| Plan Review Stops For Permit 04121920 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-10-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-10-03 |
Time |
10:58 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-10-03 |
Time |
10:58 |
Sent To |
PC |
|
| Notes |
| 2005-10-03 00:00:00 | REVISION CHECKLIST: | | | 1- PROVIDE FLORIDA PRODUCT APPROVAL OR | | | APPLY FOR LOCAL PRODUCT APPROVAL FOR | | | STORM SHUTTERS AS REQUIRED BY RULE 9B-72 | | | OF DCA. DADE COUNTY NOA ALONE IS NOT | | | AUTOMATICALLY AN STATEWIDE PRODUCT | | | APPROVAL. MANUFACTURER MAY APPLY FOR | | | LOCAL PRODUCT APPROVAL USING THE DADE | | | COUNTY NOA AND COMPLETING THE LOCAL | | | PRODUCT APPROVAL FORM DOWNLOADED FROM | | | DCA WEBSITE WWW.FLORIDABUILDING.ORG. | | | | | | 2- KEY PLAN SHOWS THAT ENTRY DOOR WILL | | | HAVE SHUTTERS. CONTRACTOR SPECIFIED THAT | | | ENTRY DOOR WILL BE USED AS THE EMERGENCY | | | EGRESS AND IS IMPACT RESISTANT. REVISE | | | KEY PLAN AND INSTALLATION SCHEDULE | | | SHOWING ENTRY DOOR AS EMERGENCY EGRESS | | | WITH NO SHUTTERS. | | | | | | 3- PROVIDE A COMPLETE INSTALLATION | | | SCHEDULE WITH THE MINIMUM REQUIRED | | | INFORMATION. SEE ATTACHED SAMPLE AND | | | FILL COMPLETELY. | | | | | | 4- PANELS FOR OPENING #14 EXCEED THE | | | MAX. PANEL SPAN SHOWN ON DRAWING 4 OF 7. | | | REVISE AS REQUIRED. | | | | | | 5- THERE ARE TWO DIFFERENT SHUTTER TYPES | | | SUBMITTED (DIFFERENT GAUGE). CLARIFY | | | WHICH ONE IS GOING TO BE USED. | | | | | | 6- INDICATE IN THE INSTALLATION SCHEDULE | | | PAGE 5 OF 7 SPECIFIC ANCHOR TYPE AND | | | SPACING TO BE USED. INFORMATION | | | SUBMITTED SHOW THE ALL COLUMN BEING | | | HIGHLIGHTED. INDICATE SPECIFIC ANCHOR | | | THAT WILL BE USED IN THIS PROJECT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-28 |
Time |
10:43 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-04-28 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2005-04-28 00:00:00 | BUILDING SUBMITTAL RESPONDING TO PROVISO | | | DATED 3-2-05. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-02 |
Time |
15:42 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2005-03-02 |
Time |
15:42 |
Sent To |
PC |
|
| Notes |
| 2005-03-02 00:00:00 | BUILDING REVIEW PROVISO: | | | **NOTE: PROVIDE THE FOLLOWING | | | INFORMATION PRIOR TO CONSTRUCTION OR | | | INSTALLATION TO AVOID DELAYS/CONFLICTS: | | | 1- IF USING ENTRY DOOR FOR EGRESS AS | | | REQUIRED BY SEC. 1005.4.5 FBC 2001 AND | | | DOOR HAS GLAZING, THEN, GLAZING MUST BE | | | IMPACT PROTECTED OR SOLID DOOR. | | | | | | 2- UPDATE/REVISE TRUSS ANCHOR SCHEDULE | | | AND CALCULATIONS IF CONNECTOR'S CAPACITY | | | AND NUMBER OF NAILS DIFFER FROM THAT | | | TESTED AND PUBLISHED BY MANUFACTURER. | | | **NOTE: CALCULATIONS SHALL COMPLY WITH | | | SECTION 1609.4.3 FBC 2001. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR USP CONNECTORS SPECIFIED ON | | | TRUSS ANCHOR SCHEDULE. PAGE A-6. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-24 |
Time |
15:33 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-01-24 |
Time |
15:33 |
Sent To |
PC |
|
| Notes |
| 2005-01-24 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1-PROVIDE COMPLETE BATHROOM WITH A DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2-SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3-UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT | | | DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SEC. | | | 1609.4.3 FBC 2001. | | | | | | 4- A)TITLE BLOCK NEEDS NAME OF | | | ARCHITECT | | | SEALING THE PLANS. SEE CHAPTER | | | 61G1-16004 FLORIDA ADMINISTRATIVE CODE. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE DETAIL / SPECS FOR | | | INSTALLATION OF CEILING AT ENTRY AND | | | REAR PORCH. SPECIFY ALL FASTENERS AND | | | SPACING. SEE ASTM C926 AND ASTM C1063. | | | SEC. 2504.2 FBC 2001. | | | | | | 6-ENERGY CALCULATIONS: OWNER/AGENT TO | | | SIGN AND DATE BOTTOM OF FORM. | | | | | | 7-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A) ENTRY DOORS. | | | B) FRENCH DOORS. SEE SIZES ON PLANS. | | | C) CONCRETE LINTELS: NEED DADE COUNTY | | | NOA THAT MATCHES ONE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE DESIGN | | | PRESSURES CALCULATED ON PLANS. SEE | | | PLANS | | | FOR SIZES AND DESIGN PRESSURES. | | | E) ARABESQUE WINDOW AS SHOWN ON PLANS. | | | | | | 8-A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. | | | B) PROVIDE APPROVED BBQ SPECS. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISE MIN. PANEL SIZE. SEE | | | ENGINEERED DRAWINGS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS FOR LOCATION. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10-PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11-OWES $866.23 FOR UPDATED VALUATION. | | | | | | 12-REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2: SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13-REVISE DETAIL CONNECTORS SHOWN ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-21 |
Time |
16:30 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2005-09-21 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2005-09-21 00:00:00 | REV'S FOR FINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
21:01 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-09-09 |
Time |
20:58 |
Sent To |
|
|
| Notes |
| 2005-09-09 00:00:00 | RELDINED | | | | | | CORRELATE OCP, AWG AND KW RATING FOR | | | AHU#2, 5KW ON 60A OCP , W/ #6 AWG? | | | | | | PLEASE SEE 2/0'S SHOWN FOR 150A PANELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
07:28 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | PLEASE SEE SOME MODELS SHOW THESE AS | | | "OPT". EACH PLAN MUST REFLECT THE ACTUAL | | | INSTALLATION PER WHICH ARE INSTALLED OR | | | NOT INSTALLED. | | | 215.5 | | | | | | 7)NOTE: | | | | | | 8)NOTE: | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-06 |
Time |
12:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-06 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-17 |
Time |
09:02 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-17 |
Time |
08:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
10:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
10:46 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO THE | | | MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2005-09-27 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-18 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-18 |
Time |
09:48 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:44 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
16:06 |
Sent To |
E |
|
| Notes |
| 2005-02-14 00:00:00 | TO BTROBAUG DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:24 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
11:37 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
15:37 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
15:37 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 8056719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
16:47 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
16:47 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:40 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|