| Plan Review Stops For Permit 04121872 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-03-14 |
Time |
12:42 |
Rev Time |
1.33 |
| Received By |
alange |
Date |
2005-03-14 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-20 |
Time |
11:05 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-01-20 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | DENIED | | | | | | 1.BASED ON SBCCI BUILDING VALUATION | | | DATA THE VALUE HAS BEEN CHANGED TO | | | $335,607.ADDITIONAL PERMIT FEES OF | | | $955.15 ARE DUE. | | | SEE APPLICATION FOR COST BREAKDOWN. | | | | | | 2.PLEASE SIGN OWNER/AGENT ON ENERGY | | | CALCS. | | | | | | 3.FOOTING DETAILS:THESE DETAILS | | | SHOW A 12" DEEP FOOTING WITH A GRADE OF | | | "APPROXIMATLY" 4".THESE ARE BOTH OK, | | | THEY ARE BOTH MINIMUMS AND THIS LEAVES | | | NO ROOM FOR ERROR OF GRADE. | | | PLEASE REMOVE "APPROXIMATE" FROM PLANS | | | AND SHOW AS "MINIMUM" GRADE 4" FROM | | | FINISH FLOOR.WPB AMMENDMENT TO THE | | | FBC | | | 1804.1.7 | | | | | | NOTE: WHEN SUBMITTING PRODUCT APPROVALS | | | PLEASE MAKE TWO COMPLETE SETS. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-14 |
Time |
13:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-14 |
Time |
12:43 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-22 |
Time |
14:26 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-11-22 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | ***** UNSAT ***** | | | | | | 1)NOTE: PLEASE SEE MAIN SERVICE IS NOW | | | SHOWN AS 400A'S, PLEASE SEE MIN SIZE FOR | | | GROUNDING ELECTRODE PER 250.66, 1/0 MIN. | | | 310.15B6 | | | | | | 2)NOTE: PLEASE SEE SEE AHU'S #2 AND #3, | | | WHICH ARE BOTH SHOWN AS 5KW HEAT WITH | | | 60A OCP? | | | PLEASE SEE MAX 150% OR MANUFACTURE | | | NAMEPLATE. PLEASE KNOW, IN EITHER CASE | | | 60A OCP IS TOO HIGH FOR A 5KW UNIT. | | | ** PLEASE ALSO VERIFY THE #6 SHOWN AS | | | CONDUCTORS ? | | | | | | 3)NOTE: PLEASE SEE SINGLE GARAGE IS | | | STILL SHOWN AS A THREE-CAR | | | GARAGE(MISPIRNT). | | | | | | 4)NOTE: PLEASE CORRELATE LOADS INDICATED | | | FOR MICRO, DISH, DISP. WITH LOADS ON | | | PANEL SCHEDULES. | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE PANEL SCHEDULE "A" | | | SHOWS A DISHWASHER ON A 2-POLE BRKR. | | | PLEASE SEE THIS SEEMS TO BE A MISPRINT | | | AND MAY ALSO BE FOR THE DISPOSAL? | | | PLEASE ALSO UPDATE THE CIRCUIT #'S, IF | | | 2-POLE,,, ETC. | | | | | | 5)NOTE: PLEASE SEE MISSING GFI RECEPT IN | | | KITCHEN PER 210.52C1. PLEASE SEE | | | COUNTERSPACE IS OVER 12" WHICH WOULD | | | REQUIRE ONE MIN. | | | 210.8A6 | | | | | | PLEASE SUBMIT THE ABVOE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
06:37 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: PLEASE SEE PANEL SCHEDULES | | | INDICATE TWO AHU/A/C #2 SYSTEMS. | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | PLEASE SEE SOME MODELS SHOW THESE AS | | | "OPT". EACH PLAN MUST REFLECT THE ACTUAL | | | INSTALLATION PER WHICH ARE INSTALLED OR | | | NOT INSTALLED. | | | 215.5 | | | | | | 7)NOTE: | | | | | | 8)NOTE: | | | | | | 9)NOTE: PLEASE SEE PLANS SHOWS A | | | THREE(3) CAR GARAGE FOR GOLF CART | | | GARAGE? MISPRINT. | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-08 |
Time |
08:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-03-07 |
Time |
18:59 |
Sent To |
B |
|
| Notes |
| 2005-03-07 00:00:00 | IN FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-07 |
Time |
12:58 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-07 |
Time |
12:58 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE 210.52C1 FOR KITCHEN | | | COUNTERSPACE GFI RECEPTS. | | | | | | 2)NOTE: PLEASE SEE HI-HAT LOAD SHOWN AT | | | 48.0KW. PLEASE SEE 64@75W EACH. | | | PLEASE SEE THIS MAY AFFECT SIZE OF | | | SERVICE. | | | | | | 3)NOTE: PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR PER 310.15B6, | | | 250.66 | | | #2 MIN. (IFF 300A SERVICE REMAINS. ) | | | | | | 4)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATESBRKFST NOOK AS GFI. THIS IS | | | NOT REQUIRED,, YET PERMITTED. IF SHOWN | | | ON PLANS THEN THIS IS REQUIRED TO BE | | | DONE. | | | | | | 5)NOTE: PLEASE CORRELATE RISER WITH | | | PLANS. PLANS INDICATE METER/MAIN ON | | | OUTSIDE OF HOUSE, PANEL IN GARAGE AND | | | PANEL IN LAUNDRY RM? | | | 215.5 | | | | | | | | | 6)NOTE: PLEASE SEE OCP IS NOT CLEAR ON | | | PANEL SCHEDULE/LOAD CALCS FOR AHU 5KE | | | HEAT. APPEARS TO BE 50A? | | | PLEASE SEE 424.3B 125% MIN AND 150% | | | USUALLY MAX. IS THIS 30A OCP? | | | PLEASE ALSO SEE RISER SHOWS 60A OCP FOR | | | COND UNITS. PLEASE VERIFY THE OCP WITH | | | MECH PLANS FOR SIZE OF CU. | | | | | | 7)NOTE: PLEASE SEE 210.52 FOR RECEPT | | | LOCATIONS MISSING ON PLANS. BEDRM #2, | | | #3, AND DEN. | | | | | | 8)NOTE: PLEASE SEE PLANS INDICATE POOL | | | EQUIPMENT, YET THIS IS NOT ON PANEL | | | SCHEDULE. IF "FUTURE" PLEASE JUST PLACE | | | NOTE ON PLANS FOR "FUTURE". | | | | | | PLEASE SEE ALL OF THESE ABOVE ITEMS HAVE | | | BEEN REDLINED ON ONE SET OF PLANS FOR | | | AREAS OF CONCERN. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE COPY OF OLD SET MAY BE SUBMITTED FOR | | | REFERENCE ONLY. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
| 2005-11-17 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:16 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-22 |
Time |
15:18 |
Sent To |
E |
|
| Notes |
| 2005-04-22 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-07 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
15:59 |
Sent To |
E |
|
| Notes |
| 2005-03-07 00:00:00 | TO DPALMER DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:14 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-01-03 |
Time |
12:02 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
12:44 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
12:44 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 8056719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-11 |
Time |
10:34 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-11 |
Time |
10:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:47 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|