Plan Review Details - Permit 04121956
Plan Review Stops For Permit 04121956
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-12-30 Cont ID  
Sent By jgomez Date 2005-12-30 Time 11:21 Rev Time 0.33
Received By jgomez Date 2005-12-30 Time 11:21 Sent To PC
Notes
2005-12-30 00:00:00CASEMENT WINDOWS PRODUCT APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-09-23 Cont ID  
Sent By jgomez Date 2005-09-22 Time 17:20 Rev Time 1.00
Received By jgomez Date 2005-09-22 Time 17:20 Sent To E
Notes
2005-09-23 00:00:00BUILDING SUBMITTAL CHECKLIST:
  
 1- PRODUCT APPROVAL SUBMITTED FOR
 CASEMENT WINDOWS IS FOR IMPACT WINDOWS.
 NEED PRODUCT APPROVAL FOR NON-IMPACT
 WINDOWS.
  
 ***NOTE: OTHERPART OF SUBMITTAL IS OK.
  
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-08-09 Cont ID  
Sent By jgomez Date 2005-08-09 Time 12:39 Rev Time 2.00
Received By jgomez Date 2005-08-09 Time 12:39 Sent To PC
Notes
2005-08-09 00:00:00BUILDING REVIEW PROVISO:
 1- SHUTTERS UNDER A SEPARATE PERMIT.
 2- DESIGNER OF RECORD (NOT THE BUILDER)
 TO SPECIFY ROOF TILE FASTENING. SEC.
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
 3- A) REVISE FASTENERS SPECIFIED FOR
 THD210. SEE TECHNICAL BULLETIN & PROVIDE
 CORRESPONDING PRODUCT APPROVAL.
 4- CLARIFY IF USING CASEMENT WINDOW WITH
 IMPACT GLASS OR NOT & PROVIDE
 CORRESPONDING PRODUCT APPROVAL.
 5- A) PROVIDE FLORIDA/LOCAL PRODUCT
 APPROVAL FOR 5"X5"X1/4" STRUCTURAL
 MULLION SPECIFIED ON ARCHITECT'S DETAIL.
 B) PROVIDE FLORIDA/LOCAL PRODUCT
 APPROVAL FOR OTHER MULLIONS TO BE USED.
 AND SPECIFY MULLION SIZE AND ANCHORS FOR
 FIXED WINDOWS IN LIVING ROOM AREA.
 6- PROVIDE COMPLETE APPROVED LISTING AND
 SPECS FOR BBQ AND EXHAUST HOOD FOR PORCH
 INSTALLATION.SECTION 2808 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-07 Cont ID  
Sent By jgomez Date 2005-06-07 Time 16:47 Rev Time 2.00
Received By jgomez Date 2005-06-07 Time 16:47 Sent To P
Notes
2005-06-07 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENING AS REQUIRED BY SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 2- USP CONNECTOR THD210 OR THD210-2 IS A
 WOOD TO WOOD CONNECTOR. NEED TO SPECIFY
 MASONRY CONNECTOR. SEE CATALOGUE FOR
 PROPER MASONRY CONNECTOR. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 3- STORM SHUTTERS: NEED TO REVISE THE
 MIN. PANEL SPAN ACCORDING TO THE
 ENGINEERED DRAWINGS MOUNTING CONDITION
 SELECTED. SEE DRAWINGS AND REVISE AS
 REQUIRED.
  
 4- DADE COUNTY NOA SUBMITTED FOR
 CASEMENT WINDOWS DON'T MATCH NOA'S
 SUBMITTED FOR THE FLORIDA PRODUCT
 APPROVAL. RESUBMIT CORRECT NOA.
  
 5- WINDOW/DOOR MULLION PRODUCT APPROVAL
 SUBMITTED DOESN'T RESIST DESIGN
 PRESSURES CALCULATED ON DRAWINGS.
 PROVIDE PRODUCT APPROVAL FOR MULLIONS
 THAT MEET SUCH PRESSURES. CLEARLY
 SPECIFY SIZE AND ANCHOR TYPE. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
  
 6- BBQ INFORMATION SUBMITTED TO BE
 REVIEWED BY BUILDING OFFICIALFOR
 APPROVAL.
 NOTE: THERE ARE SOME BBQ'S THAT ARE
 SPECIFICALLY DESIGNED TO BE INSTALLED IN
 THE PORCH OR LANAI. THEY REQUIRE THE
 EXHAUST HOOD. BUILDING OFFICIAL MAY
 REQUIRE ADDITIONAL INFORMATION OR
 TESTING TO SUPPORT ALFRESCO GRILLS'S
 LETTER STATING THAT HOOD IS NOT REQ'D.
  
 7- SHEET A-6: REVISE TYPO ON ROOF
 DIAPHRAGM. IT SHOULD READ 4' NOT 4".
  
 8- SHEET A-3: CLARIFY WHERE IS THE BASIC
 VELOCITY PRESSURE TAKEN FROM? THIS WAS
 PART OF THE STANDARD BUILDING CODE NOT
 THE FLORIDA BUILDING CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-27 Cont ID  
Sent By jgomez Date 2005-01-27 Time 11:11 Rev Time 0.00
Received By jgomez Date 2005-01-27 Time 10:52 Sent To PC
Notes
2005-01-27 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE COMPLETE BATHROOM WITH DOOR
 THAT ALLOWS 29" MIN. CLEAR OPENING.
 SECTION 11-11 FBC 2001.
  
 2- SPECIFY ROOF TILE FASTENING. SEC.
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 3- UPDATE TRUSS ANCHOR SCHEDULE.
 PROVIDE
 COMPLETE ENGINEERING CALCS FOR TYPE AND
 NUMBER OF FASTENERS THAT DIFFER FROM
 THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER TO COMPLY WITH SECTION
 1609.4.3 FBC 2001.
  
 4- A) PLANS NEED THE NAME OF ARCHITECT
 SEALING THE PLANS. CHAPTER 61G1-16004.
 B) STATE REGISTRATION NUMBER IS
 INCORRECT. REVISE AS REQUIRED.
  
 5- PROVIDE COMPLETE DETAIL/SPECS FOR
 CEILING INSTALLATION AT ENTRY AND REAR
 PORCHES. SPECIFY FASTENERS AND SPACING.
 SEE ASTM C926 AND ASTM C1063.
 SECTION 2504.2 FBC 2001.
  
 6- OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS.
  
 7- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) ENTRY DOORS. SEE SIZE ON PLANS.
 B) FRENCH DOORS. SEE SIZES ON PLANS.
 C) CONCRETE LINTELS: PROVIDE DADE
 COUNTY
 NOA THAT MATCHES ONE SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL.
 D) FIXED WINDOWS THAT MEET THE DESIGN
 PRESSURES SHOWN ON PLANS. SEE PLANS FOR
 SIZES AND DESIGN PRESSURES.
 E) ARABESQUE WINDOW. SEE PLANS.
  
 8- A) PROVIDE COMPLETE UL LISTING AND
 SPECS FOR FIREPLACE. SEC. 2806 FBC
 2001.
 B) PROVIDE COMPLETE APPROVED BBQ SPECS.
 SECTION 2808 FBC 2001.
  
 9- STORM SHUTTERS: A) KEY PLAN DOESN'T
 MATCH PLANS. REVISE AS REQUIRED.
 B) REVISE MIN. PANEL SIZE. SEE
 LIMITATIONS ON ENGINEERED DRAWINGS.
 C) REVISE END AND INTERIOR ZONES. SEE
 PLANS FOR LOCATION.
 D) REVISE OPENINGS DESIGN PRESSURES.
 SEE
 PLANS.
  
 10- PROVIDE COMPLETE FRAMING DETAILS
 FOR
 ARABESQUE WINDOW. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 11- OWES $866.23 FOR UPDATED VALUATION.
  
 12- REVISE FOUNDATION NOTE #2 ON SHEET
 A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER
 ACI REFERENCE.
  
 13- REVISE CONNECTORS SPECIFIED ON
 DETAIL 2/A-9. "SEMCO" IS OUT OF
 BUSINESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-03-10 Cont ID  
Sent By btrobaug Date 2006-03-10 Time 08:02 Rev Time 0.50
Received By btrobaug Date 2006-03-10 Time 07:58 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-01-20 Cont ID  
Sent By dpalmer Date 2006-01-20 Time 20:04 Rev Time 0.00
Received By dpalmer Date 2006-01-20 Time 19:52 Sent To  
Notes
2006-01-20 00:00:00REV'S.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-09-23 Cont ID  
Sent By btrobaug Date 2005-09-23 Time 17:51 Rev Time 0.50
Received By btrobaug Date 2005-09-23 Time 16:59 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-20 Cont ID  
Sent By btrobaug Date 2005-07-20 Time 16:24 Rev Time 0.50
Received By btrobaug Date 2005-07-20 Time 16:24 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-02 Cont ID  
Sent By btrobaug Date 2005-06-02 Time 07:48 Rev Time 0.50
Received By btrobaug Date 2005-06-02 Time 07:23 Sent To B
Notes
2005-06-02 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
  
 1} INDICATE THE LOCATION OF PANEL
 "B"&"C".
  
 2} INDICATE LOCATION OF OVERCURRENT
 PROTECTION FOR PANELS "A" & "B".
  
 3} THE OCP FOR CIRCUITS 12,13 PANEL "A",
 12,13,14,15 PANEL "B" IS TOO LARGE FOR
 THE CONDUCTORS PER 210.16.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-07 Cont ID  
Sent By btrobaug Date 2005-01-07 Time 12:39 Rev Time 0.50
Received By btrobaug Date 2005-01-07 Time 12:38 Sent To M
Notes
2005-01-07 00:00:00 
  
 .PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE OVERCURRENT PROTECTION FOR AHU
 #2 AT 60 AMPS IS TOO LARGE TO PROTECT A
 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30
 AMP OCP). ALSO 60 AMP OCP SHOWN INTHE
 MAIN PANEL SEEM TOOLARGE FOR THE
 CONDENSING UNIT. SEE ARTICLE 440.22
 NEC.
  
 2} THERE ARE NO PROVISIONS IN THE
 CALCULATIONS FOR POOL EQUIPMENT, BUT
 THERE IS EQUIPMENT SHOWN ON THE PLAN.
  
 3} IF NOTE #15 IS ADHERED TO, THOSE
 CIRCUITS WOULD HAVE TO BE PROTECTED BY
 AN AFCI BECAUSE THE DETECTORS ARE
 LOCATED IN BEDROOMS. 210.12.
  
 4} THE GFI'S SHOWN IN THE DINING ROOM
 AND BREAKFAST NOOK, WHILE NOT REQUIRED
 ALTHOUGH PERMISSIBLE, MUST BE INSTALLED
 IF LEFT ON THE PLAN.
  
 5} A RECEPTACLE NEEDS TO BE ADDED TO
 THEMASTER BEDROOM TO COMPLY WITH
 210.52(A).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-03-09 Cont ID  
Sent By adarroug Date 2006-03-09 Time 15:49 Rev Time 0.00
Received By adarroug Date 2006-03-09 Time 15:49 Sent To E
Notes
2006-03-09 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-01-18 Cont ID  
Sent By adarroug Date 2006-01-18 Time 14:11 Rev Time 0.00
Received By adarroug Date 2006-01-18 Time 14:11 Sent To E
Notes
2006-01-18 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-30 Cont ID  
Sent By adarroug Date 2005-08-30 Time 08:41 Rev Time 0.00
Received By adarroug Date 2005-08-30 Time 08:41 Sent To B
Notes
2005-08-30 00:00:00TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-18 Cont ID  
Sent By adarroug Date 2005-07-18 Time 12:04 Rev Time 0.00
Received By adarroug Date 2005-07-18 Time 12:04 Sent To E
Notes
2005-07-18 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 17:24 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 17:20 Sent To E
Notes
2005-05-24 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 08:10 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 08:10 Sent To E
Notes
2005-01-06 00:00:00TO "SFD" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2005-01-03 Time 10:59 Rev Time 0.00
Received By mjacobs Date 2005-01-03 Time 10:59 Sent To Z
Notes
2005-01-03 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-11 Cont ID  
Sent By prafter Date 2005-01-11 Time 16:01 Rev Time 0.45
Received By prafter Date 2005-01-11 Time 16:01 Sent To B
Notes
2005-01-11 00:00:00NO A/C PLANS.
 PAT RAFTER 561/805/6725 OR 805/6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-09-26 Cont ID  
Sent By jleech Date 2005-09-26 Time 07:13 Rev Time 0.33
Received By jleech Date 2005-09-26 Time 07:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-07 Cont ID  
Sent By jleech Date 2005-06-07 Time 18:14 Rev Time 0.25
Received By jleech Date 2005-06-07 Time 18:14 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-10 Cont ID  
Sent By jleech Date 2005-01-10 Time 17:21 Rev Time 0.33
Received By jleech Date 2005-01-10 Time 17:21 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By mmclean Date 2005-01-05 Time 18:56 Rev Time 0.00
Received By mmclean Date 2005-01-05 Time 18:56 Sent To I
Notes
2005-01-05 00:00:00MUST PULL SEPERATE PERMIT FOR POOL/DECK