| Plan Review Stops For Permit 04121950 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-10 |
Time |
18:16 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-11-10 |
Time |
18:16 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | SHUTTERS REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-28 |
Time |
10:11 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-04-28 |
Time |
10:11 |
Sent To |
PC |
|
| Notes |
| 2005-04-28 00:00:00 | SUBMITTAL RESPONDING TO PROVISO DATED | | | 3-29-05. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-29 |
Time |
16:41 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-03-29 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2005-03-29 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | PROVIDE THE FOLLOWING INFORMATION PRIOR | | | TO INSTALLATION OR CONSTRUCTION TO AVOID | | | CONFLICTS OR DELAYS. | | | 1- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENING AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 2- UPDATE TRUSS ANCHOR SCHEDULE. SEE | | | LATEST CATALOGUE OR PROVIDE COMPLETE | | | ENGINEERING CALCS THAT COMPLY WITH SEC. | | | 1609.4.3 FBC 2001. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A) FRENCH DOORS WITH | | | OUTSWING AND SIZE AS SHOWN ON PLANS. | | | B) USP OR SIMPSON TRUSS CONNECTORS. | | | | | | 4- PLANS CALL FOR FLAT ROOF SYSTEM. | | | PRODUCT APPROVAL SUBMITTED IS FOR "S". | | | TILE. REVISE AS REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-02-01 |
Time |
08:55 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-02-01 |
Time |
08:55 |
Sent To |
PC |
|
| Notes |
| 2005-01-31 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE BATHROOM WITH DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2- SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4- A) NEED NAME OF ARCHITECT SEALING THE | | | PLANS. CHAPTER 61G1-16004 FAC. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE DETAIL/SPECS FOR | | | CEILING INSTALLATION AT ENTRY AND REAR | | | PORCHES. SPECIFY FASTENER SIZE AND | | | SPACING. SEE ASTM C926 AND ASTM C1063. | | | SECTION 2504.2 FBC 2001. | | | | | | 6- OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS. | | | | | | 7- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS. SEE SIZES ON PLANS. | | | B) FRENCH DOORS. SEE SIZES ON PLANS. | | | C) CONCRETE LINTELS: NEED SAME DADE | | | COUNTY NOA THAT WAS SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE DESIGN | | | PRESSURES AND SIZES AS SHOWN ON PLANS. | | | E) ARABESQUE WINDOW. SEE PLANS. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. SEC. 2806 FBC | | | 2001. | | | B) PROVIDE COMPLETE APPROVED BBQ SPECS. | | | SECTION 2808 FBC 2001. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISE MIN. PANEL SIZE. SEE | | | ENGINEERED DRAWINGS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS FOR LOCATION. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.1 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- OWES $866.23 FOR UPDATED VALUATION. | | | | | | 12- REVISE FOUNDATIOON NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE CONNECTORS SPECIFIED ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-11-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-12 |
Time |
21:15 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-11-12 |
Time |
21:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-10-14 |
Time |
12:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-10-14 |
Time |
12:04 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-22 |
Time |
19:55 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | ********** PROVISO ************ | | | | | | 1)NOTE: PLEASE SEE AHU'S AND CU'S ON | | | PANEL SCHEDULES AND LOAD CALCULATIONS. | | | PLEASE CORRELATE OCP, AWG AND KW LOADS | | | FOR EACH. | | | PLEASE ADJUST LOAD CALCULATIONS AS | | | NEEDED. | | | | | | 2)NOTE: PLEASE SEE 110.26 FOR MIN | | | CLEARENCE REQUIRED FOR POOL PANEL. | | | | | | 3)NOTE: PLEASE SEE DISH/DISP IS SHOWN AS | | | 2-P, HOWEVER ONLY INDICATES ONE CIRCUIT | | | SPACE ON PANEL SCHEDULE. | | | | | | 4)NOTE: PLEASE SEE RISER INDICATES 2/0'S | | | FOR 150A MAINS, THIS IS OK, HOWEVER IF | | | 2/0'S ARE SHOWN THEN THIS IS WHAT WILL | | | BE REQUIRED TO BE INSTALLED. | | | ***THIS IS ONLY A NOTE*** | | | | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW ALONG | | | WITH ANY OTHER REVISIONS BEFORE FINAL | | | ELECTRICAL INSPECTION IS CALLED IN. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-03-22 |
Time |
11:01 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-03-22 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
12:26 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
12:17 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THE MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:32 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-14 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-14 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2005-10-14 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-22 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-22 |
Time |
15:18 |
Sent To |
E |
|
| Notes |
| 2005-09-22 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-18 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-18 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | TO "JGOMEZ" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-15 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-15 |
Time |
11:19 |
Sent To |
E |
|
| Notes |
| 2005-03-15 00:00:00 | TO "BT" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:45 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
11:02 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
16:11 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
16:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
17:37 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
17:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:11 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|