| Plan Review Stops For Permit 04121254 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-13 |
Time |
16:08 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2006-07-13 |
Time |
16:08 |
Sent To |
M |
|
| Notes |
| 2006-07-13 00:00:00 | DELETE WALL RATING OF STAIR AT | | | MEZZANINE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-01 |
Time |
10:05 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-01 |
Time |
10:05 |
Sent To |
ENG |
|
| Notes |
| 2006-06-01 00:00:00 | REVISION CHANGE IN HANDICAPPED ACCESS | | | RAMP AND SIDEWALK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-02 |
Time |
12:43 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2006-05-02 |
Time |
12:27 |
Sent To |
PC |
|
| Notes |
| 2006-05-02 00:00:00 | ROOFING 04121255 BUTLER VSR METAL ROOF |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
F |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-19 |
Time |
17:53 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-04-19 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04121254 | | | ADD: 1318 MERCER AV | | | CONT:SOUTHERN CONSTRUCTION | | | TEL: (561)718-8876 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ROOF SUBMITTAL | | | ACTION: DENIED | | | | | | 1) SUBMIT THE PTID 4897 I BUTLER NS ROOF | | | UL TEST . PDF FILE FOR THE APPLICATION | | | TO BE USED ON THIS PROJECT. EITHER | | | SYSTEM TEST: | | | 345 | | | 345A | | | 483.2 | | | 2) DESIGN PROFESSIONAL TO REVIEW PRODUCT | | | TESTING. DESIGN PRESSURE OF 52.5 | | | ZONES 2 & 3 TO BE REVIEWED BY THE DESIGN | | | PROFESSIONAL INCREASED DESIGN PRESSURE | | | AT PERIMETER AND CORNERS MAY BE MET BY | | | RATIONAL ANALYSIS BY DESIGN | | | PROFESSIONAL. | | | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-03 |
Time |
10:55 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-04-03 |
Time |
10:55 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | REVISION: 14' WIDE ROLL UP DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-27 |
Time |
12:11 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2006-02-27 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | DETAIL LG02 FLANGE W BRACE TO "W" | | | SECTION | | | | | | STRUCTURAL ROOF DETAIL , 18 GA MTL | | | TRUSSES & TAPCONS | | | | | | WALL SECONDARY STRUCTURAL ELEVARION | | | DETAIL10-24-05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-06 |
Time |
11:03 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2006-02-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2006-02-06 00:00:00 | REV SK1-12 JAN 06, SK 1-4 JAN 06 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-17 |
Time |
09:51 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-01-17 |
Time |
09:51 |
Sent To |
PC |
|
| Notes |
| 2006-01-17 00:00:00 | STRUCTURAL DETAIL SHEET8-21-05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
10:45 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-12-23 |
Time |
10:45 |
Sent To |
PC |
|
| Notes |
| 2005-12-23 00:00:00 | 12-23-05 REVISIONS: | | | 1) YKK STOREFRONT | | | 2) YKK EXT DOORS | | | 3) STRUCTURAL REPAIR12-14-05SHEET "A-B" |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-16 |
Time |
15:53 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-12-16 |
Time |
15:53 |
Sent To |
PC |
|
| Notes |
| 2005-12-16 00:00:00 | VARIOUS SUBMITTALSDAILY REPORTS, | | | CORRECTION REPORTS, |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2005-11-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-29 |
Time |
15:02 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-11-29 |
Time |
15:02 |
Sent To |
PC |
|
| Notes |
| 2005-11-29 00:00:00 | SUBMITTAL# 10 PURLIN BRACES | | | PURLIN CONN TO TILT WALL | | | LETTER FOR MODIFICATIONS GIRT CLIP | | | 6"X6" WALL ANGLE APPROVAL FROM ENG | | | 1/2" FASTENER APPROVAL | | | SHIM APPROVALS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-20 |
Time |
13:14 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-08-20 |
Time |
13:14 |
Sent To |
PC |
|
| Notes |
| 2005-08-20 00:00:00 | 8-20-05 SUBMITTALS | | | REV PANEL P57 | | | ROOF SECONDARY FRAMING PLAN | | | 123135 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2005-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-20 |
Time |
11:18 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-08-20 |
Time |
11:18 |
Sent To |
PC |
|
| Notes |
| 2005-08-20 00:00:00 | 08-20-05 THE FOLLOWING SUBMITTALS WERE | | | REVIEWED: | | | 1) TIT WALL ENGINEERING BOOK PANELS | | | 2) TILT WALL SHOP DRAWINGS 4-21-05 | | | 3) TILT WALL PANEL REVISIONS 7-27-05 | | | 4) REV: 7-12-05 RFI 15 | | | 5) TILT WALL REV 8-08-05 | | | 6) REV 8-03-05 REFS5.0-5.1.-.2-5.3 | | | 7) REV 5-18-05 LDT ANCHORS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2005-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-07-20 |
Time |
07:40 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-07-20 |
Time |
07:40 |
Sent To |
PC |
|
| Notes |
| 2005-07-20 00:00:00 | STRUCTURAL STEEL CLARIFICATIONS, | | | REVISED SECTION 1/S2.0, | | | FIELD REPORT #2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-06-28 |
Time |
07:17 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-06-28 |
Time |
07:17 |
Sent To |
PC |
|
| Notes |
| 2005-06-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04121254 | | | ADD: 1318 MERCER AVE | | | CONT: SOUTHERN CONST | | | TEL: (561)881-8091 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET SKI-22MAY05 PEIR DETAIL HAS | | | HAND WRITTEN INFORMATION NOT SIGNED BY | | | P.E. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-05-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-05-04 |
Time |
14:25 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-05-04 |
Time |
14:25 |
Sent To |
PC |
|
| Notes |
| 2005-05-04 00:00:00 | 05-04-05 SHOP DRAWINGSOK JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-19 |
Time |
07:02 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2005-04-19 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2005-04-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT:04121254 | | | ADD:1318 MERCER AV | | | CONT:SOUTHERN CONSTRUCTION | | | TEL: (561)881-8091 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEW | | | ACTION: DENIED | | | | | | 1) SHOP DRAWINGS ARE REQUIRED TO BE | | | REVIEWED BY THE DESIGNER OF RECORD AND | | | APPROVED, APPROVED WITH CORRECTIONS | | | BEFORE SUBMITTAL TO THE BUILDING | | | DEPARTMENT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-04-04 |
Time |
09:32 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-04-04 |
Time |
09:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-03-21 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-03-21 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | PERMIT: 04121254 | | | ADD: 1318 MERCER AVE | | | CONT: SOUTHERN CONSTRUCTION | | | TEL: (561)718-8876 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | 1) THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | IT MAY REQUIRE REPLATTING, SINCE THE | | | SURVEY INDICATES 6 LOTS THAT WOULD | | | REQUIRE COMBINING INTO ONE LOT. | | | | | | 2) FBC* 105.3RESIDENT INSPECTOR. | | | SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA (805-6711), | | | DIRECTOR OF THE RESIDENT INSPECTOR | | | PROGRAM.A RESIDENT INSPECTOR PROGRAM | | | IS REQUIRED, ON THIS PROJECT, DUE TO ONE | | | OR MORE OF THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION. | | | | | | 3) SINCE THIS BUILDING REQUIRES A | | | SPECIAL INSPECTOR, SUBMIT (3) SETS OF | | | ALL DOCUMENTS, PLANS, REPORTS, PRODUCT | | | APPROVALS, LETTERS AND OR SUBMITTALS . | | | | | | | | | 4) THE PLANS SUBMITTED FROM BUTLER | | | MANUFACTURING COMPANY SHALL REQUIRE THE | | | PLANS TO BE SIGNED WITH ORIGINAL | | | SIGNATURE OF THE P.E., ALL 3 SETS NOT | | | COPIES OF SIGNATURES.SIGNED & SEALED. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 5) A2.2 ROOF RACK HEIGHT:THE A?C RACK | | | DETAIL INDICATES A MINIMUM OF 18" BUT | | | DOES NOT PROVIDE INFORMATION IF THE UNIT | | | IS 38" WIDE AS PROVIDED BY TABLE 1511.7. | | | 1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 6) TABLE 600 ISSUES SEE TYPEIV BLDG | | | UNPROTECTED, FOOTNOTE (E) UNDER ROOF & | | | ROOF CEILING ASSEMBLIES. ONLY FIRE | | | RETARDANT TREATED WOOD CAN BE USED FOR | | | SHEATHING ON BUILDINGS 2 STORIES OR | | | LESS. SEE SHEET S0.2 NOTES PLYWOOD ROOF | | | DECKING, ALSO S2.1 SECTION 5&6 PLEASE | | | ANNOTE PLANS. | | | | | | 7) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 3 COPIES OF THE | | | PRODUCT APPROVAL FOR THRESHOLD OR | | | RESIDENT INSPECTOR PROGRAM BUILDING. | | | | | | 8) PROVIDE THE PALM BEACH COUNTY IMPACT | | | FEE RECEIPT, PART OF PERMIT PACKAGE | | | REQUIREMENTS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-20 |
Time |
13:36 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2005-01-20 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04121254 | | | ADD: 1318 MERCER AVE | | | CONT: SOUTHERN CONSTRUCTION | | | TEL: (561)718-8876 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | 1) THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | IT MAY REQUIRE REPLATTING, SINCE THE | | | SURVEY INDICATES 6 LOTS THAT WOULD | | | REQUIRE COMBINING INTO ONE LOT. | | | | | | 2) FBC* 105.3RESIDENT INSPECTOR. | | | SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA (805-6711), | | | DIRECTOR OF THE RESIDENT INSPECTOR | | | PROGRAM.A RESIDENT INSPECTOR PROGRAM | | | IS REQUIRED, ON THIS PROJECT, DUE TO ONE | | | OR MORE OF THE FOLLOWING: | | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | - BUILDINGS OVER 20,000 SQFT IN AREA | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION. | | | | | | 3) SINCE THIS BUILDING REQUIRES A | | | SPECIAL INSPECTOR, SUBMIT (3) SETS OF | | | ALL DOCUMENTS, PLANS, REPORTS, PRODUCT | | | APPROVALS, LETTERS AND OR SUBMITTALS . | | | | | | | | | 4) SUBMIT A THIRD SET OF ENERGY | | | CALCULATIONS. | | | | | | 5) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | A SINGLE SIGNED & SEALED REPORT WAS | | | SUBMITTED, (3) ORIGINAL SIGNED AND | | | SEALED REPORTS ARE REQUIRED. | | | | | | 6) THE PLANS SUBMITTED FROM BUTLER | | | MANUFACTURING COMPANY SHALL REQUIRE THE | | | PLANS TO BE SIGNED WITH ORIGINAL | | | SIGNATURE OF THE P.E., ALL 3 SETS NOT | | | COPIES OF SIGNATURES.SIGNED & SEALED. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 7) SEE SHEETS A-2.1 & A-3 FOR REQUIRED | | | CLEARENCES AT THE PULL SIDE DOORS: | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 8) A2.2 ROOF RACK HEIGHT SEE: | | | 1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 9) FBC* F102.2.7ARCHITECTURAL TRIM, ON | | | BUILDINGS LOCATED IN THE FIRE DISTRICT, | | | SHALL BE CONSTRUCTED OF APPROVED | | | NON-COMBUSTIBLE MATERIALS OR FIRE | | | RETARDANT TREATED WOOD.ANNOTATE THE | | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | | | 10A) SHEET A-8 PROVIDE U.L. LISTING# | | | G350 FOR A 2 HR FLOOR/ CEILING ASSEMBLY | | | NOT IN 2004 LISTINGS. | | | 10B) THE SAME SHEET MISSING WALL DESIGN | | | U.L. LISTING# U-465 FOR A (2)HR RATING, | | | U.L. INDICATES A 1 HR RATING. | | | | | | 11) A-9 STEEL BEAM PROTECTION PROVIDE | | | THE U.L. LISTING FOR N306 , NOT IN 2004 | | | | | | LISTING BOOK. | | | | | | 12) TABLE 600 ISSUES SEE TYPEIV BLDG | | | UNPROTECTED, FOOTNOTE (E) UNDER ROOF & | | | ROOF CEILING ASSEMBLIES. ONLY FIRE | | | RETARDANT TREATED WOOD CAN BE USED FOR | | | SHEATHING ON BUILDINGS 2 STORIES OR | | | LESS. SEE SHEET S0.2 NOTES PLYWOOD ROOF | | | DECKING, ALSO S2.1 SECTION 5&6 PLEASE | | | ANNOTE PLANS. | | | | | | 13) S-2.1 DETAIL# 4, ADD INFORMATION AS | | | WHAT TYPE OF MATERIAL IS USED ON THE END | | | OF THE GIRDER TRUSS. | | | | | | 14) SHEET S4.0 HEADER FOR PREENGINEERED | | | | | | METAL BUILDING DESIGN BASIS- MISSING | | | WHAT BUILDING CODE DESIGNED UNDER? | | | | | | 15)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 16) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 3 COPIES OF THE | | | PRODUCT APPROVAL FOR THRESHOLD OR | | | RESIDENT INSPECTOR PROGRAM BUILDING. | | | | | | 17) PROVIDE THE PALM BEACH COUNTY IMPACT | | | FEE RECEIPT, PART OF PERMIT PACKAGE | | | REQUIREMENTS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-04 |
Time |
07:27 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-03-04 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2005-03-04 00:00:00 | SITE LIGHTING UNDER SEPARATE PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-05 |
Time |
16:53 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-01-05 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2005-01-05 00:00:00 | ********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE NOTE ON PLANS | | | MENTIONS WIND LOADING FOR LT POLES AND | | | FIXTURES TO BE PROVIDED BY CONTRACTOR. | | | THIS SI REQUIRED AT THIS TIME AND TO BE | | | A PART OF THIS PLAN REVIEW PROCESS. | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE. | | | PLEASE SEE 700.12E FOR CIRCUTING OF | | | EM/EXT LTS. PANEL SCHEDULE INDICATES | | | EM/EXT LTS ON INDIVIDUAL CIRCUIT.THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 3)NOTE: PLEASE SEE FAC 61G15-23.002, | | | WHICH ALSO REQUIRES THE PRINTED ANEM OF | | | THE ENGINEER ON TITLE BLOCK. | | | | | | 4)NOTE:PLEASE SEE 600.5 FOR REQUUIRED | | | SIGN CIRCUIT.EACH COMMERCIAL BUILDING | | | AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE | | | TO PEDESTRIANS SHALL BE PROVIDED WITH AT | | | LEAST ONE OUTLET IN AN ACCESSIBLE | | | LOCATION AT EACH ENTRANCE TO EACH TENANT | | | SPACE FOR SIGN OR OUTLINE LIGHTING | | | SYSTEM USE. THE OUTLET(S) SHALL BE | | | SUPPLIED BY A BRANCH CIRCUIT RATED AT | | | LEAST 20 AMPERES THAT SUPPLIES NO OTHER | | | LOAD. SERVICE HALLWAYS OR CORRIDORS | | | SHALL NOT BE CONSIDERED ACCESSIBLE TO | | | PEDESTRIANS. | | | | | | PLEASE REMOVE ALL OLD/ VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-06-01 |
Time |
|
Rev Time |
0.75 |
| Received By |
|
Date |
2006-06-01 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2005-03-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-03-15 |
Time |
12:08 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-03-15 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2005-03-01 00:00:00 | PASSED WITH PROVISOS: | | | | | | 1. THE SURVEY DATA FOR THE EXISTING | | | WATER, SEWER, AND STORM WATER AS | | | REQUESTED BY THE PUBLIC UTILITIES AND | | | ENGINEERING MUST BE SUBMITTED PRIOR TO | | | OR AT PRE-CONSTRUCTION MEETING , SEE | | | LETTER BY MR. KEVIN E. KRUT OF EAST BAY | | | GROUP,LLC. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-12-30 |
Time |
09:43 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-12-30 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT CIVIL PLANS FOR OUR | | | REVIEW AND APPROVAL, INCLUDE STORM WATER | | | CALCULATION FOR THE PROPOSED SITE | | | IMPROVEMENTS. | | | 2. PLEASE CONTACT MR. MANNY GONZALEZ @ | | | 494-1085, PUBLIC UTILITIES AND | | | ENGINEERING SERVICES FOR ALL THE | | | CONNECTIONS TO THE CITY SERVICES. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-24 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-24 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2005-03-28 00:00:00 | P-PROVISO | | | | | | 1) PLEASE BE ADVISED THAT ALL WORK MUST | | | COMPLY WITH NFPA 13, 2002 EDITION WHEN | | | SEPARATE SHOP DRAWINGS ARE SUBMITTED. | | | THIS OFFICE ADOPTED THE 2002 EDITION | | | AFTER JAN. 1, 2005. | | | | | | 2) A WRENCH SHALL BE PROVIDED WITH THE | | | SPARE SPRINKLER HEADS. | | | | | | 3) PLEASE BE ADVISED THAT THE FIRE | | | SPRINKLER SYSTEM SHALL BE MONITORED BY A | | | MONITORING COMPANY APPROVED AS A UL | | | LISTED CENTRAL STATION SERVICE. | | | | | | 4) PLEASE BE ADVISED THAT SEPARATE SHOP | | | DRAWINGS AND PERMITS ARE REQUIRED FOR | | | FIRE SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR (561) 835-2910 | | 2005-03-24 00:00:00 | P-PROVISO | | | | | | THANK YOU FOR YOUR EXPLANATIONS | | | RERGARDING THE ORIGINAL REVIEW, HOWEVER | | | ITEM #8 REQUIRES ADDITIONAL | | | CLARIFICATION. | | | | | | 1) PLEASE BE ADVISED THAT SEPARATE SHOP | | | DRAWINGS AND PERMITS ARE REQUIRED FOR | | | BOTH THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS. SHEET E-2 ONLY REFERS TO THE | | | FIRE ALARM SYSTEM. | | | | | | | | | MIKE WENNERGREN, A/CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-24 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-24 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | 1) DEMOLITION, RENOVATION AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3) BUILDING ADDRESS REQUIRED. A MINIMUM | | | OF AT LEAST 6" HIGH NUMBERS ARE | | | REQUIRED. | | | | | | 4) PLEASE PROVIDE ENGINEERED FIRE | | | SPRINKLER DRAWINGS AND FLOW | | | CALCULATIONS. | | | | | | 5) THE FIRE ALARM SYSTEM SHALL BE | | | MONITORED BY A LICENSED UL LISTED FIRE | | | ALARM COMPANY FOR CENTRAL STATION | | | SERVICE. | | | | | | 6) THE FIRE ALARM SYSTEM SHALL BE CLASS | | | "A" OR FULLY ADDRESSABLE. | | | | | | 7) ALL NEW FIRE ALARM SYSTEMS THAT | | | SUPERVISE FIRE SPRINKLER SYSTEMS SHALL | | | BE UL CERTIFICATED AND HAVE DOCUMENTS | | | ATTESTING TO THIS CERTIFICATION PRIOR TO | | | FINAL APPROVAL OF THE FIRE ALARM | | | SYSTEM. | | | | | | 8) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER SYSTEMS. | | | | | | | | | NATE MCCRAY, CAPTAIN | | | 561-835-2910 OR 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-11 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-11 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2006-08-11 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-26 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-26 |
Time |
15:02 |
Sent To |
M |
|
| Notes |
| 2006-06-26 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
15:52 |
Sent To |
M |
|
| Notes |
| 2006-05-30 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
| 2006-05-30 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2006-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-29 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-29 |
Time |
15:44 |
Sent To |
B |
|
| Notes |
| 2006-04-29 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-11 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-11 |
Time |
09:04 |
Sent To |
B |
|
| Notes |
| 2006-04-11 00:00:00 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-03 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-03 |
Time |
11:11 |
Sent To |
M |
|
| Notes |
| 2006-04-03 00:00:00 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-28 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-28 |
Time |
15:50 |
Sent To |
B |
|
| Notes |
| 2006-03-28 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-17 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-17 |
Time |
14:58 |
Sent To |
B |
|
| Notes |
| 2006-02-17 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:01 |
Sent To |
B |
|
| Notes |
| 2006-01-22 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2006-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-04 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-04 |
Time |
13:46 |
Sent To |
B |
|
| Notes |
| 2006-01-04 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-20 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-20 |
Time |
17:09 |
Sent To |
B |
|
| Notes |
| 2005-12-20 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2005-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-16 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-16 |
Time |
14:42 |
Sent To |
B |
|
| Notes |
| 2005-12-16 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2005-11-18 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-19 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-19 |
Time |
16:01 |
Sent To |
B |
|
| Notes |
| 2005-10-19 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
| 2005-08-18 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-09 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-09 |
Time |
16:02 |
Sent To |
B |
|
| Notes |
| 2005-08-09 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-04 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-04 |
Time |
16:06 |
Sent To |
B |
|
| Notes |
| 2005-08-04 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-03 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
13:02 |
Sent To |
B |
|
| Notes |
| 2005-08-03 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-29 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-29 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
| 2005-07-29 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
13:43 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | TO "JWITMER" DESK/SUBMITTAL | | | 1 ROLL SHOP DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
11:50 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-26 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-26 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-14 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-14 |
Time |
16:36 |
Sent To |
B |
|
| Notes |
| 2005-07-14 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
10:50 |
Sent To |
I |
|
| Notes |
| 2005-07-13 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2005-07-01 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-24 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-24 |
Time |
08:29 |
Sent To |
B |
|
| Notes |
| 2005-06-24 00:00:00 | TO "JWITMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-22 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-22 |
Time |
10:28 |
Sent To |
B |
|
| Notes |
| 2005-04-22 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2005-04-15 00:00:00 | TO "JWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-03 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-28 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2005-02-28 00:00:00 | TO "COMM" BD#48 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-22 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2004-12-22 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2004-12-22 00:00:00 | SENT TO "COMM BD#56 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-08-15 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-08-15 |
Time |
09:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-14 |
Time |
08:26 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-07-14 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2006-07-14 00:00:00 | REVISION TO MECH. PAGE M-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-27 |
Time |
09:31 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-06-27 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | REVISION TO MACH. PAGE M-1 PASSED. | | | *** REVISION TO MECH PAGE M-2 DENIED *** | | | 1) MECHANICAL ROOM ON MEZZANINE HAS A 1 | | | HOUR RATED WALL AND REQUIRES FIRE | | | DAMPERS, PLEASE SEE ARCHITECTURAL PLANS | | | PAGE A-2.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-02 |
Time |
09:57 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-06-02 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | REVISION TO MECH. PLANS PAGE M-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-04 |
Time |
09:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-04-04 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-04-04 00:00:00 | REVISION TO MECH. PLANS BY A SUBMITTAL | | | LETTER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-25 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | REFER TO SECTION 307.2.3 AUXILIARY DRAIN | | | PANS FLORIDA BUILDING CODE (M) | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-05 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-01-05 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2005-01-05 00:00:00 | DENIED: | | | 1.PLAN SHEET A-8 DETAIL OF BUILDING | | | SECTION A SHOWS 2 HR RATED FLOOR/CEILING | | | ASSEMBLY UL #G350.THIS UL ASSEMBLY | | | NUMBER IS NOT SHOWN IN THE UL FIRE | | | RESISTANCE DIRECTORY. | | | | | | 2.PENDING THE ASSEMBLY OF THIS AREA, | | | FIRE DAMPERS AND RO RADIATION DAMPERS | | | MAY BE REQURIED. | | | | | | 3.PLEASE INDICATE WHAT TYPE OF WORK | | | AND STORAGE WILL BE IN THE WAREHOUSE | | | AREA AND AND THE DOOR SHOP AREA.PLEASE | | | INDICATE AND GASES, CHEMICALS OR | | | COMBUSTIBLES STORED OR USED IN THESE | | | AREAS. | | | | | | 4.PLEASE CLARIFY THE "WELDER" IN THE | | | "WOOD DOOR ASSEMBLY" AREA. | | | | | | 5.PLAN SHEET M-4 AHU HANGING DETAIL 1" | | | GALVENIZED DRAIN PAN, PER 2001 | | | FBC(M)307.2.3 AUXILIARY DRAIN PAN SHALL | | | BE A MINIMUM OF 1 1/2" DEEP AND NOT 1" | | | AS SHOWN ON THE PLAN. | | | | | | 6.PLAN SHEET M-4 INDICATES AHU HANGING | | | DETAIL SHOWS THE AHU SUPPORT TO THE | | | BOTTOM OF THE BAR JOIST.PROVIDE | | | ENGINEER LETTER AND MANUFACTURER'S | | | INSTALLATION SPECIFICATIONS SHOWING THIS | | | IS ACCEPTABLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-21 |
Time |
10:18 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-03-21 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-17 |
Time |
16:10 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2005-03-17 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2005-03-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | A) FROM PREVIOUS REVIEW: THE COMMENT | | | NUMBER SHALL STAY THE SAME TO AVOID | | | CONFUSTION. | | | 3) SUBMIT A DETAIL FOR THE KITCHEN AND | | | BREAK ROOM SINKS. SHOW COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. THE | | | FOLLOWING SUBSECTIONS WERE NOT SHOWN. | | | A) 11-4.24.4 SINK DEPTH | | | B) 11-R.24.5 27" MIN. HEIGHT FOR KNEE | | | CLEARANCE. | | | C) 11-4.24.6 EXPOSED PIPES & SURFACES. | | | D) 11-4.24.7 FAUCETS. | | | 4) SUBMIT A DETAIL FOR THE URINALS | | | SHOWING COMPLIANCE WITH SECTION 11-4.18 | | | AND ALL SUBSECTIONS. NOT SHOWN WAS: | | | A) 11-4.18.4 FLUSH CONTROLS. | | | 5) SUBMIT A DETAIL FOR THE SHOWER | | | SHOWING COMPLIANCE WITH SECTION 11-4.21 | | | AND ALL SUBSECTIONS. NOT SHOWN WAS: | | | A) 11-4.21.5 CONTROLS (HEIGHT NOT | | | SHOWN) | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-22 |
Time |
17:18 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2005-01-22 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2005-01-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) TABLE 403.1 MINIMUM FACILITIES | | | INDICATE THAT 3 DRINKING FOUNTAINS ARE | | | REQUIRED. PLANS INDICATE 2 SUPPLIED. | | | ALSO SEE SECTION 410.1. | | | 2) SUBMIT A DETAIL FOR DRINKING | | | FOUNTAINS SHOWING COMPLIANCE WITH | | | SECTION 11-4.15 AND ALL SUBSECTIONS. | | | ALSO SHOW COMPLIANCE WITH SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | 3) SUBMIT A DETAIL FOR THE KITCHEN AND | | | BREAK ROOM SINKS. SHOW COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. A | | | FORWARD APPROACH CLEAR FLOOR SPACE IS | | | REQUIRED. | | | 4) SUBMIT A DETAIL FOR THE URINALS | | | SHOWING COMPLIANCE WITH SECTION 11-4.18 | | | AND ALL SUBSECTIONS. | | | 5) SUBMIT A DETAIL FOR THE SHOWER | | | SHOWING COMPLIANCE WITH SECTION 11-4.21 | | | AND ALL SUBSECTIONS. | | | 6) SHT A-4 OF 14 SHOWS THE CLEAR FLOOR | | | SPACE AS 36"X42". MIN. CLEAR FLOOR SPACE | | | FOR SINKS IS 30"X48". SECTION 11-4.24.5. | | | THE CLEAR FLOOR SPACE ALSO INDICATES THE | | | CLEAR FLOOR SPACE AS A PARALLEL APPROACH | | | WHEN A FORWARD APPROACH IS REQUIRED. | | | 7) SHT A-5 OF 14 (SEE ABOVE COMMENT). | | | 8) SHTS P-1 & P-2 SANT. RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN. NO HAND | | | SINK IS SHOWN ON THE RISER DIAGRAM. | | | 9) SHT P-2 WATER RISER DIAGRAM. FULL | | | OPEN VALVES ARE REQUIRED ON TOP OF ALL | | | WATER DOWN-FEED PIPES. SEE ROOM 120 AND | | | JANITOR SINK BY STAIRS NEAR ROOM 120. | | | 10) SHT P-2 WATER RISER AND SANT. RISER | | | DIAGRAMS, THE P&T RELIEF LINES SHALL NOT | | | DRAIN INTO FUNNEL FLOOR DRAINS. FLOOR | | | DRAINS ARE NOT AN APPROVED INDIRECT | | | WASTE RECEPTOR. A FLOOR SINK OR A HUB | | | DRAIN IS REQUIRED. SECTIONS 802.3 AND | | | 802.3.2. | | | 11) SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR THE INSTA-HOT WATER HEATER SHOWN ON | | | THE WATER RISER DIAGRAM SHT P-2. LISTING | | | REQUIRED. SECTION 303.4. | | | 12) A SEPARATE PERMIT AND PLANS ARE | | | REQUIRED FOR THE IRRIGATION. PLUMBING | | | CONTRACTOR SHALL INSTALL BACKFLOW FOR | | | IRRIGATION. SECTION 104.3.1.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-03-28 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-03-28 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2005-03-28 00:00:00 | APPROVED BY RANDELL SEE PLANS FOR | | | SIGNATURE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-13 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-13 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2005-01-18 00:00:00 | AWAITING PLANS FROM RECORDS RETENTION | | | FOR REVIEWING.CALLED RGRANBERRY AT | | | 822-1454 MM | | 2005-01-13 00:00:00 | WAITING FOR THE LETTER THAT EXTENDS THE | | | DSI. CALL RANDALL GRANBERRY, PLANNER | | | 822-1454 MM |
|
|