| Plan Review Stops For Permit 04121827 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-15 |
Time |
07:16 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-11-15 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | SHUTTER REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-06 |
Time |
08:01 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-10-06 |
Time |
07:52 |
Sent To |
Z |
|
| Notes |
| 2005-10-06 00:00:00 | WALL REVISION OKALANGE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-09 |
Time |
09:45 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-09-09 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-09-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-09-07 |
Time |
16:21 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-09-07 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2005-09-07 00:00:00 | DENIED | | | FOURTH PLAN REVIEW SAME COMMENT: | | | | | | 3.KOLBE AND KOLBE PRODUCT APPROVALS | | | SUBMITTED ARE MISSING THE APPROPRIATE | | | STATE PRODUCT APPROVALS. | | | | | | THE FOLLOWING STATE PRODUCT APPROVAL | | | INFORMATION IS REQUIRED WITH EACH | | | PRODUCT APPROVAL WITH QUALITY ASSURANCE. | | | * PLEASE READ THE FOLLOWING THIS IS THE | | | FOURTH TIME THIS SAME COMMENT HAS BEEN | | | MADE* | | | | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-16 |
Time |
15:31 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-08-16 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2005-08-16 00:00:00 | DENIED | | | | | | 3.PRODUCT APPROVALS: | | | **SUBMIT TWO COMPLETE SETS OF PRODUCT | | | APPROVALS WITH QUALITY ASSURANCE FOR THE | | | FOLLOWING WITH STATE APPROVALS | | | ATTACHED.** STRAPS AND TIE DOWNS OK. | | | PRODUCT APPROVALS ARE REQUIRED FOR THE | | | FOLLOWING:EXTERIOR DOORS, WINDOWS, | | | IMPACT PROTECTION, TILE ROOF AND FLAT | | | ROOF. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-07-15 |
Time |
14:11 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2005-07-15 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2005-07-15 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.PRODUCT APPROVALS: | | | **SUBMIT TWO COMPLETE SETS OF PRODUCT | | | APPROVALS WITH QUALITY ASSURANCE FOR THE | | | FOLLOWING WITH STATE APPROVALS | | | ATTACHED.** STRAPS AND TIE DOWNS OK. | | | PRODUCT APPROVALS ARE REQUIRED FOR THE | | | FOLLOWING:EXTERIOR DOORS, WINDOWS, | | | IMPACT PROTECTION, TILE ROOF AND FLAT | | | ROOF. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | 4.SIGN OWNER/AGENT ON ENERGY CALCS. | | | SUBMIT 2 COPIES OF ENERGY CALCS. | | | | | | NEW COMMENT: | | | A:ARCHITECT TO SIGN AND SEAL ALL PAGES | | | SUBMITTED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-21 |
Time |
09:33 |
Rev Time |
2.25 |
| Received By |
alange |
Date |
2005-01-21 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.PRODUCT APPROVALS: | | | PRODUCT APPROVALS ARE REQUIRED FOR THE | | | FOLLOWING:STRAPS AND TIE-DOWNS, | | | EXTERIOR DOORS, WINDOWS, IMPACT | | | PROTECTION, TILE ROOF AND FLAT ROOF. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | 4.1015.2 HEIGHT. GUARDRAILS SHALL FORM | | | A VERTICAL PROTECTIVE BARRIER NOT LESS | | | THAN 42" HIGH. | | | 1015.3 OPENINGS. OPEN GUARDRAILS | | | SHALL HAVE INTERMEDIATE RAILS OR ORNA- | | | MENTAL PATTERNS SUCH AS A 4" DIAMETER | | | SPHERE CAN NOT PASS THROUGH. A BOTTOM | | | RAIL OR CURB SHALL BE PROVIDED THAT WILL | | | REJECT THE PASSAGE OF 2" DIAMETER | | | SPHERE.SEE ALSO A-8 #1 | | | | | | | | | 5. FBC 2309.6ACCESS TO ATTIC SPACE | | | EACH ATTIC SPACE WITH A CLEAR HEIGHT OF | | | 24" OR GREATER SHALL BE PROVIDED WITH AN | | | INTERIOR ATTIC ACCESS OPENING NOT LESS | | | THAN 20"X 36".PLEASE SHOW LOCATIONS ON | | | PLANS. | | | | | | 6. SHOW HANDRAILS AT STAIRS ON S-3 #1 | | | | | | 7.SHOW HOW EXISTING BUILDING WILL | | | COMPLY FOR GFCI OUTLETS AND SMOKE | | | DETECTORS. FBC 3401.7.1.2.1 | | | | | | 8.SUBMIT 2 COPIES OF ENERGY CALCS. | | | | | | 9.SHOW SIZE AND TYPE OF BEDROOM | | | WINDOWS AND SILL HEIGHT FROM FLOOR. | | | FBC 1005.4 | | | | | | 10. CHIMNEY HEIGHT SHALL COMPLY WITH | | | FBC 2804.2.4 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-16 |
Time |
20:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-16 |
Time |
19:51 |
Sent To |
PC |
|
| Notes |
| 2006-10-16 20:19:21 | REDLINED TO VERIFY THE GROUNDING ELECTRODE CONDUCTOR , | | | PER 250.66, SHOWS #1, SEEMS TO BE MISPRINT? SEC'S NOT | | | SHOWN AT THIS TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-06 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-06 |
Time |
16:05 |
Sent To |
PC |
|
| Notes |
| 2006-10-06 00:00:00 | ***** UNSAT ***** | | | | | | 1) NOTE: PLEASE SEE RISER IS SHOWING | | | DISONNECT AS WHAT IS REALLY AND "PANEL" | | | FOR THE HWH. PLEASE INDICATE ON RISER AS | | | "PANEL HWH", AND ON PANEL "B" SCHEDULE | | | "PANEL HWH" OR ANY LABELING WHICH CALLS | | | FOR THIS BEING A PANEL. | | | PLEASE SEE NO DISCONNECTING MEANS IS | | | BEING SHOWN FOR THE UNIT. THE PANEL IS | | | LOCATED IN THE HALL WHICH IS OK, HOWEVER | | | IS NOT WITHINSIGHT OF UNIT FOR | | | DISCONNECTING MEANS. | | | 422.31, 422.31. | | | PLEASE SEE KNOW, MIN CLEARENCES STILL | | | MUST BE MET FOR UNIT(S) FROM | | | COMBUSTIBLES AS REQUIRED PER | | | MANUFACTURES SPEC(THIS IS TO BE | | | VERIFIED). | | | | | | ** PLEASE KNOW, ANY USE OF BREAKERS FOR | | | A MEANS OF DISCONNECT, PLEASE KNOW THE | | | "LOCK-OFF" DEVICE, MUST BE AN "INTEGRAL" | | | PART OF THE BREAKER. THE "SNAP" ON | | | DEVICES WHICH READILY FALL OFF ARE NOT | | | PERMITTED OR ACCEPTABLE. | | | | | | ** PLEASE SEE THEN KW RATING ON LOAD | | | CALCS AND DISC/PANEL HWH SHOW TWO | | | DIFFERENT LOADS. | | | PLEASE CORRELATE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-28 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-27 |
Time |
19:32 |
Sent To |
PC |
|
| Notes |
| 2006-09-28 00:00:00 | ********** UNSAT *********** | | | | | | ***** PLEASE SEE ELECTRICAL RISER | | | DIAGRAM HAS NOW BEEN COMPLETELY REVISED | | | WHICH IS NOT CODE COMPLIANT. | | | | | | | | | | | | 1) NOTE: PLEASE SEE RISER NOW SHOWS THE | | | DISCONNECT ON THE LOAD SIDE OF THE ATS | | | AS 100A'S, WHEN THE OCP AND LOAD THROUGH | | | THIS DISCONNECT IS GREATER AND EXCEEDS | | | THAT OF ITS RATING. | | | 240. 408 ETC. | | | | | | 2) NOTE: PLEASE SEE NOW A NEW PANEL "C" | | | IS BEING INTRODUCED BEING FED FROM THE | | | GARAGE WHICH IS A DETACHED BLUIDING. | | | PLEASE SEE THIS PANEL IS BEING SHOWN | | | UPSTAIRS AND MLO. | | | PLEASE SEE THIS IS NOT PERMITTED. | | | PLEASE SEE 225.31-225.39. | | | PLEASE ALSO SEE THIS PANEL IS BEING | | | SHOWN AS NO MEETING 110.26. | | | | | | 3) NOTE: PLEASE SEE LOAD ON PANEL "C" | | | FOR TANKLESS WATER HEATER DOES NOT | | | CORRELATE WITH LOAD CALCULATIONS. | | | 220.31 | | | | | | 4) NOTE: PLEASE COMPLETE AND PROVIDE | | | LOADCALULATIONS ON EACH OF THE PANELS | | | AS SHOWN.220.31, 215.5 | | | FBC106.1.2 ADMIN SECT. | | | | | | 5) NOTE: PLEASE SEE 250.32, 250.50 FOR | | | NON COMPLIANCE FOR NEW PANEL. | | | | | | | | | ** PLEASE KNOW, BASED ON THE NEW REVISED | | | PLANS SUBMITTED, IT IS THE HOPE OF THIS | | | OFFICE THAT THE INSTALLATION IN FIELD IS | | | NOT WHAT IS SHOWN ON PLANS. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-19 |
Time |
20:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-19 |
Time |
20:28 |
Sent To |
PC |
|
| Notes |
| 2006-09-19 00:00:00 | ****** UNSAT 3RD REVIEW OF REVSIONS*** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW. | | | | | | REVIEW FOR REV #5 AND 6. | | | | | | 1) NOTE: PLEASE SEE LOAD FOR TANKLESS | | | WATER HEATER IS NOW BEING SHOWN AT | | | 27KVA?? < YET, PLEASE SEE OCP IS STIL | | | BEING SHOWN AT 100A'S? | | | LOAD WAS INCREASED, YET THE OCP IS NOW | | | NOT LARGE ENOUGH FOR THE NEW 27KW SHOWN. | | | PLEASE ALSO SEE PLANS SHOW A "GAS " | | | UNIT? IS THE UNIT #1, AS THE ONE LOCATED | | | ON THE PANEL SCHEDULE IS UNIT #2.?? | | | PLEASE SEELOAD CALCULATIONS STILL DO | | | NOT SHOWN THIS 27KW LOAD. | | | 220.31,240.4,310.16, ETC. | | | | | | 2) NOTE: PLEASE SEE PANELS A AND B IN | | | MAIN HOUSE APPEARS TO SHOW SOME SORT OF | | | COUNTER /WALL OR SOMETHING LOCATED IN | | | FRONT OF THESE. PLEASE SEE 110.26.240.24 | | | 408.7 ETC. | | | | | | 3) NOTE: PLEASE SEE NOT ALL SHEETS ARE | | | SEALED BY THE ARCHITECT. | | | FBC 106.1, FS 481.221 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-13 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-13 |
Time |
10:43 |
Sent To |
PC |
|
| Notes |
| 2006-04-13 00:00:00 | ** UNSAT ** | | | | | | PLEASE SEE SOME NOTE FROM PREVIOUS | | | REVIEW WHICH ARE STILL IN NEED OF | | | CORECTING. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW. | | | | | | *********** UNSAT ***************** | | | | | | | | | 1) NOTE: OK | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE: OK | | | | | | 4) NOTE:NO, PLEASE SEE SIZE HAS NOT | | | INCREASED AND PLEASE SEE MULTIPLE | | | LOCATIONS OF ATTACHMENT SHOWN ON RISER.. | | | PLEASE SEE 250.6,250.24B. | | | | | | ** PRE-NOTE** | | | PLEASE SEE THE EXISTING | | | GROUNDING ELECTRODE CONDUCTOR IS NO | | | LONGER LARGE ENOUGH DUR TO THE INCREASE | | | OF SERVICE. PLEASE SEE TABLE IN250.66 | | | AND ADJUST. | | | | | | 5)NOTE: OK. | | | | | | 6) NOTE: OK | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE:NO, PLEASE SEE NO CHANGE WAS | | | MADE TO THE KVA LOADS ON PANEL SCHEDULE | | | OR IN LOAD CALCS. | | | | | | ** PRE- NOTES** | | | PLEASE SEE 100A BRKR IS BEING | | | SHOWN FOR NEW ELECTRIC TANKLESS UNIT, | | | HOWEVER THE LOAD IS SHOWN AS 1.2VA PER | | | PHASE AND IS NOT SHOWN IN LOAD CALCS. | | | THIS WILL GREATLY AFFECT LOAD CALCS. | | | 215.5, 220 | | | | | | 9) NOTE: OK | | | | | | 10) NOTE: OK | | | | | | 11) NOTE: | | | | | | 12) NOTE: | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLANREVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
20:48 |
Sent To |
PC |
|
| Notes |
| 2006-03-24 00:00:00 | *********** UNSAT ***************** | | | | | | | | | 1) NOTE: PLEASE SEE PLANS ARE COMING IN | | | WITH HAND DRAWN CHANGES MADE ON PLANS | | | WHICH ARE SIGNED, DATED AND SEALED BY AN | | | ARCHITECT WHICH IS NOT PERMITTED UNDER | | | FS 481.221 | | | PLEASE REVISE, RE-PRINT AND HAVE | | | ARCHITECT SIGN,DATE AND SEAL PLANS. | | | | | | 2) NOTE: PLEASE SEE RISER IS COMING IN | | | COMPLETELY DIFFERENT FROM PREVIOUS | | | PLANS. PLEASE SEE NOW, SERVICE HAS BEEN | | | INCREASED FROM THE PREVIOUS 300A'S TO | | | NOW A 500A SERVICE. PLEASE SEE EXST, | | | PREVIOUS SEC'S WERE SHOWN AS 350 MCM'S, | | | HOWEVER THESE CONDUCTORS HAVE NOW BEEN | | | REMOVED FROM THE PLANS. | | | PLEASE SHOW THE SIZE OF THE NEW SEC'S IN | | | RISER AND THE INCREASE OF THE SIZE OF | | | RISER. PLEASE SHOW THE CONDUCTORS NOW | | | BEING USED FROM THE GUTTER TO THE NEW | | | MAINS AND EXIST. | | | PLEASE INCLUDE THE SIZE OF THE GUTTER, | | | IS THE EXST ONE LARGE ENOUGH? SHOW NEW | | | SIZE. | | | 240.4,310.15B6, 215.5 | | | | | | 3) NOTE: PLEASE SUBMITAIC RATINGS FOR | | | NEW EQUIPMENT. | | | 215.5,110.9 | | | | | | 4) NOTE: PLEASE SEE THE EXISTING | | | GROUNDING ELECTRODE CONDUCTOR IS NO | | | LONGER LARGE ENOUGH DUR TO THE INCREASE | | | OF SERVICE. PLEASE SEE TABLE IN250.66 | | | AND ADJUST. | | | | | | 5)NOTE: PLEASE SEE NEW PLANS DO NOT | | | GROUP MAINS AT MAIN HOUSE AS REQUIRED | | | PER 225.34. PLEASE SEE PLANS INDICATE | | | ONE MAIN UPSTAIRS AND ONE DOWNSTAIRS???? | | | PLEASE SEE ORIG PLANS CALLED FOR ONE | | | PANEL, (EXIST) | | | IT IS THIS OFFICE'S HOPE THIS IS NOT | | | INSTALLED THIS WAY. | | | PLEASE ALSO SEE THE EFFECT THIS WOULD | | | AHVE FOR LOCATION OF GROUNDING THE | | | SYSTEM AT THE MAIN HOUSE FOR THE NEW | | | MAINS WHICH WILL BE REQUIRED. 250.32 | | | | | | 6) NOTE: PLEASE SEE MIN OCP FORAHU'S | | | TO BE 125%. 424.3B, PLEASE SEE 50A OCP | | | FOR 10KW UNIT. | | | | | | 7) NOTE: PLEASE SEE MIN VA FOR LAUNDRY / | | | WASHER CIRCUIT. 210.11C2, 220.16B | | | 1.5MIN | | | | | | 8) NOTE: PLEASE SEE 100A BRKR IS BEING | | | SHOWN FOR NEW ELECTRIC TANKLESS UNIT, | | | HOWEVER THE LOAD IS SHOWN AS 1.2VA PER | | | PHASE AND IS NOT SHOWN IN LOAD CALCS. | | | THIS WILL GREATLY AFFECT LOAD CALCS. | | | 215.5, 220 | | | | | | 9) NOTE: PLEASE SEE REDLINED PLANS FOR | | | LOAD CALCULATIONS FROM PREVIOUS PLANS | | | PER 220.31B | | | | | | 10) NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 , SOME OF THESE WERE REMOVED FROM | | | PREVIOUS PLANS AND SOME WHICH WERE | | | REDLINED FROM ORIG PLANS ARE STILL NOT | | | IMPLEMENTED INTO PLANS. | | | | | | 11) NOTE: PLEASE SEE MANY AREAS/ROOMS | | | WHERE THE REQUIRED EGRESS LT FIXTURE IS | | | KNOW ONLY SHOWN AS A "J-BOX" , PLEASE | | | KNOW, A MIN FIXTURE OF SOME SORT WILL BE | | | REQUIRED FOR MIN EGRESS. 210.70, | | | NFPA-101 7.8 | | | PLEASE REVISE PLANS. | | | | | | 12) NOTE: PLEASE VERIFY THE MAINS AND | | | SPACES AT THE 400A METER/MAIN. PLEASE | | | KNOW, NO MORE THAN 6 MAINS ARE | | | PERMITTED, PLEASE ALSO SEE NO MORE THAN | | | 5 SPACES WOULD BE PERMITTED IN | | | METER/MAIN. PLEASE PROVIDE SCHEDULE FOR | | | M/M OR PROVIDE INFORMATION IS INDEED | | | THERE IS A 400A MAIN BRKR. | | | 230.70, 230.71 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLANREVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | 2006-03-23 00:00:00 | NOTES |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-09-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-03 |
Time |
10:33 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-09-03 |
Time |
10:27 |
Sent To |
B |
|
| Notes |
| 2005-09-03 00:00:00 | ** REDLINED NOTES, PLAN OK AND STAMPED** | | | | | | | | | | | | PLEASE SEE 220.31B FOR LOAD | | | CALCULATIONS, | | | 1ST 8KW AT 100% | | | REMAINDER @ 40%,. 35% SHOW. | | | | | | PLEASE SEE LOAD CALCS INDICATE SERVICE | | | AT 300A'S. PLEASE SEE 310.15B6, FOR | | | 350MCM, IS RATED FOR 350A'S. SF | | | DWELLING. | | | | | | 110.26 FOR A/C DISC. | | | 210.52 FOR MASTER BEDRM RECEPT MISSING | | | WITHIN 6' OF DOOR. | | | *************************************** | | | NO CORRECTIONS NEEDED AT THIS TIME> IF | | | PLANS COME ABCK IN FOR REVISIONS DURING | | | BLDG, PLEASE MAKE ABOVE ADUSTMENTS AT | | | THAT TIME. | | | *************************************** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-01 |
Time |
07:00 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-08-01 |
Time |
06:44 |
Sent To |
P |
|
| Notes |
| 2005-08-01 00:00:00 | ************ UNSAT 3RD REVIEW ********* | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS TWO | | | REVIEWS STILL NEED TO BE ADDRESSED. | | | PLEASE SEENEW NOTES DUE TO CHANGES IN | | | PLANS. | | | | | | 1)NOTE: PLEASE SHOW ALL SERVICE | | | EQUIPMENT ON PLANS. PLEASE SEE PREVIOUS | | | PLANS SHOWED TWO PANELS, NOW ONE PANEL | | | "K" HAS BEEN REMOVED AND METER/MAINS, | | | ETC ARE NOT SHOWN? | | | PLEASE SEE RISER NOW SHOWS PANEL "H" AS | | | EXISTING? HOW IS THIS POSSIBLE IF THIS | | | PANEL IS BEING SHOWN BEING LOCATED IN | | | NEW ADDTION SECTION OF HOUSE? | | | IF SERVICE IS LOCATED AT A DEATCHED BLDG | | | AS NOW SHOWN ON RISER DIAGRAM, THEN | | | PLEASE SEE 250.32 FOR GROUNDING | | | ELECTRODE SYSTEM ETC AT DETACHED BLDG'S. | | | PLEASE ALSO SEE NEW COMMENTS BASED ON A | | | RISER DIAGRAM NOW BEING SUBMITTED. | | | | | | 2)NOTE: PLEASE SEE RISER NOW SUBMITTED, | | | HOWEVER PLEASE SEE THAT PANEL SCHEDULES | | | WHICH WERE SUBMITTED FOR THE LAST TWO | | | REVIEWS HAVE NOW BEEN REMOVED FROM | | | PLANS? | | | PREVIOUS PLANS CALLED FOR A 400A | | | SERVICE, PLANS NOW INDICATE A 300A | | | SERVICE. PREVIOUS COMMENT REQUIRING A | | | 1/0 MIN FOR GROUNDING ELECTRODE IS NO | | | LONGER RELEVENT. | | | PLEASE SUBMIT. UNABLE TO VERIFY SOME | | | PREVIOUS NOTES. | | | NEED TO VERIFY OVER CURRENT PROTECTION, | | | CONDUCTOR SIZES, ARC FAULT PROTECTION, | | | ETC.215.5 | | | | | | 3)NOTE: PLEASE SEE NEW RISER SHOWS AN | | | EQUIPMENT GROUNDING CONDUCTOR FROM | | | GUTTER TO GARAGE MAIN. PLEASE SEE 250.6, | | | 250.24, "EQUIPMENT GROUNDING" CONDUCTORS | | | ARE ONLY INSTALLED AFTER THE FIRST MEANS | | | OF DISCONNECT. | | | | | | 4)NOTE: PLEASE SEE "NEW FOOTER" STEEL IS | | | STILL NOT SHOWN TO BE A PART OF THE | | | GROUNDING ELECTRODE SYSTEM. 250.50 | | | | | | 5)NOTE: PLEASE SEE BOTTOM OF LOAD | | | CALCULATIONS STILL SHOW "EXISTING | | | SERVICE" 200A'S.?? PLEASE SEE RISER | | | SHOWS SERVICE AS 300A'S. | | | PLEASE SEE LOAD FOR "GARAGE PANEL" CAN | | | NOT BE VERIFIED AS NO PANEL SCHEDULE(S) | | | OR IDENTIFICATION IS SHOWN. | | | 215.5 | | | | | | 6)NOTE: PLEASE SEE PREVIOUS PLANS SHOWED | | | ALL CIRCUITING, HOWEVER PLANS DO NOT | | | SHOW THIS NOW? | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE PREVIOUS NOTES | | | REFERENCED ARC FAULT PROTECTION FOR SD'S | | | ALSO, HOWEVER "RESPONSE LTR" MENTIONS, | | | "WHERE APPLICABLE" ?? | | | PLEASE KNOW, SD'S ARE ALL WIRED IN-LINE | | | AS REQUIRED IN NFPA-72 8-1.4 .ALL SD'S | | | SHALL BE ON AN ARC FAULT PROTECTED | | | CIRCUIT. | | | | | | 8)NOTE: PLEASE SEE FS 553.80(2)B) | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO A | | | MIN OF TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. ONE COPY OF OLD/VOIDED SHEETS | | | SHALL BE SUBMITTED FOR REFERENCE. | | | ONE COPY OF ELECTRICAL PLANS HAVE BEEN | | | RETAINED FOR FILE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | | | | | | | 250.50 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-20 |
Time |
16:30 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-06-20 |
Time |
16:11 |
Sent To |
P |
|
| Notes |
| 2005-06-20 00:00:00 | ******* UNSAT 2ND REVIEW ***** | | | | | | PLEASE SEE SOME NOTES FROM | | | PREVIOUS/FIRST REVIEW STILL NEED TO BE | | | ADDRESSED. | | | | | | 1)NOTE: NOTE#1 OK. | | | | | | 2)NOTE: NOTE #2, NO, NO RISER SUBMITTED | | | ON E-1 | | | | | | 3)NOTE: NOTE #3 NO, NO RISER. | | | | | | 4)NOTE: NOTE #4 NO, NO RISER, ALTHOUGH | | | A-SHEET APPEARS TO SHOW SERVICE GROUPED? | | | | | | 5)NOTE: NOTE #5 NO, NO RISER. | | | | | | 6)NOTE: NOTE #6 NO, NO RISER. | | | | | | 7)NOTE: NOTE #7 NO, NO RISER. | | | | | | 8)NOTE: NOTE# 8 OK, HOWEVER PLEASE SEE | | | ONE AHU IS SHOWN WITH NO INFORMATION ON | | | PANEL SCHEDULE? "BLANK". | | | | | | 9)NOTE: NOTE #9 NO, NO RISER. | | | | | | 10)NOTE: NOTE #10 OK. | | | | | | 11)NOTE: NOTE #11 OK. | | | | | | 12)NOTE: NOTE #12 OK. | | | | | | 13)NOTE: NOTE #13 NO, PLEASE SEE SOME | | | MISSING. BATH GFI. | | | | | | 14)NOTE: NOTE #14 OK, HOWEVER PLEASE SEE | | | 210.12 2002 NEC FOR ARC FAULT | | | PROTECTION. | | | | | | 15)NOTE: NOTE #15 NO, NO RISER. | | | | | | 16)NOTE: NOTE #16 NO, PLEASE SEE | | | 220.31B | | | | | | 17)NOTE: NOTE #17 NO,PLEASE SEE FIRST | | | FLR. | | | | | | 18)NOTE: NOTE #18 NO, PLEASE SEE SD'S | | | AND NOTE ABOVE. | | | | | | 19)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) ATTACHED WITH RESPECT TO | | | DESIGN PROFESSIONAL. THIS IS ONLY A | | | NOTICE GIVEN AT THIS TIME. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF ELECTRICAL IS BEING RETAINED | | | FOR FILE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-12 |
Time |
09:17 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-01-12 |
Time |
08:55 |
Sent To |
P |
|
| Notes |
| 2005-01-12 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SHOW LOCATION OF ALL | | | SERVICE EQUIPMENT ON PLANS INCLUDING | | | PANELS AND IDENTIFY PANELS. 215.5 | | | | | | 2)NOTE: PLEASE SEE 310.15B6 FOR MIN | | | SEC'S FOR A 400A SERVICE. 240.4B | | | MIN 400MCM. | | | | | | 3)NOTE: PLEASE SEE #4'S SHOWN FROM | | | GUTTER TO 200A METERS.? PLEASE SEE | | | 310.15B6, #4 IS RATED FOR 100A'S ONLY. | | | | | | 4)NOTE: PLEASE SEE 230.72 FOR GROUPING | | | OF MAINS REQUIRED. | | | | | | 5)NOTE: PLEASE SEE ONE OF THE 200A | | | METER | | | CANS DO NOT INDICATE WHERE THIS IS | | | FEEDING?? 215.5 | | | | | | 6)NOTE: PLEASE SEE 250.6,250.24 AND | | | EQUIPMENT GROUNDING CONDUCTOR IS ONLY | | | INSTALLED AFTER THE FIRST MEANS OF | | | DISCONNECT. | | | | | | 7)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANELS. RISER INDICATES 60A SUB | | | PANEL AS MLO AND PANEL IS SHOWN AS MCB. | | | PLEASE ALSO SEE PANEL H SHOWS A 2P20A | | | FEED TO 60A SUB PANEL. | | | PLEASE ALSO SEE OCP FROM PANEL "H" TO | | | PANEL K, SHOWN AS 2P20A 1KW LOAD. | | | | | | 8)NOTE: PLEASE SEE 424.3B FIR MIN OCP | | | FOR AHU'S. PLEASE SEE THESE ARE SHOWN | | | AS | | | 2P20A W/ 1KW LOAD?? | | | | | | 9)NOTE: PLEASE SEE NEW FOOTER STEEL | | | REQUIRED TO BE PART OF THE GROUNDING | | | ELECTRODE SYSTEM. 250.50 | | | | | | 10)NOTE: PLEASE SEE CIRCUITING FOR BATH | | | GFI'S THESE ARE TO BE 20A, #12 PER | | | 210.11C3. | | | PLEASE SEE SOME SHOWN AS 15A ETC. | | | | | | 11)NOTE: PLEASE SEE 210.52C1 FOR | | | KITCHEN | | | COUNTERSPACE. | | | | | | 12)NOTE: PLEASE SEE 210.8A6, ALL | | | KITCHEN | | | COUNTERSPACE RECEPTS TO BE SHOWN AS | | | GFI. | | | | | | 13)NOTE: PLEASE SEE FBC CHAPTER 34 FOR | | | ADDITIONS AND REMODELS TO EXISTING | | | DWELLINGS. | | | SD'S AND GFI'S TO BE BROUGHT UP TO | | | CODE. | | | PLEASE SHOW ALL NEW AND ANY EXISTING | | | WHICH MEET CURRENT CODE. | | | | | | 14)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | | | | 15)NOTE: PLEASE SEE 250.66 FOR MIN GEC. | | | 1/0 MIN. | | | | | | 16)NOTE: PLEASE SEE 220.31B FOR LOAD | | | CALCULATIONS. | | | | | | 17)NOTE: PLEASE PROVIDE ROOM | | | DESIGNATIONS ON PLANS. | | | | | | 18)NOTE: PLEASE SEE ARC FAULT PROTECTION | | | IS TO BE UNDER THE 2002 NEC.210.12 | | | AFCI PROTECTION IS FOR ALL "OUTLETS, | | | SD'S LTS , FANS ETC. PLEASE SEE | | | CIRCUITING. | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE | | | BEEN REDLINED ON ONE SET OF PLANS FOR | | | AREAS OF NOTES. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS SHOWULD BE | | | SUBMITTED FOR REFERENCE ONLY. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-12 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-12 |
Time |
18:14 |
Sent To |
E |
|
| Notes |
| 2006-10-12 18:14:41 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
16:42 |
Sent To |
E |
|
| Notes |
| 2006-09-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-13 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-13 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2006-09-13 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
14:07 |
Sent To |
E |
|
| Notes |
| 2006-04-10 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-31 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-31 |
Time |
16:14 |
Sent To |
M |
|
| Notes |
| 2006-03-31 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-21 |
Time |
19:53 |
Sent To |
E |
|
| Notes |
| 2006-03-21 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-14 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-14 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2006-03-14 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-28 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-28 |
Time |
15:18 |
Sent To |
B |
|
| Notes |
| 2005-09-28 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-01 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-01 |
Time |
17:58 |
Sent To |
E |
|
| Notes |
| 2005-09-01 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-28 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-28 |
Time |
11:04 |
Sent To |
E |
|
| Notes |
| 2005-07-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-17 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-17 |
Time |
11:57 |
Sent To |
E |
|
| Notes |
| 2005-06-17 00:00:00 | TO ELEC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-08 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-08 |
Time |
15:46 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-05 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-05 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2005-01-05 00:00:00 | TO "E" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-03 |
Time |
10:15 |
Sent To |
Z |
|
| Notes |
| 2005-01-03 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-03 |
Time |
09:47 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-04-03 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-04-03 00:00:00 | *** PROVISO *** | | | 1) PROVIDE COMBUSTION AIR FOR GAS | | | CLOTHES DRYER, PER 2004 FBC/R M1701.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-08-16 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-08-16 |
Time |
09:53 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-08-16 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2005-08-16 00:00:00 | MECH.PLAN REVIEW: PROVISO: | | | | | | CHECK LIST 1/18/05 PRAFTER. | | | | | | 1. O/K | | | | | | 2. O/K | | | | | | 3. RETURN AIR OUT OF BEDROOM #2 AND #3 | | | TO 18/18 HALLR/A GRILL MUST CONTINUE | | | TO AHU #2. . | | | | | | 4. O/K | | | | | | 5. O/K | | | | | | 6. BEDROOM #1 BATH MUST HAVE EXHAUST. | | | 2003 FBC/M 402.3.1.ARCH. A.2 REFLECT | | | BATH ROOM TO BE LOCATED INT. WITH NO | | | EXHAUST. | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-15 |
Time |
07:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-07-15 |
Time |
07:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-01-18 |
Time |
11:38 |
Sent To |
B |
|
| Notes |
| 2005-01-18 00:00:00 | 1. NO ENERGY INFORMATION. | | | | | | 2. FIRST FLOOR SITTING ROOM REQUIRES | | | RETURN AIR.FBC/M 2001 601.4 . | | | | | | 3. RETURN AIR OUT OF BEDROOM #2 AND | | | #3 MUST BE EQUEAL TO TOTAL SUPPLY DUCTS | | | INTO BEDROOM AND CLOSIT/BATHROOM AREA. | | | FBC/M 2001 601.4. | | | | | | 4. RETURN AIR OUT OF BEDROOM #1 AND | | | OFFICE ARE TRANSFER DUCT, WITCH REQUIRE | | | 1.5 TIMES THE CROSS SECTINAL AREA OF | | | SUPPLY AIR DUCTS.FBC/M 2001 601.4 | | | EXCEPTION #1 . | | | | | | 5. A/C COMP. UNIT FOR MASTER BEDROOM | | | AREA NOT REFLECTED ON PLAN . | | | | | | 6.WINDOW IN BATHROOM #1 MUST CONFORM | | | WITH FBC/M 402.3.1 EXCEPTION, WITH MIN. | | | OF 3 SQ. FT. OF OPENING SPACE. | | | PAT RAFTER 561/805/6725 OR 8056719 . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-09 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-08-16 |
Time |
09:52 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-06-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-06-25 |
Time |
09:20 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-06-25 |
Time |
09:20 |
Sent To |
M |
|
| Notes |
| 2005-06-25 00:00:00 | DENIED; | | | IS WATER HEATER GAS OR ELECTRIC? P.1 | | | SHOWS 40 GAL. LOW BOY, E.1 SHOWS GAS | | | WATER HEATER. WATER HEATER IS UNDER | | | SIZED FOR A 4 AND 1/2 BATHROOM HOME. IS | | | THERE ANOTHER WATER HEATER? | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-15 |
Time |
07:21 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-01-15 |
Time |
07:20 |
Sent To |
M |
|
| Notes |
| 2005-01-15 00:00:00 | DENIED; | | | RISER DIAGRAMS; | | | A.FIRST FLOOR, KITCHEN AND W/M TO | | | DISCHARGE DOWN STREAM OF 1/2 BATH. | | | TOILET NOT VENTED. | | | B.BATH 2 LAV. TO VENT WATER CLOSET SEE | | | RED LINE ON RISER DIAGRAM. | | | C.MASTER BATH, TUB TO DRAIN TO VENTED | | | LINE SEE RED LINE. | | | SHOWLOCATION OF 2ND FLOOR RISERS ON | | | 1ST FL FLAT PLAN PAGE P.1 | | | PLEASE PUT PAGES IN ORDER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-03 |
Time |
11:48 |
Sent To |
I |
|
| Notes |
| 2006-04-03 00:00:00 | REVISION - CHANGE IN DRIVEWAY/PATIO TYPE | | | TO PAVERS AND CHANGE IN DIMENSION OF | | | DRIVEWAY ONLY. | | | | | | NOTE: CALL TWICE FOR CLARIFICATION AND | | | NO RETURNED CALL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-17 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-17 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2005-10-17 00:00:00 | DENIED, | | | 1. MUST PULL A SEPERATE PERMIT FOR SITE | | | WALL WITH EASEMENT APPROVAL FROM THE | | | CITY OF WEST PALM UTILITY DEPT. | | | 2. PLEASE PROVIDE A COPY OF A SURVEY FOR | | | THE PROPOSED SITE WALL. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-16 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-16 |
Time |
19:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-04 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-04 |
Time |
16:44 |
Sent To |
I |
|
| Notes |
| 2005-01-04 00:00:00 | DENIED, MUST PROVIDE TWO COPY OF SURVEY | | | SHOWING THE EXISTING STRUCTURE TO | | | COMPARE WHAT'S BEING ADDED.CALLED | | | OWNER LEFT MSG ON VOICE MAIL. |
|
|