Plan Review Details - Permit 05010245
Plan Review Stops For Permit 05010245
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-06-01 Cont ID  
Sent By alange Date 2005-06-01 Time 11:44 Rev Time 0.50
Received By alange Date 2005-06-01 Time 11:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-05-18 Cont ID  
Sent By alange Date 2005-05-18 Time 11:28 Rev Time 0.33
Received By alange Date 2005-05-18 Time 11:27 Sent To  
Notes
2005-05-18 00:00:00ITEMS REQUIRED FOR PERMITTING.
  
 DENIED
  
  
 1. 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE
 RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 NOTE:388SQ. FT. OF A/C SPACE ADDED.
  
 3.ONLY ONE SET OF PLANS SUBMITTED FOR
 REVIEW.SUBMIT SECOND COPY.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-05-13 Cont ID  
Sent By alange Date 2005-05-13 Time 09:05 Rev Time 1.00
Received By alange Date 2005-05-13 Time 07:48 Sent To  
Notes
2005-05-13 00:00:00ITEMS REQUIRED FOR PERMITTING.
  
 DENIED
  
  
 1. 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE
 RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-04-27 Cont ID  
Sent By alange Date 2005-04-27 Time 10:36 Rev Time 1.25
Received By alange Date 2005-04-27 Time 07:26 Sent To  
Notes
2005-04-27 00:00:00ITEMS REQUIRED FOR PERMITTING.
  
 DENIED
  
  
 1. 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE
 RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 6. SHOW DOOR BUCK DETAIL.FBC
 1707.4.4.2
  
  
  
 8.BUILDING IS IN A FLOOD ZONE. SUBMIT
 AN EVAVATION CERTIFICATE TO BUILDING
 INSPECTOR SHOWING BUILDING IS A MINIMUM
 6" ABOVE BASE FLOOD ELAVATION.
 SHOW THIS ELAVATION ON PLAN.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT.
 THANKYOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-26 Cont ID  
Sent By alange Date 2005-01-26 Time 15:59 Rev Time 1.50
Received By alange Date 2005-01-26 Time 15:51 Sent To  
Notes
2005-01-26 00:00:00 
 PLAN REVIEW ONLY... THE FOLLOWING ITEMS
 ARE REQUIRED FOR PERMITTING OF THIS
 PLAN.
  
 DENIED
  
  
 1. 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE
 RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.CLEARLY SHOW ON PLANS EXISTING
 BUILDING AND ADJACENT ROOMS AND NEW
 CONSTRUCTION.
  
 4.PRODUCT APPROVALS REQUIRED FOR THE
 FOLLOWING WITH QUALITY ASSURANCE.
 ROOFING, EXTERIOR WINDOWS AND DOORS,
 IMPACT PROTECTION AND STRAPS AND
 TIE-DOWNS.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5. SHOW METHOD OF ROOF STRAPING AT D/4.
 AND 1/6.
  
 6. SHOW DOOR BUCK DETAIL.FBC
 1707.4.4.2
  
 7.SUBMIT 2 COPIES OF A SOILS REPORT.
  
 8.BUILDING IS IN A FLOOD ZONE. SUBMIT
 AN ELEVATION CERTIFICATE AND SHOW
 FINISH
 FLOOR HEIGHT ABOVE BASE FLOOD
 ELEVATION.
  
 9. IF FIREPLACE IS TO ON THE PERMIT
 APPLICATION ADDITION DRAWINGS WILL BE
 NEEDED.
  
 10.PLEASE NOT ZONEING REVIEW ABOUT
 JOINED ROOFS AND ADDRESS TABLE 600
 ISSUES WITH DISTANCES BETWEEN
 BUILDINGS.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-10-13 Cont ID  
Sent By dpalmer Date 2006-10-13 Time 10:51 Rev Time 0.00
Received By dpalmer Date 2006-10-13 Time 10:13 Sent To PC
Notes
2006-10-13 10:51:56REDLINED 210.8A AS REDLINED ON PREVIOUS REVIEWED PLANS.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-05 Cont ID  
Sent By dpalmer Date 2005-12-05 Time 10:22 Rev Time 0.00
Received By dpalmer Date 2005-12-05 Time 10:16 Sent To  
Notes
2005-12-05 00:00:00210.8A6

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-05-03 Cont ID  
Sent By dpalmer Date 2005-05-03 Time 18:58 Rev Time 0.30
Received By dpalmer Date 2005-05-03 Time 18:58 Sent To B
Notes
2005-05-03 00:00:00**** REDLINED PLANS ****
  
 1)NOTE: PLEASE SEE KITCHEN COUNTERSPACES
 STILL MISSING GFI RECEPTS AS REQUIRED
 UNDER 210.52C1.
 PLEASE SEE TWO PREVIOUS REVIEWS.
  
 PLANS HAVE BEEN REDLINED FOR THE ABOVE
 AND DO NOT NEED TO BE REVISED.
 IF PLANS ARE RESUBMITTED OR REVISED WITH
 ANY OTHER CHANGES, PLEASE REVISE AT THAT
 TIME.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-04-11 Cont ID  
Sent By dpalmer Date 2005-04-11 Time 09:16 Rev Time 0.30
Received By dpalmer Date 2005-04-11 Time 09:16 Sent To B
Notes
2005-04-11 00:00:00******* UNSAT *******
  
 1)NOTE: PLEASE SEE 210.52C1 FOR MISSING
 RECEPTS MISSING ALONG KITCHEN
 COUNTERSPACE.
  
 2)NOTE: PLEASE SEE 210.8A6, "ALL"
 RECEPTS SERVING KITCHEN COUNTERSPACE ARE
 REQUIRED TO BE GFI/GFI PROTECTED.
  
 3)NOTE: PLEASE SEE
 210.8,210.52D,210.11C3, BATH RECEPTS TO
 BE 20A AND #12, AND GFI
  
 4)NOTE: PLEASE SEE THE ABOVE THREE
 COMMENTS WERE ON THE FIRST REVIEW AND
 NONE OF THESECHANGES WERE MADE TO THE
 PLANS?
 PLEASE NOW SEE RESPONSE LETTER FROM MR
 ROBERT BELL (ARCHITECT) MENTIONS:
 "KITCHEN IS EXISTING AND WILL REMAIN
 UNCHANGED".
 PLEASE CLARIFY THIS AS PERMIT
 APPLICATION DOES NOT CORRELATE WITH
 THIS.
 PERMIT APPLICATION MENTIONS TO "GUT AND
 REMODEL KITCHEN".
  
 5)NOTE: PLEASE SUBMIT PLANS WHICH WILL
 CORRELATE WITH SCOPE OF WORK BEING
 APPLIED FOR. PLEASE SEE ABOVE FIRST
 THREE COMMENTS IF INDEED WORK IS BEING
 DONE IN KITCHEN AND BATH.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-18 Cont ID  
Sent By dpalmer Date 2005-01-18 Time 10:14 Rev Time 0.33
Received By dpalmer Date 2005-01-18 Time 10:14 Sent To B
Notes
2005-01-18 00:00:00************** UNSAT ******************
  
 PLEASE SEE PLANS ARE ONLY IN FOR PLAN
 REVIEW NAD NOT FOR PERMIT.
  
 1)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN
 COUNTERSPACE RECEPT SPACING.
  
 2)NOTE: PLEASE SHOW ALL RECEPTS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI
 PROTECTED.
  
 3)NOTE: PLEASE SHOW BATH GFI'S AS GFI
 PER 210.8, ALSO MUST NOTE AS 20A, #12,
 PER 210.11C3
  
 PLEASE SEE THESE ITEMS COULD BE
 REDLINED, HOWEVER PLANS ARE ONLY IN FOR
 "PLAN REVIEW".
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-10-04 Cont ID  
Sent By adarroug Date 2006-10-04 Time 16:50 Rev Time 0.00
Received By adarroug Date 2006-10-04 Time 16:50 Sent To E
Notes
2006-10-04 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-11-22 Cont ID  
Sent By adarroug Date 2005-11-22 Time 15:33 Rev Time 0.00
Received By adarroug Date 2005-11-22 Time 15:33 Sent To E
Notes
2005-11-22 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 16:33 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 16:33 Sent To B
Notes
2005-05-24 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-05-16 Cont ID  
Sent By adarroug Date 2005-05-16 Time 14:01 Rev Time 0.00
Received By adarroug Date 2005-05-16 Time 14:01 Sent To B
Notes
2005-05-16 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-29 Cont ID  
Sent By adarroug Date 2005-04-29 Time 13:49 Rev Time 0.00
Received By adarroug Date 2005-04-29 Time 13:49 Sent To E
Notes
2005-04-29 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-05 Cont ID  
Sent By adarroug Date 2005-04-05 Time 09:51 Rev Time 0.00
Received By adarroug Date 2005-04-05 Time 09:51 Sent To E
Notes
2005-04-05 00:00:00TO "DPALMER" DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-03-29 Cont ID  
Sent By adarroug Date 2005-03-29 Time 15:18 Rev Time 0.00
Received By adarroug Date 2005-03-29 Time 15:18 Sent To Z
Notes
2005-03-29 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-13 Cont ID  
Sent By mjacobs Date 2005-01-13 Time 16:10 Rev Time 0.00
Received By mjacobs Date 2005-01-13 Time 16:10 Sent To E
Notes
2005-01-13 00:00:00TO "E" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 16:08 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 16:08 Sent To Z
Notes
2005-01-06 00:00:00TO "Z" BOX.

Review Stop Z ZONING
Rev No 2 Status P Date 2005-04-01 Cont ID  
Sent By mmclean Date 2005-04-01 Time 10:49 Rev Time 0.00
Received By mmclean Date 2005-04-01 Time 10:49 Sent To I
Notes
2005-04-01 00:00:00OK BY ANGELLA JONES-VANN, ADMINISTRATOR

Review Stop Z ZONING
Rev No 1 Status F Date 2005-01-13 Cont ID  
Sent By mmclean Date 2005-01-13 Time 15:52 Rev Time 0.00
Received By mmclean Date 2005-01-13 Time 15:52 Sent To I
Notes
2005-01-13 00:00:00DENIED, MUST BE 6FT FROM MAIN STRUCTURE
 (FOR ANY ACCESSORY BLDG) AND CANNOT BE
 CONNECTED BY ROOF.PLEASE PROVIDE 2
 COPY OF SURVEY.