Plan Review Details - Permit 05010234
Plan Review Stops For Permit 05010234
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-24 Cont ID  
Sent By jwitmer Date 2005-02-24 Time 13:40 Rev Time 0.77
Received By jwitmer Date 2005-02-24 Time 13:40 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-01-24 Cont ID  
Sent By jwitmer Date 2005-01-24 Time 08:43 Rev Time 77.00
Received By jwitmer Date 2005-01-24 Time 08:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-11 Cont ID  
Sent By dpalmer Date 2005-01-11 Time 11:18 Rev Time 0.50
Received By dpalmer Date 2005-01-11 Time 11:18 Sent To  
Notes
2005-01-11 00:00:00SERVICE SHOWN AS EXISTING.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-01-25 Cont ID  
Sent By mcarsill Date 2005-01-25 Time 15:34 Rev Time 0.00
Received By mcarsill Date 2005-01-25 Time 15:34 Sent To  
Notes
2005-01-25 00:00:001. DEMOLITION, RENOVATION, AND
 CONSTRUCTION TO COMPLY WITH
 NFPA 241.
  
 2. DEBRIS SHALL BE REMOVED FROM
 THE SITE DAILY.
  
 3. PROPER VENTILATION IS TO BE
 PROVIDED IF GASOLINE POWERED
 EQUIPMENT IS USED FOR DEMOLITION
 ACTIVITIES. PROPER VENTILATION
 IS REQUIRED TO PREVENT CARBON
 MONOXIDE BUILD-UP.
  
 4. INTERIOR FINISH CLASSIFICATION FOR
 WALLS AND CEILINGS SHALL BE CLASS A
 OR B IN EXITS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-22 Cont ID  
Sent By adarroug Date 2005-02-22 Time 09:21 Rev Time 0.00
Received By adarroug Date 2005-02-22 Time 09:21 Sent To P
Notes
2005-02-22 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-02-08 Cont ID  
Sent By adarroug Date 2005-02-08 Time 08:32 Rev Time 0.00
Received By adarroug Date 2005-02-08 Time 08:31 Sent To P
Notes
2005-02-08 00:00:00TO "P"BOX/RESUBMISSION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-07 Cont ID  
Sent By mjacobs Date 2005-01-26 Time 13:49 Rev Time 0.00
Received By kstevens Date 2005-01-07 Time 08:31 Sent To  
Notes
2005-01-07 00:00:00TO "COMM BD#24"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-25 Cont ID  
Sent By pkrauss Date 2005-01-25 Time 07:16 Rev Time 0.40
Received By pkrauss Date 2005-01-25 Time 07:09 Sent To  
Notes
2005-01-25 00:00:00PROVISO:
 BALANCED AIR REQUIRED - PER 2001 FBC(M)
 601.4, PROVIDE RETURN AIR FROM AREAS
 SEPARATED FROM THE CENTRAL RETURN (I.E.,
 OFFICE, LOUNGE, CONFERENCE, ETC.)
 PLEASE PROVIDE A REVISED PLAN INDICATING
 LOCATION AND SIZE OF RETURN AIR JUMPERS
 AND TRANSFERS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-02-19 Cont ID  
Sent By jleech Date 2005-02-19 Time 08:38 Rev Time 1.50
Received By jleech Date 2005-02-19 Time 08:38 Sent To E
Notes
2005-02-23 00:00:00SENT TO BUILDING NOT ELECTRICAL KS

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-26 Cont ID  
Sent By kstevens Date 2005-01-26 Time 13:06 Rev Time 1.25
Received By kstevens Date 2005-01-26 Time 13:06 Sent To  
Notes
2005-01-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-1 NOTE STATES "DRAWING
 SUBMITTED FOR INFORMATION ONLY.
 DEMOLITION PERMIT HAS ALREADY BEEN
 APPLIED FOR BY CONTRACTOR". INFORMATION
 FROM CONTRACTOR WITH DEMO PERMIT
 INDICATES THAT THE DEMO PERMIT WILL BE
 VOIDED, AND THAT THEY WILL NOT BE DOING
 THE DEMOLITION. - THE VALUE OF THE
 APPLICATION WILL BE ADJUSTED FOR THE
 DEMOLITION AND THE APPLICATION AND
 PERMIT WILL HAVE TO REFLECT THE DEMO
 WORK, SECTION 104.2.1. NEW DEMO PLAN
 REQUIRED. SECTION.
 2) SUBMIT A WATER RISER DIAGRAM. SHOW
 ALL PIPE SIZES AND WHERE REQUIRED BY
 SECTION 604.9 SHOW ANY WATER HAMMER
 ARRESTORS LOCATED NEAR THE FIXTURES IN
 AN "EFFECTIVE RANGE". PDI-WH 201.
 SECTION 104.3.1.1.
 3) SHT A-2 LOUNGE SINK DETAIL. THE
 FOLLOWING INFORMATION IS REQUIRED ON
 THE
 DETAIL TO SHOW COMPLIANCE WITH SECTION
 11-4.24 AND ALL SUBSECTIONS:
 A) KNEE CLEARANCE 11-4.24.3
 B) DEPTH OF SINK11-4.24.4
 C) CLEAR FLOOR SPACE 11-4.24.5 FORWARD
 APPROACH REQUIRED AND SHALL EXTEND A
 MAXIMUM OF 19" UNDER THE SINK.
 D) EXPOSED PIPES AND SURFACES
 11-4.24.6
 E) FAUCETS 11-4.24.7
 (NOTE: BUILDING OFFICIAL HAS DETERMINED
 THAT THERE ARE TO BE NO DOORS UNDER THE
 SINK IN THE CLEAR FLOOR SPACE)
 4) SHT A-2 SHOW THE CLEAR FLOOR SPACE
 FOR THE DRINKING FOUNTAIN PER SECTION
 11-4.15.5(1).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]