| Plan Review Stops For Permit 04121387 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-16 |
Time |
11:40 |
Rev Time |
0.25 |
| Received By |
alange |
Date |
2005-02-16 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-11 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-02-11 |
Time |
13:38 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-02-11 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-13 |
Time |
13:08 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-01-13 |
Time |
13:06 |
Sent To |
Z |
|
| Notes |
| 2005-01-13 00:00:00 | DENIED | | | | | | | | | | | | 1.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.WINDOWS 2-4 SH DO NOT MEET EGRESS | | | REQUIREMENTS. FBC 1005.4.4 | | | | | | 3.WINDOW AT TUB LOCATION REQUIRED TO | | | BE SAFTEY GLAZING FBC 2405.2.1 | | | | | | 4.SUBMIT 2 COPIES OF PRODUCT | | | APPROVALS | | | FOR THE FOLLOWING: | | | WINDOWS, STRAPS AND TIE-DOWNS AND | | | IMPACT | | | PROTECTION. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.IMPACT PROTECTION OR IMPACT GLASS | | | REQUIRED. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-15 |
Time |
04:37 |
Rev Time |
0.15 |
| Received By |
dpalmer |
Date |
2005-02-15 |
Time |
04:33 |
Sent To |
B |
|
| Notes |
| 2005-02-15 00:00:00 | PLANS REDLINED FOR 210.52 AND 110.26 | | | | | | PLANS SENT TO BLDG FOR PROCESSING. (NEW | | | BLDG SHEET). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-08 |
Time |
17:57 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-08 |
Time |
17:57 |
Sent To |
B |
|
| Notes |
| 2005-02-08 00:00:00 | ********* UNSAT *********** | | | | | | PLEASE SEE NOTES # 2 AND 4 FROM | | | PREVIOUS REVIEW. | | | | | | 1)NOTE: PLEASE SEE PLANS NEED TO | | | INDICATE ALL ITEMS EITHER NEW OR | | | EXISTING. SOME ELECTRICAL SHOWN BUT | | | THERE IS NO INDICATION? APPL MENTIONS | | | NEW CEILING FANS LTS TECYET, NOTHING | | | IS SHOWN FOR ANY OF THESE. LOCATIONS OF | | | BOXES, SWITCHES? | | | | | | 2)NOTE: PLEASE SEE2002 NEC FOR MIN | | | REQUIRED. 210.12 FOR ARC FAULT FOR NEW | | | IN BEDRMS. | | | 210.70 FOR EGRESS LIGHTING, NEW ? | | | EXISTING? LOCATIONS? | | | 210.52 FOR RECEPT SPACING TO BE BROUGHT | | | UP TO CODE OR EXISTING MEETS CODE? | | | PLANS DO NOT INDICATE RECEPT SPACING | | | MEETING CODE. | | | | | | 3)NOTE: **NOTE** PANEL LOCATION SHOWN | | | DOES NOT MEETS 110.26, PLEASE VERIFY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-30 |
Time |
14:50 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-12-30 |
Time |
14:50 |
Sent To |
P |
|
| Notes |
| 2004-12-30 00:00:00 | **************** UNSAT *************** | | | | | | | | | 1)NOTE:SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | PLANS ONLY SHOWN ONE SD? | | | | | | 2)NOTE: PLEASE SEE 210.52 FOR MIN RECEPT | | | SPACING. PLANS SHOWS MANY WALLS TO BE | | | DRYWALLED W/OUT NAY VERIFICATION ON | | | WHEATHER RECEPTS ARE EXISITNG OR TO BE | | | NEW.? | | | | | | 3)NOTE: PLEASE SEE BATH RMS ARE SHOWN W/ | | | NEW GFI'S. THESE NEED TO NOTED FOR | | | #12,20A. 210.11C3 | | | | | | 4)NOTE: PLEASE SEE DUE TO WORK AS | | | DESCRIBED ON APPLICATION, IT APPEARS | | | HOUSE MAY BE GETTTING RE-WIRED? IF SO | | | PLEASE SHOW MIN ELECTRICAL PER 2002 NEC | | | PLEASE INDICATE NEW OR EXISTING PANEL | | | AND SIZE.? | | | 215.5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
09:07 |
Sent To |
E |
|
| Notes |
| 2005-02-16 00:00:00 | TO DPALMER DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-07 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-07 |
Time |
08:39 |
Sent To |
Z |
|
| Notes |
| 2005-02-07 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-02 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-02 |
Time |
10:56 |
Sent To |
E |
|
| Notes |
| 2005-02-02 00:00:00 | TO "E"BOX/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-28 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-28 |
Time |
08:24 |
Sent To |
E |
|
| Notes |
| 2004-12-28 00:00:00 | TO "E" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-01-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-01-04 |
Time |
16:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-03 |
Time |
11:00 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-01-03 |
Time |
11:00 |
Sent To |
M |
|
| Notes |
| 2005-01-03 00:00:00 | FIXTURE CHANGEOUT ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-08 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-08 |
Time |
13:31 |
Sent To |
I |
|
| Notes |
| 2005-02-08 00:00:00 | NO ADDITION TO STRUCTURE.MUST PULL | | | SEPERATE PERMIT FOR FENCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-18 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-18 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | DENIED, NEED TO PROVIDE TWO COPY OF | | | SURVEY SHOWING THE ADDITION.(NEW | | | BAYWINDOW ADDITION).NEED TO PULL | | | SEPERATE PERMIT FOR FENCE & PROVIDE | | | EASEMENT RELEASE (UTILITY) APPROVAL WITH | | | SURVEY SHOWING THE LOCATION OF FENCE. | | | CALLED CONTR FILE N FOR P/U MM |
|
|