| Plan Review Stops For Permit 04121890 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-09-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-16 |
Time |
16:44 |
Rev Time |
1.50 |
| Received By |
jgomez |
Date |
2005-09-16 |
Time |
16:44 |
Sent To |
PC |
|
| Notes |
| 2005-09-16 00:00:00 | BUILDING REVIEW PROVISO: | | | 1- SHUTTERS UNDER A SEPARATE PERMIT. | | | 2- IF INSTALLING BBQ, THEN NEED TO | | | PROVIDE COMPLETE INFORMATION UNDER A | | | SEPARATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-18 |
Time |
10:37 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-08-18 |
Time |
10:37 |
Sent To |
PC |
|
| Notes |
| 2005-08-18 00:00:00 | BUILDING REVIEW THIRD CHECKLIST: | | | 1- DESIGNER OF RECORD TO SPECIFY IN THE | | | DWGS THE ROOF TILE FASTENING AS REQ'D BY | | | SEC. 104.2.1.1 CITY AMENDMENTS TO FBC | | | 2001. IT'S THE DESIGNER RESPONSIBILITY, | | | NOT THE BUILDER. | | | | | | 2- REVISE FASTENERS FOR THD210 | | | CONNECTOR. SEE TECHNICAL BULLETIN. | | | | | | 3- BBQ WILL NOT BE INSTALLED AT THIS | | | TIME. FUTURE INSTALLATION AS MENTIONED | | | IN PLANS WILL REQUIRE SEPARATE PERMIT TO | | | VERIFY COMPLIANCE OF BBQ SPECS FOR PORCH | | | INSTALLATION. SEC. 2808 FBC 2001. | | | | | | 4- CLARIFY IF USING STORM SHUTTERS OR | | | IMPACT GLAZING. THERE IS A NOTE THAT | | | SHUTTERS UNDER SEPARATE PERMIT, WHILE, | | | PRODUCT APPROVAL SUBMITTED FOR CASEMENT | | | WINDOWS IS FOR IMPACT WINDOWS. CLARIFY | | | AND PROVIDE COMPLETE CONSISTENT | | | INFORMATION FOR EITHER METHOD. | | | | | | 5- OWES $334.26 FOR 2ND SUBMITTAL. NOTE: | | | ADDITIONAL RE-SUBMITTAL FEES WILL APPLY. | | | | | | 6- NOC WAS RE-RECORDED ON 5-20-05. MAY | | | NEED TO BE RE-RECORDED AFTER 90 DAYS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-08 |
Time |
09:35 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-06-08 |
Time |
09:35 |
Sent To |
PC |
|
| Notes |
| 2005-06-08 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENING AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 2- USP CONNECTOR THD210 AND THD210-2 IS | | | A WOOD TO WOOD CONNECTOR. NEED MASONRY | | | CONNECTOR. SEE CATALOGUE FOR PROPER | | | MASONRY CONNECTOR AND REVISE AS REQUIRED | | | | | | 3- BBQ INFORMATION SUBMITTED WILL BE | | | FORWARDED TO BUILDING OFFICIAL FOR | | | APPROVAL. | | | NOTE: THERE ARE SOME COMPANIES WHO HAVE | | | BBQ'S SPECIFICALLY DESIGNED FOR PORCHES | | | OR LANAIS. THEY REQUIRE EXHAUST HOOD. | | | BUILDING OFFICIAL MAY ASK FOR ADDITIONAL | | | INFORMATION OR TESTING TO SUPPORT | | | ALFRESCO GRILLS' LETTER STATEMENT THAT | | | HOOD IS NOT REQUIRED. SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 4- WINDOW MULLIONS: CLEARLY SPECIFY | | | MULLION SIZE AND ANCHORS TO BE USED TO | | | VERIFY ADEQUACY WITH CALCS FOR DESIGN | | | PRESSURES AT OPENINGS. | | | | | | 5- STORM SHUTTERS: A) REVISE MIN. PANEL | | | SIZE. SEE ENGINEERED DRAWINGS | | | LIMITATIONS ACCORDING TO THE MOUNTING | | | CONDITIONS. | | | | | | B) REVISE HEIGHT FOR OPENINGS #13 AND | | | #14. SEE PLANS FOR OPENINGS. | | | NOTE: CHECK FOR MAX. PANEL SPAN. | | | | | | C) REVISE DESIGN PRESSURES FOR OPENING | | | #13. SEE PLANS. | | | NOTE: CHECK FOR MAX. PANEL SPAN. | | | | | | 6- DADE COUNTY NOA REPORT FOR CASEMENT | | | WINDOWSDOESN'T MATCH NOA SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. RESUBMIT | | | CORRECT ONE. | | | | | | 7- DADE COUNTY NOA REPORT FOR CONCRETE | | | LINTELS DOESN'T MATCH ONE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. RESUBMIT | | | CORRECT ONE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-31 |
Time |
11:39 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-01-31 |
Time |
11:39 |
Sent To |
PC |
|
| Notes |
| 2005-01-31 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE BATHROOM WITH DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2- SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SEC. | | | 1609.4.3 FBC 2001. | | | | | | 4- A) NEED NAME OF ARCHITECT SEALING THE | | | PLANS. CHAPTER 61G1-16004 F.A.C. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE DETAIL/SPECS FOR | | | INSTALLATION OF CEILING AT ENTRY AND | | | REAR PORCH. SPECIFY FASTENER SIZE AND | | | SPACING. SEE ASTM C-926 AND ASTM C-1063. | | | SEC. 2504.2 FBC 2001. | | | | | | 6- OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS. | | | | | | 7- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS. SEE SIZE ON PLANS. | | | B) FRENCH DOORS. SEE PLANS. | | | C) CONCRETE LINTELS: NEED THE SAME DADE | | | COUNTY NOA SUBMITTED FOR FLORIDA PRODUCT | | | APPROVAL. | | | D) FIXE WINDOWS THAT MEET THE DESIGN | | | PRESSURES AND SIZES SHOWN ON PLANS. | | | E) ARABESQUE WINDOW SHOWN ON PLANS. | | | | | | 8 A) PROVIDE UL LISTING AND SPECS FOR | | | FIREPLACE. SEC. 2806 FBC 2806 FBC 2001. | | | B) PROVIDE COMPLETE APPROVED BBQ SPECS. | | | SECTION 2808 FBC 2001. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISE MIN. PANEL SIZE. SEE | | | ENGINEERED DRAWINGS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SECTION 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- OWES $866.23 FOR UPDATED VALUATION | | | AND RADON FEES. | | | | | | 12- REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE CONNECTORS SPECIFIED ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-20 |
Time |
14:16 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-04-20 |
Time |
14:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-02 |
Time |
09:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-02 |
Time |
09:47 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-09 |
Time |
07:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-09 |
Time |
07:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-02 |
Time |
07:19 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-02 |
Time |
06:50 |
Sent To |
B |
|
| Notes |
| 2005-06-02 00:00:00 | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | | | | 1} INDICATE THE LOCATION OF PANEL | | | "B"&"C". | | | | | | 2} INDICATE LOCATION OF OVERCURRENT | | | PROTECTION FOR PANELS "A" & "B". | | | | | | 3} THE OCP FOR CIRCUITS 11,12 PANEL "A", | | | 12,13,14,15 PANEL "B" IS TOO LARGE FOR | | | THE CONDUCTORS PER 210.16. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
15:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
15:08 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THE | | | MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-15 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-15 |
Time |
15:12 |
Sent To |
E |
|
| Notes |
| 2006-04-15 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-21 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-21 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2006-02-21 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-12 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
18:18 |
Sent To |
P |
|
| Notes |
| 2005-12-12 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-06 |
Time |
16:13 |
Sent To |
P |
|
| Notes |
| 2005-09-06 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-08-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-05 |
Time |
14:33 |
Sent To |
E |
|
| Notes |
| 2005-08-05 00:00:00 | TO "BTROBAUGH" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-26 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-26 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
| 2005-05-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:36 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
12:14 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
13:47 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
13:47 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-09-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-13 |
Time |
13:32 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-09-13 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
| 2005-09-13 00:00:00 | RE-STAMP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-07 |
Time |
18:09 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-06-07 |
Time |
18:09 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
18:22 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
18:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
17:53 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|