Plan Review Details - Permit 04121890
Plan Review Stops For Permit 04121890
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-09-19 Cont ID  
Sent By jgomez Date 2005-09-16 Time 16:44 Rev Time 1.50
Received By jgomez Date 2005-09-16 Time 16:44 Sent To PC
Notes
2005-09-16 00:00:00BUILDING REVIEW PROVISO:
 1- SHUTTERS UNDER A SEPARATE PERMIT.
 2- IF INSTALLING BBQ, THEN NEED TO
 PROVIDE COMPLETE INFORMATION UNDER A
 SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-08-18 Cont ID  
Sent By jgomez Date 2005-08-18 Time 10:37 Rev Time 2.00
Received By jgomez Date 2005-08-18 Time 10:37 Sent To PC
Notes
2005-08-18 00:00:00BUILDING REVIEW THIRD CHECKLIST:
 1- DESIGNER OF RECORD TO SPECIFY IN THE
 DWGS THE ROOF TILE FASTENING AS REQ'D BY
 SEC. 104.2.1.1 CITY AMENDMENTS TO FBC
 2001. IT'S THE DESIGNER RESPONSIBILITY,
 NOT THE BUILDER.
  
 2- REVISE FASTENERS FOR THD210
 CONNECTOR. SEE TECHNICAL BULLETIN.
  
 3- BBQ WILL NOT BE INSTALLED AT THIS
 TIME. FUTURE INSTALLATION AS MENTIONED
 IN PLANS WILL REQUIRE SEPARATE PERMIT TO
 VERIFY COMPLIANCE OF BBQ SPECS FOR PORCH
 INSTALLATION. SEC. 2808 FBC 2001.
  
 4- CLARIFY IF USING STORM SHUTTERS OR
 IMPACT GLAZING. THERE IS A NOTE THAT
 SHUTTERS UNDER SEPARATE PERMIT, WHILE,
 PRODUCT APPROVAL SUBMITTED FOR CASEMENT
 WINDOWS IS FOR IMPACT WINDOWS. CLARIFY
 AND PROVIDE COMPLETE CONSISTENT
 INFORMATION FOR EITHER METHOD.
  
 5- OWES $334.26 FOR 2ND SUBMITTAL. NOTE:
 ADDITIONAL RE-SUBMITTAL FEES WILL APPLY.
  
 6- NOC WAS RE-RECORDED ON 5-20-05. MAY
 NEED TO BE RE-RECORDED AFTER 90 DAYS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2005-06-08 Cont ID  
Sent By jgomez Date 2005-06-08 Time 09:35 Rev Time 2.00
Received By jgomez Date 2005-06-08 Time 09:35 Sent To PC
Notes
2005-06-08 00:00:00BUILDING REVIEW CHECKLIST:
  
 1- DESIGNER OF RECORD TO SPECIFY ROOF
 TILE FASTENING AS REQUIRED BY SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 2- USP CONNECTOR THD210 AND THD210-2 IS
 A WOOD TO WOOD CONNECTOR. NEED MASONRY
 CONNECTOR. SEE CATALOGUE FOR PROPER
 MASONRY CONNECTOR AND REVISE AS REQUIRED
  
 3- BBQ INFORMATION SUBMITTED WILL BE
 FORWARDED TO BUILDING OFFICIAL FOR
 APPROVAL.
 NOTE: THERE ARE SOME COMPANIES WHO HAVE
 BBQ'S SPECIFICALLY DESIGNED FOR PORCHES
 OR LANAIS. THEY REQUIRE EXHAUST HOOD.
 BUILDING OFFICIAL MAY ASK FOR ADDITIONAL
 INFORMATION OR TESTING TO SUPPORT
 ALFRESCO GRILLS' LETTER STATEMENT THAT
 HOOD IS NOT REQUIRED. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
  
 4- WINDOW MULLIONS: CLEARLY SPECIFY
 MULLION SIZE AND ANCHORS TO BE USED TO
 VERIFY ADEQUACY WITH CALCS FOR DESIGN
 PRESSURES AT OPENINGS.
  
 5- STORM SHUTTERS: A) REVISE MIN. PANEL
 SIZE. SEE ENGINEERED DRAWINGS
 LIMITATIONS ACCORDING TO THE MOUNTING
 CONDITIONS.
  
 B) REVISE HEIGHT FOR OPENINGS #13 AND
 #14. SEE PLANS FOR OPENINGS.
 NOTE: CHECK FOR MAX. PANEL SPAN.
  
 C) REVISE DESIGN PRESSURES FOR OPENING
 #13. SEE PLANS.
 NOTE: CHECK FOR MAX. PANEL SPAN.
  
 6- DADE COUNTY NOA REPORT FOR CASEMENT
 WINDOWSDOESN'T MATCH NOA SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL. RESUBMIT
 CORRECT ONE.
  
 7- DADE COUNTY NOA REPORT FOR CONCRETE
 LINTELS DOESN'T MATCH ONE SUBMITTED FOR
 FLORIDA PRODUCT APPROVAL. RESUBMIT
 CORRECT ONE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-31 Cont ID  
Sent By jgomez Date 2005-01-31 Time 11:39 Rev Time 2.00
Received By jgomez Date 2005-01-31 Time 11:39 Sent To PC
Notes
2005-01-31 00:00:00BUILDING REVIEW CHECKLIST:
 1- PROVIDE COMPLETE BATHROOM WITH DOOR
 THAT ALLOWS 29" MIN. CLEAR OPENING.
 SECTION 11-11 FBC 2001.
  
 2- SPECIFY ROOF TILE FASTENING. SECTION
 104.2.1.1 CITY AMENDMENTS TO FBC 2001.
  
 3- UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE
 COMPLETE ENGINEERING CALCULATIONS FOR
 TYPE AND NUMBER OF FASTENERS THAT DIFFER
 FROM THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER TO COMPLY WITH SEC.
 1609.4.3 FBC 2001.
  
 4- A) NEED NAME OF ARCHITECT SEALING THE
 PLANS. CHAPTER 61G1-16004 F.A.C.
 B) STATE REGISTRATION NUMBER IS
 INCORRECT. REVISE AS REQUIRED.
  
 5- PROVIDE COMPLETE DETAIL/SPECS FOR
 INSTALLATION OF CEILING AT ENTRY AND
 REAR PORCH. SPECIFY FASTENER SIZE AND
 SPACING. SEE ASTM C-926 AND ASTM C-1063.
 SEC. 2504.2 FBC 2001.
  
 6- OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS.
  
 7- PROVIDE FLORIDA OR LOCAL PRODUCT
 APPROVAL FOR:
 A) ENTRY DOORS. SEE SIZE ON PLANS.
 B) FRENCH DOORS. SEE PLANS.
 C) CONCRETE LINTELS: NEED THE SAME DADE
 COUNTY NOA SUBMITTED FOR FLORIDA PRODUCT
 APPROVAL.
 D) FIXE WINDOWS THAT MEET THE DESIGN
 PRESSURES AND SIZES SHOWN ON PLANS.
 E) ARABESQUE WINDOW SHOWN ON PLANS.
  
 8 A) PROVIDE UL LISTING AND SPECS FOR
 FIREPLACE. SEC. 2806 FBC 2806 FBC 2001.
 B) PROVIDE COMPLETE APPROVED BBQ SPECS.
 SECTION 2808 FBC 2001.
  
 9- STORM SHUTTERS: A) KEY PLAN DOESN'T
 MATCH PLANS.
 B) REVISE MIN. PANEL SIZE. SEE
 ENGINEERED DRAWINGS.
 C) REVISE INTERIOR AND END ZONES. SEE
 PLANS.
 D) REVISE DESIGN PRESSURES. SEE PLANS.
  
 10- PROVIDE COMPLETE FRAMING DETAILS FOR
 ARABESQUE WINDOW. SECTION 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
  
 11- OWES $866.23 FOR UPDATED VALUATION
 AND RADON FEES.
  
 12- REVISE FOUNDATION NOTE #2 ON SHEET
 A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER
 ACI REFERENCE.
  
 13- REVISE CONNECTORS SPECIFIED ON
 DETAIL 2/A-9. "SEMCO" IS OUT OF
 BUSINESS
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT (561)805-6712.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-04-20 Cont ID  
Sent By btrobaug Date 2006-04-20 Time 14:16 Rev Time 0.33
Received By btrobaug Date 2006-04-20 Time 14:10 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-03-02 Cont ID  
Sent By btrobaug Date 2006-03-02 Time 09:47 Rev Time 0.50
Received By btrobaug Date 2006-03-02 Time 09:47 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-09 Cont ID  
Sent By btrobaug Date 2005-08-09 Time 07:52 Rev Time 0.50
Received By btrobaug Date 2005-08-09 Time 07:34 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-02 Cont ID  
Sent By btrobaug Date 2005-06-02 Time 07:19 Rev Time 0.50
Received By btrobaug Date 2005-06-02 Time 06:50 Sent To B
Notes
2005-06-02 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
  
 1} INDICATE THE LOCATION OF PANEL
 "B"&"C".
  
 2} INDICATE LOCATION OF OVERCURRENT
 PROTECTION FOR PANELS "A" & "B".
  
 3} THE OCP FOR CIRCUITS 11,12 PANEL "A",
 12,13,14,15 PANEL "B" IS TOO LARGE FOR
 THE CONDUCTORS PER 210.16.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-01-07 Cont ID  
Sent By btrobaug Date 2005-01-07 Time 15:08 Rev Time 0.50
Received By btrobaug Date 2005-01-07 Time 15:08 Sent To M
Notes
2005-01-07 00:00:00 
  
 .PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE OVERCURRENT PROTECTION FOR AHU
 #2 AT 60 AMPS IS TOO LARGE TO PROTECT A
 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30
 AMP OCP). ALSO 60 AMP OCP SHOWN INTHE
 MAIN PANEL SEEM TOOLARGE FOR THE
 CONDENSING UNIT. SEE ARTICLE 440.22
 NEC.
  
 2} THERE ARE NO PROVISIONS IN THE
 CALCULATIONS FOR POOL EQUIPMENT, BUT
 THERE IS EQUIPMENT SHOWN ON THE PLAN.
  
 3} IF NOTE #15 IS ADHERED TO, THOSE
 CIRCUITS WOULD HAVE TO BE PROTECTED BY
 AN AFCI BECAUSE THE DETECTORS ARE
 LOCATED IN BEDROOMS. 210.12.
  
 4} THE GFI'S SHOWN IN THE DINING ROOM
 AND BREAKFAST NOOK, WHILE NOT REQUIRED
 ALTHOUGH PERMISSIBLE, MUST BE INSTALLED
 IF LEFT ON THE PLAN.
  
 5} A RECEPTACLE NEEDS TO BE ADDED TO
 THE
 MASTER BEDROOM TO COMPLY WITH
 210.52(A).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-04-15 Cont ID  
Sent By adarroug Date 2006-04-15 Time 15:12 Rev Time 0.00
Received By adarroug Date 2006-04-15 Time 15:12 Sent To E
Notes
2006-04-15 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-02-21 Cont ID  
Sent By adarroug Date 2006-02-21 Time 08:38 Rev Time 0.00
Received By adarroug Date 2006-02-21 Time 08:38 Sent To E
Notes
2006-02-21 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-12-12 Cont ID  
Sent By adarroug Date 2005-12-12 Time 18:18 Rev Time 0.00
Received By adarroug Date 2005-12-12 Time 18:18 Sent To P
Notes
2005-12-12 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-06 Cont ID  
Sent By adarroug Date 2005-09-06 Time 16:13 Rev Time 0.00
Received By adarroug Date 2005-09-06 Time 16:13 Sent To P
Notes
2005-09-06 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-08-05 Cont ID  
Sent By adarroug Date 2005-08-05 Time 14:33 Rev Time 0.00
Received By adarroug Date 2005-08-05 Time 14:33 Sent To E
Notes
2005-08-05 00:00:00TO "BTROBAUGH" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-26 Cont ID  
Sent By adarroug Date 2005-05-26 Time 08:46 Rev Time 0.00
Received By adarroug Date 2005-05-26 Time 08:46 Sent To E
Notes
2005-05-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-06 Cont ID  
Sent By mjacobs Date 2005-01-06 Time 07:36 Rev Time 0.00
Received By mjacobs Date 2005-01-06 Time 07:36 Sent To E
Notes
2005-01-06 00:00:00TO "SFD" RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-01-03 Cont ID  
Sent By mjacobs Date 2005-01-03 Time 12:14 Rev Time 0.00
Received By mjacobs Date 2005-01-03 Time 12:14 Sent To Z
Notes
2005-01-03 00:00:00TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-01-11 Cont ID  
Sent By prafter Date 2005-01-11 Time 13:47 Rev Time 0.45
Received By prafter Date 2005-01-11 Time 13:47 Sent To B
Notes
2005-01-11 00:00:00NO A/C PLANS.
 PAT RAFTER 561/805/6725 OR 805/6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-09-13 Cont ID  
Sent By jleech Date 2005-09-13 Time 13:32 Rev Time 0.25
Received By jleech Date 2005-09-13 Time 13:32 Sent To B
Notes
2005-09-13 00:00:00RE-STAMP

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-06-07 Cont ID  
Sent By jleech Date 2005-06-07 Time 18:09 Rev Time 0.25
Received By jleech Date 2005-06-07 Time 18:09 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-10 Cont ID  
Sent By jleech Date 2005-01-10 Time 18:22 Rev Time 0.33
Received By jleech Date 2005-01-10 Time 18:22 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-01-05 Cont ID  
Sent By mmclean Date 2005-01-05 Time 17:53 Rev Time 0.00
Received By mmclean Date 2005-01-05 Time 17:53 Sent To I
Notes
2005-01-05 00:00:00MUST PULL SEPERATE PERMIT FOR POOL/DECK