Plan Review Details - Permit 04121828
Plan Review Stops For Permit 04121828
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-10-11 Cont ID  
Sent By alange Date 2006-10-11 Time 15:27 Rev Time 0.00
Received By alange Date 2006-10-11 Time 15:27 Sent To  
Notes
2006-10-11 15:27:56STRUCTURAL REV. OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-08-08 Cont ID  
Sent By alange Date 2006-08-08 Time 16:19 Rev Time 0.00
Received By alange Date 2006-08-08 Time 16:19 Sent To  
Notes
2006-08-08 00:00:00STRUCTURAL REV. OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2006-02-23 Cont ID  
Sent By alange Date 2006-02-23 Time 13:27 Rev Time 0.00
Received By alange Date 2006-02-23 Time 13:00 Sent To  
Notes
2006-02-23 00:00:00PROCESSED REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-12-30 Cont ID  
Sent By alange Date 2005-12-30 Time 07:04 Rev Time 1.50
Received By alange Date 2005-12-30 Time 07:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-04-26 Cont ID  
Sent By alange Date 2005-04-26 Time 07:51 Rev Time 1.25
Received By alange Date 2005-04-26 Time 07:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-02-09 Cont ID  
Sent By btrobaug Date 2005-02-11 Time 13:46 Rev Time 2.00
Received By alange Date 2005-02-09 Time 08:51 Sent To  
Notes
2005-02-09 00:00:00DENIED
  
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.ENCLOSED SUN ROOM AND EXCERCISE ROOM
 IS A HABITABLE SPACE. THE LOWEST FINISH
 FLOOR ELEVATION SHALL BE A MINIMUM OF 4
 INCHES ABOVE THE FINISH GRADE.
 1804.1.7 WEST PALM BEACH AMMENDMENT TO
 THE FBC.
  
 3.R - VALUE ON ENERGY CALCS FOR
 CEILING INSULATION DO NOT MATCH PLANS.
  
 4.SUBMIT PRODUCT APPROVALS FOR FLAT
 DECK MEMBRANE.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5.CONTRACTOR REQUIRED TO OBTAIN A
 PERMIT.FIVE PROPERTIES ARE OWNED BY
 OWNER BUILDER. SEE FLORIDA STATUTES
 489.
  
 6.WHEN REPAIRS AND ALTERATIONS
 AMOUNTING TO MORE THAN 50% OF THE VALUE
 OF THE EXISTING BUILDING ARE MADE
 DURING
 ANY 12 MONTH PERIOD, THE BUILDING SHALL
 BE MADE TO CONFORM TO THE QUIREMENTS FOR
 A NEW BUILDING.PLEASE SHOW ON PLANS
 HOW EXISTING BUILDING WILL COMPLY.
 FBC 3401.7.2.6
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2007-04-03 Cont ID  
Sent By btrobaug Date 2007-04-03 Time 14:14 Rev Time 0.50
Received By btrobaug Date 2007-04-03 Time 13:07 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-03-13 Cont ID  
Sent By btrobaug Date 2007-03-13 Time 12:49 Rev Time 0.50
Received By btrobaug Date 2007-03-13 Time 12:03 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2007-02-16 Cont ID  
Sent By btrobaug Date 2007-02-16 Time 16:22 Rev Time 0.50
Received By btrobaug Date 2007-02-16 Time 16:13 Sent To PC
Notes
2007-02-16 16:22:17 
 DENIED/INCOMPLETE INFORMATION
  
 THE SHEET THAT WAS SUBMIITED IS DESIGNATED SHEET "2",
 THE SHEET THAT IT IS REVISING IS "6/8" ON THE ORIGINAL
 PLAN. ALSO THE REVISION SUBMITTED IS A DIFFERENT SIZE
 THAN THE ORIGINAL AND MAKES FOR DIFFICULT RECORD
 RETENTION. YHERE WAS SEVERAL DETAILS MISSING FROM THE
 REVISED SHEET THAT WERE ON THE ORIGINAL, LIKE PANEL
 SCHEDULES, LOAD CALC'S, RISER DIAGRAM, ETC. SEE
 ORIGINAL SET, CLOUD AND MARK WITH A DELTA THE AREAS OF
 REVISION. 106.1.3 FBC AS AMMENDED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-02-21 Cont ID  
Sent By btrobaug Date 2006-02-21 Time 07:48 Rev Time 0.50
Received By btrobaug Date 2006-02-21 Time 07:46 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-12-23 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 14:13 Rev Time 0.50
Received By btrobaug Date 2005-12-23 Time 13:48 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-06-01 Cont ID  
Sent By btrobaug Date 2005-06-01 Time 11:24 Rev Time 1.00
Received By btrobaug Date 2005-06-01 Time 11:05 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-03-29 Cont ID  
Sent By dpalmer Date 2005-03-29 Time 15:42 Rev Time 0.50
Received By dpalmer Date 2005-03-29 Time 15:42 Sent To P
Notes
2005-03-29 00:00:00********** UNSAT ************
  
 PLEASE SEE PLANS WERE ORIGINALLY SET UP
 FOR "PROVISO", HOWEVER PLANS ARE COMING
 BACK FOR COMMENTS FROM OTHER
 REVIEWER(S).
 PLEASE MAKE CORRECTIONS AT THIS TIME.
  
  
  
  
 *******************
  
 1)NOTE: PLEASE SEE THERE ARE NUMEROUS
 ITEMS ON ELECTRICAL PANEL SCHEDULE WHERE
 LOAD EXCEEDS RATING OF OCP AND AWG.
 PLEASE SEE 2K ON 20A #12, 2KW ON 20A OCP
 AND ON #14 AWG.
  
 2)NOTE: PLEASE SEE WASHER OS SHOWN AS
 GAS?, PLEASE VERIFY.
  
 3)NOTE: PLEASE SEE PLANS REFERENCE "CITY
 OF PALM BEACH COUNTY". PLEASE SEE JOB IS
 LOCATED IN THE "CITY OF WEST PALM
 BEACH".
  
  
 PLEASE CORRECT AND REVISE:
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-02-11 Cont ID  
Sent By btrobaug Date 2005-02-09 Time 13:03 Rev Time 0.50
Received By btrobaug Date 2005-02-09 Time 12:19 Sent To B
Notes
2005-02-09 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE ARE SEVERAL AREAS THAT DO NOT
 COMPLY WITH THE SPACING REQUIREMENTS OF
 210.52, SUN RM, GREAT ROOM, BED ROOM &
 FAMILY ROOM. SEE REVIEWED PLAN.
  
 2} SMOKE DETECTORS ARE REQUIRED PER
 ARTICLE 8-1.4.1.6.2 NFPA-72,STAIRS AND
 MASTER BEDROOM.
  
 3} SEE 210.63 FOR RECEPTACLE @
 EQUIPMENT
 RE: A/C CONDENSOR(S).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 19 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 17:16 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 17:16 Sent To B
Notes
2008-03-10 17:17:17TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2007-05-11 Cont ID  
Sent By adarroug Date 2007-05-11 Time 13:39 Rev Time 0.00
Received By adarroug Date 2007-05-11 Time 13:39 Sent To M
Notes
2007-05-11 13:39:23TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-04-02 Cont ID  
Sent By spalmer Date 2007-04-02 Time 17:46 Rev Time 0.00
Received By spalmer Date 2007-04-02 Time 17:46 Sent To E
Notes
2007-04-02 17:46:14TO BILL TROBAUGH

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-03-08 Cont ID  
Sent By adarroug Date 2007-03-08 Time 11:16 Rev Time 0.00
Received By adarroug Date 2007-03-08 Time 11:16 Sent To E
Notes
2007-03-08 11:17:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-02-16 Cont ID  
Sent By adarroug Date 2007-02-16 Time 08:33 Rev Time 0.00
Received By adarroug Date 2007-02-16 Time 08:33 Sent To E
Notes
2007-02-16 08:33:19TO "BTROBAUGH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-02-16 Cont ID  
Sent By adarroug Date 2007-02-16 Time 08:30 Rev Time 0.00
Received By adarroug Date 2007-02-16 Time 08:30 Sent To P
Notes
2007-02-16 08:31:18TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-02-15 Cont ID  
Sent By adarroug Date 2007-02-15 Time 16:27 Rev Time 0.00
Received By adarroug Date 2007-02-15 Time 16:27 Sent To M
Notes
2007-02-15 16:28:10TO "M' BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2006-12-15 Cont ID  
Sent By adarroug Date 2006-12-15 Time 15:24 Rev Time 0.00
Received By adarroug Date 2006-12-15 Time 15:24 Sent To M
Notes
2006-12-15 15:24:43TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-12-01 Cont ID  
Sent By adarroug Date 2006-12-01 Time 13:27 Rev Time 0.00
Received By adarroug Date 2006-12-01 Time 13:27 Sent To M
Notes
2006-12-01 13:27:56TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-09-29 Cont ID  
Sent By adarroug Date 2006-09-29 Time 10:10 Rev Time 0.00
Received By adarroug Date 2006-09-29 Time 10:10 Sent To B
Notes
2006-09-29 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-08-01 Cont ID  
Sent By adarroug Date 2006-08-01 Time 14:06 Rev Time 0.00
Received By adarroug Date 2006-08-01 Time 14:06 Sent To B
Notes
2006-08-01 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-02-03 Cont ID  
Sent By adarroug Date 2006-02-03 Time 08:36 Rev Time 0.00
Received By adarroug Date 2006-02-03 Time 08:36 Sent To M
Notes
2006-02-03 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 10:07 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 10:07 Sent To E
Notes
2005-12-20 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-12-10 Cont ID  
Sent By adarroug Date 2005-12-10 Time 11:20 Rev Time 0.00
Received By adarroug Date 2005-12-10 Time 11:20 Sent To Z
Notes
2005-12-10 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-08-09 Cont ID  
Sent By adarroug Date 2005-08-09 Time 18:03 Rev Time 0.00
Received By adarroug Date 2005-08-09 Time 18:03 Sent To Z
Notes
2005-08-09 00:00:00TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-05-24 Cont ID  
Sent By adarroug Date 2005-05-24 Time 09:49 Rev Time 0.00
Received By adarroug Date 2005-05-24 Time 09:49 Sent To E
Notes
2005-05-24 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-05-17 Cont ID  
Sent By adarroug Date 2005-05-17 Time 14:40 Rev Time 0.00
Received By adarroug Date 2005-05-17 Time 14:40 Sent To Z
Notes
2005-05-17 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-03-28 Cont ID  
Sent By adarroug Date 2005-03-28 Time 14:31 Rev Time 0.00
Received By adarroug Date 2005-03-28 Time 14:31 Sent To E
Notes
2005-03-28 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-03-22 Cont ID  
Sent By adarroug Date 2005-03-22 Time 15:42 Rev Time 0.00
Received By adarroug Date 2005-03-22 Time 15:42 Sent To Z
Notes
2005-03-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 8 Status P Date 2007-05-15 Cont ID  
Sent By tgordon Date 2007-05-15 Time 16:35 Rev Time 0.25
Received By tgordon Date 2007-05-15 Time 16:35 Sent To  
Notes
2007-05-15 16:35:43REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2007-02-20 Cont ID  
Sent By tgordon Date 2007-02-20 Time 10:28 Rev Time 0.25
Received By tgordon Date 2007-02-20 Time 10:28 Sent To  
Notes
2007-02-20 10:29:18REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2006-12-18 Cont ID  
Sent By tgordon Date 2006-12-18 Time 11:18 Rev Time 0.30
Received By tgordon Date 2006-12-18 Time 11:18 Sent To  
Notes
2006-12-18 11:18:47REVISION TO MECH. PLANS AND E-CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2006-12-04 Cont ID  
Sent By tgordon Date 2006-12-04 Time 08:40 Rev Time 0.30
Received By tgordon Date 2006-12-04 Time 08:40 Sent To  
Notes
2006-12-04 08:51:43MECHANICAL REVISION
 *** DENIED ***
 1) ENERGY CALCULATIONS LINE 13 HEATING SYSTEMS (A) AND
 (B) ARE CALLING FOR GAS HYDRONIC SPACE & WATER HEATER,
 PLANS ARE CALLING FOR A 10 KW AND A 5 KW ELECTRIC
 HEATERS, PLEASE CORRECT ENERGY CALCULATIONS.
  
 2) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 3) PLEASE SHOW ON PLANS TOTAL AND SENSIBLE BTU'S. FOR
 A/C SYSTEMS.
  
 4) RETURN AIR TRANSFER DUCTS TO NEW GYM AND THE TWO
 EXISTING BEDROOM ON THE FIRST FLOOR ARE TO SMALL.
 BALANCED RETURN AIR.
 MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-02-03 Cont ID  
Sent By tgordon Date 2006-02-03 Time 14:43 Rev Time 1.00
Received By tgordon Date 2006-02-03 Time 14:43 Sent To P
Notes
2006-02-03 00:00:00*** PROVISO ***
 1) COVERED PORCH, EXHUST HOOD DUCT MUST
 BE 10" 16 GAGE STEEL, PER MANF. INST.
 AND 2001 FBC/M 506.3.1.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-12-27 Cont ID  
Sent By tgordon Date 2005-12-27 Time 08:42 Rev Time 0.45
Received By tgordon Date 2005-12-27 Time 08:42 Sent To P
Notes
2005-12-27 00:00:00*** DENIED ***
 1) NEED TO SHOW SIZE OF RETURN AIR GRILL
 AT AHU, AND IF BIFOLD DOOR IS LOUVERED.
  
 2) BBQ GRILL UNDER COVERED PORCH NEEDS
 AN APPROVED EXHAUST HOOD OVER IT, PER
 2001 FBC/M 505.3 .
  
 3) TRANSFER DUCT FROM NEW GYM IS TO
 SMALL, PLEASE SEE NOTE 4 .
  
 4) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-04-11 Cont ID  
Sent By prafter Date 2005-04-11 Time 09:57 Rev Time 0.50
Received By prafter Date 2005-04-11 Time 09:50 Sent To B
Notes
2005-04-11 00:00:00SECOND MECH. PLAN REVIEW.
  
 ALL SIX ITEMS SATIFIED.
  
 PAT RAFTER 805/6728.
 PLEASE CALL IF THEIR ANY QUESTIONS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-02-10 Cont ID  
Sent By pkrauss Date 2005-02-10 Time 06:49 Rev Time 0.40
Received By pkrauss Date 2005-02-10 Time 06:38 Sent To B
Notes
2005-02-10 00:00:00DENIED:
 1.PLAN SHEET A/2 INDICATES A GAS WATER
 HEATER SHARING THE CLOSET WITH THE AHU.
 PER 2001 FBC(M)603.9, COMBUSTION WATER
 HEATERS SHALL NOT BE LOCATED IN
 MECHANICAL CLOSETS USED AS RETURN AIR
 PLENUMS.
  
 2.PLAN SHEET A/2 INDICATES A GAS
 DRYER.PROVIDE CALCULATIONS FOR
 COMBUSTION AIR IN ACCORDANCE WITH 2001
 FBC(M) CHAPTER 7.
  
 3.INDICATE ON THE PLAN METHOD OF
 MAKE-UP AIR.
  
 4.PROVIDE SUBMITTAL DATA FOR ALL GAS
 APPLIANCES.
  
 5.PLAN SHEET A/8, PLAN DOES NOT
 INDICATE ANY RETURN AIR FROM NEW GYM AND
 SUNROOM AREAS.PLEASE SHOW COMPLIANCE
 WITH 2001 FBC(M)601.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 5 Status F Date 2007-03-08 Cont ID  
Sent By jleech Date 2007-03-08 Time 08:33 Rev Time 0.00
Received By jleech Date 2007-03-08 Time 08:32 Sent To  
Notes
2007-03-08 08:38:36DENIED;
 REVISED DRAWINGS MUST BE DRAWN AND SIGNED AND UNDER THE
 SAME TITLE BLOCK AS ORIGIAL APPROVED PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-02-21 Cont ID  
Sent By jleech Date 2006-02-21 Time 07:23 Rev Time 0.50
Received By jleech Date 2006-02-21 Time 07:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2005-12-29 Cont ID  
Sent By jleech Date 2005-12-29 Time 07:57 Rev Time 0.50
Received By jleech Date 2005-12-29 Time 07:57 Sent To B
Notes
2005-12-29 00:00:00DENIED
 1.SHOW HOW EXISTINGSHOWER DRAIN IS
 PIPED ON FLAT PLAN AND RISER DIAGRAM.
 2.HORIZONTAL DRY VENTS ARE NOT PERMITED,
 MASTER BATHROOM.
 3.AN DEMAND GAS WATER HEATERS MUST BE
 INSTALLED ON THE OUTSIDE OF BUILDING NOT
 IN LAUNDRY ROOM AS SHOWN ON PLANS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-04-09 Cont ID  
Sent By jleech Date 2005-04-09 Time 08:45 Rev Time 0.33
Received By jleech Date 2005-04-09 Time 08:45 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-02-11 Cont ID  
Sent By dpalmer Date 2005-03-29 Time 16:01 Rev Time 0.50
Received By kstevens Date 2005-02-11 Time 13:31 Sent To  
Notes
2005-02-11 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) CLEANOUTS ARE REQUIRED NEAR THE
 JUNCTION OF THE BUILDING DRAIN AND THE
 BUILDING SEWER. SECTION 708.3.5. (SEE
 THE LINES TO THE MASTER BATH STACK, THE
 WASH MACHINE AND THE POWDER ROOM/KITCHEN
 SINK BUILDING DRAIN LINES.
 2) ALL DRAWINGS SHALL BEAR THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. SIGNATURE STAMPS ARE NOT
 ACCEPTABLE. SIGNATURE IS REQUIRED.
 SECTION 104.2.1.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 5 Status P Date 2005-12-19 Cont ID  
Sent By mmclean Date 2005-12-19 Time 17:40 Rev Time 0.00
Received By mmclean Date 2005-12-19 Time 17:40 Sent To I
Notes
2005-12-19 00:00:00APPROVED BY THE ZONING BASE ON THE
 ZONING (VARIANCE) CASE #3157 (DAVID
 KANNING).

Review Stop Z ZONING
Rev No 4 Status P Date 2005-08-12 Cont ID  
Sent By dkanning Date 2005-08-12 Time 15:39 Rev Time 0.00
Received By dkanning Date 2005-08-12 Time 15:38 Sent To  
Notes
2005-08-12 00:00:00A VARIANCE TO CONSTRUCT THE FRONT PORCH
 ADDITION 4.9 FEET INTO THE FRONT YARD
 SETBACK (ZBA CASE NO. 3157-05) WAS
 APPROVED BY THE ZONING BOARD OF APPEALS
 ON AUGUST 4, 2005.

Review Stop Z ZONING
Rev No 3 Status F Date 2005-05-23 Cont ID  
Sent By mmclean Date 2005-05-23 Time 15:19 Rev Time 0.00
Received By mmclean Date 2005-05-23 Time 15:19 Sent To I
Notes
2005-05-23 00:00:00DENIED,
 1. CANNOT ADD ADDITIONAL FRONT PORCH TO
 EXISTING NON-CONFORMING STRUCTURE.
 FRONT SETBACK MUST BE A MINIMUN OF 25FT.
 2. MAY APPLY FOR VARIANCE BY CALLING
 822-1435.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2005-03-24 Cont ID  
Sent By mmclean Date 2005-03-24 Time 15:30 Rev Time 0.00
Received By mmclean Date 2005-03-24 Time 15:30 Sent To I
Notes
2005-03-24 00:00:00DENIED - 2ND REQUEST
 1. MUST PROVIDE A SITEPLAN OR SURVEY
 SHOWING THE SETBACKS OF THE STRUCTURE ON
 PROPERTY.
 2. MUST SHOW THE FRONT, SIDE, REAR
 SETBACK OF EXISTING STRUCTURE AND THE
 ADDITION.
 CALLED OWNER.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-02-11 Cont ID  
Sent By mmclean Date 2005-02-11 Time 12:51 Rev Time 0.00
Received By mmclean Date 2005-02-11 Time 12:51 Sent To B
Notes
2005-02-11 00:00:00DENIED,
 1. MUST PROVIDED UPDATED SURVEY WITH
 SETBACK OF THE EXISTING STRUCTURE AND
 THE SETBACK OF THE ADDITION. (NEED TO
 KNOW THE FRONT/SIDE AND REAR SETBACK.)
 SURVEY PROVIDED IS NOT CLEAR (FAX).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 CONSTRUCTION SERVICES
 805-6720