| Plan Review Stops For Permit 04121938 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-27 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-27 |
Time |
07:30 |
Sent To |
|
|
| Notes |
| 2005-05-27 00:00:00 | REVISED SHEETS A2, A3 AND A5. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-22 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-22 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | REVISION TO FRONT ENTRY DOORS IS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-28 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-28 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-24 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-24 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | DENIED | | | | | | 1) SPECIFY ON SHEET A3 THAT THE GLASS | | | BLOCK ON THE ZERO LOT LINE IS ONE HOUR | | | FIRE RATED. | | | | | | 2) ONE OF THE WINDOWS IN BEDROOM #3 | | | SPECIFIED AS AN EGRESS WINDOW IS MARKED | | | AS A H33 SH, WHICH DOES NOT MEET EGRESS | | | REQUIREMENTS. | | | | | | 3) SUBMIT THE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE BBQ AND THE | | | PREFAB FIREPLACE. | | | | | | 4) FBC 1007.8.1 REQUIRES STAIR WINDERS | | | TO HAVE A MINIMUM TREAD DEPTH OF 6" AT | | | THE NARROW EDGE AND A MINIMUM TRED DEPTH | | | OF 11" AT A POINT 12" FROM THE NARROW | | | EDGE. | | | | | | 5) PROVIDE DETAILS OF THE HANDRAILS AND | | | GUARDRAILS AT THE STAIRS. SEE FBC 1007.5 | | | AND 1015. | | | | | | 6) SPECIFY THE WINDLOAD PRESSURES FOR | | | THE 7' X 5' FIXED GLASS WINDOW AT THE | | | BREAKFAST NOOK. | | | | | | 7) SPECIFY THE LENGTH/EMBED DEPTH OF THE | | | ANCHOR BOLTS IN DETAIL 6 ON A7. | | | | | | 8) THE DETAIL FOR THE WOOD FRAME WALL ON | | | A8 SPECIFIES A USP RT16F AT THE BOTTOM | | | OF THE WALL AND DETAIL 7 ON A12 | | | SPECIFIES A USP RT18F AT THIS LOCATION. | | | PLEASE CLARIFY. | | | | | | 9) THE GLASS BLOCK DETAIL ON A12 | | | INCORRECTLY REFERENCES ASCE 7-88. THE | | | CORRECT REFERENCE IS ASCE 7-98. | | | | | | 10) SECTIONS 1 AND 2 ON A13 SPECIFY | | | FIRESTOPS AT 8 INCHES ON CENTER. PLEASE | | | CORRECT. | | | | | | 11) THE OWNER/AGENT IS REQUIRED TO SIGN | | | THE ENERGY CALC. FORMS PER FBC CHAPTER | | | 13. | | | | | | 12) SUBMIT THE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE ONE HOUR | | | FIRE RATED GLASS BLOCK. THE PRODUCT | | | APPROVAL SUBMITTED FOR THE GLASS BLOCK | | | IS FOR SILICONE SET AND MAY NOT PROVIDE | | | THE REQUIRED FIRE RATING OBTAINED WITH | | | MORTAR SET. REFER TO SPECS. | | | | | | 13) SUBMIT TWO COPIES OF STATE PRODUCT | | | APPROVAL FOR THE LARGE OVERHEAD GARAGE | | | DOOR. | | | | | | 14) SUBMIT PRODUCT APPROVALS FOR THE | | | DOUBLE OUTSWING GLAZED WOOD ENTRY | | | DOORS. | | | | | | 15) SUBMIT PRODUCT APPROVALS FOR THE | | | SINGLE OUTSWING GLAZED FRENCH DOOR AT | | | THE MASTER SUITE. | | | | | | 16)FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 17) THE PRODUCT APPROVALS SUBMITTED FOR | | | THE MULLIONS DO NOT MEET THE REQUIRED | | | PRESSURES FOR USE BETWEEN THE 12' | | | SLIDING GLASS DOOR AND TRANSOM AT THE | | | FAMILY ROOM. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-11-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-12 |
Time |
21:06 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-11-12 |
Time |
21:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
06:55 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
06:55 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: PLEASE SEE TWO #2 A/C SYSTEMS | | | SHOWN ON PANEL SCHEDULES. | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | PLEASE SEE SOME MODELS SHOW THESE AS | | | "OPT". EACH PLAN MUST REFLECT THE ACTUAL | | | INSTALLATION PER WHICH ARE INSTALLED OR | | | NOT INSTALLED. | | | 215.5 | | | | | | 7)NOTE: | | | | | | 8)NOTE: | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-17 |
Time |
12:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-17 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
10:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
09:50 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2& #3 AT 60 AMPS IS TOO LARGE TO | | | PROTECTA 5KW UNIT.(5000X125%/240=26 | | | AMPS, MAX30 AMP OCP). ALSO 60 AMP OCP | | | SHOWN IN THE MAIN PANEL SEEMS TOO LARGE | | | FOR THE CONDENSING UNITS. SEE ARTICLE | | | 440.22 NEC. | | | | | | 2} THERE ARE ONLY TWO A/C DISCONNECTS | | | SHOWN ON THE RISER, BUT THREE UNITS ON | | | THE PLAN AND IN THE CALC. PLEASE | | | CORRELATE. | | | | | | 3} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 4} IF NOTE #14 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 5} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 6} RECEPTACLES MUST BE ADDED TO THE | | | MASTER SUITE AND HOBBY ROOM TO COMPLY | | | WITH 210.52(A). SEE REVIEWED SET OF | | | PLANS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-20 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-20 |
Time |
09:25 |
Sent To |
P |
|
| Notes |
| 2005-12-20 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-30 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2005-11-30 |
Time |
18:39 |
Sent To |
B |
|
| Notes |
| 2005-12-01 00:00:00 | RESTAMP FOR GAS PERMIT SENT TO PLUMBING | | 2005-11-30 00:00:00 | TO "RMCDOUGAL" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
18:01 |
Sent To |
B |
|
| Notes |
| 2005-05-24 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:47 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-18 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-18 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
| 2005-03-18 00:00:00 | TO "RMCDOUGAL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
09:27 |
Sent To |
E |
|
| Notes |
| 2005-02-15 00:00:00 | TO BTROBUAG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:21 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
12:10 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-10 |
Time |
10:56 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-10 |
Time |
10:56 |
Sent To |
P |
|
| Notes |
| 2005-01-10 00:00:00 | NO A/C PLANS AND NO ENERGY MANUAL J | | | CAULKS. | | | PAT RAFTER561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-21 |
Time |
14:09 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-12-21 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | REVISED SANITARY RISER DIAGRAM TO MATCH | | | INSTALLATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-11 |
Time |
14:08 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-11 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:51 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|