| Plan Review Stops For Permit 04121902 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-12 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-12 |
Time |
07:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-05-18 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-05-18 |
Time |
07:16 |
Sent To |
P |
|
| Notes |
| 2005-05-18 00:00:00 | DENIED BY BUILDING | | | | | | 1) NOTICE OF COMMENCEMENT WILL HAVE TO | | | BE RE-RECORDED. WORK ON THE PROJECT MUST | | | BEGIN WITHIN 90 DAYS OF THE RECORDING | | | DATE OR NOTICE BECOMES VOID. FS 713.13 | | | | | | 2) THE WRONG NOA REPORT WAS SUBMITTED | | | FOR THE CASEMENT WINDOWS WITH FL#2766. | | | THE CORRECT NOA IS #03-0612.05. | | | | | | 3) SUBMIT STATE OR LOCAL PRODUCT | | | APPROVAL FOR THE SINGLE AND DOUBLE | | | OUTSWING GLAZED FRENCH DOORS. | | | | | | 4) THE KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS ARE | | | INCORRECT. THE KEY PLAN DOES NOT MATCH | | | THE FOOTPRINT OF THE STRUCTURE. THE | | | SCHEDULE LISTS IMPACT RESISTANT WINDOWS. | | | THE PRODUCT APPROVALS ARE FOR NON-IMPACT | | | WINDOWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-24 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-24 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | DENIED | | | | | | 1) ONE OF THE WINDOWS IN BEDROOM #3 | | | SPECIFIED AS AN EGRESS WINDOW IS LABELED | | | H33 SH, WHICH DOES NOT MEET EGRESS | | | REQUIREMENTS OF FBC 1005.4. | | | | | | 2) SUBMIT THE MANUFACTURER'S SPECS. AND | | | LISTING INFORMATIONFOR TH BBQ AND PREFAB | | | FIREPLACE. | | | | | | 3) FBC 1007.8.1 REQUIRES STAIR WINDERS | | | TO HAVE A MINIMUM TREAD DEPTH OF 6 | | | INCHES AT THE NARROW EDGE AND SHALL HAVE | | | A MINIMUM TREAD DEPTH OF 11 INCHES AT A | | | POINT 12 INCHES FROM THE NARROW EDGE. | | | | | | 4) PROVIDE DETAILS OF THE HANDRAILS AND | | | GUARD RAILS AT THE STAIRS. SEE FBC | | | 1007.5 AND 1015. | | | | | | 5) SPECIFY THE WINDLOAD PRESSURES FOR | | | THE 7' X 5' FIXED GLASS WINDOW AT THE | | | BREAKFAST NOOK. | | | | | | 6) SPECIFY THE LENGTH/EMBED DEPTH OF THE | | | ANCHOR BOLTS ON DETAIL 6 ON A7. | | | | | | 7) THE DETAIL FOR THE WOOD FRAME WALL ON | | | A8 SPECIFIES A USP RT16F AT THE BOTTOM | | | OF THE WALL AND DETAIL 7 ON A12 | | | SPECIFIES A USP RT18F AT THE SAME | | | LOCATION. PLEASE CLARIFY. | | | | | | 8) THE GLASS BLOCK DETAIL ON A12 | | | INCORRECTLY REFERENCES ASCE 7-88. THE | | | CORRECT REFERENCE IS ASCE 7-98. | | | | | | 9) SECTIONS 1 AND 2 ON A 13 SPECIFY FIRE | | | STOPS AT 8 INCHES ON CENTER. PLEASE | | | CORRECT. | | | | | | 10) THE OWNER/AGENT IS REQUIRED TO SIGN | | | THE ENERGY CALC. FORMS PER FBC CHAPTER | | | 13. | | | | | | 11) SUBMIT TWO COPIES OF A KEY PLAN FOR | | | THE STORM PANELS. | | | | | | 12) SUBMIT STATE/LOCAL PRODUCT APPROVALS | | | FOR THE DOUBLE OUTSWING WOOD GLAZED | | | DOORS AT THE ENTRY AND THE SINGLE | | | OUTSWING GLAZED DOOR AT THE MASTER | | | BEDROOM. | | | | | | 13)FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 14) THE PRODUCT APPROVAL SUBMITTED FOR | | | THE MULLIONS DO NOT MEET THE REQUIRED | | | PRESSURES FOR USE BETWEEN THE 12' | | | SLIDING GLASS DOOR AND THE TRANSOM AT | | | THE FAMILY ROOM. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-10 |
Time |
07:56 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-03-10 |
Time |
07:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-27 |
Time |
09:52 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2006-02-27 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-11-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-12 |
Time |
21:13 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-11-12 |
Time |
21:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-12 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-06-28 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2005-07-12 00:00:00 | OK PER B TROBAUGH 6/28/05 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-05-17 |
Time |
11:54 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-05-17 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2005-05-17 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} INDICATE THE LOCATION OF PANEL "B & | | | C". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 16,17 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | 4} THE WHIRLPOOL IN THE MASTER BATH | | | REQIURES GFI PROTECTION PER 680.71. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-06 |
Time |
18:18 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2005-01-06 |
Time |
17:15 |
Sent To |
M |
|
| Notes |
| 2005-01-06 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 | | | & #3 AT 60 AMPS IS TOO LARGE TO PROTECT | | | A 5KW UNIT.(5000X125%/240=26 AMPS, MAX | | | 30 AMP OCP). ALSO 60 AMP OCP SHOWN IN | | | THE MAIN PANEL SEEMS TOO LARGE FOR THE | | | CONDENSING UNITS. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE ONLY TWO A/C DISCONNECTS | | | SHOWN ON THE RISER, BUT THREE UNITS ON | | | THE PLAN AND IN THE CALC. PLEASE | | | CORRELATE. | | | | | | 3} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 4} IF NOTE #14 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 5} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 6} RECEPTACLES MUST BE ADDED TO THE | | | MASTER SUITE AND HOBBY ROOM TO COMPLY | | | WITH 210.52(A). SEE REVIEWED SET OF | | | PLANS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "JLEAHY" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-02-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-19 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-19 |
Time |
13:18 |
Sent To |
E |
|
| Notes |
| 2006-02-19 00:00:00 | TO "JLEAHY" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-10 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2005-11-10 |
Time |
14:53 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
14:24 |
Sent To |
E |
|
| Notes |
| 2005-06-20 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-16 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2005-05-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:18 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
10:50 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
14:45 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
14:45 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS AND ONLY ONE ENERGY | | | MANUALY J CAULK. . | | | PAT RAFTER 561/805/6725 OR8056719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-07-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-09 |
Time |
12:57 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-07-09 |
Time |
12:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-05-28 |
Time |
17:34 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2005-05-28 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2005-05-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT A-9 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. CORRECT THE | | | FOLLOWING: | | | A. CLEANOUT FOR THE WASH MACHINE SHALL | | | BE LOCATED 4' ABOVE THE FLOOR. SECTION | | | 708.10. | | | B. THE CABANA BATH IS NOT SHOWN ON THE | | | RISER DIAGRAM. SECTION 104.2.1. | | | C. THE FUTURE SINK PIPING IS UNCLEAR. | | | PLEASE INDICATE IF IT WILL BE LEFT UNDER | | | THE SLAB. IF NOT SHOW THE RISER AND | | | INDICATE METHOD OF VENT. SECTIONS | | | 104.2.1. & 901.2.1. | | | D. THE FITTING AT THE TOP OF THE RISER | | | TO THE SECOND FLOOR DOES NOT DIRECT THE | | | WASTE IN THE DIRECTION OF FLOW AS | | | REQUIRED IN SECTION 706.3. SEE RED LINE | | | EXAMPLE AT TOP OF RISER ONE SET OF | | | PLANS. | | | 2. LOOSE SHEETS ARE NOT ACCEPTABLE. | | | PLEASE SUBMIT 2 SETS OF PLANS PER | | | SECTIONS 104.2.1, AND 104.2.1.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-11 |
Time |
14:27 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-11 |
Time |
14:27 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:54 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|