Plan Review Details - Permit 04121938
Plan Review Stops For Permit 04121938
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-05-27 Cont ID  
Sent By rmcdouga Date 2005-05-27 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2005-05-27 Time 07:30 Sent To  
Notes
2005-05-27 00:00:00REVISED SHEETS A2, A3 AND A5.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-03-22 Cont ID  
Sent By rmcdouga Date 2005-03-22 Time 12:41 Rev Time 0.00
Received By rmcdouga Date 2005-03-22 Time 12:41 Sent To  
Notes
2005-03-22 00:00:00REVISION TO FRONT ENTRY DOORS IS OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-28 Cont ID  
Sent By rmcdouga Date 2005-02-28 Time 07:53 Rev Time 0.00
Received By rmcdouga Date 2005-02-28 Time 07:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-24 Cont ID  
Sent By rmcdouga Date 2005-01-24 Time 16:25 Rev Time 0.00
Received By rmcdouga Date 2005-01-24 Time 16:25 Sent To  
Notes
2005-01-24 00:00:00DENIED
  
 1) SPECIFY ON SHEET A3 THAT THE GLASS
 BLOCK ON THE ZERO LOT LINE IS ONE HOUR
 FIRE RATED.
  
 2) ONE OF THE WINDOWS IN BEDROOM #3
 SPECIFIED AS AN EGRESS WINDOW IS MARKED
 AS A H33 SH, WHICH DOES NOT MEET EGRESS
 REQUIREMENTS.
  
 3) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING INFORMATION FOR THE BBQ AND THE
 PREFAB FIREPLACE.
  
 4) FBC 1007.8.1 REQUIRES STAIR WINDERS
 TO HAVE A MINIMUM TREAD DEPTH OF 6" AT
 THE NARROW EDGE AND A MINIMUM TRED DEPTH
 OF 11" AT A POINT 12" FROM THE NARROW
 EDGE.
  
 5) PROVIDE DETAILS OF THE HANDRAILS AND
 GUARDRAILS AT THE STAIRS. SEE FBC 1007.5
 AND 1015.
  
 6) SPECIFY THE WINDLOAD PRESSURES FOR
 THE 7' X 5' FIXED GLASS WINDOW AT THE
 BREAKFAST NOOK.
  
 7) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 ANCHOR BOLTS IN DETAIL 6 ON A7.
  
 8) THE DETAIL FOR THE WOOD FRAME WALL ON
 A8 SPECIFIES A USP RT16F AT THE BOTTOM
 OF THE WALL AND DETAIL 7 ON A12
 SPECIFIES A USP RT18F AT THIS LOCATION.
 PLEASE CLARIFY.
  
 9) THE GLASS BLOCK DETAIL ON A12
 INCORRECTLY REFERENCES ASCE 7-88. THE
 CORRECT REFERENCE IS ASCE 7-98.
  
 10) SECTIONS 1 AND 2 ON A13 SPECIFY
 FIRESTOPS AT 8 INCHES ON CENTER. PLEASE
 CORRECT.
  
 11) THE OWNER/AGENT IS REQUIRED TO SIGN
 THE ENERGY CALC. FORMS PER FBC CHAPTER
 13.
  
 12) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK. THE PRODUCT
 APPROVAL SUBMITTED FOR THE GLASS BLOCK
 IS FOR SILICONE SET AND MAY NOT PROVIDE
 THE REQUIRED FIRE RATING OBTAINED WITH
 MORTAR SET. REFER TO SPECS.
  
 13) SUBMIT TWO COPIES OF STATE PRODUCT
 APPROVAL FOR THE LARGE OVERHEAD GARAGE
 DOOR.
  
 14) SUBMIT PRODUCT APPROVALS FOR THE
 DOUBLE OUTSWING GLAZED WOOD ENTRY
 DOORS.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE
 SINGLE OUTSWING GLAZED FRENCH DOOR AT
 THE MASTER SUITE.
  
 16)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 17) THE PRODUCT APPROVALS SUBMITTED FOR
 THE MULLIONS DO NOT MEET THE REQUIRED
 PRESSURES FOR USE BETWEEN THE 12'
 SLIDING GLASS DOOR AND TRANSOM AT THE
 FAMILY ROOM.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-11-12 Cont ID  
Sent By jleahy Date 2005-11-12 Time 21:06 Rev Time 0.30
Received By jleahy Date 2005-11-12 Time 21:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-05-18 Cont ID  
Sent By dpalmer Date 2005-05-18 Time 06:55 Rev Time 0.20
Received By dpalmer Date 2005-05-18 Time 06:55 Sent To  
Notes
2005-05-18 00:00:00************ UNSAT ************
  
 **PLEASE SEE PLANS AND RISER DIAGRAM
 HAVE COMPLETELY CHANGED FROM ORIG PLANS.
  
 1)NOTE: PLEASE SEE NEW RISER NOW
 INDICATES THREE ELECTRICAL PANELS,
 HOWEVER NO OCP IS SHOWN ON RISER FOR NEW
 PANELS.
 IS THERE NOW A PANEL SCHEDULE FOR NEW
 METER/MAIN COMBO.
 215.5,240.4, 310.16 ETC.
  
 2)NOTE: PLEASE SEE ONLY ONE PANEL IS
 SHOWN ON ELECTRICAL PLANS AND RISER
 SHOWS 3.
 215.5
  
 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON
 PANEL SCHEDULE INDICATE 20A OCP ON #14
 AWG. PLEASE SEE 310.16,240.4.
  
 4)NOTE: PLEASE SEE TWO #2 A/C SYSTEMS
 SHOWN ON PANEL SCHEDULES.
  
 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL
 TUB IS NOW ADDED TO PANEL SCHEDULE,
 HOWEVER NO ELECTRICAL IS SHOWN ON PLANS.
 PLEASE ALSO SEE 680.71 FOR REQUIRED
 INDICATION OF GFI PROTECTION.
  
 6)NOTE: PLEASE CORRELATE THE NUMBER OF
 RECESSED LTS ON PLANS WITH THE # OF
 RECESSED LTS INDICATED ON PANEL
 SCHEDULE/LOAD CALCULATIONS.
 PLEASE SEE SOME MODELS SHOW THESE AS
 "OPT". EACH PLAN MUST REFLECT THE ACTUAL
 INSTALLATION PER WHICH ARE INSTALLED OR
 NOT INSTALLED.
 215.5
  
 7)NOTE:
  
 8)NOTE:
  
 PLEASE SEE MANY OF THESE ITEMS HAVE BEEN
 REDLINED AT LOCATIONS ON PLANS AT
 LOCATIONS OF NOTES.
  
 *** PLEASE BE SURE ALL PLANS ARE SIGNED
 BY THE ARCHITECT OF RECORD.
 FS 481.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-02-17 Cont ID  
Sent By btrobaug Date 2005-02-17 Time 12:16 Rev Time 0.50
Received By btrobaug Date 2005-02-17 Time 11:49 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-07 Cont ID  
Sent By btrobaug Date 2005-01-07 Time 10:22 Rev Time 0.50
Received By btrobaug Date 2005-01-07 Time 09:50 Sent To M
Notes
2005-01-07 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE OVERCURRENT PROTECTION FOR AHU
 #2& #3 AT 60 AMPS IS TOO LARGE TO
 PROTECTA 5KW UNIT.(5000X125%/240=26
 AMPS, MAX30 AMP OCP). ALSO 60 AMP OCP
 SHOWN IN THE MAIN PANEL SEEMS TOO LARGE
 FOR THE CONDENSING UNITS. SEE ARTICLE
 440.22 NEC.
  
 2} THERE ARE ONLY TWO A/C DISCONNECTS
 SHOWN ON THE RISER, BUT THREE UNITS ON
 THE PLAN AND IN THE CALC. PLEASE
 CORRELATE.
  
 3} THERE ARE NO PROVISIONS IN THE
 CALCULATIONS FOR POOL EQUIPMENT, BUT
 THERE IS EQUIPMENT SHOWN ON THE PLAN.
  
 4} IF NOTE #14 IS ADHERED TO, THOSE
 CIRCUITS WOULD HAVE TO BE PROTECTED BY
 AN AFCI BECAUSE THE DETECTORS ARE
 LOCATED IN BEDROOMS. 210.12.
  
 5} THE GFI'S SHOWN IN THE DINING ROOM
 AND BREAKFAST NOOK, WHILE NOT REQUIRED
 ALTHOUGH PERMISSIBLE, MUST BE INSTALLED
 IF LEFT ON THE PLAN.
  
 6} RECEPTACLES MUST BE ADDED TO THE
 MASTER SUITE AND HOBBY ROOM TO COMPLY
 WITH 210.52(A). SEE REVIEWED SET OF
 PLANS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 09:25 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 09:25 Sent To P
Notes
2005-12-20 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-11-30 Cont ID  
Sent By adarroug Date 2005-11-30 Time 18:39 Rev Time 0.00
Received By amorse Date 2005-11-30 Time 18:39 Sent To B
Notes
2005-12-01 00:00:00RESTAMP FOR GAS PERMIT SENT TO PLUMBING
2005-11-30 00:00:00TO "RMCDOUGAL" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 18:01 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 18:01 Sent To B
Notes
2005-05-24 00:00:00TO "RMCDOUGAL" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-04-15 Cont ID  
Sent By adarroug Date 2005-04-15 Time 16:47 Rev Time 0.00
Received By adarroug Date 2005-04-15 Time 16:47 Sent To E
Notes
2005-04-15 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-03-18 Cont ID  
Sent By adarroug Date 2005-03-18 Time 13:25 Rev Time 0.00
Received By adarroug Date 2005-03-18 Time 13:25 Sent To B
Notes
2005-03-18 00:00:00TO "RMCDOUGAL" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-15 Cont ID  
Sent By adarroug Date 2005-02-15 Time 09:27 Rev Time 0.00
Received By adarroug Date 2005-02-15 Time 09:27 Sent To E
Notes
2005-02-15 00:00:00TO BTROBUAG DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 08:21 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 08:21 Sent To E
Notes
2005-01-06 00:00:00TO "SFD" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2005-01-03 Time 12:10 Rev Time 0.00
Received By mjacobs Date 2005-01-03 Time 12:10 Sent To Z
Notes
2005-01-03 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-10 Cont ID  
Sent By prafter Date 2005-01-10 Time 10:56 Rev Time 0.45
Received By prafter Date 2005-01-10 Time 10:56 Sent To P
Notes
2005-01-10 00:00:00NO A/C PLANS AND NO ENERGY MANUAL J
 CAULKS.
 PAT RAFTER561/805/6725 OR 805/6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-12-21 Cont ID  
Sent By jleech Date 2005-12-21 Time 14:09 Rev Time 0.33
Received By jleech Date 2005-12-21 Time 14:09 Sent To  
Notes
2005-12-21 00:00:00REVISED SANITARY RISER DIAGRAM TO MATCH
 INSTALLATION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-11 Cont ID  
Sent By jleech Date 2005-01-11 Time 14:08 Rev Time 0.33
Received By jleech Date 2005-01-11 Time 14:08 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By mmclean Date 2005-01-05 Time 18:51 Rev Time 0.00
Received By mmclean Date 2005-01-05 Time 18:51 Sent To I
Notes
2005-01-05 00:00:00MUST PULL SEPERATE PERMIT FOR POOL/DECK