| 2005-09-21 00:00:00 | BUILDING REVISION CHECKLIST: | | | 1- STORM SHUTTERS KEY PLAN DOESN'T MATCH | | | FLOOR PLANS. REVISE AS REQUIRED. | | | | | | 2- REVISE INSTALLATION SCHEDULE TO | | | PROVIDE MINIMUM REQUIRED INFORMATION. | | | SEE ATTACHED SAMPLE WHICH IS MORE | | | COMPLETE THAN THE ONE SUBMITTED. SECTION | | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- CLEARLY MARK ON SHUTTER DRAWINGS | | | SPECIFIC MOUNTING CONDITIONS AND ANCHOR | | | TYPE AND SPACING TO BE USED ACCORDING TO | | | THE DESIGN PRESSURES, EDGE DISTANCE, | | | PANEL SPAN, CONNECTION TYPE AND | | | STRUCTURE TO BE ATTACHED TO (CONCRETE OR | | | CONCRETE BLOCK). SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 4- ACCORDING TO MAXIMUM PANEL SPAN CHART | | | ON DRAWINGS 4 OF 7 OPENING #12 EXCEEDS | | | THE MAXIMUM SPAN. REVISE AS REQUIRED. | | | SECTION 104.2.1.2 CITY AMENDMENTS TO FBC | | | 2001. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-28 |
Time |
11:39 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-04-28 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
| 2005-04-28 00:00:00 | SUBMITTAL TO ADDRESS PROVISO DATED | | | 3-10-05. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-10 |
Time |
09:09 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-03-10 |
Time |
09:09 |
Sent To |
PC |
|
| Notes |
| 2005-03-10 00:00:00 | BUILDING REVIEW PROVISO: | | | PROVIDE INFORMATION PRIOR TO | | | INSTALLATION OR CONSTRUCTION TO AVOID | | | CONFLICTS OR DELAYS: | | | 1- PRODUCT APPROVAL FOR ENTRY DOORS. | | | NOTE: ENTRY DOORS NEEDS TO BE SOLID OR | | | TO HAVE IMPACT GLAZING BECAUSE IS USED | | | FOR EMERGENCY EGRESS. NO SHUTTERS | | | ALLOWED FOR ENTRY DOOR. | | | | | | 2- UPDATE/REVISE TRUSS ANCHOR SCHEDULE | | | AND CALCULATIONS IF CONNECTOR'S CAPACITY | | | AND NUMBER OF NAILS DIFFER FROM THOSE | | | TESTED AND PUBLISHED BY MANUFACTURER. | | | **NOTE: CALCULATIONS NEED TO CONSIDER | | | SEC. 1609.4.3 FBC 2001. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) USP CONNECTORS SPECIFIED ON PLANS AND | | | TRUSS ANCHOR SCHEDULE. | | | | | | B) CASEMENT WINDOW ASSEMBLIES AS SHOWN | | | ON PLANS (SEE BEDROOM #2). | | | | | | C) FRENCH DOORS WITH SIZE AND SWING | | | DIRECTION AS SHOWN ON PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-21 |
Time |
16:44 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2005-01-21 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2005-01-21 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-PROVIDE COMPLETE BATHROOM WITH A DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING AS | | | REQUIRED BY SEC. 11-11 OF FBC 2001. | | | | | | 2-SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 104.2.1.1 OF CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 3-UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT | | | DIFFER | | | FROM THOSE TESTED AND PUBLISHED ON | | | MANUFACTURER'S CATALOGUE REFLECTING NO | | | STRESS INCREASE AS REQUIRED BY SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4-TITLE BLOCK TO HAVE ALL INFORMATION | | | AS | | | REQUIRED BY CHAPTER 481 FLORIDA | | | STATUTES | | | AND CHAPTER 61G1-16.004 OF | | | ADMINISTRATIVE CODE. INCLUDING NAME OF | | | ARCHITECT SEALING THE PLANS. | | | ***ALSO, STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5-PROVIDE COMPLETE | | | DETAIL/SPECIFICATIONS | | | FOR INSTALLATION OF CEILING AT ENTRY | | | AND | | | REAR PORCHES. SPECIFY FASTENERS TYPE | | | AND | | | SPACING AS REQUIRED BY ASTM C926 AND | | | ASTM C1063. (SEC. 2504.2 FBC 2001.) | | | | | | 6-ENERGY CALCULATIONS: OWNER/AGENT TO | | | SIGN AND DATE BOTTOM OF FORM. | | | | | | 7-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR ENTRY DOORS AND ALL | | | EXTERIOR FRENCH DOORS. CHECK SIZES. | | | | | | 8-STORM SHUTTERS: A)KEY PLAN DON'T | | | MATCH | | | PLANS. | | | B)SEE ENGINEERED DRAWINGS FOR MIN. | | | PANEL | | | SIZE ALLOWED AND REVISEINSTALLATION | | | SCHEDULE AS REQUIRED.. | | | C) INTERIORAND END ZONES SHOWN ON | | | INSTALLATION SCHEUDLE ARE INCORRECT. | | | SEE | | | PLANS AND REVISE AS REQUIRED. | | | D) REVISE DESIGN PRESSURES SHOWN ON THE | | | INSTALLATION SCHEDULE. SEE PLANS.. | | | | | | 9-CONCRETE LINTELS PRODUCT APPROVAL: | | | PROVIDE COPIES OF MIAMI-DADE NOA REPORT | | | THAT WAS SUBMITTED FOR FLORIDA PRODUCT | | | APPROVAL. REPORT SUBMITTED HERE IS NOT | | | THE SAME. SEE INFORMATION ON FLORIDA | | | WEBSITE WWW.FLORIDABUILDING.ORG. | | | | | | 10-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR FIXED WINDOWS THAT MEET | | | THE | | | DESIGN PRESSURES CALCULATED ON PLANS. | | | | | | 11-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR ARABESQUE WINDOW SHOWN ON | | | FRONT ELEVATION. | | | | | | 12-PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 13-OWES $235.45 FOR UPDATED VALUATION. | | | | | | 14-FOUNDATION NOTES ON SHEET A-2: REVISE | | | NOTE #2. SEE CHAPTER 19 FBC 2001 FOR | | | PROPER ACI REFERENCE. | | | | | | 15-DETAIL 2/A-9: UPDATE CONNECTORS. | | | SEMCO IS OUT OF BUSINESS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
19:40 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-09-22 |
Time |
19:39 |
Sent To |
P |
|
| Notes |
| 2005-09-22 00:00:00 | TIME RELITIVE TO PHONE CALLS AND | | | MEETINGS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-20 |
Time |
12:56 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-20 |
Time |
12:56 |
Sent To |
P |
|
| Notes |
| 2005-09-20 00:00:00 | ******* UNSAT ********** | | | | | | PLEASE SEE REVISIONS WILL BE COMING BACK | | | FOR PLUMBING COMMENTS, PLEASE MAKE THE | | | BELOW CORRECTIONS AT THIS TIME. | | | | | | 1)NOTE: PLEASE SEE OCP FOR CON/A/C SYS | | | #1 WAS INCREASED TO 60A'S, HOWEVER | | | CONDUCTOR SIZE HAS NOT BEEN INCREASED. | | | PLEASE SEE 310.16,240.4 | | | | | | 2)NOTE: PLEASE SEE DISHWASHER /DISPOSAL | | | CIRCUIT HAS BEEN UPGRADED TO A 2-POLE | | | BRKR, HOWEVER CIRCUITING ON PANEL | | | SCHEDULE STILL SHOWS 1-POLE. | | | | | | 3)NOTE;PLEASE SEE ITEMS ON PLANS WHICH | | | INDICATE BEING "OPTIONAL". PLEASE REVISE | | | TO INCLUDE ACTUAL INSTALLATION OF | | | ELECTRICAL. IF AN APPLIANCE, THE | | | APPLIANCE DOES NOT HAVE TO BE INSTALLED | | | FOR ROUGH OR BEFORE FINAL. | | | ONLY THE ELECTRICAL FOR THE EQUIPMENT IS | | | TO BE SHOWN. | | | PLEASE KNOW, ELECTRICAL FOR WASHER | | | CIRCUIT CAN NOT BE OPTIONAL. | | | 210.52,210.11,220.16 | | | | | | 4)NOTE: PLEASE SEE LOCATION FOR POOL SUB | | | PANEL SHOULD BE LOCATED TO MEET 110.26 | | | FOR MIN CLEARNECES. | | | PLEASE SEE POOL EQUIPMENT WAS NOTED ON | | | PREVIOUS PLANS AS TO BE MOVED TO EXACT | | | LOCATION AT LATER DATE, HOWEVER THIS HAS | | | NOTBEEN REVISED AS OF YET? | | | 110.26 | | | | | | PLEASE SEE PLUMB COMMENTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-26 |
Time |
19:09 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-08-26 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | ELEC OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-15 |
Time |
21:16 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-07-15 |
Time |
21:16 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | REDLINED, | | | NO LTS SHOWN IN MASTER BATH. | | | MIN LT REQUIRED 210.70, LS 101 5-8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-17 |
Time |
11:59 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-05-17 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2005-05-17 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: PLEASE CORRELATE AHU#2 HEAT | | | STRIP WITH LOAD CALCULATIONS. | | | PLEASE SEE PANEL SCHEDULE INDICATES 5KW, | | | HOWEVER LOAD CALCS SHOW 10KW? | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | 215.5 | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-05-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-05 |
Time |
17:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-05 |
Time |
12:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-28 |
Time |
11:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-28 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
11:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
11:23 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THE | | | MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-16 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-16 |
Time |
16:59 |
Sent To |
E |
|
| Notes |
| 2005-09-16 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-24 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-24 |
Time |
19:23 |
Sent To |
E |
|
| Notes |
| 2005-08-24 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-23 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-23 |
Time |
18:18 |
Sent To |
B |
|
| Notes |
| 2005-08-23 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-15 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-15 |
Time |
16:34 |
Sent To |
E |
|
| Notes |
| 2005-07-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-18 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-18 |
Time |
09:46 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:46 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-23 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
09:25 |
Sent To |
E |
|
| Notes |
| 2005-02-15 00:00:00 | TO "BTROBAUG" DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:50 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
11:49 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
12:06 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
15:47 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | ON A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-24 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-24 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-24 |
Time |
12:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
16:14 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
16:14 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
12:08 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|