| Plan Review Stops For Permit 05010365 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-27 |
Time |
14:05 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-06-27 |
Time |
14:05 |
Sent To |
PC |
|
| Notes |
| 2005-06-27 00:00:00 | 6/27/05 | | | SHOP DRAWINGS BAR JOIST, TILT WALL, | | | STEEL BEAMS & ROOF REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-17 |
Time |
13:59 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-06-17 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2005-06-17 00:00:00 | 06-17-05REV# 1 DATED 5-23-05OK JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-06-29 |
Time |
08:49 |
Rev Time |
0.56 |
| Received By |
jwitmer |
Date |
2005-06-16 |
Time |
12:34 |
Sent To |
PC |
|
| Notes |
| 2005-06-16 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010365 | | | ADD: 5133 TYLER LAKES | | | CONT: HEDRICK BROTHERS | | | TEL: (561)267-4292 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | SUBMITTAL/ TILT WALL | | | ACTION: DENIED | | | | | | PLEASE SUBMIT (3) SETS OF ALL | | | SUBMITTALS, REVISIONS, PLANS OR REPORTS, | | | THERE IS A RESIDENT INSPECTOR ON SITE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-06 |
Time |
09:40 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-04-27 |
Time |
07:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-14 |
Time |
12:09 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2005-03-14 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2005-03-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010365 | | | ADD: 5133 TYLER LAKES BLVD | | | CONT:(PLAN REVIEW) | | | TEL: (248)721-3131 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) COMMENT #1 FROM THE FIRST REVIEW: | | | THE ARCHITECTURAL FIRM "ARCADIS" | | | DOES NOT HAVE A CERTIFICATE OF | | | AUTHORIZATION IN THE STATE OF FLORIDA, | | | CORRECT TITLE BLOCK TO READ THE | | | ARCHITECTS NAME AND LICENSE NUMBER. | | | 481.219 F.S. CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ARCHITECT | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ARCHITECTURAL SERVICES, SHALL INCLUDE | | | THE CERTIFICATE OF AUTHORIZATION NUMBER. | | | | | | 2) COMMENT #2 FROMTHE FIRST REVIEW: | | | THE ENGINEERING FIRM "MILLER LEGG & | | | ASSOC2IATES"REQUIRES A CERTIFICATE OF | | | AUTHORIZATION, 471.023 F.S. | | | CERTIFICATE OF AUTHORIZATION.THE TITLE | | | BLOCK FOR ANY SHEET BEARING THE NAME OF | | | AN ENGINEER PRACTICING UNDER A | | | FICTITIOUS NAME, A CORPORATION, OR A | | | PARTNERSHIP, OFFERING ENGINEERING | | | SERVICES, SHALL INCLUDE THE CERTIFICATE | | | OF AUTHORIZATION NUMBER. | | | | | | 3) COMMENT #4 FROM THE PEVIOUS REVIEW: | | | THREE (3) SOILS REPORTS ARE REQUIRED. | | | FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 4)COMMENT #8 FROM THE PEVIOUS REVIEW: | | | FBC* 105.3RESIDENT INSPECTOR. SUBMIT | | | INSPECTOR RESUME' AND LICENSE DOCUMENTS | | | TO HAROLD PISKURA, DIRECTOR OF THE | | | RESIDENT INSPECTOR PROGRAM.A RESIDENT | | | INSPECTOR PROGRAM IS REQUIRED, ON THIS | | | PROJECT, DUE TO ONE OR MORE OF THE | | | FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | ALSO, PLEASE ARRANGE WITH HAROLD PISKURA | | | (INSPECTION SERVICES MANAGER - TEL: | | | 561 805 6711), A MEETING INVOLVING THE | | | OWNER, RESIDENT JOB INSPECTOR,& | | | CONTRACTOR. | | | | | | 5) THREE (3) SETS OF ALL REPORTS, | | | DRAWINGS, OR SUBMITTALS SHALL BE | | | REQUIRED FOR A RESIDENT INSPECTOR. | | | | | | 6)COMMENT # 15 FROM THE PREVIOUS REVIEW: | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE | | | REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7) COMMENT #16 FROM THE PREVIOUS REVIEW: | | | FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES (3 FOR | | | RESIDENT INSPECTOR) OF PRODUCT TESTING | | | REPORTS,MISSING REPORTS ARE AS FOLLOWS: | | | A) STOREFRONT- KAWNEER- FL627 THE | | | TECHNICAL DRAWINGS DO NOT MATCH THE | | | SUBMITTED DADE NOA! | | | B) MULLIONS- MULLION REPORT SUBMITTED | | | IS FOR ALENCO SINGLE HUNG WINDOWS | | | AND THE LENGHT LIMITATION OF 72". | | | C) NO SUBMITTALS FOR THE DOUBLE GLASS | | | FRONT DOORS! | | | D) OVERHEAD ROLL UP DOORS- SEE THE 600 | | | COIL-AWAYTECHNICAL SHEET D-308114 | | | THE 14' WIDE DOOR DOES NOT MEET THE | | | WIND PRESSURES. | | | | | | 8) WILL BE A PROVISO, THAT ALL SHOP | | | DRAWINGS ( TILT WALL, BAR JOIST) | | | SHALL BE REVIEWED BY THE DESIGN | | | PROFESIONALS AND APPROVED BEFORE | | | SUMITTAL TO THE BUILDING DEPARTMENT. | | | | | | 9) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) COMPILE PLANS (STAPLE) INTO (3) | | | COMPLETE SETS OF DRAWINGS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2005-04-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-27 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-04-27 |
Time |
07:06 |
Sent To |
|
|
| Notes |
| 2005-04-27 00:00:00 | NO REVIEW COMPLETED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-25 |
Time |
07:22 |
Rev Time |
4.40 |
| Received By |
jwitmer |
Date |
2005-01-25 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010365 | | | ADD: 5133 TYLER LAKES BLVD | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) THE ARCHITECTURAL FIRM "ARCADIS" | | | DOES | | | NOT HAVE A CERTIFICATE OF AUTHORIZATION | | | IN THE STATE OF FLORIDA, CORRECT TITLE | | | BLOCK TO READ THE ARCHITECTS NAME AND | | | LICENSE NUMBER. 481.219 F.S. | | | CERTIFICATE OF AUTHORIZATION.THE | | | TITLE | | | BLOCK FOR ANY SHEET BEARING THE NAME OF | | | AN ARCHITECT PRACTICING UNDER A | | | FICTITIOUS NAME, A CORPORATION, OR A | | | PARTNERSHIP, OFFERING ARCHITECTURAL | | | SERVICES, SHALL INCLUDE THE CERTIFICATE | | | OF AUTHORIZATION NUMBER. | | | | | | ) THE ENGINEERING FIRM "MILLER LEGG & | | | ASSOC2IATES"REQUIRES A CERTIFICATE OF | | | AUTHORIZATION, 471.023 F.S. | | | CERTIFICATE | | | OF AUTHORIZATION.THE TITLE BLOCK FOR | | | ANY SHEET BEARING THE NAME OF AN | | | ENGINEER PRACTICING UNDER A FICTITIOUS | | | NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ENGINEERING SERVICES, SHALL | | | INCLUDE THE CERTIFICATE OF | | | AUTHORIZATION | | | NUMBER. | | | | | | 3)ENGINEER JAMES R. FOX FULL LEGAL | | | SIGNATURE REQUIRED, PLANS, | | | SPECIFICATIONS,REPORTS OR OTHER | | | DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE "FULL" SIGNATURE | | | AND SEAL OF THE DESIGN PROFESSIONAL | | | AFFIXED TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 4) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 5)SHEET T0.1 REVISE BUILDING CODE DATA, | | | ADA,TO FLORIDA ACCESSIBILITY CODE FOR | | | BUILDING CONSTRUCTION, CHAPTER 11 OF | | | THE | | | 2001 FLORIDA BUILDING CODE, 2003 | | | REVISIONS. FLORIDA AMERICANS WITH | | | DISABILITY ACCESSIBILITY IMPLEMENTATION | | | ACT,SECTION 553.501-553.513 | | | INCORPORATES INTO THE LAWS OF FLORIDA | | | THE ACCESSIBILITY REQUIREMENTSOF THE | | | ADA, WHILE AT THE SAME TIME TO MAINTAIN | | | THOSE PROVISIONS OF FLORIDA LAW THAT | | | ARE | | | MORE STREINGENT THAN THE ADA | | | ACCESSIBILITY GUIDELINES. | | | | | | 6) SHEET T).1 BUILDING CODE DATA, | | | CHAPTER 4 411.5.4 REPAIR GARAGE | | | "REPAIRS | | | ARE NOT TO TAKE PLACE IN THIS | | | FACILITY." | | | I DISCUSSED THIS ISSUE WITH THE | | | BUILDING | | | OFFIIAL, HE BELIEVE SINCE NO REPAIRS | | | ARE | | | TO TAKE PLACE, THE INSPECTION OF CARS | | | FROM ACCIDENT DAMAGE. CARS WILL BE | | | MOVED | | | IN & OUT OF THIS FACILITY JUST AS A | | | PARKING GARAGE, AND POSSIBILY MORE | | | FREQUENTLY, THEREFORE HE BELIEVE THAT | | | SECTION 411.4.2REQUIRING (6) AIR | | | CHANGES PER HR FITS THE DESCRIPTION OF | | | THE PROJECT BETTER THUS ENVOKING THIS | | | CODE SECTION. | | | | | | 7) F1.1 WORK STATIONS (108) ARE PART OF | | | A EGRESS CORRIDOR AS POSITIONED THERE | | | IS | | | ONLY 2'-0" CLEAR, THE MINIMUM CORRIDOR | | | OR AISLE WIDTH IS 36" WITH A OCCUPANT | | | LOAD OF LESS THAN 50, 50 OR MORE | | | REQUIRES44", SEE TABLE 1004. | | | | | | 8)SHEET A3.1 INDICATES THE USE OF TILT | | | WALL PANELS, REQUIRING A SPECIAL | | | INSPECTOR, FBC* 105.3RESIDENT | | | INSPECTOR. SUBMIT INSPECTOR RESUME' AND | | | LICENSE DOCUMENTS TO HAROLD PISKURA, | | | ((561)805-6711) DIRECTOR OF THE | | | RESIDENT | | | INSPECTOR PROGRAM.A RESIDENT | | | INSPECTOR | | | PROGRAM IS REQUIRED, ON THIS PROJECT, | | | DUE TO ONE OR MORE OF THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL | | | DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 9) SHEET A3.1 & A5.2 INDICATE THE USE | | | OF | | | A PREMANUFACTURED CANOPY BUT NO PLANS | | | ARE SUBMITTED, IS THIS A STATE APPROVED | | | SYSTEM ( DEPARTMENT OF COMMUMITY | | | AFFAIRS)? SUBMIT ADDITIONAL | | | INFORMATION. | | | NO CANOPY PLANS SUBMITTED AT THIS TIME, | | | NO REVIEW CAN BE COMPLETED. | | | | | | 10) SHEET A6.1 DETAIL# 7 IS MISSING THE | | | | | | U.L. LISTING FOR THE HEAD OF WALL | | | FIRESTOPPING SYSTEM. | | | | | | 11) SHEET S2.1 CAST IN PLACE CONCRETE | | | NOTES CORECT ACI 318-02, ACI350-02. | | | | | | 12) SHEET A2.1 & A5.1 INDICATE ROOF | | | DRAINAGE WITH THU-WALL SCUPPERS BUT NO | | | EMERGENCY OVERFLOW SCUPPERS: | | | 1503.4.2 OVERFLOW DRAINS SHALL BE THE | | | SAME SIZE AS ROOF DRAINS, INSTALLED | | | WITH | | | THE INLET FLOW LINE LOCATED 2" ABOVE | | | THE | | | LOWEST POINT OF THE ROOF LINE. OVERFLOW | | | SCUPPERS SHALL BE A MINIMUM OF 4"IN | | | HEIGTH AND SHALL BE PLACED IN WALLS OR | | | PARARETS WITH THE INLET FLOW LINE | | | NOT LESS THAN 2" ABOVE THE ROOF | | | SURFACE. | | | | | | 13) SHEET A5.1 SEE DETAIL# 2,1503.4.4 | | | PROTECTION AGAINST DECAY & TERMITES. | | | CONDENSATE LINES & ROOF DOWN SPOUTS | | | SHALL DISCHARGE AT LEAST 1 FT. AWAY | | | FROM | | | THE STRUCTURE SIDEWALL, WHETHER BY | | | UNDERGROUND PIPING, TAIL EX- TENSIONS, | | | OR SPLASH BLOCKS. | | | | | | 14)1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS | | | THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE | | | ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 15)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | ****PLEASE SUBMIT THE COVERSHEET FOR | | | ALL | | | PRODUCT APPROVALS REQUIRED BY THE | | | STATE***** | | | | | | 16)FL BLD CODE 1606.1.5: COMPONENTS | | | & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) WINDOWS | | | B) GLASS BLOCK | | | C)MULLIONS | | | D) LOUVERS | | | E) EXTERIOR DOORS SOLID & GLAZED | | | F) OVERHEAD DOORS | | | G) STORM SHUTTERS | | | H) ROOFING ASSEMBLIES | | | | | | 17)1707.4.5.1 MULLIONS OCCURRING BETWEEN | | | INDIVIDUAL WINDOW AND GLASS | | | DOOR ASSEMBLIES. TESTING REPORTS ARE | | | REQUIRED BY AN APPROVED TESTING | | | LABORATORY OR BE ENGINEERED. | | | | | | 18)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 19)1606.4.4 ANCHOR METHODS. PROVIDE | | | INFORMATION FOR INSTALLATION OF DOOR | | | AND WINDOW BUCKS. | | | | | | 20)PROVIDE PLANS FOR TILT WALLS AND FOR | | | | | | BAR JOIST. | | | | | | 21)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-12 |
Time |
13:32 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-10-12 |
Time |
12:32 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-29 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-29 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2005-09-29 00:00:00 | REV FOR SHEET 3.2 5.1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-21 |
Time |
07:25 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-21 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2005-06-21 00:00:00 | REDLINED 700.12E FOR EM/EXT LT | | | CIRCUITING. | | | | | | REDLINED MCB REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-20 |
Time |
19:45 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-04-20 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2005-04-20 00:00:00 | REDLINED: | | | EM/EXT LTS WIRED PER 700.12E | | | REDLINED: | | | MCB SHALL BE INSTALLED IN MDP, W/ NO | | | EXCEPTIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-08 |
Time |
14:50 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-03-08 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | ********* UNSAT 2ND REVIEW ********* | | | | | | PLEASE SEE PLANS ARE STILL ONLY IN FOR | | | PLAN REVIEW AND HAVE NOT BEEN SUBMITTED | | | FOR PERMIT. | | | | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #1 NO, PLEASE INCLUDE ALL | | | REQUIRED LICENSE INFORMATION ON TITLE | | | BLOCKS FOR ALL TRADES AND FOR ALL SHEETS | | | AS REQUIRED UNDER FS 481.219,471.023 | | | FAC 61G1-16.004,61G15-23.002. | | | PLEASE SEE ATTACHED SHEETS FROM STATE | | | DBPR SITE PERTAINING TO FIRM SHOWN ON | | | PLANS. | | | THIS FIRM IS SHOWN AS "APPLICANT" AT | | | THIS TIME. | | | PLEASE SEE ALL TITLE BLOCKS. PH-SHEETS | | | ETC. | | | PLEASE ALSO BE AWARE, FIRM # SHOWN ON | | | PLANS AT THIS TIME APPEAR TO BELONG TO A | | | DIFFERENT FIRM. | | | PLEASE ALSO BE AWARE, FIRM NAME AS | | | REGISTERED WITH STATE MUST BE THE SAME | | | AS ON TITLE BLOCK. | | | PLEASE SEE THIS IS REQUIRED OF ALL | | | SHEETS AND TRADES WHEATHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 2)NOTE: NOTE #2, NO, PLEASE SEE SOME | | | SHEETS SEAL IS NOT CLEARLY VISABLE WITH | | | INFORMATION REQUIRED. PLEASE SEE FS | | | 471.025 FOR ENGINEERS AND 481.221 FOR | | | ARCH'S. | | | PLEASE ALSO SEE PLANS MUST BE SIGNED, | | | "DATED " AND SEALED. | | | LTR FROM ENGINEER MR. JAMES FOX WAS | | | RECIEVED AND PLACED IN FILE FOR | | | SIGNATURE VERIFICATION. | | | | | | 3)NOTE:NOTE #3, OK, BLDG TO REVIEW WIND | | | LOAD CALCULATIONS. | | | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE CWP AND | | | GRND ROD WAS ADDED, HOWEVER FOOTER | | | STEEL, WAS NOT SHOWN. PLEASE SEE PLANS | | | REFERENCE 250.50 FOR GES. PLEASE SEE FBC | | | 104.2.1, PLANS SHALL NOT CONTAIN | | | REFERENCE TO TECHNICAL CODES IN WHOLE OR | | | IN PART. | | | | | | 5)NOTE: NOTE #5, OK, NOT SHOWN PER | | | DETAIL NEC ARTICLES, HOWEVER ALL LOADS | | | ARE SHOWN AS CONNECTED LOAD W/OUT | | | DERATING. THIS IS OK. | | | | | | 6)NOTE: NOTE #6, NO, PLEASE SEE PREVIOUS | | | COMMENT WAS NOT TO CHANGE IDENTIFICATION | | | OF MDP TO MCB. IT WAS TO REQUIRE A MCB, | | | (MAIN CIRCUIT BREAKER). | | | PLEASE SEE MAIN IS SHOWN AS PART OF A | | | PANEL BOARD FOR SERVICE WHICH WILL | | | CONTAIN MORE THAN 6-SPACES FOR MEANS OF | | | DISC OF SERVICE. PLEASE SEE THAT A MCB | | | WILL BE REQUIRED.230.71A, 240.4 | | | | | | | | | 7)NOTE: NOTE #7 OK. | | | | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT ELECTRICLA | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD SHEETS AND INSERT | | | NEW REVISED SHEETS INTO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | PLEASE SEE ALL SHEETS WERE LOOSE IN | | | ROLLS? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-21 |
Time |
16:43 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-01-21 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | ************* UNSAT ****************** | | | | | | *PLEASE SEE THIS IS IN FOR "PLAN | | | REVIEW" | | | ONLY AND NOT SUBMITTED FOR PERMIT. | | | | | | | | | 1)NOTE: PLEASE VERIFY LICENSE | | | INFORMATION PLACED ON TITLE BLOCK FOR | | | FIRM. | | | PLEASE SEE THE REQUIRED CA # PER FS | | | 481.219/471.023 DOES NOT SEEM TO | | | CORRELATE WITH STATE WEBSITE. PLEASE SEE | | | COPY OF ATTACHED PRINT OUT FROM STATE | | | WHICH INDICATES A A DIFFERENT COMPANY | | | FOR LICENSE # SHOWN ON PLANS. | | | | | | 2)NOTE: PLEASE SEAL FOR ENGINEER MUST BE | | | RAISED,CLEAR AND VISABLE WITH ALL | | | INFORMATION ON SAID SEAL AS REQUIRED | | | UNDER FS 471.025 | | | PLEASE ALSO SEE PLANS APPEAR TO BE | | | "SIGNED" WITH INITIALS? IF THIS IS | | | INDEED THE LEGAL "SIGNATURE" FOR | | | ENGINEER, PLEASE PROVIDE A SIGNED,DATED | | | AND SEALED NOTORIZED LETTER FOR TO | | | AFFIRM LEAGAL SIGNATURE. THIS LTR WILL | | | BE PLACED IN OUT SIGNATURE FILE FOR ANY | | | POSSIBLE FUTURE REFERENCE. | | | | | | 3)NOTE: PLEASE PROVIDE WIND LOAD | | | CALCUALTIONS FOR NEW SITE LIGHTING POLES | | | AND FIXTURES. THIS IS REQUIRED AT THIS | | | TIME AND MUST MEET FBC 140 MIN. | | | | | | 4)NOTE: PLEASE VERIFY GROUNDING | | | ELECTRODE SYSTEM. RISER INDICATES "SEE | | | SPEC", YET INFORMATION REQUIRED PER | | | 250.50 COULD NOT BE LOCATED. | | | PLEASE SHOW MIN CWP, FOOTER STEEL AND | | | ANY OTHER METAL BLDG AS PART OF GE | | | SYSTEM. | | | | | | 5 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | PLEASE ALSO SEE 220.12 FOR TRACK | | | LIGHTING LOADS. | | | PLEASE SHOW. | | | | | | 6)NOTE: PLEASE INDICATE MDP AS MCB. | | | 240.4. 215.5 | | | | | | 7)NOTE: PLEASE SEE 2002 NEC ART 511 | | | PLEASE PLACE NOTE ON PLANS IF "NO | | | SERVICE" ON VEHICLES. | | | | | | PLEASE SEE OTHER POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-03-29 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2005-03-29 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2005-03-29 00:00:00 | PASSED : | | | | | | 1. SEE PERMIT # 05031570 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-03-01 |
Time |
15:05 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-03-01 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | FAILED: | | | | | | 1. CIVIL PLANS MUST BE APPROVED BY THE | | | PUBLIC UTILITIES AND ENGINEERING PRIOR | | | TO SUBMITTING TO THE CONSTRUCTION | | | SERVICES FOR THE ACTUAL PERMITTING. | | | 2. SEE SHEET C2.1 FOR DUMPSTER ENCLOSURE | | | DETAILS.AS SHOWN ON SHEET 3 OF 11 DOES | | | NOT COMPLY WITH CITY' REQUIREMENTS. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-01-11 |
Time |
15:49 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-01-11 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | FAILED: | | | | | | 1. REVIEW COMMENTS BY THE PUBLIC | | | UTILITIES AND ENGINEERING MUST BE | | | ADDRESSED AND IMPLEMENTED INTO THE | | | CIVIL PLANS PRIOR TO SUBMITTING FOR | | | ACTUAL PERMITTING. | | | 2. DUMPSTER ENCLOSURE MUST BE SIZED PER | | | CITY OF WPB'S REQUIREMENTS IF GARBAGE | | | IS TO BE PICKED UP BY THE CITY; 12'-6" | | | OPENING BETWEEN THE GATE POSTS,INTERIOR | | | DIMENSIONS 12'-6" AND 12'-0" DEEP. | | | 3. FIRE DEPT. CONNECTION SHOULD BE | | | LOCATED PASSED THE FIRE HYD. IN THE | | | ISLAND AREA, AS PROPOSED WILL CREATE A | | | LOOP WITH NO AFFECT ON PRESSURE. PLEASE | | | VERIFY WITH FIRE DEPARTMENT, CAPT. NATE | | | MCCRAY 805-6722. | | | 4. PLEASE VERIFY THE CONSTRUCTION OF | | | THE DETECTABLE SURFACE AT THE EXIT INTO | | | TYLERLAKES BLVD. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-10-12 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-10-12 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2005-10-12 00:00:00 | REVISION DATED 9/28/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-06-28 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-06-28 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2005-06-28 00:00:00 | REVISION DATED 5/27/05 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-09 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-29 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-29 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2005-03-29 00:00:00 | DENIED | | | | | | 1) PLANS SHOW AN ACCESS GATE INTO THE | | | PROPERTY. PLEASE INCLUDE THE WIDTH | | | DIMENSION WHICH SHALL BE A MINIMUM OF 20 | | | FEET FOR EMERGENCY VEHICLES. | | | | | | 2) A KNOX KEY ENTRY WILL BE PROVIDED. | | | WHAT WILL SERVE AS THE BACK UP IN THE | | | EVENT OF POWER FAILURE? | | | | | | 3) PLEASE SHOW THE LOCATION OF FIRE | | | HYDRANTS. BE ADVISED THAT A FIRE HYDRANT | | | MUST BE LOCATED NOT FURTHER THAN 150 | | | FEET FROM THE CLOSEST HYDRANT. | | | | | | 4) PLEASE BE ADVISED THAT AN ADDRESS | | | NUMBER IS REQUIRED ON THE BUILDING. THE | | | NUMBERS SHALL BE AT LEAST 6" IN HEIGHT | | | AND CONTRASTING TO THE BACKGROUND. | | | | | | 5) SEPARATE SHOP DRAWINGS AND PERMITS | | | WILL BE REQUIRED FOR THE FIRE SPRINKLER | | | AND FIRE ALARM SYSTEMS. | | | | | | 6) THE FIRE SPRINKLER SYSTEM SHALL BE | | | MONITORED BY A U.L. LISTED CENTRAL | | | STATION SERVICE. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-27 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-27 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2005-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-23 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-23 |
Time |
18:57 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-19 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-19 |
Time |
08:53 |
Sent To |
M |
|
| Notes |
| 2005-08-19 00:00:00 | TO "M" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-22 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-22 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2005-07-22 00:00:00 | TO "F" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
11:47 |
Sent To |
B |
|
| Notes |
| 2005-06-20 00:00:00 | TO JW DESK(3 SUBMITTALS) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
11:39 |
Sent To |
B |
|
| Notes |
| 2005-06-20 00:00:00 | TO JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-10 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-10 |
Time |
12:10 |
Sent To |
B |
|
| Notes |
| 2005-06-10 00:00:00 | TO JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-06-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-09 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-09 |
Time |
08:55 |
Sent To |
ENG |
|
| Notes |
| 2005-06-09 00:00:00 | TO 'ENG BOX'. REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2005-06-08 00:00:00 | TO 'COMM BD#37/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2005-06-01 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-26 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-26 |
Time |
09:07 |
Sent To |
FIRE |
|
| Notes |
| 2005-05-26 00:00:00 | TO "MWENNEGREN" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-12 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-12 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2005-04-12 00:00:00 | TO "COMM" BD#4/PLANS ON RACK 1 ROLL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-12 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-14 |
Time |
14:39 |
Sent To |
Z |
|
| Notes |
| 2005-04-12 00:00:00 | TO "Z" BOX/PLEASE SEE INCOMING STOP | | | UNDER 05040494 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-01 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-01 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | TO "COMM" BD#56/"COMM" RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-02-03 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-01-10 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2005-01-10 00:00:00 | TO "COMM BD#63" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-10-12 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-10-12 |
Time |
11:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-30 |
Time |
09:01 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2005-09-30 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-08-29 |
Time |
16:37 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2005-08-29 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | *** MECH. REVISION *** | | | PASSED. SHOWING R/A GRILLS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-29 |
Time |
12:49 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2005-06-29 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2005-06-29 00:00:00 | PROVISO: | | | CO SENSORS SHALL BE TESTED FOR FINAL | | | INPECTION.PLEASE NOTE, CO SENSORS ARE | | | TO INITIATE AUTOMATICALLY AT A MAXIMUM | | | OF 25 PPMIN ACCORDANCE WITH 2001 | | | FBC(M)403.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-19 |
Time |
09:28 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2005-05-19 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2005-05-19 00:00:00 | PROVISO: | | | 1.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | REQUIRED WITH NOTIFICATION TO | | | ALARM/STROBE IN NORMALLY OCCUPIED AREAS. | | | | | | 2.THE LOCATION OF THE ACCU-1 APPEARS | | | TO BE "INSIDE".CONDENSOR UNITS ARE TO | | | BE INSTALLED "OUTSIDE" (OUTDOORS) PER | | | THE MANUFACTURER'S SPECIFICATIONS. | | | PLEASE REVISE PLANS TO RE-LOCATE ACCU-1. | | | | | | PER 2001 FBC CHAPTER 13 SUB SECTION | | | 407.1.ABCD.3.3, THE CONDENSING COIL OF | | | ONE AIR CONDITIONING UNIT SHALL NOT BE | | | INSTALLED IN THE COOL AIR STREAM OF | | | ANOTHER AIR CONDITIONING UNIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-22 |
Time |
09:29 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-03-22 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | DENIED: | | | COMMENT #3 FROM PREVIOUS REVIEW - PLANS | | | ARE TO BE SIGNED BY THE ENGINEER IN | | | ACCORDANCE WITH FS 471.025 & FAC | | | 61G15-23.002.PROVIDE A COPY OF DRIVES | | | LICENSE OR STATE ID SHOWING LEGAL | | | SIGNATURE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-26 |
Time |
06:43 |
Rev Time |
1.45 |
| Received By |
pkrauss |
Date |
2005-01-25 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2005-01-26 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS PER 2001 FBC(M) TABLE | | | 403.3.PLEASE INCLUDE OFFICE AREAS AS | | | WELL AS THE GARAGE AREAS. | | | | | | 2.IT IS THE DETERMINATION OF THE | | | BUILDING OFFICAL SINCE THIS IS NOT | | | CLASSIFIED AS A "REPAIR GARAGE" AND | | | SINCE CARS WILL BE MOVED IN AND OUT, | | | THAT IT SHALL BE CLASSIFIED AS A | | | "PARKING GARAGE".PLEASE SHOW | | | COMPLIANCE WITH THE 2001 FBC 411.4.2. | | | | | | 3.PLEASE REFERENCE COMMENTS BY | | | ELECTRICAL & BUILDING ON THE SIGNATURER, | | | TITLE BLOCK AND CERTIFICATE OF | | | AUTHORIZATION FOR THE ARCHITECTURAL & | | | ENGINEERING FIRMS (FS 471.023, 471.025 & | | | 481.219). | | | | | | 4.PLEASE NOTE, PLAN SHEET M2.1 | | | INDICATES GAS FIRED HEATERS AS WELL | | | HORIZONTAL UNIT HEATER (ELECTRIC). | | | PLEASE CLARIFY THE PURPOSE OF THE | | | ELECTRIC HEATER IN THE MECHANICAL ROOM. | | | | | | | | | 5.PROVIDE COMBUSTION AIR CALCULATIONS | | | FOR THE GHUH INDICATED ON PLAN SHEETS | | | M2.1 & M7.1. | | | | | | 6.PLEASE PROVIDE MANUFACTURER | | | SUBMITTAL DATA FOR ALL MECHANICAL | | | EQUIPMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-24 |
Time |
18:34 |
Rev Time |
0.49 |
| Received By |
kstevens |
Date |
2005-06-24 |
Time |
18:34 |
Sent To |
|
|
| Notes |
| 2005-06-24 00:00:00 | REVISION OK - SHT P7.1 DETAIL #6 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-18 |
Time |
14:10 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2005-05-14 |
Time |
19:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-18 |
Time |
19:07 |
Rev Time |
3.33 |
| Received By |
kstevens |
Date |
2005-03-18 |
Time |
19:07 |
Sent To |
|
|
| Notes |
| 2005-03-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A) FOLLOWING COMMENTS WERE NOT ADDRESSED | | | OR NOT ADDRESSED SUFFICIENTLY. THE | | | COMMENT NUMBER SHALL STAY THE SAME TO | | | AVOID CONFUSION. | | | 1) SHTS IRR 1,2,&3 PRINTED NAME OF THE | | | PERSON SEALING THE PLANS IS REQURED ON | | | THE TITLE BLOCK. FAC 61G1-16.004(6) & FS | | | 481.2055. RESPONSE NOTED "OUR DOCUMENTS | | | DO NOT INCLUDE AN IRR SHEET SERIES". | | | THERE ARE IRRIGATION SHEETS SUBMITTED. | | | ALSO THE CERTIFICATE OF AUTHORIZTION IS | | | REQUIRED FOR ALL IRR. SHEETS. THIS IS | | | REQUIRED AS AN "AA" OR "AR" NUMBER AS | | | THE SHEETS WERE SIGNED & SEALED BY A | | | LANDSCAPE ARCHITECT. FS 481.219(2) | | | 3) OIL WATER SEPARATOR SHALL BE SIZED | | | AND APPROVED BY RODNEY COMPO, | | | ENVIRONMENTAL COMPLIANCE. WASTE ORD | | | #2938-96. (561) 837-4074 - RESPONSE | | | NOTED, BUT SEE ATTACHED SHEET FROM | | | RODNEY COMPO REQUIREING A 100 GAL OIL | | | WATER SEPARATOR. SEPARATE PERMIT | | | REQUIRED FOR SEPARATOR. | | | 10) ALL SHEETS, TITLE BLOCK FOR | | | ARCHITECT, THE COMPANY NAME IS NOT THE | | | SAME AS SHOWN ON THE DBPR LICENSE SEARCH | | | FOR THE CERTIFICATE OF AUTHORIZATION, | | | PLEASE MAKE THE CORRECTION ON THE TITLE | | | BLOCK, SHOW APPROIATE BUSINESS NAME. | | | (SEE ATTACHED SHEET FROM DBPR WEBSITE). | | | FAC 61G1-16.004 & FS 481.291 - ALL | | | SHEETS FOR ARCHITECT AND ENGINEER, THE | | | DATE THAT THE SEAL AND SIGNATURE IS | | | AFFIXED SHALL BE ON THE SEAL. FAC | | | 61G15-23.002(2) - FAC 61G1-16.003 / FS | | | 471.025 - 481.2055. | | | 11) SUBMIT CALCULATIONS FOR MINIMUM | | | FACILITIES FOR FIXTURES. 2 DRINKING | | | FOUNTAINS ARE REQUIRED. SHT TO-1 | | | INDICATES A DRINKING FOUNTAIN IN LOBBY | | | AREA, BUT NO DRINKING FOUNTAIN IS SHOWN | | | ON THE FLOOR PLAN, NOR ON THE SANT. OR | | | WATER PIPING RISERS. ONLY ONE WATER | | | COOLER IS SHOWN. | | | 13) SHT PE.1 WATER RISER ISOMETRIC SHALL | | | SHOW FULL OPEN VALVES ON ALL EVER WATER | | | DOWN-FEED WATER LINE. SECTION 606.1(4) | | | ALL WATER HAMMER ARRESTORS SHALL BE | | | LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS | | | SHOWN. PDI-WH 201 & MANUF. INSTALL. | | | INSTRUCTIONS. | | | 15) A SEPARATE GAS PERMIT IS REQUIRED, | | | AND THE FOLLOWING INFORMATION IS | | | REQUIRED TO ISSUE THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. - NOT ALL LENGTHS ARE | | | SHOWN ON THE ISOMETRIC. SHOW LOCATION OF | | | METER AND ALL MEASURMENTS TO METER. | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). - THIS WAS | | | NOT SHOWN ON THE PLANS. | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. - | | | IF THE GAS DELIVERY PRESSURE IS .5 PSI, | | | DELETE ALL SECONDARY REGULATORS FROM THE | | | ISOMETRIC AS THEY WILL NOT BE IN SYSTEM. | | | ALL SHUT OFF VALVES SHALL BE LOCATE | | | MAXIMUM OF 6' FROM GAS APPLIANCE. | | | SECTION 409.7. SOME ARE SHOWN EXCEEDING | | | THIS REQUIREMENT ON THE ISOMETRIC. | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2. - NO | | | SHEETS WERE FOUND. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION.- | | | THE SHEETS THAT WERE VOIDED WERE NOT | | | REMOVED FROM THE SETS OF PLANS. REMOVE | | | ALL OLD SHEET AND SUBMIT ONE SET OF OLD | | | SHEETS FOR COMPARISON. - ONE SET OF | | | PLANS SUBMITTED FOR REVIEW WAS SUBMITTED | | | AS LOOSE SHEETS. PLEASE SUBMIT TWO OR | | | MORE SETS OF PLANS FOR REVIEW. SECTION | | | 104.2.1. | | | **************NEW COMMENT*************** | | | 1B) THE FOLLOWING SHEETS ARE NOT SHOWN | | | ON THE DRAWING INDEX, BUT WERE INCLUDED | | | IN THE SETS OF PLANS. SHEETS 1 THRU 11 | | | OF 11, SHEET 1 OF 1, L1 & L2, IRR 1,2,3 | | | PH-1, E1 OF 2, E1 OF 6. CORRELATE THE | | | INDEX SHEET WITH SHEETS SUBMITTED. | | | SECTION 104.2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-03 |
Time |
13:20 |
Rev Time |
12.00 |
| Received By |
kstevens |
Date |
2005-02-01 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2005-02-03 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHTS IRR 1, 2, & 3 PRINTED NAME OF | | | THE OF THE PERSON SEALING THE PLANS IS | | | REQUIRED ON THE TITLE BLOCK. FAC | | | 61G1-16.004(6) & FS 481.2055 | | | 2) SHT IRR 3 POINT OF CONNECTION, | | | (POC), | | | STATES 2" WATER METER. CIVIL SHEET 8 OF | | | 11 INDICATES 1" TAP. PLEASE CLARIFY. | | | SECTION 104.2.1. | | | 3) OIL WATER SEPARATOR SHALL BE SIZED | | | AND APPROVED BY RODNEY COMPO, | | | ENVIRONMENTAL COMPLIANCE. WASTE ORD. | | | NO. | | | 2938-96. (561)837-4074. | | | 4) SHTS F1.1 & A8.2 CLEAR FLOOR SPACE | | | FOR WATER CLOSETS AND URINAL ARE | | | REQUIRED IN THE MENS TOILET ROOM. ALSO | | | SHOW THE TURNING ARE IN THE TOILET ROOM | | | NOT THE ACCESSIBLE STALL. - CLEAR FLOOR | | | SPACE FOR THE WATER CLOSET IS REQUIRED | | | IN THE WOMENS TOILET ROOM, WITH THE | | | TURNING AREA SHOWN IN THE TOILET ROOM | | | NOT THE ACCESSIBLE STALL. SECTIONS | | | 11-4.16.2, 11-4.18.3 & 11-4.22.3- | | | ALSO | | | SHOW THE CLEAR FLOOR SPACE FOR THE W/C | | | IN ROOM #106, THE CLEAR FLOOR SPACE FOR | | | THE BREAK ROOM SINK IN ROOM #115, | | | (FORWARD APPROACH IS REQUIRED - MAX. | | | 19" | | | UNDERNEATH THE SINK), 11-4.24.5. | | | 5) SHTS F1.1 & A8.2 BREAK ROOM SINK | | | MODEL #CR-25-21 INDICATES A 7" DEEP | | | SINK, BUT SECTION 11-4.24.4 STATES THAT | | | 6-1/2" IS THE MAXIMUM DEPTH. ALSO | | | FAUCET | | | SHALL BE LEVER OPERATED, PUSH TYPE, | | | TOUCH TYPE, OR ELECTRONICALLY | | | CONTROLLED. SECTION 11-4.24.7 | | | 6) SHT A1.2 ROOM FINISH SCHEDULE, MORE | | | INFORMATION FOR WB-1 & WB-2 SHOWN FOR | | | THE BASE. INDICATE MATERIAL TYPE. PER | | | SECTION 1204.2 MATERIAL SHALL BE NOT | | | ABSORBENT. PLEASE CLARIFY. | | | 7) SHT A1.2 ROOM FINISH NOTE #3. | | | INDICATE THAT WAINSCOT IS REQUIRED. | | | SECTION 104.2.1. & SECTION 1204.2. | | | 8) SHT A2.1 SUBMIT CALCULATIONS FOR | | | ROOF | | | DRAINS PER SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW TOTAL AREA OF THE | | | ROOF | | | AND SHOW 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS. INDICATE THE AREA | | | OF | | | THE ROOF THAT DRAINS TO EACH DOWNSPOUT. | | | SHOW SIZE OF GUTTERS PER TABLE 1106.6, | | | INDICATE SLOPE OF GUTTERS AND SHOW THE | | | HIGH POINT OF THE GUTTER. | | | 9) SHT A8.1 DETAIL #2 SHOW KNEE | | | CLEARANCE 11-4.23.3, ACCESSIBLE WATER | | | CLOSET SHOW HEIGHT 11-4.16.3, | | | ACCESSIBLE | | | URINAL SHOW HEIGHT 11-4.18.2, CLEAR | | | FLOOR SPACE 11-4.18.3. | | | 10) ALL SHEETS, TITLE BLOCK FOR | | | ARCHITECT, THE COMPANY NAME IS NOT THE | | | SAME AS SHOWN ON DBPR LICENSE SEARCH | | | FOR | | | THE CERTIFICATE OF AUTHORIZATION. | | | PLEASE | | | MAKE THE CORRECTION ON THE TITLE BLOCK. | | | SHOW APPROIATE BUSINESS NAME. FAC | | | 61G1-16.004 & FS 481.291. - AN ENGINEER | | | SHALL SIGN HIS NAME AND AFFIX HIS SEAL | | | TO ALL PLANS. INITIALS ARE NOT | | | ACCEPTABLE. THE DATE THAT THE SIGNATURE | | | AND SEAL IS AFFIXED SHALL BE ENTERED ON | | | THE PLANS IMMEDIATELY UNDER THE | | | SIGNATURE OF THE PROFESSIONAL ENGINEER. | | | FAC 61G15-23.002(1) & FS 471.025 | | | 11) SUBMIT CALCULATIONS FOR MINIMUM | | | FACILITIES FOR FIXTURES. INDICATE ON | | | PLANS THE SQUARE FOOTAGE FOR EACH | | | OCCUPANCY. TABLES 1003.1 & 403.1. | | | 12) SHT P2.1 HOUSE TRAP NOT APPROVED. | | | DELETE FROM DETAIL "B". SECTION 1002.1 | | | 12) SHT P3.1 ALL RISER DIAGRAMS SHALL | | | BE | | | IN ISOMETRIC FORM AND SHALL REFLECT THE | | | FLOOR PLAN. SECTION 104.2.1. | | | 13) SHT P3.1 WATER RISER ISOMETRIC | | | SHALL | | | SHOW VALVES REQUIRED BY SECTION | | | 606.1(4) | | | FULL OPEN VALVES ON EVERY DOWN-FEED | | | WATER LINE, AND SHOW THE LOCATION OF | | | ALL | | | WATER HAMMER ARRESTORS REQUIRED BY | | | SECTION 604.9 AND SHALL BE LOCATED NEAR | | | THE FIXTURE, IN AN "EFFECTIVE RANGE" | | | NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | 14) SHT P3.1 INSPECTION BAY WASTE & | | | VENT | | | INDICATES A VERTICAL VENT FOR THE 4" | | | FD-3 ON RISER DIAGRAM, BUT ON SHT P2.1 | | | THE VENT IS INDICATED AS A HORIZONTAL | | | DRY VENT WHICH IS NOT APPROVED PER | | | SECTION 905.3 & 905.4 PLEASE CLARIFY. | | | 15) A SEPARATE GAS PERMIT IS REQUIRED, | | | AND THE FOLLOWING INFORMATION IS | | | REQUIRED TO ISSUE THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING | | | USED. | | | C. TYPE OF GAS, (LP OR NATURAL) | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2001 FUEL GAS CODE SECS. 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM | | | PER | | | FBC-2001 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES (A)(3). | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | H. SUBMIT MANUFACTURE SHEETS FOR ALL | | | GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | I. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY | | | LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, | | | BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | J. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK | | | AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | K) INDICATE TYPE OF MATERIAL FOR | | | REGULATOR VENTS. VENT MATERIAL SHALL BE | | | NON COMBUSTABLE. SECTION 631.15 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-06-29 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-06-29 |
Time |
08:46 |
Sent To |
I |
|
| Notes |
| 2005-06-29 00:00:00 | APPLICANT SUBMITTED MINOR PD AMENDMENT | | | CASE NO. 1239N WHICH WAS APPROVED ON | | | 6/29/05.ALL PREVIOUS CONDITIONS OF | | | APPROVAL HAVE BEEN SATISFIED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-10 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-10 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | DENIED, | | | 1. APPROVED SITE PLAN AND LANDSCAPE PLAN | | | NOT SUBMITTED, PLEASE RESUBMIT WITH NEW | | | SITE PLAN ADDED WALLS AROUND SECURITY | | | FENCE. | | | | | | JOSH LONG | | | SENIOR PLANNER | | | PLANNING & ZONING | | | 822-1449 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-13 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-13 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | DENIED, BY JOSH LONG, PLANNER 822-1435. | | | NEED TO MAKE CHANGES TO SCREEN PARKING. | | | CALLED CONTRACTOR. |
|
|