Plan Review Details - Permit 04121980
Plan Review Stops For Permit 04121980
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2005-12-29 Cont ID  
Sent By jgomez Date 2005-12-29 Time 18:49 Rev Time 0.50
Received By jgomez Date 2005-12-29 Time 18:49 Sent To PC
Notes
2005-12-29 00:00:00BUILDING REVISION CHECKLIST:
 1- KEY PLAN STILL DOESN'T MATCH FLOOR
 PLAN. REVISE AS REQUIRED. SEE FLOOR
 PLAN.
  
 2- PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED INSTALLATION
 SCHEDULE SAMPLE THAT SUMMARIZES
 INFORMATION REQUIRED FOR PLAN REVIEW.
 PROVIDE ALL INFORMATION TO EXPEDITE
 REVIEW. IT ALSO FACILITATES INSPECTIONS.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2005-11-14 Cont ID  
Sent By jgomez Date 2005-11-14 Time 17:39 Rev Time 0.50
Received By jgomez Date 2005-11-14 Time 17:56 Sent To PC
Notes
2005-11-14 00:00:00BUILDING SUBMITTAL CHECKLIST:
 1- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR WINDOW MULLIONS THAT MEET
 THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT. WINDOW MULLION PRODUCT
 APPROVAL SUBMITTED DON'T RESIST THE
 DESIGN PRESSURES CALCULATED IN PLANS.
  
 2- STORM SHUTTERS INFORMATION WAS
 SUBMITTED ON 8-12-05. IT WAS REJECTED
 BECAUSE IT WAS A REVISION AND
 INFORMATION WAS NOT COMPLETE. SEE COPY
 OF COMMENTS DATED 9-20-05. RESUBMIT AND
 PAY REVISION FEES AS REQUIRED.
  
 NOTE:
 REVISED SHEET A-6 AND STEEL HEADER
 DETAIL ARE APPROVED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-09-20 Cont ID  
Sent By jgomez Date 2005-09-20 Time 16:52 Rev Time 0.33
Received By jgomez Date 2005-09-20 Time 16:52 Sent To PC
Notes
2005-09-20 00:00:00SUBMITTAL BUILDING REVIEW CHECKLIST:
 1- SHUTTERS INFORMATION SUBMITTED IS
 DIFFERENT FROM INFORMATION SUBMITTED AT
 TIME OF PRINTING PERMIT. THIS IS A
 REVISION AND REVISION FEES APPLY.
  
 2- PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS INCLUDING INSTALLATION
 SCHEDULE (SEE ATTACHED SAMPLE FOR REQ'D
 MIN. INFORMATION).ALSO, INDICATE ON
 DRAWINGS SPECIFIC MOUNTING CONDITIONS
 AND ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE DESIGN PRESSURES, EDGE
 DISTANCE, PANEL SPAN, CONNECTION TYPE
 AND STRUCTURE TO BE ATTACHED TO
 (CONCRETE OR CONCRETE BLOCK).
  
 3- PROVIDE INFORMATION REQUESTED ON
 PROVISO DATED 8-2-05. SEE ATTACHED COPY.
  
 JULIO GOMEZ
 PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-02 Cont ID  
Sent By jgomez Date 2005-08-02 Time 13:50 Rev Time 2.50
Received By jgomez Date 2005-08-02 Time 13:50 Sent To PC
Notes
2005-08-02 00:00:00BUILDING REVIEW PROVISO:
 1- DESIGNER OF RECORD TO SPECIFY ON
 PLANS ROOF TILE FASTENING AS REQUIRED BY
 SEC. 104.2.1.1 CITY AMENDMENTS TO FBC.
 2- ANCHOR SCHEDULE: A)REVISE FASTENERS
 FOR THD210 CONNECTOR. SEE TECHNICAL
 BULLETIN.
 B) CONNECTOR G: PROVIDE TESTING AND
 ENGINEERING CALCS FOR NUMBER/TYPE OF
 NAILS THAT DIFFER TO THOSE TESTED AND
 PUBLISHED BY THE MANUFACTURER. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 **NAIL CALCS SHOWN ON SHEET A-6 ARE FOR
 10D NAILS ONLY. THEY DON'T APPLY TO 16D.
 WHAT CRITERIA IS USED WHEN REDUCING THE
 NUMBER OF NAILS. EG: SEE PAGE 17 OF USP
 BOOK FOR LOADS REDUCTION (SIMPSON HAS AN
 EQUATION ON PAGE 137 OF 2005 CATALOGUE).
 3- SPECIFY SIZE AND ANCHORS FOR WINDOW
 MULLIONS AT LIVING ROOM FIXED WINDOWS TO
 VERIFY DESIGN PRESSURES COMPLIANCE. SEE
 PRODUCT APPROVAL FOR SIZE LIMITATIONS.
 4-STORM SHUTTERS: REVISE KEY PLAN AND
 INSTALLATION SCHEDULE TO MATCH FLOOR
 PLAN AND RE-SUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-05-12 Cont ID  
Sent By jgomez Date 2005-05-12 Time 13:36 Rev Time 2.00
Received By jgomez Date 2005-05-12 Time 12:23 Sent To Z
Notes
2005-05-12 00:00:00BUILDING REVIEW CHECKLIST:
 1- DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENING AS REQUIRED BY SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 2-UPDATE TRUSS ANCHOR SCHEDULE. SEE
 LATEST CATALOGUE THAT WAS REVISED TO
 COMPLY WITH SECTION 1609.4.3 FBC 2001.
 OTHERWISE, PROVIDE COMPLETE ENGINEERING
 CALCS FOR FASTENER TYPE AND NUMBER THAT
 DIFFER FROM THOSE TESTED AND PUBLISHED
 BY THE MANUFACTURER. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 3- ELEVATIONS CALL FOR FLAT TILE.
 PRODUCT APPROVAL SUBMITTED WAS FOR "S"
 TILE. REVISE AS REQUIRED.
  
 4- INSURANCE WILL EXPIRE ON 5-27-05.
 PLEASE, UPDATE INFORMATION AT TIME OF
 SUBMITTAL TO AVOID ANY DELAYS.
  
 5- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR FRENCH DOORS WITH
 SIDELITES. PRODUCT SUBMITTED ARE FOR
 6'-8" DOORS. NEED 8'-0" HEIGHT DOORS.
  
 6- OWES $949.68 FOR UPDATE VALUE AND
 RADON FEES. AND, FOR ADDED A/C AREA.
  
 7- DETAIL 2/A-9:PROVIDE SPECS FOR "U"
 STRAP TO BE USED. SEC. 104.2.1 CITY
 AMENDMENTS TO FBC 2001.
  
 8- DESIGN PARAMETERS ON SHEET A-3:
 SPECIFY/CLARIFY WHERE IS THE BASIC
 VELOCITY PRESSURE TAKEN FROM?. THERE ARE
 NOT TABLES ON CHAPTER 16 FBC 2001
 SHOWING THIS VALUES.
  
 9- LEFT SIDE ELEVATION DON'T MATCH FLOOR
 PLAN. NEED TO SHOW MASTER BEDROOM
 SITTING AREA. REVISE AS REQUIRED.
  
 10- REVISE FRONT ELEVATION TO SHOW STEEL
 DOOR AS PER PRODUCT APPROVAL SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-27 Cont ID  
Sent By jgomez Date 2005-01-27 Time 09:13 Rev Time 0.00
Received By jgomez Date 2005-05-12 Time 11:27 Sent To PC
Notes
2005-01-27 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE COMPLETE BATHROOM WITH DOOR
 THAT ALLOWS 29" MIN. CLEAR OPENING.
 SECTION 11-11 FBC 2001.
  
 2- SPECIFY ROOF TILE FASTENING. SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 3- UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE
 COMPLETE ENGINEERING CALCULATIONS FOR
 TYPE AND NUMBER OF FASTENERS THAT DIFFER
 FROM THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER TO COMPLY WITH SECTION
 1609.4.3 FBC 2001.
  
 4- A) TITLE BLOCK NEEDS NAME OF
 ARCHITECT SEALING THE PLANS. CHAPTER
 61G1-16004 F.A.C.
 B) STATE REGISTRATION NUMBER IS
 INCORRECT. REVISE AS REQUIRED.
  
 5- PROVIDE COMPLETE DETAIL/SPECS FOR
 CEILING INSTALLATION AT ENTRY AND REAR
 PORCHES. SEE ASTM C926 AND ASTM C1063.
 SECTION 2504.2 FBC 2001.
  
 6- ENERGY CALCS NEED TO BE SIGNED AND
 DATED BY THE OWNER/AGENT.
  
 7- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) ENTRY DOORS.
 B) FRENCH DOORS. SEE SIZES ON PLANS.
 C) CONCRETE LINTELS: NEED DADE COUNTY
 NOA THAT MATCHES ONE SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL.
 D) FIXED WINDOWS THAT MEET THE DESIGN
 PRESSURES CALCULATED ON PLANS. SEE PLANS
 FOR SIZES AND DESIGN PRESSURES.
 E) ARABESQUE WINDOW. SEE PLANS.
  
 8- A) PROVIDE COMPLETE UL LISTING AND
 SPECS FOR FIREPLACE. SEC. 2806 FBC
 2001.
 B) PROVIDE APPROVED BBQ SPECS AS REQ'D
 BY SECTION 2808 FBC 2001.
  
 9- STORM SHUTTERS: A) KEY PLAN DOESN'T
 MATCH PLANS.
 B) REVISE MIN. PANEL SIZE. SEE
 ENGINEERED DRAWINGS FOR LIMITATIONS.
 C) REVISE INTERIOR AND END ZONES. SEE
 PLANS FOR LOCATION OF OPENINGS.
 D) REVISE DESIGN PRESSURES. SEE PLANS.
  
 10- PROVIDE COMPLETE FRAMING DETAILS FOR
 ARABESQUE WINDOW. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 11- OWES $866.23 FOR UPDATED VALUATION.
  
 12- REVISE FOUNDATION NOTE #2 ON SHEET
 A-2. SEE CHAPTER 19 FBC 2001 FOR PROEPR
 ACI REFERENCE TO BE USED.
  
 13- REVISE CONNECTORS SHOWN ON DETAIL
 2/A-9. "SEMCO" IS OUT OF BUSINESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-03-20 Cont ID  
Sent By btrobaug Date 2006-03-20 Time 07:03 Rev Time 0.50
Received By btrobaug Date 2006-03-20 Time 06:31 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-22 Cont ID  
Sent By btrobaug Date 2005-12-22 Time 14:10 Rev Time 0.50
Received By btrobaug Date 2005-12-22 Time 13:33 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-11 Cont ID  
Sent By btrobaug Date 2005-07-11 Time 10:16 Rev Time 0.50
Received By btrobaug Date 2005-07-11 Time 07:25 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-04-26 Cont ID  
Sent By btrobaug Date 2005-04-26 Time 12:05 Rev Time 0.50
Received By btrobaug Date 2005-04-26 Time 10:43 Sent To P
Notes
2005-04-26 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} INDICATE THE LOCATION OF PANEL "B".
  
 2} INDICATE LOCATION OF OVERCURRENT
 PROTECTION FOR PANELS "A" & "B".
  
 3} THE OCP FOR CIRCUITS 12,13 PANEL "A",
 12,13,14,15 PANEL "B" IS TOO LARGE FOR
 THE CONDUCTORS PER 210.16.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-07 Cont ID  
Sent By btrobaug Date 2005-01-07 Time 13:54 Rev Time 0.50
Received By btrobaug Date 2005-01-07 Time 13:53 Sent To M
Notes
2005-01-07 00:00:00 
  
 .PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE OVERCURRENT PROTECTION FOR AHU
 #2 AT 60 AMPS IS TOO LARGE TO PROTECT A
 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30
 AMP OCP). ALSO 60 AMP OCP SHOWN INTHE
 MAIN PANEL SEEM TOOLARGE FOR THE
 CONDENSING UNIT. SEE ARTICLE 440.22
 NEC.
  
 2} THERE ARE NO PROVISIONS IN THE
 CALCULATIONS FOR POOL EQUIPMENT, BUT
 THERE IS EQUIPMENT SHOWN ON THE PLAN.
  
 3} IF NOTE #15 IS ADHERED TO, THOSE
 CIRCUITS WOULD HAVE TO BE PROTECTED BY
 AN AFCI BECAUSE THE DETECTORS ARE
 LOCATED IN BEDROOMS. 210.12.
  
 4} THE GFI'S SHOWN IN THE DINING ROOM
 AND BREAKFAST NOOK, WHILE NOT REQUIRED
 ALTHOUGH PERMISSIBLE, MUST BE INSTALLED
 IF LEFT ON THE PLAN.
  
 5} A RECEPTACLE NEEDS TO BE ADDED TO
 THE MASTER BEDROOM TO COMPLY WITH
 210.52(A).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-03-17 Cont ID  
Sent By adarroug Date 2006-03-17 Time 14:59 Rev Time 0.00
Received By adarroug Date 2006-03-17 Time 14:59 Sent To E
Notes
2006-03-17 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-12-16 Cont ID  
Sent By adarroug Date 2005-12-16 Time 16:43 Rev Time 0.00
Received By adarroug Date 2005-12-16 Time 16:43 Sent To E
Notes
2005-12-16 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-10-07 Cont ID  
Sent By adarroug Date 2005-10-07 Time 16:35 Rev Time 0.00
Received By adarroug Date 2005-10-07 Time 16:34 Sent To B
Notes
2005-10-07 00:00:00TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-16 Cont ID  
Sent By adarroug Date 2005-08-16 Time 08:24 Rev Time 0.00
Received By adarroug Date 2005-08-16 Time 08:23 Sent To B
Notes
2005-08-16 00:00:00TO "JGOMEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-08 Cont ID  
Sent By adarroug Date 2005-07-08 Time 16:23 Rev Time 0.00
Received By adarroug Date 2005-07-08 Time 16:23 Sent To E
Notes
2005-07-08 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-25 Cont ID  
Sent By adarroug Date 2005-04-25 Time 10:32 Rev Time 0.00
Received By adarroug Date 2005-04-25 Time 10:32 Sent To B
Notes
2005-04-25 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 07:39 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 07:38 Sent To E
Notes
2005-01-06 00:00:00TO "SFD" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2005-01-03 Time 12:08 Rev Time 0.00
Received By mjacobs Date 2005-01-03 Time 12:08 Sent To Z
Notes
2005-01-03 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-11 Cont ID  
Sent By btrobaug Date 2005-01-07 Time 13:56 Rev Time 0.00
Received By prafter Date 2005-01-11 Time 13:36 Sent To B
Notes
2005-01-11 00:00:00NO A/C PLANS.
 PAT RAFTER 561/805/6725 OR 8056719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-08-01 Cont ID  
Sent By jleech Date 2005-08-01 Time 07:23 Rev Time 0.33
Received By jleech Date 2005-08-01 Time 07:22 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-05-09 Cont ID  
Sent By kstevens Date 2005-05-09 Time 06:41 Rev Time 0.50
Received By kstevens Date 2005-05-09 Time 06:41 Sent To B
Notes
2005-05-09 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SHT A-7 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS:
 A. THE FUTURE SINK ON THE PATIO DOES
 NOT SHOW THE STUB OUT ABOVE THE SLAB,
 SHOULD SHOW A RISER. ALSO THE SINK DOES
 NOT SHOW A VENT. SECTIONS 104.2.1. &
 901.2.1.
 B. DOUBLE SANITARY TEE PATTERNS SHALL
 NOT RECIEVE THE DISCHARGE OF APPLIANCES
 WITH PUMPING ACTION DISCHARGE. THE WASH
 MACHINE SHALL CONNECT DOWNSTREAM OF THE
 LAUNDRY SINK. SECTION 706.3
 C. THE CLEANOUT ON THE WASH MACHINE
 STACK SHALL BE A MINIMUM OF 4' ABOVE THE
 FLOOR FOR ACCESS. SECTION 708.10.
 D. SEE RED LINE EXAMPLES OF CORRECT
 PIPING/VENT/CLEANOUT ON A-7 SHEET.
 2) AS REQUIRED BY 104.3.1.1 OF THE CODE,
 TWO OR MORE COPIES OF DRAWINGS ARE
 REQUIRED. LOOSE SHEETS ARE NOT APPROVED,
 PLEASE STAPLE SETS OF PLANS TOGETHER.
 SECTIONS 104.2.1 & 104.2.1.3.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-10 Cont ID  
Sent By jleech Date 2005-01-10 Time 18:58 Rev Time 0.33
Received By jleech Date 2005-01-10 Time 18:58 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-05-13 Cont ID  
Sent By mmclean Date 2005-05-13 Time 13:30 Rev Time 0.00
Received By mmclean Date 2005-05-13 Time 13:29 Sent To  
Notes
2005-05-13 00:00:00APPROVED RE-SUB. MUST PULL SEPERATE
 PERMIT FOR POOL/SPA/DECK/SCREEN
 ENCLOSURE.

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By mmclean Date 2005-01-05 Time 17:45 Rev Time 0.00
Received By mmclean Date 2005-01-05 Time 17:45 Sent To I
Notes
2005-01-05 00:00:00MUST PULL SEPERATE PERMIT FOR POOL/DECK