| Plan Review Stops For Permit 04121854 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-08-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-08-17 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-08-17 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2005-08-17 00:00:00 | REVISED SHEETS A2,A3 AND A6 ARE OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-07-20 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-07-20 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2005-07-20 00:00:00 | REVISED LOCATION OF STRUCTURE ON LOT IS | | | OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-06-29 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-06-29 |
Time |
12:26 |
Sent To |
P |
|
| Notes |
| 2005-06-29 00:00:00 | PROVISO | | | | | | 1) REVISE THE USP ANCHOR SCHEDULE ON | | | SHEET A6 SO THAT THE NUMBER AND SIZE OF | | | MASONRY FASTENERS IS THE SAME AS | | | SPECIFIED ON THE USP TECHNICAL | | | BULLETINS. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS | | | AND LISTING INFORMATION FOR THE BUILT IN | | | BBQ. INCLUDE INSTALLATION INSTRUCTIONS, | | | CLEARANCES, ETC. | | | | | | 3) SUBMIT PRODUCT APPROVALS FOR THE | | | 12'X 8' SLIDING GLASS DOOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-06-06 |
Time |
17:49 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-06-06 |
Time |
17:49 |
Sent To |
E |
|
| Notes |
| 2005-06-06 00:00:00 | BUILDING REVIEW CHECKLIST: | | | | | | 1- NOTE ON DRAWING A-3 CALLS FOR IMPACT | | | GLAZING IN DOORS AND WINDOWS. SHUTTERS | | | INSTALLATION SCHEDULE SHOWSMISSILE | | | IMPACT GLAZING IN DOORS AND WINDOWS. | | | PRODUCT APPROVALS SUBMITTED FOR DOORS | | | AND WINDOWS ARE FOR NON IMPACT GLAZING. | | | NEED TO CLARIFY WHICH METHOD OF GLASS | | | PROTECTION IS GOING TO BE USED AND | | | PROVIDE COMPLETE INFORMATION FOR EITHER | | | METHOD. | | | | | | 2- FRONT ELEVATION TO SHOW EXACT TYPE OF | | | ENTRY DOORS FOR WHICH PRODUCT APPROVAL | | | WILL BE SUBMITTED. | | | | | | | | | 3- REVISED ENERGY CALCULATIONS WERE | | | REQUIRED BECAUSE A/C AREA WAS INCREASED. | | | REVISED ENERGY CALCULATIONS WERE NOT | | | SUBMITTED. | | | | | | 4- TRUSS ANCHOR SCHEDULE: REVISE | | | CONNECTOR THD210 AND THD210-2. THIS IS A | | | WOOD TO WOOD CONNECTOR. NEED A MASONRY | | | TO WOOD CONNECTOR. SEE CATALOGUE FOR | | | PROPER MASONRY CONNECTOR. | | | | | | 5- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: A) FRENCH DOORS THAT MATCH | | | SIZE OF DOORS SHOWN ON PLANS. PRODUCT | | | APPROVAL SUBMITTED IS FOR 6'-8" HIGH | | | DOORS. NEED 8'-0" HIGH DOORS. | | | | | | B) CASEMENT WINDOWS: DADE COUNTY NOA | | | REPORT DOESN'T MATCH REPORT SUBMITTED | | | FOR FLORIDA PRODUCT APPROVAL. RESUBMIT | | | CORRECT DADE COUNTY NOA REPORT. | | | | | | 6- SPECIFICATIONS FOR BBQ WERE FORWARDED | | | TO BUILDING OFFICIAL FOR APPROVAL. BLDG | | | OFFICIAL IS OUT THIS WEEK. | | | NOTE: THERE ARE COMPANIES WHO HAVE | | | DESIGNED BBQ TO BE SPECIFICALLY | | | INSTALLED IN PORCHES OR LANAIS AND THE | | | PACKAGE INCLUDES EXHAUST HOOD. | | | ADDITIONAL INFORMATION OR TESTING MAY BE | | | REQUIRED BY THE BUILDING OFFICIAL TO | | | SUPPORT STATEMENT FROM ALFRESCO GRILLS | | | LETTER. SEC. 104.2.1.2 CITY AMENDMENTS | | | TO FBC 2001. | | | | | | 7- DESIGN PARAMETERS ON SHEET A-3: | | | CLARIFY WHERE IS THE BASIC VELOCITY | | | PRESSURE TAKEN FROM. THERE ARE NOT | | | TABLES REFERENCED IN CHAPTER 16 FBC | | | 2001. (THIS WAS THE STANDARD BUILDING | | | CODE TABLE NOT THE FBC). SEC. 104.2.1.2 | | | CITY AMENDMENTS TO FBC 2001. | | | | | | 8- EXTERIOR ELEVATIONS CALL FOR FLAT | | | CEMENT TILE. PRODUCT APPROVAL SUBMITTED | | | IS FOR "S" TILE. CLARIFY/REVISE AS REQ'D | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-03-11 |
Time |
17:55 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2005-03-11 |
Time |
10:59 |
Sent To |
PC |
|
| Notes |
| 2005-03-10 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- MISSING SHEET A-2. | | | | | | 2- A/C AREA WAS INCREASED. NEED TO BRING | | | DWGS TO THE PALM BEACH COUNTY TO UPDATE | | | INFORMATION AND RE-STAMP DRAWINGS AND | | | PAID RECEIPT. | | | | | | 3- PLANS WERE REVISED ADDING A/C AREA. | | | REVISE THE ENERGY CALCULATIONS | | | ACCORDINGLY. | | | | | | 4- UPDATE/REVISE TRUSS ANCHOR SCHEDULE | | | TO MATCH CAPACITY AND TYPE & NUMBER OF | | | NAILS PUBLISHED ON THE FLORIDA PRODUCT | | | APPROVAL. OTHERWISE, PROVIDE COMPLETE | | | ENGINEERING ANALYSIS AND CALCULATIONS | | | THAT COMPLY WITH SECTION 1609.4.3 FBC | | | WHERE THE STRESS INCREASE IS NO ALLOWED. | | | | | | 5- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) ENTRY DOORS. VERIFY SIZE AND SWING | | | DIRECTION ON PLANS. ALSO, NEED TO BE | | | SOLID OR HAVE IMPACT GLASS IF THIS IS | | | THE DOOR USED FOR EMERGENCY EGRESS AS | | | REQ'D BY SEC. 1005.4.5 FBC 2001. | | | | | | B) FRENCH DOOR. SEE SIZES ON PLANS. | | | | | | 5- SHEET A-3 NOTE CALLS FOR IMPACT | | | GLAZING IN ALL DOORS AND WINDOWS. BUT, | | | STORM SHUTTERS INFORMATION IS SUBMITTED. | | | REVISE PLANS AS REQUIRED TO MATCH | | | PROTECTION OF GLASS BY SHUTTERS OR | | | IMPACT GLASS IN DOORS AND WINDOWS. | | | | | | 6- BBQ SPECS SAY THAT GRILLWAS | | | DESIGNED FOR OUTDOOR USE ONLY & CANN'T | | | BE INSTALLED IN THE BUILDING AND BELOW | | | OVERHEAD UNPROTECTED CONSTRUCTION. | | | PROVIDE CERTIFICATION FROM MANUFACTURER | | | THAT BBQ GRILL WILL BE OK TO INSTALL IN | | | THE PORCH. SEC. 2808 FBC 2001. | | | | | | 7- STORM SHUTTERS: A) ENGINEER'S GENERAL | | | NOTE #6 REQUIRES DRAWINGS TO BE SIGNED, | | | SEALED AND DATED BY HIM. | | | | | | B) THERE ARE SOME PANELS THAT EXCEED | | | MAX. PANEL SPAN ACCORDING TO THE DESIGN | | | PRESSURES. REVISE AS REQUIRED. | | | | | | C) CLEARLY MARK ON ENGINEERED DRAWINGS | | | ANCHOR SCHEDULE SPECIFIC ANCHOR TO BE | | | USED ACCORDING TO THE EDGE DISTANCE, | | | DESIGN PRESSURES, PANEL SPAN, CONNECTION | | | TYPE AND STRUCTURE TO BE ATTACHED TO | | | (MASONRY OR 2500PSI CONCRETE). | | | | | | 8- NOTICE OF COMMENCEMENT EXPIRES AFTER | | | 90 DAYS WITHOUT WORK. NEED RE-RECORDED | | | NOTICE OF COMMENCEMENT. | | | | | | 9- OWES $83.45 FOR INCREASED A/C AREA. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-01-31 |
Time |
16:07 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2005-01-31 |
Time |
16:07 |
Sent To |
PC |
|
| Notes |
| 2005-01-31 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- PROVIDE COMPLETE BATHROOM WITH DOOR | | | THAT ALLOWS 29" MIN. CLEAR OPENING. | | | SECTION 11-11 FBC 2001. | | | | | | 2- SPECIFY ROOF TILE FASTENING. SECTION | | | 104.2.1.1 CITY AMENDMENTS TO FBC 2001. | | | | | | 3- UPDATE TRUSS ANCHOR SCHEDULE. | | | PROVIDE | | | COMPLETE ENGINEERING CALCULATIONS FOR | | | TYPE AND NUMBER OF FASTENERS THAT | | | DIFFER | | | FROM THOSE TESTED AND PUBLISHED BY | | | MANUFACTURER TO COMPLY WITH SECTION | | | 1609.4.3 FBC 2001. | | | | | | 4- A) NEED NAME OF ARCHITECT WHO IS | | | SEALING THE PLANS. CHAPTER 61G1-16004 | | | FAC. | | | B) STATE REGISTRATION NUMBER IS | | | INCORRECT. REVISE AS REQUIRED. | | | | | | 5- PROVIDE COMPLETE DETAIL/SPECS FOR | | | CEILING INSTALLATION AT ENTRY AND REAR | | | PORCHES. SPECIFY FASTENERS SIZE AND | | | SPACING. SEE ASTM C926 AND ASTM C1063. | | | SECTION 2504.2 FBC 2001. | | | | | | 6- OWNER/AGENT TO SIGN AND DATE THE | | | ENERGY CALCULATIONS. | | | | | | 7- PROVIDE FLORIDA OR APPLY FOR LOCAL | | | PRODUCT APPROVAL FOR: | | | A) ENTRY DOORS. | | | B) FRENCH DOORS. | | | C) CONCRETE LINTELS: NEED EXACT DADE | | | COUNTY NOA THAT MATCHES ONE SUBMITTED | | | FOR FLORIDA LOCAL APPROVAL. | | | D) FIXED WINDOWS THAT MEET THE SIZES | | | AND | | | DESIGN PRESSURES SHOWN ON PLANS. | | | E) ARABESQUE WINDOW. SEE PLANS. | | | | | | 8- A) PROVIDE COMPLETE UL LISTING AND | | | SPECS FOR FIREPLACE. SEC. 2806 FBC | | | 2001. | | | B) PROVIDE COMPLETE APPROVED BBQ SPECS. | | | SECTION 2808 FBC 2001. | | | | | | 9- STORM SHUTTERS: A) KEY PLAN DOESN'T | | | MATCH PLANS. | | | B) REVISE MIN. PANEL SIZE. SEE | | | ENGINEERED DRAWINGS FOR LIMITATIONS. | | | C) REVISE INTERIOR AND END ZONES. SEE | | | PLANS. | | | D) REVISE DESIGN PRESSURES. SEE PLANS. | | | | | | 10- PROVIDE COMPLETE FRAMING DETAILS | | | FOR | | | ARABESQUE WINDOW. SECTION 104.2.1.2 | | | CITY | | | AMENDMENTS TO FBC 2001. | | | | | | 11- OWES $866.23 FOR UPDATED | | | CALCULATION. | | | | | | 12- REVISE FOUNDATION NOTE #2 ON SHEET | | | A-2. SEE CHAPTER 19 FBC 2001 FOR PROPER | | | ACI REFERENCE. | | | | | | 13- REVISE CONNECTORS SPECIFIED ON | | | DETAIL 2/A-9. "SEMCO" IS OUT OF | | | BUSINESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT (561)805-6712. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-10 |
Time |
07:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-10 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-14 |
Time |
12:42 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-14 |
Time |
12:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-30 |
Time |
07:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-30 |
Time |
07:01 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-17 |
Time |
11:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-17 |
Time |
10:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-07 |
Time |
14:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-01-07 |
Time |
14:05 |
Sent To |
M |
|
| Notes |
| 2005-01-07 00:00:00 | | | | | | | .PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE OVERCURRENT PROTECTION FOR AHU | | | #2 AT 60 AMPS IS TOO LARGE TO PROTECT A | | | 5KW UNIT.(5000X125%/240=26 AMPS, MAX 30 | | | AMP OCP). ALSO 60 AMP OCP SHOWN INTHE | | | MAIN PANEL SEEM TOOLARGE FOR THE | | | CONDENSING UNIT. SEE ARTICLE 440.22 | | | NEC. | | | | | | 2} THERE ARE NO PROVISIONS IN THE | | | CALCULATIONS FOR POOL EQUIPMENT, BUT | | | THERE IS EQUIPMENT SHOWN ON THE PLAN. | | | | | | 3} IF NOTE #15 IS ADHERED TO, THOSE | | | CIRCUITS WOULD HAVE TO BE PROTECTED BY | | | AN AFCI BECAUSE THE DETECTORS ARE | | | LOCATED IN BEDROOMS. 210.12. | | | | | | 4} THE GFI'S SHOWN IN THE DINING ROOM | | | AND BREAKFAST NOOK, WHILE NOT REQUIRED | | | ALTHOUGH PERMISSIBLE, MUST BE INSTALLED | | | IF LEFT ON THE PLAN. | | | | | | 5} A RECEPTACLE NEEDS TO BE ADDED TO | | | THEMASTER BEDROOM TO COMPLY WITH | | | 210.52(A). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
15:52 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-15 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-15 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2005-08-15 00:00:00 | TO "RMCDOUGAL"DESK/SUBMITTAL | | 2005-07-20 00:00:00 | PER P TJOMSTOL/L MARTINEZ ROUTE TO | | | INCOMING - ZONING HAS APPROVED BLDG | | | STILL NEEDS TO REVIEW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
08:51 |
Sent To |
B |
|
| Notes |
| 2005-06-20 00:00:00 | TO JG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
17:16 |
Sent To |
B |
|
| Notes |
| 2005-05-24 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-15 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-15 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
| 2005-02-15 00:00:00 | TO BTROBAUG DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-06 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-06 |
Time |
08:27 |
Sent To |
E |
|
| Notes |
| 2005-01-06 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
11:50 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-11 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-01-11 |
Time |
13:32 |
Sent To |
B |
|
| Notes |
| 2005-01-11 00:00:00 | NO A/C PLANS. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-29 |
Time |
15:50 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-06-29 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-10 |
Time |
18:34 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-10 |
Time |
18:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-20 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-20 |
Time |
12:29 |
Sent To |
PC |
|
| Notes |
| 2005-07-20 00:00:00 | APPROVED RE-STAMP OF SURVEY, MOVING THE | | | HOUSE ON LOT. GIVEN TO WANDAL, PERMIT & | | | LICENSE SPECIALIST. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-05 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-05 |
Time |
18:44 |
Sent To |
I |
|
| Notes |
| 2005-01-05 00:00:00 | MUST PULL SEPERATE PERMIT FOR POOL/DECK |
|
|