | IN EXIT ACCESS CORRIDORS. NOT CLASS C | | | WHICH IS INDICATED ON THE PLAN FRONT | | | COVER SHEET. | | | | | | 4) SEPARATE PLANS AND PERMITS ARE | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS REMODEL. | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-02-03 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-02-03 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2005-02-03 00:00:00 | TO "COMM BD#6" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-24 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-01-13 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | TO "COMM BD#30" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-11 |
Time |
14:07 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-02-11 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-19 |
Time |
11:55 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-01-19 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | DENIED: | | | PLAN SHEET M-2 HEAT PUMP DETAIL; SNOTE | | | INDICATES "DUCT SMOKE DETECTOR UNITS | | | 2000 CFM AND OVER".PER 2001 FBC(M) | | | 606.2.2, WHERE MULTIPLE AHU SYSTEMS | | | SHARE A COMMON PLENUM WITH A DESIGN | | | CAPACITY GREATER THAN 2,000 CFM, THE | | | RETURN & SUPPLY AIR SHALL BE PROVIDED | | | WITH DUCT SMOKE DETECTORS.PLEASE | | | REVISE PLANS ACCORDINGLY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-20 |
Time |
09:19 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-20 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | NO PLUMBING ADDED.ALL PLUMBING TO BE | | | LEFT AS IS. |
|
|