| Plan Review Stops For Permit 05010076 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-20 |
Time |
14:42 |
Rev Time |
1.66 |
| Received By |
jwitmer |
Date |
2005-05-20 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-20 |
Time |
14:42 |
Rev Time |
1.66 |
| Received By |
jwitmer |
Date |
2005-05-20 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-12 |
Time |
09:22 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-03-12 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2005-03-12 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010076 | | | ADD: 1400 NORTHPOINT PARKWAY# 10 | | | CONT:BRICAR ENTERPRISES INC | | | TEL: (561)675-1976 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1)COMMENT # 1B FROM THE PREVIOUS REVIEW: | | | RESPONSE FROM KAMM, THIS COMMENT TO BE | | | SUPPLIED BY OWNER. NO INFORMATION WAS | | | SUPPLIED. NUMBER OF TANKS AND SIZE OF | | | TANKS FOR EACH OF THE GASSES? | | | | | | COMMENT #3 WAS ANSWERED BY THE FIRE | | | REVIEW COMMENT #4 ABOUT RATING OF THE | | | ENCLOSURE WAS PARTIALLY ANSWERED BUT NO | | | MENTION OF AIR CIRCULATION? | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-21 |
Time |
13:43 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2005-01-21 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:05010076 | | | ADD: 1400 NORTHPOINT PKWY# 10 | | | CONT: BRICAR ENTERPRISES | | | TEL: (954)675-1976 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | | | | 1)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | THE NEW LAB DOESN'T INDICATE IF THERE | | | WILL BE FUME HOODS? WHAT QUANITIES OF | | | GASSES WILL BE STORED? | | | | | | 2) ALSO THE PLUMBING PAGES INDICATE THE | | | USE OF HYDROGEN TANKS IN A INCLOSURE | | | BUT THERE IS NO MENTION OF PIPING OF | | | HYDROGEN? | | | | | | 3)THE ENCLOSURE HOLDING THE HYDROGEN | | | TANK WHAT IS IT RATED FOR? | | | | | | 4) 1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-12 |
Time |
08:53 |
Rev Time |
0.60 |
| Received By |
dpalmer |
Date |
2005-01-12 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2005-01-12 00:00:00 | REDLINED 250.24,250.6 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-05-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-05-25 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-05-25 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-30 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-30 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2005-03-30 00:00:00 | 1) IN REGARDS TO THE FIRE SEPARATION FOR | | | THE CYLINDER STORAGE AREA, ALTHOUGH IT'S | | | EXISTING, WHAT IS THE FIRE SEPARATION? | | | | | | 2) IN REGARDS TO YOUR RESPONSE AS TO | | | WHAT SPECIAL PRECAUTIONS WILL BE TAKEN | | | WITH THE ACETYLENE AND ARGON, NO ANSWER | | | HAS BEEN PROVIDED BY THE OWNER. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-25 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-25 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | 1. THE ARGON, HELIUM, AND ACETYLENE | | | SHALL BE USED, STORED, AND HANDLED | | | IN ACCORDANCE WITH ALL APPLICABLE | | | CODES AND STANDARDS. | | | | | | 2. WHAT IS THE FIRE SEPARATION FOR | | | THE CYLINDER STORAGE AREA. | | | | | | 3. PLEASE INDICATE WHAT SPECIAL | | | PRECAUTIONS WILL BE TAKEN WITH | | | THE ACETYLENE AND ARGON. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-25 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-25 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2005-04-25 00:00:00 | TO "COMM" BD#43 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-02 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-02 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2005-03-02 00:00:00 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-01-05 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2005-01-05 00:00:00 | TO "COMM BD#14 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-13 |
Time |
06:52 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2005-06-13 |
Time |
06:45 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-06-07 |
Time |
06:41 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-06-06 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2005-06-07 00:00:00 | CALLED CONTRACTOR TO CORRELATE PLANS. | | | PLANS ARE CODE COMPLIANT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-05-26 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-05-26 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2005-05-26 00:00:00 | PLAN DENIED | | | COMMENTS1 THROUGH 6 FROM LAST REVIEW | | | WERE NOT ADDRESSED.PLEASE INLARGE | | | MECHANICAL PLANS SO ALL DUCT SIZES,CFM, | | | AND CAN SIZES CAN BE SEEN BY PLAN | | | REVIEWER AND INSPECTIOR. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-31 |
Time |
10:22 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2005-03-31 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2005-03-31 00:00:00 | DENIED: | | | COMMENTS 1 THORUGH 3, 5 & 6 FROM REVIEW | | | DATED 1-24-05 WERE NOT ADDRESSED. | | | RESPONSE LETTER FROM KAMM INDICATES THE | | | OWNER WILL ADDRESS.OWNERS COMMENTS | | | WERE NOT INCLUDED. | | | | | | PROVIDE THE AMOUNT OR QUANTITIES FOR ALL | | | OF THE PRODUCTS LISTED AND SUBMITTED ON | | | THE MATERIAL SAFETY DATA SHEETS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-24 |
Time |
16:50 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-01-24 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | DENIED: | | | 1. PLEASE INDICATE ON THE PLAN WHAT | | | TYPE | | | OF PROCESSES WILL TAKE PLACE IN THE | | | LAB. | | | | | | 2. PLEASE INDICATE WHAT APPLICATION THE | | | ARGON AND NITROGEN GASES WILL BE USED | | | FOR. | | | | | | 3. INDICATE CAPACITY OF THE BOTTLES OR | | | OR TANKS FOR THE GASES. | | | | | | 4. INDICATE VENTILATION FOR THE STORAGE | | | ROOM WHERE THE GASES WILL BE STORED (NEW | | | OR EXISTING). | | | | | | 5.WILL ANY OTHER TOXIC OR HAZARDOUS | | | CHEMICALS BE USED OR STORED IN THE LAB? | | | PROVIDE DETAILS ON STORAGE. | | | | | | 6.PROVIDE MSDS INFORMATION FOR ANY | | | HAZARDOUS OR TOXIC CHEMICALS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-16 |
Time |
17:28 |
Rev Time |
1.10 |
| Received By |
kstevens |
Date |
2005-06-16 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-06 |
Time |
06:53 |
Rev Time |
1.57 |
| Received By |
kstevens |
Date |
2005-06-04 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2005-06-06 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | | | | INITIALS ARE NOT ACCEPTABLE PER RULEING | | | BY FBPE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-18 |
Time |
13:49 |
Rev Time |
3.84 |
| Received By |
kstevens |
Date |
2005-03-18 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2005-03-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | A) FROM PREVIOUS REVIEW: | | | 1) MORE INFORMATION IS REQUIRED. | | | INDICATE THE USE OF THE GASES. SECTION | | | 104.2.1. RESPONSE NOTED, BUT NO | | | INFORMATION FROM THE OWNER HAS BEEN | | | SUBMITTED. | | | 4) INDIACTE THE AMOUNT AND TYPE OF GAS | | | STORED ON THE JOBSITE. SECTION 104.2.1. | | | RESPONSE NOTED, BUT NO INFORMATION FROM | | | OWNER HAS BEEN SUBMITTED. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-25 |
Time |
16:18 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2005-01-25 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2005-01-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | NFPA 99 | | | NFPA 54 | | | | | | 1) MORE INFORMATION IS REQUIRED. | | | INDICATE THE USE OF THE GASES. SECTION | | | 104.2.1. | | | 2) SHT PO.1 GENERAL GAS NOTES INDICATES | | | THAT ALL GAS LINES SHALL BE 1/8" BUT | | | THE | | | FITTINGS SHALL BE 7/8" SWEAGLOCK. | | | PLEASE | | | CLARIFY. SECTION 104.2.1. (ALSO SEE SHT | | | P5.1 RISER DIAGRAM SHOWS 1/2" PIPE). | | | 3) SHT P0.1 GENERAL GAS NOTES REFERENCES | | | NFPA 54 WHICH IS FOR NATURAL GAS. PLEASE | | | INDICATE WHERE THE NATURAL GAS SYSTEM IS | | | LOCATED AND SHOW PIPING DIAGRAM FOR THIS | | | SYSTEM. MORE COMMENTS MAY FOLLOW WITH | | | THE RESPONSE FROM THIS COMMENT. | | | 4) INDICATE THE AMOUNT AND TYPE OF GAS | | | STORED ON THE JOBSITE. SECTION 104.2.1. | | | 5) SHT P2.1 NOTES INDICATE (3) LINES | | | FROM HELIUM, NITROGEN, AND ACETLYENE | | | TANKS, - (2) LINES FROM ARGON AND | | | NITROGEN TANKS, - (4) LINES FROM ARGON, | | | BUT SHT P5.1 SHOWS 4 LINES, 1EA FROM | | | ARGON, HELIUM, ACETYLENE, & NITROGEN TO | | | EACH VALVE BOX. PLEASE CLARIFY. | | | 6) PLEASE INDICATE WHERE THE AIR AND | | | CH4 | | | GAS IS PIPED TO. THIS IS NOT INDICATED | | | ON THE PLANS. SECTION 104.2.1. | | | 7) SUBMIT MSDS SHEETS FOR ALL HAZARDOUS | | | MATERIALS STORED AND/OR USED ON THE JOB | | | SITE. SECTION 104.2.1. | | | 8) STH P5.1 SUBMIT A DETAIL FOR THE | | | VENTING FOR THE GAS TANK STORAGE ROOM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|