Plan Review Details - Permit 05010448
| Plan Review Stops For Permit 05010448 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-02 |
Time |
14:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-02 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-21 |
Time |
12:55 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-01-18 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | THE FOLLOWING CORRECTIONS ARE FOR THE | | | DUPLEX SERVICE. | | | | | | 1} THE LOAD CALCULATIONS SUBMITTED | | | REQUIRE A MINIMUM OF A 225 AMP SERVICE. | | | | | | THIS WOULD ALSO REQUIRE THE SERVICE | | | CONDUCTORS TO BE A MINIMUM OF 3/0 CU PER | | | 310.15(B)(6). | | | | | | 2} THE #3 CU FEEDER FROM THE DISCONNECT | | | TO THE PANEL IS REQUIRED TO BE #2 CU | | | MINIMUM PER 310.15(B)(6). | | | | | | 3} SHOW AII CONDUIT AND CONDUCTOR SIZES | | | ON RISER PER 215.5. | | | | | | THE FOLLOWING COMMENTS REFER TO THE | | | "COTTAGE" REWIRE. | | | | | | 1} THE PANEL LOCATION APPEARS TO BE IN | | | VIOLATION OF CLEARANCE REQUIREMENTS OF | | | 110.26. PLEASE INDICATE REMEDY FOR | | | COMPLIANCE. | | | | | | 2) PLEASE SEE RECEPTACLES NEED TO BE | | | ADDED IN THE FOLLOWING AREAS: | | | A) BEDROOMS 1,2& 3,LIVING ROOM, DINING | | | ROOM, AND "PORCH" FOR COMPLIANCE OF | | | 210.52(A), AND IN THE FRONT AND REAR OF | | | THE HOUSE FOR 210.52(E). | | | | | | ALSO PLEASE ADJUST THE VALUE ON THE | | | PERMIT TO REFLECT ALL LABOR AND MATERIAL | | | COSTS PER 104.6.5 FBC AMMENDMENTS,CWPB. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
09:04 |
Sent To |
E |
|
| Notes |
| 2005-01-31 00:00:00 | TO "BT" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-11 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-11 |
Time |
11:05 |
Sent To |
E |
|
| Notes |
| 2005-01-11 00:00:00 | TO "E" BOX. |
|
|
|