Plan Review Details - Permit 05010022
Plan Review Stops For Permit 05010022
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-25 Cont ID  
Sent By alange Date 2005-01-25 Time 16:45 Rev Time 2.00
Received By alange Date 2005-01-25 Time 10:25 Sent To  
Notes
2005-01-25 00:00:00DENIED
  
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 2. 713.13 F.S.A NOTICE OF
 COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST
 BE
 RE-RECORDED IF THE DESCRIBED
 IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3.BASED ON SBCCI BUILDING VALUATION
 DATA THE VALUATION HAS BE CHANGE TO
 $87,425.SEE PERMIT APPLICATION FOR
 BREAKDOWN OF COSTS.ADDITIONAL PERMIT
 FEES ARE DUE.
  
 4.PRODUCT APPROVALS ARE MISSING FOR
 METAL SIDING AND STRAPS AND TIE-DOWNS.
  
 NOTE: ALL PRODUCT APPROVALS (QUALITY
 ASSURANCE) REQUIRES THE FOLLOWING TO BE
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5.WINDOWS AT TUB AREA SHALL BE SAFTEY
 GLAZING.FBC2405.2.1PLEASE SHOW ON
 PLANS.
  
 6.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS.FBC 2309.6
  
 7.SHOW PRESSURES OF WINDOW OPENINGS.
  
 8."R" VALUES ON ENERGY CALCS DO NOT
 MATCH THOSE ON PLANS.
  
 9.SHOW ROOF SHEATHING NAILING
 SCHEDULE
 COMPLYING WITH FBC 2306.1 WPB
 AMMENDMENTS.
  
 10.PEIR PADS USED ARE REQUIRED TO BE
 ON A FOOTING AND STRAPPED DOWN.PLEASE
 SHOW ON PLANS.
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-01-12 Cont ID  
Sent By btrobaug Date 2005-01-12 Time 11:09 Rev Time 0.50
Received By btrobaug Date 2005-01-12 Time 09:33 Sent To P
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-01-04 Cont ID  
Sent By spalmer Date 2005-01-04 Time 12:17 Rev Time 0.15
Received By spalmer Date 2005-01-04 Time 12:17 Sent To  
Notes
2005-01-04 00:00:00OK PER SHERRY PILAND

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-10 Cont ID  
Sent By mjacobs Date 2005-01-10 Time 08:00 Rev Time 0.00
Received By mjacobs Date 2005-01-10 Time 08:00 Sent To E
Notes
2005-01-10 00:00:00TO "E" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-04 Cont ID  
Sent By mmclean Date 2005-01-07 Time 16:57 Rev Time 0.00
Received By mjacobs Date 2005-01-04 Time 14:23 Sent To Z
Notes
2005-01-04 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-18 Cont ID  
Sent By prafter Date 2005-01-18 Time 10:37 Rev Time 0.45
Received By prafter Date 2005-01-18 Time 10:36 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-15 Cont ID  
Sent By jleech Date 2005-01-15 Time 12:27 Rev Time 1.00
Received By jleech Date 2005-01-15 Time 12:27 Sent To M
Notes
2005-01-15 00:00:00DENIED;
 1.RISER DIAGRAMS ARE NOT TO CODE.
 KITCHEN SINK AND W/M ARE REQUIRED TO
 DISCHARGE DOWN STREAM OF A BATH ROOM
 GROUP SEC 909.1. KITCHEN SINK SHOULD BE
 A MECHANICAL VENT. NO WALL FOR VENT
 PIPE.
 2.MASTER BATHROOM RISER. PIPE SIZING
 MUST BE 3" DOWN STREAM OF A TOILET.
 DRAWING A TRAP FOR THE WATER CLOSET IS
 NOT REQUIRED. THE TRAP IS IN THE TOILET.
 PLEASE SEE RED LINE ON PLUMBING PAGE.
 3.PLEASE CHANGE NOT 15 TO SHOCK
 ARRESTORS TO BE INSTALLED PER SEC 604.9
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-07 Cont ID  
Sent By mmclean Date 2005-01-07 Time 16:24 Rev Time 0.00
Received By mmclean Date 2005-01-07 Time 16:24 Sent To I
Notes
2005-01-07 00:00:00NOTE: MUST PULL SEPERATE PERMIT FOR
 CONCRETE COLUMNS/GATE/WALL/FENCE
 PROVIDING UTILITY EASEMENT APPROVAL FROM
 CITY OF WEST PALM BEACH.MUST PROVIDE
 DIAGRAM TO SCALE SHOWING THE HEIGHT OF
 WALL/COLUMNS/GATE/FENCE.
  
 **REMINDER THAT WITHIN THE FIRST 25FT
 FRONT SETBACK HEIGHT ALLOWED IS 4FT
 MIN.
  
 CALLED CONTRACTOR REQUESTED THE WIDTH OF
 THE NEW PAVER DRIVEWAY, LEFT MSG ON
 VOICE MAIL.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved