| Plan Review Stops For Permit 04121828 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-10-11 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-10-11 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2006-10-11 15:27:56 | STRUCTURAL REV. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-08 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | STRUCTURAL REV. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-23 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-02-23 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | PROCESSED REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-30 |
Time |
07:04 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-12-30 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-04-26 |
Time |
07:51 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-04-26 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-11 |
Time |
13:46 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2005-02-09 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2005-02-09 00:00:00 | DENIED | | | | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.ENCLOSED SUN ROOM AND EXCERCISE ROOM | | | IS A HABITABLE SPACE. THE LOWEST FINISH | | | FLOOR ELEVATION SHALL BE A MINIMUM OF 4 | | | INCHES ABOVE THE FINISH GRADE. | | | 1804.1.7 WEST PALM BEACH AMMENDMENT TO | | | THE FBC. | | | | | | 3.R - VALUE ON ENERGY CALCS FOR | | | CEILING INSULATION DO NOT MATCH PLANS. | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR FLAT | | | DECK MEMBRANE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.CONTRACTOR REQUIRED TO OBTAIN A | | | PERMIT.FIVE PROPERTIES ARE OWNED BY | | | OWNER BUILDER. SEE FLORIDA STATUTES | | | 489. | | | | | | 6.WHEN REPAIRS AND ALTERATIONS | | | AMOUNTING TO MORE THAN 50% OF THE VALUE | | | OF THE EXISTING BUILDING ARE MADE | | | DURING | | | ANY 12 MONTH PERIOD, THE BUILDING SHALL | | | BE MADE TO CONFORM TO THE QUIREMENTS FOR | | | A NEW BUILDING.PLEASE SHOW ON PLANS | | | HOW EXISTING BUILDING WILL COMPLY. | | | FBC 3401.7.2.6 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-03 |
Time |
14:14 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-03 |
Time |
13:07 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-13 |
Time |
12:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-13 |
Time |
12:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-16 |
Time |
16:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-16 |
Time |
16:13 |
Sent To |
PC |
|
| Notes |
| 2007-02-16 16:22:17 | | | | DENIED/INCOMPLETE INFORMATION | | | | | | THE SHEET THAT WAS SUBMIITED IS DESIGNATED SHEET "2", | | | THE SHEET THAT IT IS REVISING IS "6/8" ON THE ORIGINAL | | | PLAN. ALSO THE REVISION SUBMITTED IS A DIFFERENT SIZE | | | THAN THE ORIGINAL AND MAKES FOR DIFFICULT RECORD | | | RETENTION. YHERE WAS SEVERAL DETAILS MISSING FROM THE | | | REVISED SHEET THAT WERE ON THE ORIGINAL, LIKE PANEL | | | SCHEDULES, LOAD CALC'S, RISER DIAGRAM, ETC. SEE | | | ORIGINAL SET, CLOUD AND MARK WITH A DELTA THE AREAS OF | | | REVISION. 106.1.3 FBC AS AMMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-21 |
Time |
07:48 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-02-21 |
Time |
07:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-23 |
Time |
14:13 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-23 |
Time |
13:48 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-01 |
Time |
11:24 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2005-06-01 |
Time |
11:05 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-29 |
Time |
15:42 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-29 |
Time |
15:42 |
Sent To |
P |
|
| Notes |
| 2005-03-29 00:00:00 | ********** UNSAT ************ | | | | | | PLEASE SEE PLANS WERE ORIGINALLY SET UP | | | FOR "PROVISO", HOWEVER PLANS ARE COMING | | | BACK FOR COMMENTS FROM OTHER | | | REVIEWER(S). | | | PLEASE MAKE CORRECTIONS AT THIS TIME. | | | | | | | | | | | | | | | ******************* | | | | | | 1)NOTE: PLEASE SEE THERE ARE NUMEROUS | | | ITEMS ON ELECTRICAL PANEL SCHEDULE WHERE | | | LOAD EXCEEDS RATING OF OCP AND AWG. | | | PLEASE SEE 2K ON 20A #12, 2KW ON 20A OCP | | | AND ON #14 AWG. | | | | | | 2)NOTE: PLEASE SEE WASHER OS SHOWN AS | | | GAS?, PLEASE VERIFY. | | | | | | 3)NOTE: PLEASE SEE PLANS REFERENCE "CITY | | | OF PALM BEACH COUNTY". PLEASE SEE JOB IS | | | LOCATED IN THE "CITY OF WEST PALM | | | BEACH". | | | | | | | | | PLEASE CORRECT AND REVISE: | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-02-09 |
Time |
13:03 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-02-09 |
Time |
12:19 |
Sent To |
B |
|
| Notes |
| 2005-02-09 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THERE ARE SEVERAL AREAS THAT DO NOT | | | COMPLY WITH THE SPACING REQUIREMENTS OF | | | 210.52, SUN RM, GREAT ROOM, BED ROOM & | | | FAMILY ROOM. SEE REVIEWED PLAN. | | | | | | 2} SMOKE DETECTORS ARE REQUIRED PER | | | ARTICLE 8-1.4.1.6.2 NFPA-72,STAIRS AND | | | MASTER BEDROOM. | | | | | | 3} SEE 210.63 FOR RECEPTACLE @ | | | EQUIPMENT | | | RE: A/C CONDENSOR(S). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-10 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-10 |
Time |
17:16 |
Sent To |
B |
|
| Notes |
| 2008-03-10 17:17:17 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-11 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-11 |
Time |
13:39 |
Sent To |
M |
|
| Notes |
| 2007-05-11 13:39:23 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-02 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-02 |
Time |
17:46 |
Sent To |
E |
|
| Notes |
| 2007-04-02 17:46:14 | TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2007-03-08 11:17:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
08:33 |
Sent To |
E |
|
| Notes |
| 2007-02-16 08:33:19 | TO "BTROBAUGH" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
08:30 |
Sent To |
P |
|
| Notes |
| 2007-02-16 08:31:18 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
16:27 |
Sent To |
M |
|
| Notes |
| 2007-02-15 16:28:10 | TO "M' BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-15 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-15 |
Time |
15:24 |
Sent To |
M |
|
| Notes |
| 2006-12-15 15:24:43 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-01 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-01 |
Time |
13:27 |
Sent To |
M |
|
| Notes |
| 2006-12-01 13:27:56 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-29 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-29 |
Time |
10:10 |
Sent To |
B |
|
| Notes |
| 2006-09-29 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-01 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2006-08-01 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-03 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-03 |
Time |
08:36 |
Sent To |
M |
|
| Notes |
| 2006-02-03 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-20 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-20 |
Time |
10:07 |
Sent To |
E |
|
| Notes |
| 2005-12-20 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
11:20 |
Sent To |
Z |
|
| Notes |
| 2005-12-10 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-09 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-09 |
Time |
18:03 |
Sent To |
Z |
|
| Notes |
| 2005-08-09 00:00:00 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
09:49 |
Sent To |
E |
|
| Notes |
| 2005-05-24 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-17 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-17 |
Time |
14:40 |
Sent To |
Z |
|
| Notes |
| 2005-05-17 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-28 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-28 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2005-03-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-22 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-22 |
Time |
15:42 |
Sent To |
Z |
|
| Notes |
| 2005-03-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-15 |
Time |
16:35 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-15 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2007-05-15 16:35:43 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-20 |
Time |
10:28 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-02-20 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2007-02-20 10:29:18 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-12-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-18 |
Time |
11:18 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-18 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2006-12-18 11:18:47 | REVISION TO MECH. PLANS AND E-CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-12-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-12-04 |
Time |
08:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-12-04 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2006-12-04 08:51:43 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS LINE 13 HEATING SYSTEMS (A) AND | | | (B) ARE CALLING FOR GAS HYDRONIC SPACE & WATER HEATER, | | | PLANS ARE CALLING FOR A 10 KW AND A 5 KW ELECTRIC | | | HEATERS, PLEASE CORRECT ENERGY CALCULATIONS. | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | 3) PLEASE SHOW ON PLANS TOTAL AND SENSIBLE BTU'S. FOR | | | A/C SYSTEMS. | | | | | | 4) RETURN AIR TRANSFER DUCTS TO NEW GYM AND THE TWO | | | EXISTING BEDROOM ON THE FIRST FLOOR ARE TO SMALL. | | | BALANCED RETURN AIR. | | | MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-03 |
Time |
14:43 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-02-03 |
Time |
14:43 |
Sent To |
P |
|
| Notes |
| 2006-02-03 00:00:00 | *** PROVISO *** | | | 1) COVERED PORCH, EXHUST HOOD DUCT MUST | | | BE 10" 16 GAGE STEEL, PER MANF. INST. | | | AND 2001 FBC/M 506.3.1.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-27 |
Time |
08:42 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2005-12-27 |
Time |
08:42 |
Sent To |
P |
|
| Notes |
| 2005-12-27 00:00:00 | *** DENIED *** | | | 1) NEED TO SHOW SIZE OF RETURN AIR GRILL | | | AT AHU, AND IF BIFOLD DOOR IS LOUVERED. | | | | | | 2) BBQ GRILL UNDER COVERED PORCH NEEDS | | | AN APPROVED EXHAUST HOOD OVER IT, PER | | | 2001 FBC/M 505.3 . | | | | | | 3) TRANSFER DUCT FROM NEW GYM IS TO | | | SMALL, PLEASE SEE NOTE 4 . | | | | | | 4) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-11 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-04-11 |
Time |
09:57 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-04-11 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2005-04-11 00:00:00 | SECOND MECH. PLAN REVIEW. | | | | | | ALL SIX ITEMS SATIFIED. | | | | | | PAT RAFTER 805/6728. | | | PLEASE CALL IF THEIR ANY QUESTIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-10 |
Time |
06:49 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-02-10 |
Time |
06:38 |
Sent To |
B |
|
| Notes |
| 2005-02-10 00:00:00 | DENIED: | | | 1.PLAN SHEET A/2 INDICATES A GAS WATER | | | HEATER SHARING THE CLOSET WITH THE AHU. | | | PER 2001 FBC(M)603.9, COMBUSTION WATER | | | HEATERS SHALL NOT BE LOCATED IN | | | MECHANICAL CLOSETS USED AS RETURN AIR | | | PLENUMS. | | | | | | 2.PLAN SHEET A/2 INDICATES A GAS | | | DRYER.PROVIDE CALCULATIONS FOR | | | COMBUSTION AIR IN ACCORDANCE WITH 2001 | | | FBC(M) CHAPTER 7. | | | | | | 3.INDICATE ON THE PLAN METHOD OF | | | MAKE-UP AIR. | | | | | | 4.PROVIDE SUBMITTAL DATA FOR ALL GAS | | | APPLIANCES. | | | | | | 5.PLAN SHEET A/8, PLAN DOES NOT | | | INDICATE ANY RETURN AIR FROM NEW GYM AND | | | SUNROOM AREAS.PLEASE SHOW COMPLIANCE | | | WITH 2001 FBC(M)601.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-08 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2007-03-08 08:38:36 | DENIED; | | | REVISED DRAWINGS MUST BE DRAWN AND SIGNED AND UNDER THE | | | SAME TITLE BLOCK AS ORIGIAL APPROVED PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-21 |
Time |
07:23 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2006-02-21 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-29 |
Time |
07:57 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-29 |
Time |
07:57 |
Sent To |
B |
|
| Notes |
| 2005-12-29 00:00:00 | DENIED | | | 1.SHOW HOW EXISTINGSHOWER DRAIN IS | | | PIPED ON FLAT PLAN AND RISER DIAGRAM. | | | 2.HORIZONTAL DRY VENTS ARE NOT PERMITED, | | | MASTER BATHROOM. | | | 3.AN DEMAND GAS WATER HEATERS MUST BE | | | INSTALLED ON THE OUTSIDE OF BUILDING NOT | | | IN LAUNDRY ROOM AS SHOWN ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-04-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-04-09 |
Time |
08:45 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-04-09 |
Time |
08:45 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-29 |
Time |
16:01 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-02-11 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2005-02-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) CLEANOUTS ARE REQUIRED NEAR THE | | | JUNCTION OF THE BUILDING DRAIN AND THE | | | BUILDING SEWER. SECTION 708.3.5. (SEE | | | THE LINES TO THE MASTER BATH STACK, THE | | | WASH MACHINE AND THE POWDER ROOM/KITCHEN | | | SINK BUILDING DRAIN LINES. | | | 2) ALL DRAWINGS SHALL BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN. SIGNATURE STAMPS ARE NOT | | | ACCEPTABLE. SIGNATURE IS REQUIRED. | | | SECTION 104.2.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-19 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-19 |
Time |
17:40 |
Sent To |
I |
|
| Notes |
| 2005-12-19 00:00:00 | APPROVED BY THE ZONING BASE ON THE | | | ZONING (VARIANCE) CASE #3157 (DAVID | | | KANNING). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
dkanning |
Date |
2005-08-12 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
dkanning |
Date |
2005-08-12 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2005-08-12 00:00:00 | A VARIANCE TO CONSTRUCT THE FRONT PORCH | | | ADDITION 4.9 FEET INTO THE FRONT YARD | | | SETBACK (ZBA CASE NO. 3157-05) WAS | | | APPROVED BY THE ZONING BOARD OF APPEALS | | | ON AUGUST 4, 2005. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-05-23 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-05-23 |
Time |
15:19 |
Sent To |
I |
|
| Notes |
| 2005-05-23 00:00:00 | DENIED, | | | 1. CANNOT ADD ADDITIONAL FRONT PORCH TO | | | EXISTING NON-CONFORMING STRUCTURE. | | | FRONT SETBACK MUST BE A MINIMUN OF 25FT. | | | 2. MAY APPLY FOR VARIANCE BY CALLING | | | 822-1435. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-24 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-24 |
Time |
15:30 |
Sent To |
I |
|
| Notes |
| 2005-03-24 00:00:00 | DENIED - 2ND REQUEST | | | 1. MUST PROVIDE A SITEPLAN OR SURVEY | | | SHOWING THE SETBACKS OF THE STRUCTURE ON | | | PROPERTY. | | | 2. MUST SHOW THE FRONT, SIDE, REAR | | | SETBACK OF EXISTING STRUCTURE AND THE | | | ADDITION. | | | CALLED OWNER. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-11 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-11 |
Time |
12:51 |
Sent To |
B |
|
| Notes |
| 2005-02-11 00:00:00 | DENIED, | | | 1. MUST PROVIDED UPDATED SURVEY WITH | | | SETBACK OF THE EXISTING STRUCTURE AND | | | THE SETBACK OF THE ADDITION. (NEED TO | | | KNOW THE FRONT/SIDE AND REAR SETBACK.) | | | SURVEY PROVIDED IS NOT CLEAR (FAX). | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | CONSTRUCTION SERVICES | | | 805-6720 |
|
|