| Plan Review Stops For Permit 04121739 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-16 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-16 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2005-03-16 00:00:00 | PROVISO | | | | | | STORM PANELS WILL BE UNDER A SEPARATE | | | PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-13 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-13 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | DENIED | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PLAN SHEETS SD1 AND SD2 DO NOT HAVE | | | THE ORIGINAL WET SIGNATURE OF THE | | | ENGINEER AS REQUIRED BY FAC | | | 61G15-23.002. | | | | | | 3) ON SHEET RF-1 THE UPLIFT VALUE FOR | | | THE USC 53 CONNECTOR INCLUDES THE ONE | | | THIRD INCREASE IN THE STEEL | | | CALCULATIONS | | | WHICH IS NOT ALLOWED BY FBC 1609.4.3. | | | THE MAXIMUM UPLIFT IS 11,150# PER | | | MANUFACTURER'S CATALOG. | | | | | | 4) SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS, KEY PLANS AND INSTALLATION | | | SCHEDULES FOR THE STORM PANELS OR APPLY | | | UNDER A SEPARATE PERMIT. | | | | | | 5) THE PRODUCT APPROVALS FOR THE GARAGE | | | DOORS HAVE THE WRONG EVALUATION | | | REPORTS. | | | SUBMIT THE PROPER EVALUATION/TEST | | | REPORT | | | AND INSTALLATION INSTRUCTIONS THAT ARE | | | POSTED ON THE STATE PRODUCT APPROVAL | | | WEBSITE. | | | | | | 6) THE MIAMI-DADE NOA FOR THERMA-TRU | | | CORPORATION ATTACHED TO THE STATE | | | PRODUCT APPROVAL FOR BENCHMARK APPEAR | | | TO | | | BE TWO DIFFERENT PRODUCTS. SUBMIT | | | DOCUMENTATION THAT THESE ARE THEY SAME | | | COMPANY AND THE SAME PRODUCT. | | | | | | 7) SUBMIT STATE/LOCAL PRODUCT APPROVAL | | | FOR STRUCTURAL WINDOW MULLIONS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-30 |
Time |
19:23 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-12-30 |
Time |
19:23 |
Sent To |
M |
|
| Notes |
| 2004-12-30 00:00:00 | STAMPED ON PLANS. | | | | | | | | | ***** ALL REVISIONS AND OPTIONS | | | ARE TO BE RESUBMITTED FOR | | | REVIEW BEFORE ROUGH. ********** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-03 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-03 |
Time |
10:34 |
Sent To |
M |
|
| Notes |
| 2005-03-03 00:00:00 | TO PKRAUSS BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-30 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-30 |
Time |
14:51 |
Sent To |
E |
|
| Notes |
| 2004-12-30 00:00:00 | TO "SFD" RACK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
09:54 |
Sent To |
Z |
|
| Notes |
| 2004-12-29 00:00:00 | TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-14 |
Time |
06:55 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-03-11 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-10 |
Time |
F |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-10 |
Time |
08:05 |
Sent To |
B |
|
| Notes |
| 2005-01-10 00:00:00 | CALLED SABATELLO DEVELOPMENT CORP. INC. | | | ON 1/3/05 FOR REVISED A/C PLANS, AS | | | 1/10/05 NO PLANS. | | | PAT RAFTER 561/805/6725 OR 805/6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-03 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-01-03 |
Time |
10:08 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-30 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-30 |
Time |
14:28 |
Sent To |
I |
|
| Notes |
|
|