Plan Review Details - Permit 04121914
Plan Review Stops For Permit 04121914
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-09-27 Cont ID  
Sent By rmcdouga Date 2005-09-27 Time 15:57 Rev Time 0.00
Received By rmcdouga Date 2005-09-27 Time 15:57 Sent To  
Notes
2005-09-27 00:00:00DENIED BY BUILDING
  
 REVISIONS TO STORM PANELS ARE DENIED.
  
 1) PRODUCT APPROVALS SUBMITTED
 WITH PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT WWW.FLORIDABUILDING.ORG. PRODUCTS
 WITH STATEWIDE APPROVAL ARE REQUIRED TO
 BE SUBMITTED WITH A COVER SHEET THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM
 THE STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 2) THE DESIGN LOAD TABLES ARE FOR
 EXPOSURE C AND A MAXIMUM 2:12 ROOF
 PITCH. THE STRUCTURE IS EXPOSURE B WITH
 A 5:12 PITCH ROOF. SHOW HOW THIS TABLE
 WAS USED TO DETERMINE THE PRESSURES
 LISTED IN YOUR INSTALLATION SCHEDULE.
  
 3) THE MEAN ROOF HEIGHT OF THE STRUCTURE
 IS 23'-9" AS SPECIFIED ON THE BUILDING
 PLANS, NOT 26.5'.
  
 4) THE END ZONE FOR THIS STRUCTURE IS
 5.7' WIDE. SOME OF THE OPENINGS ARE
 LOCATED WITHIN THE END ZONE, BUT NONE
 ARE LISTED ON THE INSTALLATION SCHEDULE.
  
 5) SPECIFY THE EDGE DISTANCE ON
 INSTALLATION SCHEDULE.
  
 6) SPECIFY THE FASTENERS ON THE SCHEDULE
 FOR EACH OPENING. SOME OF THE SPACINGS
 THAT ARE HI-LITED ON THE PRODUCT
 APPROVAL DIFFER FROM THE 16" SPACING
 THAT IS LISTED FOR EVERY OPENING ON THE
 INSTALLATION SCHEDULE BASED ON SPAN,
 EDGE DISTANCE, CONNECTION TYPE, ANCHOR
 TYPE AND SUBSTRATE TYPE.
  
 7) OPENING 1 ON THE KEY PLAN SHOULD BE
 ABOVE THE FRONT DOOR.
  
 8) PROVIDE THE OPENING DIMENSIONS ON THE
 KEY PLAN. THE # OF PANELS IS NOT
 NECESSARY AND STEEL GAUGE IS IN THE
 PRODUCT APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-22 Cont ID  
Sent By rmcdouga Date 2005-02-22 Time 17:53 Rev Time 0.00
Received By rmcdouga Date 2005-02-22 Time 17:53 Sent To  
Notes
2005-02-22 00:00:00PROVISO
  
 1) SUBMIT SHOP DRAWINGS FOR STAIR
 GUARDRAILS AND HANDRAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-20 Cont ID  
Sent By rmcdouga Date 2005-01-20 Time 15:32 Rev Time 0.00
Received By adarroug Date 2005-02-01 Time 16:22 Sent To  
Notes
2005-01-20 00:00:00DENIED
  
 1) SPECIFY ON SHEET A3 THAT THE GLASS
 BLOCK AT THE ZERO LOT LINE IS ONE HOUR
 FIRE RATED.
  
 2) ONE OF THE WINDOWS IN BEDROOM #3
 SPECIFIED AS AN EGRESS WINDOW IS MARKED
 AS AH33 SH, WHICH DOES NOT MEET EGRESS
 REQUIREMENTS.
  
 3) SUBMIT THE MANUFACTURER'S SPECS. AND
 LISTING INFORMATION FOR THE BBQ AND THE
 PREFAB FIREPLACE.
  
 4) FBC 1OO7.8.1 REQUIRES STAIR WINDERS
 TO HAVE A MINIMUM TREAD DEPTH OF 6
 INCHES AT THE NARROW EDGE AND SHALL HAVE
 A MINIMUM TREAD DEPTH OF 11 INCHES AT A
 POINT 12 INCHES FROM THE NARROW EDGE.
  
 5) PROVIDE DETAILS OF THE HANDRAILS AND
 GUARD RAILS AT THE STAIRS. SEE FBC
 1007.5 AND 1015.
  
 6) THE WINDLOAD PRESSURES FOR THE 7' X
 5' FIXED GLASS WINDOW AT THE BREAKFAST
 NOOK ARE NOT GIVEN.
  
 7) SPECIFY THE LENGTH/EMBED DEPTH OF THE
 ANCHOR BOLTS FOR BUCKET DETAIL 6 ON A7.
  
 8) THE DETAIL FOR WOOD FRAME WALL ON A8
 SPECIFIES A USP RT16F AT THE BOTTOM OF
 THE WALL AND DETAIL 7 ON A12 SPECIFIES A
 USP RT18F AT THE SAME LOCATION. PLEASE
 CLARIFY.
  
 9) THE GLASS BLOCK DETAIL ON A12
 REFERENCES ASCE 7-88. THE CORRECT
 REFERENCE IS ASCE 7-98.
  
 10) SECTIONS 1 AND 2 ON ON A13 SPECIFY
 FIRE STOPS AT 8" O.C. PLEASE CORRECT.
  
 11) THE OWNER AGENT IS REQUIRED TO SIGN
 THE ENERGY CALCS. PER FBC CHAPTER 13.
  
 12) ONLY ONE PRODUCT APPROVAL WAS
 SUBMITTED FOR THE SMALL GARAGE DOOR.
  
 13) SUBMIT 2 COPIES OF A KEY PLAN FOR
 THE STORM PANELS.
  
 14) SUBMIT PRODUCT APPROVALS FOR THE
 DOUBLE OUTSWING WOOD GLAZED DOORS AT THE
 ENTRY.
  
 15)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 16) THE PRODUCT APPROVAL SUBMITTED FOR
 THE MULLIONS DO NOT MEET THE REQUIRED
 PRESSURES FOR USE BETWEEN THE 12'
 SLIDING GLASS DOOR AND TRANSOM AT THE
 FAMILY ROOM.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2005-09-20 Cont ID  
Sent By dpalmer Date 2005-09-20 Time 10:35 Rev Time 0.40
Received By dpalmer Date 2005-09-20 Time 10:21 Sent To  
Notes
2005-09-20 00:00:00** PLANS REDLINED ***
  
 ALL REVISIONS AND OPTIONS ARE TO BE
 REVISED , SUBMITTED AND REVIEWED BEFORE
 ROUGH ELECTRICLA INSPECTION.
 THIS IS NOT THE ACTUAL INSTALLATION OF
 ANY APPLIANCES, ONLY THE INSTALLATION OF
 ELECTRICAL WIRING ETC ASSOCIATED WITH
 THE "FUTURE" INSTALLATION OF APPLIANCES
 ETC.
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-09-10 Cont ID  
Sent By dpalmer Date 2005-09-10 Time 09:01 Rev Time 0.33
Received By dpalmer Date 2005-09-10 Time 09:00 Sent To  
Notes
2005-09-10 00:00:00************ UNSAT **************
  
 1)NOTE: PLEASE SEE RISER DIAGRAM SHOWS A
 200A PANEL FOR PANEL "A" WITH 200A OCP
 FEEDING SAME PANEL, HOWEVER FEEDER SIZES
 ARE ONLY #1'S.
 PLEASE SEE 240.4,310.15B6,310.16
  
 2)NOTE: PLEASE SEE MIN GROUNDING
 ELECTRODE CONDUCTOR IS TO BE 1/0 FOR A
 400A SERVICE AS SHOWN ON RISER.
 PLEASE SEE A #2 IS CURRENTLY SHOWN WHICH
 WAS OK FOR PREVIOUS 300A SERVICE.
 250.66,31.15B6
  
 3)NOTE: PLEASE SEE NUMEROUS ITEMS SHOWN
 ON PLANS AS "OPT". PLEASE SEE THAT ALL
 OPTIONS AND REVISION ARE TO BE DONE
 BEFORE ROUGH ELECTRICLA INSPECTION.
 PLAN ALSO SHOW WASHER AS OPTIONAL, A
 WASHER IS NOT REQUIRED BY CODE, HOWEVER
 THE CIRCUIT IS.
 210.11C2, 210.52
 PLEASE SEE PLANS ALSO DENBOTE THIS
 REVISION AS BEING THE "AS-BUILT "
 CONDITION.
  
 4)NOTE: PLEASE SEE GDO'S SHOWN AS .9KW
 ON PANEL SCHEDULE AND .7KW ON LOAD
 CALCS, PLEASE CORRELATE.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DONOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-05-17 Cont ID  
Sent By dpalmer Date 2005-05-17 Time 12:44 Rev Time 0.30
Received By dpalmer Date 2005-05-17 Time 12:44 Sent To  
Notes
2005-05-17 00:00:00************ UNSAT ************
  
 **PLEASE SEE PLANS AND RISER DIAGRAM
 HAVE COMPLETELY CHANGED FROM ORIG PLANS.
  
 1)NOTE: PLEASE SEE NEW RISER NOW
 INDICATES THREE ELECTRICAL PANELS,
 HOWEVER NO OCP IS SHOWN ON RISER FOR NEW
 PANELS.
 IS THERE NOW A PANEL SCHEDULE FOR NEW
 METER/MAIN COMBO.
 215.5,240.4, 310.16 ETC.
  
 2)NOTE: PLEASE SEE ONLY ONE PANEL IS
 SHOWN ON ELECTRICAL PLANS AND RISER
 SHOWS 3.
 215.5
  
 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON
 PANEL SCHEDULE INDICATE 20A OCP ON #14
 AWG. PLEASE SEE 310.16,240.4.
  
 4)NOTE:
  
 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL
 TUB IS NOW ADDED TO PANEL SCHEDULE,
 HOWEVER NO ELECTRICAL IS SHOWN ON PLANS.
 ??
 PLEASE ALSO SEE 680.71 FOR REQUIRED
 INDICATION OF GFI PROTECTION.
  
 6)NOTE: PLEASE CORRELATE THE NUMBER OF
 RECESSED LTS ON PLANS WITH THE # OF
 RECESSED LTS INDICATED ON PANEL
 SCHEDULE/LOAD CALCULATIONS.
 215.5
  
 PLEASE SEE MANY OF THESE ITEMS HAVE BEEN
 REDLINED AT LOCATIONS ON PLANS AT
 LOCATIONS OF NOTES.
  
 *** PLEASE BE SURE ALL PLANS ARE SIGNED
 BY THE ARCHITECT OF RECORD.
 FS 481.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-02-07 Cont ID  
Sent By btrobaug Date 2005-02-07 Time 15:09 Rev Time 0.50
Received By btrobaug Date 2005-02-07 Time 14:21 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-06 Cont ID  
Sent By btrobaug Date 2005-01-06 Time 18:46 Rev Time 0.50
Received By btrobaug Date 2005-01-06 Time 18:44 Sent To M
Notes
2005-01-06 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE OVERCURRENT PROTECTION FOR AHU
 #2
 & #3 AT 60 AMPS IS TOO LARGE TO PROTECT
 A 5KW UNIT.(5000X125%/240=26 AMPS, MAX
 30 AMP OCP). ALSO 60 AMP OCP SHOWN IN
 THE MAIN PANEL SEEMS TOO LARGE FOR THE
 CONDENSING UNITS. SEE ARTICLE 440.22
 NEC.
  
 2} THERE ARE ONLY TWO A/C DISCONNECTS
 SHOWN ON THE RISER, BUT THREE UNITS ON
 THE PLAN AND IN THE CALC. PLEASE
 CORRELATE.
  
 3} THERE ARE NO PROVISIONS IN THE
 CALCULATIONS FOR POOL EQUIPMENT, BUT
 THERE IS EQUIPMENT SHOWN ON THE PLAN.
  
 4} IF NOTE #14 IS ADHERED TO, THOSE
 CIRCUITS WOULD HAVE TO BE PROTECTED BY
 AN AFCI BECAUSE THE DETECTORS ARE
 LOCATED IN BEDROOMS. 210.12.
  
 5} THE GFI'S SHOWN IN THE DINING ROOM
 AND BREAKFAST NOOK, WHILE NOT REQUIRED
 ALTHOUGH PERMISSIBLE, MUST BE INSTALLED
 IF LEFT ON THE PLAN.
  
 6} RECEPTACLES MUST BE ADDED TO THE
 MASTER SUITE AND HOBBY ROOM TO COMPLY
 WITH 210.52(A). SEE REVIEWED SET OF
 PLANS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-09-27 Cont ID  
Sent By adarroug Date 2005-09-27 Time 08:22 Rev Time 0.00
Received By adarroug Date 2005-09-27 Time 08:22 Sent To B
Notes
2005-09-27 00:00:00TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-16 Cont ID  
Sent By adarroug Date 2005-09-16 Time 17:20 Rev Time 0.00
Received By adarroug Date 2005-09-16 Time 17:20 Sent To E
Notes
2005-09-16 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-22 Cont ID  
Sent By adarroug Date 2005-04-22 Time 15:20 Rev Time 0.00
Received By adarroug Date 2005-04-22 Time 15:20 Sent To E
Notes
2005-04-22 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-01 Cont ID  
Sent By adarroug Date 2005-02-01 Time 16:22 Rev Time 0.00
Received By adarroug Date 2005-02-01 Time 16:22 Sent To E
Notes
2005-02-01 00:00:00TO "BTROBAUG" DESK/RESUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 07:59 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 07:59 Sent To E
Notes
2005-01-06 00:00:00TO "SFD" RACK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2005-01-03 Time 11:06 Rev Time 0.00
Received By mjacobs Date 2005-01-03 Time 11:06 Sent To Z
Notes
2005-01-03 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-10 Cont ID  
Sent By prafter Date 2005-01-10 Time 10:41 Rev Time 0.45
Received By prafter Date 2005-01-10 Time 10:41 Sent To P
Notes
2005-01-10 00:00:00NO A/C PLANS AND ONLY ONE ENERGY MANUAL
 J CAULK.
 PAT RAFTER561/805/6725 OR 8056719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-11 Cont ID  
Sent By jleech Date 2005-01-11 Time 14:06 Rev Time 0.33
Received By jleech Date 2005-01-11 Time 14:06 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By mmclean Date 2005-01-05 Time 17:23 Rev Time 0.00
Received By mmclean Date 2005-01-05 Time 17:23 Sent To I
Notes
2005-01-05 00:00:00MUST PULL SEPERATE PERMIT FOR POOL/DECK


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved