| Plan Review Stops For Permit 04121866 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-11-10 |
Time |
19:59 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-11-10 |
Time |
19:59 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | STORM SHUTTERS REVISION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-09-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-09-23 |
Time |
17:44 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2005-09-23 |
Time |
17:44 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-08-24 |
Time |
16:06 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2005-08-24 |
Time |
16:05 |
Sent To |
E |
|
| Notes |
| 2005-08-24 00:00:00 | SUBMITTAL BUILDING REVIEW CHECKLIST: | | | | | | 1- REVISE ANCHOR FASTENERS FOR THD210. | | | SEE TECHNICAL BULLETIN FOR TESTED | | | FASTENERS. | | | | | | 2- SPECIFY ROOF TILE FASTENING AS | | | REQUIRED BY SEC. 104.2.1.1 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-04-29 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2005-04-29 |
Time |
11:25 |
Sent To |
PC |
|
| Notes |
| 2005-04-29 00:00:00 | BUILDING REVIEW PROVISO: | | | NOTE: PROVIDE INFORMATION PRIOR TO | | | INSTALLATION OR CONSTRUCTION TO AVOID | | | DELAYS OR CONFLICTS. | | | | | | 1- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR FRENCH DOORS WITH SIDELITES | | | ASSEMBLY AS SHOWN ON PLANS. SIZE OF | | | DOORS SUBMITTED IS NOT THE SAME SIZE AS | | | SHOWN ON PLANS. | | | | | | 2- DESIGN PARAMETERS: CLARIFY WHERE IS | | | THE BASIC VELOCITY PRESSURE TAKEN FROM. | | | THERE IS NOT SUCH INFORMATION GIVEN ON | | | CHAPTER 16 FBC 2001. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-10 |
Time |
15:27 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2005-03-10 |
Time |
15:27 |
Sent To |
PC |
|
| Notes |
| 2005-03-10 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- FLOOR PLAN AND REAR ELEVATION DON'T | | | MATCH. REVISE TYPE OF DOORS USED. AND | | | SPECIFYDESIGN PRESSURES FOR FRENCH | | | DOORS. | | | | | | 2- STORM SHUTTERS: | | | A) OPENING #11 EXCEEDS THE MAX. PANEL | | | SPAN ALLOWED. SEE ENGINEERED DRAWINGS. | | | B) CLEARLY MARK ON ENGINEERED DRAWINGS | | | SPECIFIC ANCHOR AND SPACING TO BE USED | | | ACCORDING TO THE DESIGN PRESSURES, EDGE | | | DISTANCE, CONNECTION TYPE, PANEL SPAN | | | AND STRUCTURE TO BE ATTACHED TO (MASONRY | | | OR 2500PSI CONCRETE). | | | **NOTE: SEE PLANS AND CHECK WHEN | | | OPENINGS ARE END OR INTERIOR ZONES. | | | | | | 2- UPDATE/REVISE TRUSS ANCHOR SCHEDULE | | | AND CALCULATIONS IF CAPACITY OF ANCHORS | | | AND NAIL TYPE AND SPACING IS DIFFERENT | | | FROM THAT PUBLISHED IN THE FLORIDA | | | PRODUCT APPROVAL FOR SUCH CONNECTOR. | | | **NOTE: ENGINEER SHALL CONSIDER SECTION | | | 1609.4.3 FBC 2001 WHEN PERFORMING | | | CALCULATIONS. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS (SOLID OR WITH IMPACT | | | GLAZING BECAUSE USED FOR EMERGENCY | | | EGRESS. SEC. 1005.4.5 FBC 2001.). | | | SEE SIZE AND SWING DIRECTION ON PLANS. | | | **NOTE: SUBMITT THE EXACT SAME DRAWINGS | | | THAT WERE SUBMITTED FOR FLORIDA PRODUCT | | | APPROVAL. | | | | | | B) CASEMENT WINDOWS ASSEMBLY AS SHOWN ON | | | BEDROOM #2. SEE PLANS. | | | | | | C) FRENCH DOORS. SEE SIZE AND SWING | | | DIRECTION SHOWN ON PLANS. PROVIDE DWGS | | | SUBMITTED FOR FLORIDA PRODUCT APPROVAL. | | | | | | D) FRENCH DOORS WITH SIDELITES AS SHOWN | | | ON PLANS. PROVIDE EXACT SAME DRAWINGS | | | SUBMITTED FOR FLORIDA PRODUCT APPROVAL. | | | | | | E) USP TRUSS ANCHORS SPECIFIED ON PLANS | | | AND TRUSS ANCHOR SCHEDULE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-26 |
Time |
14:53 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-01-26 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
| 2005-01-26 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE BATHROOM WITH A DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. SEC. | | | 11-11 FBC 2001. | | | | | | 2- SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- UPDATE TRUSS ANCHOR SCHEDULE. PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE & NUMBER OF FASTENERS THAT DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY THE | | | MANUFACTURER TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4- A)TITLE BLOCK NEEDS NAME OF ARCHITECT | | | SEALING PLANS. CHAPTER 61G1-16004 FAC. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE DETAIL/SPECS FOR INSTALLATION | | | OF CEILING AT ENTRY AND REAR PORCHES. | | | SPECIFY FASTENERS AND SPACING. SEE ASTM | | | C926 AND ASTM C1063. SEC. 2504.2 FBC. | | | | | | 6- ENERGY CALCULATIONS: OWNER/AGENT TO | | | SIGN AND DATE FORM. | | | | | | 7-PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A) ENTRY DOORS. | | | B) FRENCH DOORS. SEE SIZES ON PLANS. | | | C) CONCRETE LINTELS: NEED DADE COUNTY | | | NOA THAT MATCHES ONE SUBMITTED FOR | | | FLORIDA PRODUCT APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE DESIGN | | | PRESSURES CALCULATED ON PLANS. SEE PLANS | | | FOR SIZES AND DESIGN PRESSURES. | | | E) ARABESQUE WINDOW AS SHOWN ON PLANS. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. SEC. 2806 FBC. | | | B) PROVIDE COMPLETE APPROVED BBQ SPECS. | | | SEC. 2808 FBC 2001. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISE MINIMUM PANEL SIZE. SEE | | | ENGINEERED DRAWINGS FOR LIMITATIONS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS FOR LOCATION. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARABESQUE WINDOW. SEC. 104.2.1.2 CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- OWES $866.23 FOR UPDATED VALUATION. | | | | | | 12- REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE DETAIL CONNECTORS SHOWN ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-14 |
Time |
11:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-14 |
Time |
11:20 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-22 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-11-22 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | **** UNSAT **** | | | | | | | | | 1)NOTE: PLEASE SEE 250.66,310.15B6 FOR | | | MIN SIZE OF THE GROUNDING ELECTRODE | | | CONDUCTOR. | | | ** PLEASE SEE SERVICE NOW INCREASED FROM | | | 300A TO 400A'S. | | | | | | 2)NOTE: PLEASE SEE AHU#2 ON PANEL "B" | | | WHICH SHOWS A 5KW UNIT WITH 60A OCP. | | | PLEASE ALSO SEE #6 SHOWN. | | | PLEAS KNOW, THE #6 IS OK, BUT NOT | | | REQUIRED. IF SHOWN AS #6, THEN IT WILL | | | BE REQUIRED. PLEASE SEE THE OCP IS TOO | | | LARGE FOR A 5KWAHU. (MAX | | | 150%/MANUFACTURES NAMEPLATE). | | | | | | 3)NOTE: PLEASE SEE DISH/DISP SHOWN AS | | | 2-POLE, HOWEVER PANEL SCHEDULE ONLY | | | SHOWS A SINGLE SPACE/CIRCUIT ON | | | SCHEDULE.215.5 | | | PLEASE CORRELATE. | | | | | | 4)NOTE: PLEASE SEE MICRO,FRIG,DISH/DISP | | | LOADS ON PANEL SCHEDULE AND NEUTRAL | | | LOADS NEED TO CORRELATE. | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PELASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-24 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-08-24 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | REDLINED GROUNDING ELECTRODE PER 250.66, | | | 310.15B6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-18 |
Time |
12:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-18 |
Time |
11:55 |
Sent To |
B |
|
| Notes |
| 2005-04-18 00:00:00 | | | | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | PLEASE CORRECT AND RESUBMIT THE | | | FOLLOWING CORRECTIONS FOR REVIEW PRIOR | | | TO CALLING A ROUGH ELECTRICAL | | | INSPECTION. | | | | | | 1} PUT ALL PANELS ON THE PLAN AT CORRECT | | | LOCATION. | | | | | | 2} CIRCUITS 12,13 PANEL "A" AND | | | 12,13,14, AND 15, PANEL "B", NEED TO | | | HAVE #12CU FOR THE OCP 20 AMP BREAKER. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-17 |
Time |
12:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-17 |
Time |
12:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
14:19 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THE MASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-17 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
16:26 |
Sent To |
E |
|
| Notes |
| 2005-11-17 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-06 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-06 |
Time |
15:22 |
Sent To |
B |
|
| Notes |
| 2005-09-06 00:00:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-05 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-05 |
Time |
11:00 |
Sent To |
B |
|
| Notes |
| 2005-07-05 00:00:00 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:54 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
08:44 |
Sent To |
E |
|
| Notes |
| 2005-02-15 00:00:00 | TO BTROBAUG DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
07:54 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
12:00 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
13:40 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 8056719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-09-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-09-26 |
Time |
07:32 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-09-26 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
18:45 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
18:45 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
17:32 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|