| Plan Review Stops For Permit 04121956 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-30 |
Time |
11:21 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2005-12-30 |
Time |
11:21 |
Sent To |
PC |
|
| Notes |
| 2005-12-30 00:00:00 | CASEMENT WINDOWS PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-22 |
Time |
17:20 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2005-09-22 |
Time |
17:20 |
Sent To |
E |
|
| Notes |
| 2005-09-23 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | | | | | 1- PRODUCT APPROVAL SUBMITTED FOR | | | CASEMENT WINDOWS IS FOR IMPACT WINDOWS. | | | NEED PRODUCT APPROVAL FOR NON-IMPACT | | | WINDOWS. | | | | | | ***NOTE: OTHERPART OF SUBMITTAL IS OK. | | | | | | | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-09 |
Time |
12:39 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-08-09 |
Time |
12:39 |
Sent To |
PC |
|
| Notes |
| 2005-08-09 00:00:00 | BUILDING REVIEW PROVISO: | | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | | 2- DESIGNER OF RECORD (NOT THE BUILDER) | | | TO SPECIFY ROOF TILE FASTENING. SEC. | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | 3- A) REVISE FASTENERS SPECIFIED FOR | | | THD210. SEE TECHNICAL BULLETIN & PROVIDE | | | CORRESPONDING PRODUCT APPROVAL. | | | 4- CLARIFY IF USING CASEMENT WINDOW WITH | | | IMPACT GLASS OR NOT & PROVIDE | | | CORRESPONDING PRODUCT APPROVAL. | | | 5- A) PROVIDE FLORIDA/LOCAL PRODUCT | | | APPROVAL FOR 5"X5"X1/4" STRUCTURAL | | | MULLION SPECIFIED ON ARCHITECT'S DETAIL. | | | B) PROVIDE FLORIDA/LOCAL PRODUCT | | | APPROVAL FOR OTHER MULLIONS TO BE USED. | | | AND SPECIFY MULLION SIZE AND ANCHORS FOR | | | FIXED WINDOWS IN LIVING ROOM AREA. | | | 6- PROVIDE COMPLETE APPROVED LISTING AND | | | SPECS FOR BBQ AND EXHAUST HOOD FOR PORCH | | | INSTALLATION.SECTION 2808 FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-07 |
Time |
16:47 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-06-07 |
Time |
16:47 |
Sent To |
P |
|
| Notes |
| 2005-06-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENING AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 2- USP CONNECTOR THD210 OR THD210-2 IS A | | | WOOD TO WOOD CONNECTOR. NEED TO SPECIFY | | | MASONRY CONNECTOR. SEE CATALOGUE FOR | | | PROPER MASONRY CONNECTOR. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 3- STORM SHUTTERS: NEED TO REVISE THE | | | MIN. PANEL SPAN ACCORDING TO THE | | | ENGINEERED DRAWINGS MOUNTING CONDITION | | | SELECTED. SEE DRAWINGS AND REVISE AS | | | REQUIRED. | | | | | | 4- DADE COUNTY NOA SUBMITTED FOR | | | CASEMENT WINDOWS DON'T MATCH NOA'S | | | SUBMITTED FOR THE FLORIDA PRODUCT | | | APPROVAL. RESUBMIT CORRECT NOA. | | | | | | 5- WINDOW/DOOR MULLION PRODUCT APPROVAL | | | SUBMITTED DOESN'T RESIST DESIGN | | | PRESSURES CALCULATED ON DRAWINGS. | | | PROVIDE PRODUCT APPROVAL FOR MULLIONS | | | THAT MEET SUCH PRESSURES. CLEARLY | | | SPECIFY SIZE AND ANCHOR TYPE. SEC. | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 6- BBQ INFORMATION SUBMITTED TO BE | | | REVIEWED BY BUILDING OFFICIALFOR | | | APPROVAL. | | | NOTE: THERE ARE SOME BBQ'S THAT ARE | | | SPECIFICALLY DESIGNED TO BE INSTALLED IN | | | THE PORCH OR LANAI. THEY REQUIRE THE | | | EXHAUST HOOD. BUILDING OFFICIAL MAY | | | REQUIRE ADDITIONAL INFORMATION OR | | | TESTING TO SUPPORT ALFRESCO GRILLS'S | | | LETTER STATING THAT HOOD IS NOT REQ'D. | | | | | | 7- SHEET A-6: REVISE TYPO ON ROOF | | | DIAPHRAGM. IT SHOULD READ 4' NOT 4". | | | | | | 8- SHEET A-3: CLARIFY WHERE IS THE BASIC | | | VELOCITY PRESSURE TAKEN FROM? THIS WAS | | | PART OF THE STANDARD BUILDING CODE NOT | | | THE FLORIDA BUILDING CODE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-27 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-01-27 |
Time |
10:52 |
Sent To |
PC |
|
| Notes |
| 2005-01-27 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE BATHROOM WITH DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2- SPECIFY ROOF TILE FASTENING. SEC. | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- UPDATE TRUSS ANCHOR SCHEDULE. | | | PROVIDE | | | COMPLETE ENGINEERING CALCS FOR TYPE AND | | | NUMBER OF FASTENERS THAT DIFFER FROM | | | THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4- A) PLANS NEED THE NAME OF ARCHITECT | | | SEALING THE PLANS. CHAPTER 61G1-16004. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE DETAIL/SPECS FOR | | | CEILING INSTALLATION AT ENTRY AND REAR | | | PORCHES. SPECIFY FASTENERS AND SPACING. | | | SEE ASTM C926 AND ASTM C1063. | | | SECTION 2504.2 FBC 2001. | | | | | | 6- OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS. | | | | | | 7- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS. SEE SIZE ON PLANS. | | | B) FRENCH DOORS. SEE SIZES ON PLANS. | | | C) CONCRETE LINTELS: PROVIDE DADE | | | COUNTY | | | NOA THAT MATCHES ONE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE DESIGN | | | PRESSURES SHOWN ON PLANS. SEE PLANS FOR | | | SIZES AND DESIGN PRESSURES. | | | E) ARABESQUE WINDOW. SEE PLANS. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. SEC. 2806 FBC | | | 2001. | | | B) PROVIDE COMPLETE APPROVED BBQ SPECS. | | | SECTION 2808 FBC 2001. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. REVISE AS REQUIRED. | | | B) REVISE MIN. PANEL SIZE. SEE | | | LIMITATIONS ON ENGINEERED DRAWINGS. | | | C) REVISE END AND INTERIOR ZONES. SEE | | | PLANS FOR LOCATION. | | | D) REVISE OPENINGS DESIGN PRESSURES. | | | SEE | | | PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS | | | FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- OWES $866.23 FOR UPDATED VALUATION. | | | | | | 12- REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE CONNECTORS SPECIFIED ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-10 |
Time |
08:02 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-10 |
Time |
07:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
20:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
19:52 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | REV'S. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-09-23 |
Time |
17:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-09-23 |
Time |
16:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-20 |
Time |
16:24 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-20 |
Time |
16:24 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-02 |
Time |
07:48 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-02 |
Time |
07:23 |
Sent To |
B |
|
| Notes |
| 2005-06-02 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | | | | 1} INDICATE THE LOCATION OF PANEL | | | "B"&"C". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 12,13 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
12:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
12:38 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THEMASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
15:49 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-18 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-18 |
Time |
14:11 |
Sent To |
E |
|
| Notes |
| 2006-01-18 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-30 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-30 |
Time |
08:41 |
Sent To |
B |
|
| Notes |
| 2005-08-30 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-18 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-18 |
Time |
12:04 |
Sent To |
E |
|
| Notes |
| 2005-07-18 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:20 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:10 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
10:59 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
16:01 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
16:01 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-26 |
Time |
07:13 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-26 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-07 |
Time |
18:14 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-06-07 |
Time |
18:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
17:21 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
17:21 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:56 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|