| Plan Review Stops For Permit 04121884 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-10 |
Time |
19:22 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-11-10 |
Time |
19:22 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | STORM SHUTTERS REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-29 |
Time |
15:10 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-04-29 |
Time |
15:10 |
Sent To |
PC |
|
| Notes |
| 2005-04-29 00:00:00 | BUILDING REVIEW PROVISO: | | | 1- DESIGNER OF RECORD TO SPECIFY ROOF | | | TILE FASTENING AS REQUIRED BY SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | 2- CLARIFY WHERE IS THE BASIC VELOCITY | | | PRESSURE TAKEN FROM. THERE ARE NOT | | | TABLES SHOWN IN CHAPTER 16 FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-11 |
Time |
15:09 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-03-11 |
Time |
15:09 |
Sent To |
PC |
|
| Notes |
| 2005-03-11 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- MISSING SHEET A-4. | | | THERE ARE 2 A-5 SHEETS. ONE OF THE IS | | | FOR A 2 STORY HOUSE. | | | THERE ARE 2 CV-1 SHEETS. PROVIDE ONLY | | | ONE PER SET. | | | | | | 2- UPDATE TRUSS ANCHOR SCHEDULE TO MATCH | | | CAPACITY AND TYPE & NUMBER OF FASTENERS | | | AS SHOWN ON FLORIDA PRODUCT APPROVAL | | | PACKAGE. OR PROVIDE COMPLETE ENGINEERING | | | ANALYSIS AND CALCULATIONS THAT COMPLY | | | WITH SECTION 1609.4.3 FBC 2001. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) USP TRUSS ANCHORS SPECIFIED ON PLANS. | | | | | | B) ENTRY DOORS WITH SIZE AND DIRECTION | | | OF SWING AS SHOWN ON PLANS. AND EXACT | | | SAME DRAWINGS THAT WERE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | NEED SOLID DOOR OR IMPACT GLAZING | | | BECAUSE DOOR IS TO BE USED FOR EMERGENCY | | | EGRESS. SEC. 1005.4.5 FBC 2001. | | | | | | C) FRENCH DOORS WITH SIZE AND SWING | | | DIRECTION AS SHOWN ON PLANS. AND WITH | | | EXACT SAME DRAWINGS THAT WERE SUBMITTED | | | FOR FLORIDA PRODUCT APPROVAL. | | | | | | D) CASEMENT WINDOWS WITH EXACT SAME | | | DRAWINGS THAT WERE SUBMITTED FOR FLORIDA | | | PRODUCT APPROVAL. | | | | | | 4- DELETE BBQ AND FIREPLACE FROM | | | DRAWINGS IF OPTION IS NOT GOING TO BE | | | BUILT OR PROVIDE COMPLETE INFORMATION | | | FOR THEM AS REQUIRED BY SEC. 2806 AND | | | 2808 FBC 2001. | | | | | | 5- STORM SHUTTERS: A) BOTH COPIES NEED | | | TO HAVE ORIGINAL SEAL, SIGNATURE AND | | | DATE AS REQUIRED BY ENGINEER ON NOTE #6. | | | | | | B) SOME PANELS EXCEED MAX. PANEL SPAN | | | ACCORDING TO THE DESIGN PRESSURES. SEE | | | ENGINEERED DRAWINGS AND REVISE AS | | | REQUIRED. | | | | | | C) CLEARLY MARK ON ENGINEERED DRAWINGS | | | THE SPECIFIC ANCHOR TYPE AND SPACING TO | | | BE USED ACCORDING TO THE EDGE DISTANCE, | | | PANEL SPAN, DESIGN PRESSURES, CONNECTION | | | TYPE AND STRUCTURE TO BE ATTACHED TO | | | (MASONRY OR 2500PSI CONCRETE). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-25 |
Time |
09:22 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-01-25 |
Time |
09:22 |
Sent To |
PC |
|
| Notes |
| 2005-01-25 00:00:00 | CHECKLIST: | | | 1-PROVIDE COMPLETE BATHROOM WITH A DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2-SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3-UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4- A) TITLE BLOCK NEEDS NAME OF | | | ARCHITECT SEALING THE PLANS. SEE CHAPTER | | | 61G1-16004 OF F.A.C. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5-PROVIDE COMPLETE DETAIL/SPECS FOR | | | INSTALLATION OF CEILING AT ENTRY AND | | | REAR PORCH. SPECIFY ALL FASTENERS AND | | | SPACING. SEE ASTM C926 AND ASTM C1063. | | | SEC. 2504.2 FBC 2001. | | | | | | 6-OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS. | | | | | | 7-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS. SEE SIZE ON PLANS. | | | B) FRENCH DOORS. SEE SIZE ON PLANS. | | | C) CONCRETE LINTELS: NEED DADE COUNTY | | | NOA THAT MATCHES ONE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE DESIGN | | | PRESSURES CALCULATED ON PLANS. SEE PLANS | | | FOR SIZE AND LOCATION. | | | E) ARABESQUE WINDOW AS SHOWN ON PLANS. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. SEC. 2806 FBC | | | 2001. | | | B) PROVIDE APPROVED BBQ SPECS. SECTION | | | 2808 FBC 2001. | | | | | | 9-STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISED MIN. PANEL SIZE. SEE | | | ENGINEERED DRAWINGS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11-OWES $866.23 FOR UPDATED VALUATION. | | | | | | 12-REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE CONNECTORS SPECIFIED ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-07 |
Time |
17:12 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-11-07 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2005-11-07 00:00:00 | REDLINED GROUNDING ELECTRODE CONDUCTOR, | | | MIN #2, 250.66,31.15B6, SHOWS #1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-17 |
Time |
11:43 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-17 |
Time |
11:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
15:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
15:03 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THE | | | MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:27 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-17 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-17 |
Time |
16:38 |
Sent To |
E |
|
| Notes |
| 2005-10-17 00:00:00 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-25 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-25 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2005-04-25 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
09:23 |
Sent To |
E |
|
| Notes |
| 2005-02-15 00:00:00 | TO BTROBAUG DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:34 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
10:52 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
16:19 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
16:19 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | ON A/C PLANS. | | | PAT RAFTER561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
18:11 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
18:11 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
17:58 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|