| Plan Review Stops For Permit 05010021 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-03 |
Time |
15:18 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-02-03 |
Time |
15:17 |
Sent To |
PC |
|
| Notes |
| 2006-02-03 00:00:00 | FRONT DOOR PRODUCT APPROVAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-17 |
Time |
08:23 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-01-17 |
Time |
08:23 |
Sent To |
PC |
|
| Notes |
| 2006-01-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010021 | | | ADD: 201 PALMETTO LN | | | CONT: STERLING COMMUNITIES | | | TEL: (561)239-9740 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) FROM THE PREVIOUS REVIEW NOTE# 2. | | | | | | THE PRODUCT APPROVAL SUBMITTED DOES | | | NOT HAVE FL APPROVAL. IT STATES IN THE | | | REPORT IT IS BASED ON RULE 9B-72.40 | | | METHOD 1D. THIS IS A REPORT FROM A FL | | | REGISTERED ARCHITECT OR A FLORIDA | | | PROFESSIONAL ENGINEER WHO DEVELOPED AND | | | SIGNED AND SEALED, BASED UPON TESTING OR | | | COMPARATIVE ANALYSIS, OR A COMBINATION | | | THEREOF WHICH PROVIDES VERIFIABLE | | | DOCUMENTATION INDICATING THE PRODUCT WAS | | | EVALUATED TO BE IN COMPLIANCE WITH THE | | | CODE AND THAT THE PRODUCT IS, FOR THE | | | PURPOSE INTENDED, AT LEAST EQUIVLENT TO | | | THAT REQUIRED BY THE CODE. | | | THE REPORT SUBMITTED IS NOT THE | | | ORIGINAL, NOT RAISED SEAL NOR ORIGINAL | | | SIGNATURE. RULE 9B-72.040(1)(D). | | | THE OTHER ISSUE IS TO PROVIDE STATE | | | APPROVED THIRD PARTY QUALITY ASSURANCE | | | PROGRAM DOCUMENTATION REQUIRED BY RULE | | | 9B-72.70. | | | THE FLORIDA COVERSHEET SUBMITTED | | | IS NOT FOR THE REPORT SUBMITTED. THERE | | | IS ONLY ONE SYSTEM THAT HAS BEEN | | | APPROVED BY THE STATE THE REST ARE STILL | | | ONLY APPLIED FOR OR PENDING. ALL THE | | | REPORTS SUBMITTED ARE FOR VARIOUS OTHER | | | PRODUCTS MANUFACTURED BY THE SAME | | | MANUFACTURER. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-17 |
Time |
07:44 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-01-17 |
Time |
07:44 |
Sent To |
PC |
|
| Notes |
| 2006-01-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010021 | | | ADD: 201 PALMETTO LN | | | CONT: STERLING COMMUNITIES | | | TEL: (561)239-9740 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW REVISION | | | ACTION: DENIED | | | | | | 1)THE ONLY "BUILDING PROVISO" GIVEN AT | | | TIME OF ISSUANCE WAS ON 3-14-05 FOR | | | 1026.5.1 EXTERIOR GUARDRAILS TO BE 42" | | | IN HEIGHT. THIS IS A REVISION REQUIRING | | | ADDITIONAL FEES. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-20 |
Time |
10:19 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-12-20 |
Time |
10:19 |
Sent To |
PC |
|
| Notes |
| 2005-12-20 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010021 | | | ADD: 201 PALMETTO LN | | | CONT: STERLING COMMUNITIES | | | TEL: (561)239-9740 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)THE ONLY "BUILDING PROVISO" GIVEN AT | | | TIME OF ISSUANCE WAS ON 3-14-05 FOR | | | 1026.5.1 EXTERIOR GUARDRAILS TO BE 42" | | | IN HEIGHT. THIS IS A REVISION REQUIRING | | | ADDITIONAL FEES. | | | | | | 2) THE PRODUCT APPROVAL SUBMITTED DOES | | | NOT HAVE FL APPROVAL. IT STATES IN THE | | | REPORT IT IS BASED ON RULE 9B-72.40 | | | METHOD 1D. THIS IS A REPORT FROM A FL | | | REGISTERED ARCHITECT OR A FLORIDA | | | PROFESSIONAL ENGINEER WHO DEVELOPED AND | | | SIGNED AND SEALED, BASED UPON TESTING OR | | | | | | COMPARATIVE ANALYSIS, OR A COMBINATION | | | THEREOF WHICH PROVIDES VERIFIABLE | | | DOCUMENTATION INDICATING THE PRODUCT WAS | | | EVALUATED TO BE IN COMPLIANCE WITH THE | | | CODE AND THAT THE PRODUCT IS, FOR THE | | | PURPOSE INTENDED, AT LEAST EQUIVLENT TO | | | THAT REQUIRED BY THE CODE. | | | THE REPORT SUBMITTED IS NOT THE | | | ORIGINAL, NOT RAISED SEAL NOR ORIGINAL | | | SIGNATURE. RULE 9B-72.040(1)(D). | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-30 |
Time |
16:33 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-03-30 |
Time |
13:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-20 |
Time |
08:22 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2005-03-20 |
Time |
08:21 |
Sent To |
PC |
|
| Notes |
| 2005-03-20 00:00:00 | SHEET A2- ELEVATION & FOOTER CHANGEJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-14 |
Time |
14:54 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2005-03-14 |
Time |
14:53 |
Sent To |
PC |
|
| Notes |
| 2005-03-14 00:00:00 | BUILDING PROVISO: | | | 1026.5.1 | | | EXTERIOR GAURDRAILS 42" |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-12 |
Time |
08:02 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-03-12 |
Time |
07:54 |
Sent To |
PC |
|
| Notes |
| 2005-03-12 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010021 | | | ADD: 201 PALMETTO LANE | | | CONT:STERLING COMMUNITIES | | | TEL: (561)239-9740 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) ONLY (1) SIGNED & SEALED SOILS REPORT | | | SUBMITTED | | | | | | 3) EXTERIOR RAILINGS TRUETHERE IS A | | | EXCEPTION IN 1026.5.1 FOR 36" HIGH | | | GAURDRAILS FOR DWELLING, HOWEVER THE | | | EXCEPTION IS FOR "WITHIN" THE DWELLING | | | UNITOTHERWISE A 42"HIGH GAURDRAIL IS | | | REQUIRED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | . | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-01 |
Time |
13:50 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-02-01 |
Time |
13:50 |
Sent To |
PC |
|
| Notes |
| 2005-02-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05010021 | | | ADD: 201 PALMETTO LANE | | | CONT: STERLING COMMUNITIES | | | TEL: (561)239-9740 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION:DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN | | | QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE | | | EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) SHEET A-1 STRUCTURAL NOTES UPDATE | | | ACI-99 TO ACI-02, ACI 530/ASCE 5/TMS | | | 402-99 TO 402-02, ACI 530/ASCE 6/ TMS | | | 602-99 TO 602-02. | | | | | | 4) SHEET A-3, A-4, FL BLD CODE | | | 2405.2.1(2) HAZARDOUS LOCATION PROVIDE | | | SAFETY GLASS FOR THIS LOCATION: | | | A) MASTER BATH TUB | | | B) MASTER BATH SHOWER | | | C) BATH# 2 | | | D) BATH# 4 | | | | | | 5) SHEET A-6 DETAIL 2, A-7 & A-8 BOTH | | | INDICATE THE USE OF A 36" GAURDRAIL, | | | 1015.2 HEIGHT. GUARDRAILS SHALL FORM A | | | VERTICAL PROTECTIVE BARRIER NOT LESS | | | THAN 42" HIGH. | | | | | | 6)FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) RADIUS HEAD FRONT DOOR | | | B) EXTERIOR RAILINGS | | | BOTH THE ABOVE MENTIONED SHALL REQUIRE: | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7)1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 8) SHEET E-1 MASTER BEDROOM HALL, NO | | | SMOKE DETECTOR INDICATED COMPLY WITH : | | | 905.2.1 APPROVED SINGLE-STATION OR | | | MULTIPLE STATION SMOKE DETECTORS SHALL | | | BE INSTALLED IN ACCORDANCE WITH NFPA 72, | | | CHAPTER 2, WITHIN EVERY DWELLING UNIT | | | WITHIN AN APARTMENT HOUSE, CONDOMINIMUM, | | | OR TOWNHOUSE AND EVERY GUEST OR SLEEPING | | | ROOM IN A MOTEL, HOTEL, OR DORMITORY & | | | SLEEPING ROOMS IN RESIDENTIAL CARE/ | | | ASSISTED LIVING OCCUPANCIES. WHERE MORE | | | THAN ONE DETECTOR IS REQUIRED TO BE | | | INSTALLED WITHIN INDIVIDUAL DWELLING | | | UNIT, THE DETECTOR SHALL BE WIRED IN | | | SUCH A MANNER THAT THE ACTUATION OF ONE | | | ALARM WILL ACTIVATE ALL THE ALARMS IN | | | THE INDIVIDUAL UNIT. | | | | | | 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2006-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-07 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-07 |
Time |
18:59 |
Sent To |
PC |
|
| Notes |
| 2006-03-07 00:00:00 | REDLINED VA FOR SM APPLIANCE, TO BE | | | 1.5KW. 220.16 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-24 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-24 |
Time |
10:45 |
Sent To |
PC |
|
| Notes |
| 2006-02-24 00:00:00 | *** UNSAT *** | | | | | | | | | ** PLEASE KNOW, ARCHITECT HAS BEEN | | | CONTACTED ON 2/24/06 AND COMMENTS WERE | | | GONE OVER IN ORDER TO ALLEAVIATE ANY | | | QUESTIONS, OR CONCERNS OVER THE | | | CORRECTIONS AND WHAT IS NEEDED. | | | | | | 1)NOTE: PLEASE SEE RISER METER MAIN NOW | | | DOES NOT INDICATE ANY OCP FOR EACH OF | | | THE TWO PANELS? | | | PLEASE SHOW.215.5,240.4,310.16 ETC | | | | | | 2)NOTE: PLEASE SEE MISSING EGRESS LTS, | | | LOGGIA, ENTRY, PLEASE KNOW, SOME SORT OF | | | FIXTURE IS REQUIRED. LS 101 7.8, NEC | | | 210.70 | | | | | | 3)NOTE: PLEASE SEE THE DEDICATED BATHS | | | ARE NOW SHOWN AS 15A, WHERE CODE | | | REQUIRES A MIN OF 20A #12. 210.11C3 | | | | | | 4)NOTE: PLEASE SEE LAUNDRY CIRCUIT NOW | | | INDICATES1200 VA FOR LOAD. PLEASE SEE | | | 220.16, WHICH REQUIRES A MIN OF 1500VA. | | | | | | PLEAS ESUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-30 |
Time |
20:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-30 |
Time |
19:51 |
Sent To |
B |
|
| Notes |
| 2006-01-30 00:00:00 | ********** UNSAT ************ | | | | | | | | | | | | 1)NOTE: PLEASE CORRELATE RISER, PLANS | | | AND PANEL SCHEDULES SUBMITTED, PLEASE | | | SEE THERE ARE NUMEROUS ITEMS WHICH DO | | | NOT MATCH. | | | | | | A) PLEASE SEE RISER SHOWS A PANEL "C", | | | HOWEVR NO PANEL SCHEDULE WAS SUBMITTED | | | FOR THIS AND THIS IS NOT SHOWN ON PLANS? | | | | | | B)PLEASE SEE WHAT APPEARS TO INDICATE A | | | 400A SERVICE NOW WITH METER MAIN, SHOWS | | | TWO-200A BRKRS, BUT ALSO SHOWS FEED THRU | | | LUGS FOR ONE?? ETC??? | | | | | | C)PLEASE SEE A POOL PANEL IS SHOWN ON | | | RISER BUT NOT ON PLANS. PLEASE SEE A | | | POOL PUMP IS SHOWN ON PANEL "B"?? VERIFY | | | OF POOL PUMP IS NOT FED FROM POOL PANEL. | | | | | | D)PLEASE SEE NOW SERVICE INDICATES TO | | | FPL HAN-HOLE, PLEASE SEE SEC'S SHALL BE | | | SIZED PER 310.15B6 (MIN) AND SHALL BE | | | SHOWN ON PLANS. | | | PLEASE SEE 1-SET OF 2/0'S ARE SHOWN | | | WHICH WAS FOR OLD 200A SERVICE. PLEASE | | | SEE A MIN OF PARALLEL OR 400MCM IS | | | REQUIRED. | | | | | | E)PLEASE SEE MIN GROUNDING ELECTRODE | | | CONDUCTOR SHALL NOW BE SIZED PER 250.66 | | | AS SEC'S AND SERVICE IS NOW CHANGED TO | | | 400A'S ETC. | | | | | | F)PLEASE SUBMIT PANEL SCHEDULES FOR ALL | | | MISSING PANELS. | | | | | | G)PLEASE SEE PANEL "A" IS SHOWN AS MLO, | | | WHEN THIS IS ALSO SHOWN AS MCB ON | | | RISER?? | | | | | | ABOVE PER 215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING SD ON PLANS | | | PER NFPA-72 11.5.1.1,OUTSIDE BEDRM 2ND | | | FLR. | | | PLEASE ALSO SEE SD IN MASTER BEDRM SHALL | | | BE LOCATED A MIN OF 3' FROM THE PEAK OF | | | A VAULTED CEILING. | | | 11.8.3.5 | | | | | | 3)NOTE: PLEASE SEE MIN CLEARENCE PER | | | 110.26 FOR CU#1 | | | | | | PLEASE REVISE AND CORRELATE THE ABOVE | | | INFORMATION FOR REVIEW. IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-27 |
Time |
08:01 |
Rev Time |
0.10 |
| Received By |
dpalmer |
Date |
2005-06-27 |
Time |
08:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
N |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-11 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-05-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-14 |
Time |
17:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-04-14 |
Time |
17:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-31 |
Time |
09:29 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-03-31 |
Time |
09:29 |
Sent To |
M |
|
| Notes |
| 2005-03-31 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE "PROVISO/REDLINED" | | | FROM PREVOUS REVIEW. | | | PLEASE CORRELATE AHU'S FROM MECH PLANS | | | WITH ELECTRICAL PANEL SCHEDULE/LOAD | | | CALCS. | | | PLEASE SEE MECH PLANS SHOWS 1-10KWA, | | | 2-7.5KW AND ELECTRICAL SHOWS 1-10KW, | | | 1-5KW AND 1-6KW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-01 |
Time |
17:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-01 |
Time |
17:39 |
Sent To |
P |
|
| Notes |
| 2005-03-01 00:00:00 | ******** PROVISO/ NOTES REDLINED **** | | | | | | | | | 1)NOTE: PLEASE CORRELATE ELECTRICAL | | | PLANS WITH MECHANICALFOR AHU HEAT | | | STRIPS. | | | PLEASE SEE MECHANICAL PLANS INDICATE : | | | ONE 10KW AND TWO 7.5KW UNITS. | | | ELECTRICAL PLANS INDICATE ONE 10KW , ONE | | | 5KW AND ONE 6KW. | | | PLEASE SEE LOAD CALCULATIONS FOR THIS | | | WILL ALSO NEED TO BE ADJUSTED. | | | IF LARGER OF THE UNITS ARE INSTALLED, A | | | 200A SERVICE IS STILL OK. | | | | | | 2)NOTE: PLEASE SEE DISCONNECT'S FOR | | | AHU'S AND CU REDLINED PER 110.26. TO BE | | | FIELD VERIFIED. | | | | | | PLEASE SUBMIT REVISED PLANS FOR NOTE #1 | | | ALONG WITH ANY OTHER POSSIBLE REVISIONS | | | BEFORE ELECTRICAL ROUGH INSPECTION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-14 |
Time |
16:05 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-01-14 |
Time |
15:01 |
Sent To |
M |
|
| Notes |
| 2005-01-14 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE; PLEASE CLARIFY SERVICE. SHOWN AS | | | 400A METER MAIN COMBO , YET IT SEEMS | | | SERVICE ONLY FEEDS A 200A DISC AND THEN | | | PANEL? PLEASE ALSO SEE SEC'S ARE ONLY | | | SHOWN AS 2/0'S FOR A 200A RATED | | | SERVICE? | | | IF INDEED A METER MAIN , PLEASE INCLUDE | | | ANY BRKRS AND /OR BRKRS IN MM. | | | IF INDEED 400A, PLEASE SEE 310.15B6 | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 210.52 FOR SOME | | | MISSING RECEPTS REQUIRED. | | | | | | 3)NOTE: PLEASE SEE GARAGE DOOR OPENERS | | | EACH SHOWN ON 2-P 30A BRKRS? | | | MISPRINT? | | | | | | 4)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN | | | COUNTERSPACE RECEPTS MISSING. | | | 210.8A6 | | | | | | 5)NOTE: PLEASE ADD SD IN HALL OUTSIDE | | | BEDRM AS DOOR BETWEEN BEDRM AND OUTER | | | HALL BLOCKS PROTECTION. | | | NFPA-72 | | | | | | 6)NOTE: PLEASE SEE IF 400A SERVICE, THEN | | | SIZE GROUNDING ELECTRODE CONDUCTOR PER | | | 250.66. 1/0 MIN | | | | | | PLEASE SEE ONE SET OF PLANS HAS MOST OF | | | THESE THINGS REDLINED FOR AREAS OF | | | CONCERN. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-03 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-03 |
Time |
08:53 |
Sent To |
E |
|
| Notes |
| 2006-03-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
09:04 |
Sent To |
E |
|
| Notes |
| 2006-02-21 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
13:10 |
Sent To |
E |
|
| Notes |
| 2006-01-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-13 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-13 |
Time |
11:06 |
Sent To |
B |
|
| Notes |
| 2006-01-13 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-12 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-12 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2006-01-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
19:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
19:06 |
Sent To |
B |
|
| Notes |
| 2005-12-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
14:48 |
Sent To |
E |
|
| Notes |
| 2005-06-21 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-09 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-09 |
Time |
11:24 |
Sent To |
E |
|
| Notes |
| 2005-05-09 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-04-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-11 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-11 |
Time |
11:48 |
Sent To |
E |
|
| Notes |
| 2005-04-11 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-25 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-25 |
Time |
08:13 |
Sent To |
B |
|
| Notes |
| 2005-03-25 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-17 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-17 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
| 2005-03-17 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-28 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-28 |
Time |
10:42 |
Sent To |
E |
|
| Notes |
| 2005-02-28 00:00:00 | TO "DPALMER"DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-13 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-13 |
Time |
15:26 |
Sent To |
E |
|
| Notes |
| 2005-01-13 00:00:00 | TO 'E" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
10:13 |
Sent To |
Z |
|
| Notes |
| 2005-01-06 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-04-07 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-09 |
Time |
18:28 |
Sent To |
B |
|
| Notes |
| 2005-03-09 00:00:00 | 1) MEED RETURN AIR IN DINNING ROOM | | | 2)REFER TO SECTION 610.1 ABC.3.5.2 | | | FLORIDA BUILDING CODE CHAPTER 13.NOTICE | | | TO HOMEOWNER.REFERRING TO AIRHANDLERS 2 | | | & 3 | | | 3) REFER TO SECTION 610.1.ABC.3.5.2 #1 | | | THE SERVICE PANEL OF THE EQUIPMENT IS | | | LOCATED WITHIN 6FT.OF AN ATTIC ACCESS | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-08 |
Time |
08:16 |
Rev Time |
2.00 |
| Received By |
prafter |
Date |
2005-01-20 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2005-01-20 00:00:00 | 1. RETURN AIR DUCT FOR A.H.U. #1 | | | SHOULD BE EQUEAL TO SUPPLY AIR DUCT | | | CONBINE , 314 SQ. IN. TO RETURN AIR DUCT | | | OF 201 SQ. IN. OF AREA. | | | RETURN AIR GRILL IS SOME WHAT SMALL | | | FOR THE SIZE OF A.H.U. . 2003 FBC/M | | | 601.4 . | | | 2. RETURN AIR DUCT OUT OF SECOND FLOOR | | | BEDROOMS SHOULD BE ONE AND HALF LARGER | | | THAN SUPPLY AIR DUCT.2003 FBC/M | | | EXCEPTION #1 . | | | 3.HALL WAY RETURN AIR GRILL MUST | | | COMPLY WITH 2003 FBC/M 601.4 EXCEPTION | | | #2 FOR SIZE. | | | 4. SUPPLY AIR DUCT LEADING TO BEDROOM | | | #3 AND #4 SHOULD BE LARGER THAN | | | REFLECTED ON PLAN. (4") | | | 5. CONDENSATE FROM A.H.U. MUST CONFORM | | | WITH 2003 FBC/M 307.2.3 .FOR AUX. DRAIN | | | PANS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-05 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-03-05 |
Time |
08:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-19 |
Time |
11:15 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-19 |
Time |
11:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-13 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-13 |
Time |
12:40 |
Sent To |
I |
|
| Notes |
|
|