| Plan Review Stops For Permit 04121878 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-09-27 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-09-27 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2005-09-27 00:00:00 | PROVISO | | | | | | 1) STORM PANEL REVISION INDICATES THAT | | | IMPACT RATED WINDOWS AND DOORS WILL BE | | | INSTALLED IN ALL BUT TWO OPENINGS. | | | PRODUCT APPROVALS SUBMITTED WITH THE | | | BUILDING PERMIT ARE FOR NON-IMPACT | | | GLAZING. SUBMIT NEW PRODUCT APPROVALS | | | FOR IMPACT GLAZING FOR ALL OPENINGS AS | | | REVISIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-02 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-02 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-18 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-18 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | DENIED | | | | | | 1) NO OPENINGS ARE ALLOWED IN THE WALLS | | | ON THE ZERO LOT LINE SIDE PER FBC TABLE | | | 600. REMOVE THE GARAGE VENT AT ZERO LOT | | | SIDE ON SHEET A3. | | | | | | 2) SPECIFY ONE HOUR FIRE RATED GLASS | | | BLOCK AT ZERO LOT LINE ON FLOOR PLAN. | | | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND LISTING INFORMATION FOR THE ONE HOUR | | | FIRE RATED GLASS BLOCK. | | | | | | 4) THE GLASS BLOCK DETAIL ON A9 | | | INCORRECTLY REFERENCES ASCE 7-88. THE | | | CORRECT REFERENCE IS ASCE 7-98. | | | | | | 5) CHAPTER 11 OF THE 2001 FBC REQUIRES | | | AT LEAST ONE FULL BATHROOM WITH A DOOR | | | THAT HAS A 29" CLEAR OPENING. | | | | | | 6) DETAIL 2 ON A9 SPECIFIES "SEMCO" | | | TRUSS CONNECTORS. SEMCO IS NO LONGER IN | | | BUSINESS AND DOES NOT HAVE STATE PRODUCT | | | APPROVAL. | | | | | | 7) SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND LISTING INFORMATION FOR THE BBQ AND | | | PREFAB FIREPLACE. | | | | | | 8) THE OWNER/AGENT IS REQUIRED TO SIGN | | | THE ENERGY CALCULATION FORM PER FBC | | | CHAPTER 13. | | | | | | 9) THE KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS HAS AN | | | EXTRA WINDOW THAT IS NOT SHOWN ON THE | | | PLANS. THE SINGLE FRENCH DOOR IS SHOWN | | | AS A DOUBLE DOOR ON THE KEY PLAN. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-26 |
Time |
18:56 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-08-26 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2005-08-26 00:00:00 | ***** REDLINED ***** | | | | | | 1) MISSING THE REQUIRED DEDICATED | | | BATH(S) CIRCUIT(S). MUST BE 20A, #12, | | | 210.52D,210.11C3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
05:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE SEE A GFI IS SHOWN, HOWEVER THIS | | | APPEARS TO BE FOR LAV.? | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE MISSING GFI IN BATH | | | RM REQUIRED PER 210.52D. | | | | | | 8)NOTE: PLEASE SEE MISSING RECEPT | | | REQUIED ALONG KITCHEN COUNTERSPACE. | | | 210.52C1 | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-28 |
Time |
10:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-28 |
Time |
10:44 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
15:47 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
15:45 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #14 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
09:13 |
Sent To |
B |
|
| Notes |
| 2005-09-27 00:00:00 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-23 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-23 |
Time |
18:38 |
Sent To |
E |
|
| Notes |
| 2005-08-23 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:50 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "TROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-24 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-24 |
Time |
12:59 |
Sent To |
E |
|
| Notes |
| 2005-02-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-23 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:43 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
12:05 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
15:48 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-01 |
Time |
18:21 |
Rev Time |
0.45 |
| Received By |
kstevens |
Date |
2005-03-01 |
Time |
18:21 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-11 |
Time |
11:41 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-01-11 |
Time |
11:41 |
Sent To |
M |
|
| Notes |
| 2005-01-11 00:00:00 | DENIED; | | | 1.TUB IN BATH 3 IS NOT VENTED. WET VENT | | | SHALL BE UPSTREAM OF THE WATER CLOSET. | | | 2.PLEASE CHANGE PLUMBING NOTE 3 TO | | | COMPLY WITH FBC PLUMBING TABLE 704.1. | | | 3.PLEASE DELETE PLUMBING NOTE 6. A/C | | | CONDENSATE IS NOT PERMIITED TO DRAIN | | | INTO THE SEWER SYSTEM. THIS WATER | | | DOESNOT NEED TO BE TREATED. | | | 4.LAUNDRY TRAY TO DRAIN ABOVE CLOTHS | | | WASHER AND THE C.O. SHALL BE 58" OFF | | | FINISH FLOOR. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:22 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|