| Plan Review Stops For Permit 04121914 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-27 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-27 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2005-09-27 00:00:00 | DENIED BY BUILDING | | | | | | REVISIONS TO STORM PANELS ARE DENIED. | | | | | | 1) PRODUCT APPROVALS SUBMITTED | | | WITH PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT WWW.FLORIDABUILDING.ORG. PRODUCTS | | | WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE SUBMITTED WITH A COVER SHEET THAT | | | LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | | | | 2) THE DESIGN LOAD TABLES ARE FOR | | | EXPOSURE C AND A MAXIMUM 2:12 ROOF | | | PITCH. THE STRUCTURE IS EXPOSURE B WITH | | | A 5:12 PITCH ROOF. SHOW HOW THIS TABLE | | | WAS USED TO DETERMINE THE PRESSURES | | | LISTED IN YOUR INSTALLATION SCHEDULE. | | | | | | 3) THE MEAN ROOF HEIGHT OF THE STRUCTURE | | | IS 23'-9" AS SPECIFIED ON THE BUILDING | | | PLANS, NOT 26.5'. | | | | | | 4) THE END ZONE FOR THIS STRUCTURE IS | | | 5.7' WIDE. SOME OF THE OPENINGS ARE | | | LOCATED WITHIN THE END ZONE, BUT NONE | | | ARE LISTED ON THE INSTALLATION SCHEDULE. | | | | | | 5) SPECIFY THE EDGE DISTANCE ON | | | INSTALLATION SCHEDULE. | | | | | | 6) SPECIFY THE FASTENERS ON THE SCHEDULE | | | FOR EACH OPENING. SOME OF THE SPACINGS | | | THAT ARE HI-LITED ON THE PRODUCT | | | APPROVAL DIFFER FROM THE 16" SPACING | | | THAT IS LISTED FOR EVERY OPENING ON THE | | | INSTALLATION SCHEDULE BASED ON SPAN, | | | EDGE DISTANCE, CONNECTION TYPE, ANCHOR | | | TYPE AND SUBSTRATE TYPE. | | | | | | 7) OPENING 1 ON THE KEY PLAN SHOULD BE | | | ABOVE THE FRONT DOOR. | | | | | | 8) PROVIDE THE OPENING DIMENSIONS ON THE | | | KEY PLAN. THE # OF PANELS IS NOT | | | NECESSARY AND STEEL GAUGE IS IN THE | | | PRODUCT APPROVAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-22 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-22 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2005-02-22 00:00:00 | PROVISO | | | | | | 1) SUBMIT SHOP DRAWINGS FOR STAIR | | | GUARDRAILS AND HANDRAILS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-20 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-01 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | DENIED | | | | | | 1) SPECIFY ON SHEET A3 THAT THE GLASS | | | BLOCK AT THE ZERO LOT LINE IS ONE HOUR | | | FIRE RATED. | | | | | | 2) ONE OF THE WINDOWS IN BEDROOM #3 | | | SPECIFIED AS AN EGRESS WINDOW IS MARKED | | | AS AH33 SH, WHICH DOES NOT MEET EGRESS | | | REQUIREMENTS. | | | | | | 3) SUBMIT THE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATION FOR THE BBQ AND THE | | | PREFAB FIREPLACE. | | | | | | 4) FBC 1OO7.8.1 REQUIRES STAIR WINDERS | | | TO HAVE A MINIMUM TREAD DEPTH OF 6 | | | INCHES AT THE NARROW EDGE AND SHALL HAVE | | | A MINIMUM TREAD DEPTH OF 11 INCHES AT A | | | POINT 12 INCHES FROM THE NARROW EDGE. | | | | | | 5) PROVIDE DETAILS OF THE HANDRAILS AND | | | GUARD RAILS AT THE STAIRS. SEE FBC | | | 1007.5 AND 1015. | | | | | | 6) THE WINDLOAD PRESSURES FOR THE 7' X | | | 5' FIXED GLASS WINDOW AT THE BREAKFAST | | | NOOK ARE NOT GIVEN. | | | | | | 7) SPECIFY THE LENGTH/EMBED DEPTH OF THE | | | ANCHOR BOLTS FOR BUCKET DETAIL 6 ON A7. | | | | | | 8) THE DETAIL FOR WOOD FRAME WALL ON A8 | | | SPECIFIES A USP RT16F AT THE BOTTOM OF | | | THE WALL AND DETAIL 7 ON A12 SPECIFIES A | | | USP RT18F AT THE SAME LOCATION. PLEASE | | | CLARIFY. | | | | | | 9) THE GLASS BLOCK DETAIL ON A12 | | | REFERENCES ASCE 7-88. THE CORRECT | | | REFERENCE IS ASCE 7-98. | | | | | | 10) SECTIONS 1 AND 2 ON ON A13 SPECIFY | | | FIRE STOPS AT 8" O.C. PLEASE CORRECT. | | | | | | 11) THE OWNER AGENT IS REQUIRED TO SIGN | | | THE ENERGY CALCS. PER FBC CHAPTER 13. | | | | | | 12) ONLY ONE PRODUCT APPROVAL WAS | | | SUBMITTED FOR THE SMALL GARAGE DOOR. | | | | | | 13) SUBMIT 2 COPIES OF A KEY PLAN FOR | | | THE STORM PANELS. | | | | | | 14) SUBMIT PRODUCT APPROVALS FOR THE | | | DOUBLE OUTSWING WOOD GLAZED DOORS AT THE | | | ENTRY. | | | | | | 15)FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 16) THE PRODUCT APPROVAL SUBMITTED FOR | | | THE MULLIONS DO NOT MEET THE REQUIRED | | | PRESSURES FOR USE BETWEEN THE 12' | | | SLIDING GLASS DOOR AND TRANSOM AT THE | | | FAMILY ROOM. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-20 |
Time |
10:35 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-09-20 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2005-09-20 00:00:00 | ** PLANS REDLINED *** | | | | | | ALL REVISIONS AND OPTIONS ARE TO BE | | | REVISED , SUBMITTED AND REVIEWED BEFORE | | | ROUGH ELECTRICLA INSPECTION. | | | THIS IS NOT THE ACTUAL INSTALLATION OF | | | ANY APPLIANCES, ONLY THE INSTALLATION OF | | | ELECTRICAL WIRING ETC ASSOCIATED WITH | | | THE "FUTURE" INSTALLATION OF APPLIANCES | | | ETC. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-10 |
Time |
09:01 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-09-10 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2005-09-10 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM SHOWS A | | | 200A PANEL FOR PANEL "A" WITH 200A OCP | | | FEEDING SAME PANEL, HOWEVER FEEDER SIZES | | | ARE ONLY #1'S. | | | PLEASE SEE 240.4,310.15B6,310.16 | | | | | | 2)NOTE: PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR IS TO BE 1/0 FOR A | | | 400A SERVICE AS SHOWN ON RISER. | | | PLEASE SEE A #2 IS CURRENTLY SHOWN WHICH | | | WAS OK FOR PREVIOUS 300A SERVICE. | | | 250.66,31.15B6 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS SHOWN | | | ON PLANS AS "OPT". PLEASE SEE THAT ALL | | | OPTIONS AND REVISION ARE TO BE DONE | | | BEFORE ROUGH ELECTRICLA INSPECTION. | | | PLAN ALSO SHOW WASHER AS OPTIONAL, A | | | WASHER IS NOT REQUIRED BY CODE, HOWEVER | | | THE CIRCUIT IS. | | | 210.11C2, 210.52 | | | PLEASE SEE PLANS ALSO DENBOTE THIS | | | REVISION AS BEING THE "AS-BUILT " | | | CONDITION. | | | | | | 4)NOTE: PLEASE SEE GDO'S SHOWN AS .9KW | | | ON PANEL SCHEDULE AND .7KW ON LOAD | | | CALCS, PLEASE CORRELATE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DONOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-17 |
Time |
12:44 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-05-17 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2005-05-17 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | ?? | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | 215.5 | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-07 |
Time |
15:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-07 |
Time |
14:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-06 |
Time |
18:46 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-06 |
Time |
18:44 |
Sent To |
M |
|
| Notes |
| 2005-01-06 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 | | | & #3 AT 60 AMPS IS TOO LARGE TO PROTECT | | | A 5KW UNIT.(5000X125%/240=26 AMPS, MAX | | | 30 AMP OCP). ALSO 60 AMP OCP SHOWN IN | | | THE MAIN PANEL SEEMS TOO LARGE FOR THE | | | CONDENSING UNITS. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE ONLY TWO A/C DISCONNECTS | | | SHOWN ON THE RISER, BUT THREE UNITS ON | | | THE PLAN AND IN THE CALC. PLEASE | | | CORRELATE. | | | | | | 3} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 4} IF NOTE #14 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 5} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 6} RECEPTACLES MUST BE ADDED TO THE | | | MASTER SUITE AND HOBBY ROOM TO COMPLY | | | WITH 210.52(A). SEE REVIEWED SET OF | | | PLANS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
08:22 |
Sent To |
B |
|
| Notes |
| 2005-09-27 00:00:00 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-16 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-16 |
Time |
17:20 |
Sent To |
E |
|
| Notes |
| 2005-09-16 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-22 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-22 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
| 2005-04-22 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-01 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-01 |
Time |
16:22 |
Sent To |
E |
|
| Notes |
| 2005-02-01 00:00:00 | TO "BTROBAUG" DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:59 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
11:06 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-10 |
Time |
10:41 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-10 |
Time |
10:41 |
Sent To |
P |
|
| Notes |
| 2005-01-10 00:00:00 | NO A/C PLANS AND ONLY ONE ENERGY MANUAL | | | J CAULK. | | | PAT RAFTER561/805/6725 OR 8056719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-11 |
Time |
14:06 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-11 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
17:23 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|