Plan Review Details - Permit 05010286
Plan Review Stops For Permit 05010286
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-05-16 Cont ID  
Sent By jwitmer Date 2005-05-16 Time 12:47 Rev Time 0.77
Received By jwitmer Date 2005-05-16 Time 12:20 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-01-24 Cont ID  
Sent By jwitmer Date 2005-01-24 Time 08:23 Rev Time 1.00
Received By jwitmer Date 2005-01-24 Time 07:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-05-11 Cont ID  
Sent By dpalmer Date 2005-05-11 Time 07:44 Rev Time 0.50
Received By dpalmer Date 2005-05-10 Time 16:44 Sent To B
Notes
2005-05-11 00:00:00REDLINED 250.30 FOR TRANSFORMERS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-11 Cont ID  
Sent By dpalmer Date 2005-01-11 Time 14:51 Rev Time 0.50
Received By dpalmer Date 2005-01-11 Time 14:51 Sent To  
Notes
2005-01-11 00:00:00********** UNSAT ***************
  
 1)NOTE: PLEASE SEE MISSING CA #
 REQUIRED
 TO BE PRINTED ON TITLE BLOCK PER FAC
 61G15-23.002, FS 471.023
 PLEASE SEE THIS WAS HANDWRITTEN ON
 TITLE
 BLOCKS, HOWEVER, DUE TO PLANS COMING
 BACK FOR CODE REVIEW COMMENTS, PLEASE
 ADD THIS IN CAD AT THIS TIME.
  
 2)NOTE: PLEASE VERIFY NEUTRAL CONDUCTOR
 REQUIRED TO THE FIRST MEANS OF DISC.
 PLEASE SEE REQUIREMENTS FOR METER.
 PLEASE SEE NEUTRAL IS ONLY REQUIRED TO
 FIRST MEANS OF DISC AND NOT TO
 TRANSFORMER AS IT THEN BECOMES A
 SEPARATELY DERIVED SYSTEM.
 20.6,250.24 ETC.
  
 3)NOTE: PLEASE SHOW ATTACHMENT FOR
 GROUNDING OF TRANSFORMER PER 250.30
 SHOWS , GRND BUT NOT ATTACHMENT.(MAY BE
 NOTE).
  
 4)NOTE: PLEASE SUBMIT LOAD CALCS FOR
 ADDITON OF NEW LOAD TO AN EXISTING
 SYSTEM. PER 215.5,220
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIE WAND STAMPING.
 PLEASE SUBMIT ONLY ONE COPY OF OLD
 SHEETS FOR REFERENCE ONLY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-01-27 Cont ID  
Sent By mcarsill Date 2005-01-27 Time 14:13 Rev Time 0.00
Received By mcarsill Date 2005-01-27 Time 14:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-05-10 Cont ID  
Sent By adarroug Date 2005-05-10 Time 10:38 Rev Time 0.00
Received By adarroug Date 2005-05-10 Time 10:38 Sent To E
Notes
2005-05-10 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-07 Cont ID  
Sent By mjacobs Date 2005-01-31 Time 08:23 Rev Time 0.00
Received By mjacobs Date 2005-01-07 Time 14:46 Sent To  
Notes
2005-01-07 00:00:00TO "COMM BD#16

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-31 Cont ID  
Sent By mmclean Date 2005-01-31 Time 08:17 Rev Time 0.00
Received By mmclean Date 2005-01-31 Time 08:17 Sent To  
Notes
2005-01-31 00:00:00APPROVED BY JOHN ROACH, PLANNER 822-1448