| Plan Review Stops For Permit 05010234 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-24 |
Time |
13:40 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-02-24 |
Time |
13:40 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-24 |
Time |
08:43 |
Rev Time |
77.00 |
| Received By |
jwitmer |
Date |
2005-01-24 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-11 |
Time |
11:18 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-11 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | SERVICE SHOWN AS EXISTING. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-25 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-25 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH | | | NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM | | | THE SITE DAILY. | | | | | | 3. PROPER VENTILATION IS TO BE | | | PROVIDED IF GASOLINE POWERED | | | EQUIPMENT IS USED FOR DEMOLITION | | | ACTIVITIES. PROPER VENTILATION | | | IS REQUIRED TO PREVENT CARBON | | | MONOXIDE BUILD-UP. | | | | | | 4. INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILINGS SHALL BE CLASS A | | | OR B IN EXITS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
09:21 |
Sent To |
P |
|
| Notes |
| 2005-02-22 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-08 |
Time |
08:31 |
Sent To |
P |
|
| Notes |
| 2005-02-08 00:00:00 | TO "P"BOX/RESUBMISSION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-26 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-01-07 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2005-01-07 00:00:00 | TO "COMM BD#24" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-25 |
Time |
07:16 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-01-25 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | PROVISO: | | | BALANCED AIR REQUIRED - PER 2001 FBC(M) | | | 601.4, PROVIDE RETURN AIR FROM AREAS | | | SEPARATED FROM THE CENTRAL RETURN (I.E., | | | OFFICE, LOUNGE, CONFERENCE, ETC.) | | | PLEASE PROVIDE A REVISED PLAN INDICATING | | | LOCATION AND SIZE OF RETURN AIR JUMPERS | | | AND TRANSFERS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-02-19 |
Time |
08:38 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2005-02-19 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2005-02-23 00:00:00 | SENT TO BUILDING NOT ELECTRICAL KS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-26 |
Time |
13:06 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-01-26 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2005-01-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 NOTE STATES "DRAWING | | | SUBMITTED FOR INFORMATION ONLY. | | | DEMOLITION PERMIT HAS ALREADY BEEN | | | APPLIED FOR BY CONTRACTOR". INFORMATION | | | FROM CONTRACTOR WITH DEMO PERMIT | | | INDICATES THAT THE DEMO PERMIT WILL BE | | | VOIDED, AND THAT THEY WILL NOT BE DOING | | | THE DEMOLITION. - THE VALUE OF THE | | | APPLICATION WILL BE ADJUSTED FOR THE | | | DEMOLITION AND THE APPLICATION AND | | | PERMIT WILL HAVE TO REFLECT THE DEMO | | | WORK, SECTION 104.2.1. NEW DEMO PLAN | | | REQUIRED. SECTION. | | | 2) SUBMIT A WATER RISER DIAGRAM. SHOW | | | ALL PIPE SIZES AND WHERE REQUIRED BY | | | SECTION 604.9 SHOW ANY WATER HAMMER | | | ARRESTORS LOCATED NEAR THE FIXTURES IN | | | AN "EFFECTIVE RANGE". PDI-WH 201. | | | SECTION 104.3.1.1. | | | 3) SHT A-2 LOUNGE SINK DETAIL. THE | | | FOLLOWING INFORMATION IS REQUIRED ON | | | THE | | | DETAIL TO SHOW COMPLIANCE WITH SECTION | | | 11-4.24 AND ALL SUBSECTIONS: | | | A) KNEE CLEARANCE 11-4.24.3 | | | B) DEPTH OF SINK11-4.24.4 | | | C) CLEAR FLOOR SPACE 11-4.24.5 FORWARD | | | APPROACH REQUIRED AND SHALL EXTEND A | | | MAXIMUM OF 19" UNDER THE SINK. | | | D) EXPOSED PIPES AND SURFACES | | | 11-4.24.6 | | | E) FAUCETS 11-4.24.7 | | | (NOTE: BUILDING OFFICIAL HAS DETERMINED | | | THAT THERE ARE TO BE NO DOORS UNDER THE | | | SINK IN THE CLEAR FLOOR SPACE) | | | 4) SHT A-2 SHOW THE CLEAR FLOOR SPACE | | | FOR THE DRINKING FOUNTAIN PER SECTION | | | 11-4.15.5(1). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|