| Plan Review Stops For Permit 04121040 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-05-26 |
Time |
20:42 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-05-26 |
Time |
20:42 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-04-06 |
Time |
15:59 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-04-06 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2009-01-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-14 |
Time |
12:55 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2009-01-14 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2009-01-14 13:28:54 | BUILDING PLAN REVIEW | | | PERMIT: 04121040 | | | ADD: 533 CLEMATIS ST | | | CONT: FIVE STAR CONTRACTING GROUP | | | TEL: (561)436-8508 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | W/ * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2001 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1D) PLANS WERE SUBMITTED AS A RESTAMP, BUT IN PULLING | | | THE ORIGINAL ISSUED PLANS, THIS IS NOT AN EXACT RESTAMP | | | BUT A REDESIGN BY THE NEW DESIGN TEAM, ADDITIONAL FEES | | | ARE DUE. | | | | | | 1E) NOTE THAT IN THE ISSUED SET OF DOCUMENTS ENERGY | | | CALCULATIONS WERE SUBMITTED, NO SUCH INFORMATION WAS | | | SUBMITTED UNDER THIS REVIEW. LOOK FOR MORE COMMENTS AS | | | TO THE REQUIREMENTS FROM EACH OF THE TRADES. | | | | | | 1F) PLLANS TO BE SUBMITTED FOR HISTORIC REVIEW AND | | | PLANS STAMPED BEFORE ISSUANCE. | | | | | | 2) COVERSHEET GENERAL NOTES: | | | | | | 2A) PLEASE REVISE THE EDITION OF THE CODE WHICH THE | | | PLANS WERE DESIGNED TO. THIS IS A 2004 PERMIT UNDER THE | | | 2001 FBC. PLEASE REVISE CODE RELATED ISSUES. | | | | | | 2B) THE DESIGNER IS INDICATING THE BUILDING TO BE FULLY | | | SPRINKLERED INCLUDING THIS SPACE BUT NO FIRE SPRINKLER | | | PLANS ARE INCLUDED WITHIN THIS PERMIT PACKAGE. 2001 FBC | | | 104.3.1.1(5) FIRE SPRINKLERS. | | | | | | 2C) THE COVER SHEET INDICATES THAT INTERIOR DESIGN | | | DRAWINGS ARE NOT REQUIRED, THE ONLY INFORMATION | | | PROVIDED IS MINIMUM INTERIOR FINISH CLASSIFICATION | | | TABLE 803.3. SECTION 803.3.1 THE MINIMUM FLAMESPREAD | | | CLASSIFICATION OF INTERIOR FINISH OTHER THAN FLOOR | | | FINISH AND FLOOR COVERINGS SHALL BE BASED ON THE USE OR | | | OCCUPANCY AS SET FORTH IN TABLE 803.3. NO INFORMATION | | | WAS SUPPLIED UNDER THIS REVIEW FOR FLOOR, WALL, TRIM | | | NOR CEILINGS. | | | | | | 2D) OCCUPANCY IS INDICATED AS 170 SEATS, OR IS THAT TO | | | BE THE TOTAL OCCUPANT LOAD? | | | | | | 3) SHEET 1.0A | | | | | | 3A) IT APPEARS THAT THE COOLER DOOR HAS BEEN CHANGED TO | | | A OUTSWING DOOR COVERING MORE THAN ONE HALF OF THE | | | REQUIRED EGRESS 2001 FBC 1012.1.4. | | | | | | 3B) PLEASE REVIEW 11-5.1 FIVE PER CENT OF SEATING ARE | | | TO BE ACCESSIBLE SEATS PLANS INDICATE 170 SEATS OR 9 | | | ACCESSIBLE SEATS, PLEASE RECOUNT SEATING IT APPEARS | | | THAT THERE ARE 146 SEATS REQUIRING 8 ACCESSABLE SEATS. | | | | | | 3C) PLEASE INDICATE THE ACCESIBLE ROUTE FOR THE | | | ACCESIBLE SEATING AREAS , THE MINIMUM CLEAR WIDTH OF AN | | | ACCESSIBLE ROUTE SHALL BE 36". 11-4.3.3. | | | | | | 3D) CONSTRUCTION NOTE# 5 INDICATES NEW FIXED STOREFRONT | | | WITH PRECAST LINTELS. THE PERMITED SET OF PLANS DID NOT | | | MENTION ANY WORK ON THE EXTERIOR OF THE BUILDING. | | | PLEASE PROVIDE INFORMATION AS TO WHERE THE NEW OPENINGS | | | AND LINTELS WILL BE INSTALLED. COMPONENTS AND CLADDING, | | | 1606.2.5, PROTECTION OF OPENINGS LARGE MISSILE IMPACT | | | GLAZING OR STORM PANELS 1606.1.4. | | | | | | 3E) FL BLD CODE 1609.1.4: & RULE 9B-72, COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS | | | ,MISSING REPORTS ARE AS FOLLOWS: | | | LINTELS | | | STOREFRONT- WINDOWS AND DOORS | | | | | | 3F) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. | | | | | | 3G) SINCE SHEET 1.0A NOTE 5 DOES INDICATE NEW | | | STOREFRONT PLEASE INDICATE WHERE THE FRONT PROPERTY | | | LINE IS LOCATED, SECTION 3203. | | | | | | 4) PLANS FAIL TO INDICATE OCCUPANCY SEPERATION BETWEEN | | | THE A2 OCCUPANCY AND THAT ABOVE. PLEASE PROVIDE | | | WHATTYPE OF OCCUPANCY IS LOCATED ON THE SECOND FLOOR. | | | TABLE 704.1 A2 ASSEMBLY 2HR. | | | PLEASE PROVIDE DETAILS. | | | | | | 5) HVAC PLAN INDICATES NEW WORK THROUGH THE HORIZONTAL | | | FLOOR/ CEILING ASSEMBLY PLEASE INDICATE COMPLIANCE WITH | | | 705.6 PENETRATIONS OF HORIZONTAL ASSEMBLIES. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-25 |
Time |
11:30 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2005-02-25 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-21 |
Time |
08:06 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2005-01-21 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04121040 | | | ADD: 533 CLEMATIS STREET | | | CONT: SHAKMAN CONSTRUCTION | | | TEL: (561)705-8288 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) SHEET A2.0 FIRE RATING NOTE | | | INDICATES | | | THAT THE COLUMNS WILL BE FIRE PROTECTED | | | WITH SPRAY APPLIED FIRE RESISTANT | | | MATERIALS ONTO THE STEEL COLUMN. PLANS | | | INDICATE USING U.L. X827 FOR THE FIRE | | | RATING BUT THE SIZE OF THE COLUMN IS NOT | | | | | | STATED NOR THE MINIMUM THICKNESS OF | | | INSULATION OR TYPE OF SPRAY INSULATION. | | | | | | 3) SHEET M6.1 CONDENSING UNIT DETAILS: | | | A) CORRECT CODE AND REFENCE NUMBER, | | | 2001 FL BLDG CODE, 1511.7. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-08 |
Time |
18:51 |
Sent To |
PC |
|
| Notes |
| 2009-10-08 18:51:58 | ** REDLINED PLANS ** | | | | | | 1) NOTE: RISER IS BACK TO INDICATING AN EQUIPMENT | | | GROUNDING CONDUCTOR FROM THE GUTTER TO THE FIRST MEANS | | | OF DISCONNECT WHICH IS PARALLELING THE NEUTRAL. | | | 250.6, 250.24 | | | | | | 2) NOTE: RISER INDICATES THE PANELS K1 AND K2 AS BOTH | | | BEING 250MLO, YET THE PANEL SCHEDULES FOR EACH OF THESE | | | SAME TWO PANELS ARE SHOWN AS 225AMP. | | | | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-24 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-24 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2009-09-24 08:09:18 | ** DENIED ** | | | | | | | | | | | | 1) NOTE: PLEASE SUBMIT A REVISED RISER DIAGRAM TO | | | COORDINATE WITH REVISED PANELS. | | | PLEASE COORDINATE PANELS. AS REDLINED ON PREVIOUS PLANS | | | PANEL K1 WAS NOT A 42 CIRCUIT PANEL IN FIELD HOWEVER | | | PLANS ARE STILL THE SAME. HAS THE PANEL NOW CHANGED IN | | | THE FIELD? | | | IF THIS PANEL IS IN FACT A 30 CIRCUIT PANEL THEN ALL | | | THE CIRCUITING ABOVE 30 ON THE SCHEDULE WOULD NOT BE | | | CORRECT. | | | | | | 2) NOTE: PLEASE SUBMIT THE REVISED RISER DIAGRAM SHEET. | | | 215.5,230, ETC | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2009-04-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-30 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-30 |
Time |
14:02 |
Sent To |
PC |
|
| Notes |
| 2009-04-30 14:03:23 | VIF SOME CHANGES WHICH WERE NOT AS INSTALLED ON SITE AT | | | LAST INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2009-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-12 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-12 |
Time |
10:38 |
Sent To |
PC |
|
| Notes |
| 2009-04-12 10:41:03 | ** PLANS WERE REDLINED TO EXCLUDE THE SERVICE AND | | | PANELS. PLANS ARE FOR ROUGH CEILING AND WALLS ONLY. | | | MET ON SITE WITH JAKE LEAHY, GC, EC AND DESIGNER. PLANS | | | NEED TO BE REVISED SUBSTANTIALLY FOR SERVICE, PANELS, | | | FEEDERS AND OCP DEVICES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-07 |
Time |
21:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-07 |
Time |
21:19 |
Sent To |
|
|
| Notes |
| 2009-04-07 21:19:57 | ** DENIED REVIEW ** | | | | | | ** REDLINED PLANS. | | | | | | 1) NOTE: RISER SHOWS A 150AMP BREAKER FEEDING PANEL | | | K-1. THE RISER CONTAINS A NOTE WHICH STATES THE PANEL | | | K-2 IS FED FROM KI BY A 250AMP BREAKER. EVEN IF THIS | | | BREAKER IS PART OF A FEED-THRU BREAKER SCENARIO, THE | | | FEEDERS FROM PANEL K ARE STILL ONLY RATED FOR 150AMPS | | | AS THEY ARE 1/0 CONDUCTORS. WHY WOULD THERE BE 250MCM | | | FROM PANEL K-1 TO K-2 WHEN THE CONDUCTORS FROM PANEL K | | | ARE ONLY RATED FOR 150AMPS. THE LOAD ON PANEL K2 ALONE | | | EXCEEDS THE RATING OF THE 150AMP FEEDERS. | | | 310.16, 240.4. | | | 220 | | | | | | ** CALLED AND LEFT MESSAGE AT ELECTRICAL DESIGNER'S | | | OFFICE AND CONTRACTOR PHONE NUMBER. PLANS MAY BE | | | REDLINED FOR INSPECTIONS OF ELECTRICAL DEVICES ONLY | | | INCLUDING LIGHTING HOWEVER IT WOULD NOT INCLUDE | | | ELECTRICAL SERVICE EQUIPMENT UNTIL CORRECTIONS ARE | | | MADE. | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2009-03-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-03-27 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-03-27 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2009-03-27 16:50:56 | ** DENIED REVIEW ** | | | | | | REVISION | | | | | | | | | | | | 1) NOTE: PLEASE COORDINATE CALCULATIONS, PLANS, LIGHT | | | FIXTURES AND FIXTURE LEGEND. COMPLIANCE CAN NOT BE | | | VERIFIED AS THE 2X4 LAY IN FIXTURES FOR EXAMPLE ARE NOT | | | SPECIFIC ON PLANS. THE SYMBOL LEGEND INDICATES ONLY ONE | | | FIXTURE FOR THIS SYMBOL YET THE FIXTURE LEGEND | | | INDICATES TWO SEPARATE FIXTURES. ONE FIXTURE CONSUMES | | | TWICE THE WATTAGE OF THE OTHER. | | | 13-415.2 | | | ** IT IS IMPORTANT TO KNOW THAT CEILING FANS ARE NOT | | | PERMITTED TO CONTAIN LIGHT FIXTURES OR KITS UNLESS PART | | | OF THE CALCULATIONS. | | | | | | 2) NOTE: THE DEVICE LEVELS FOR HORNS, STROBES ARE NOT | | | ON SYMBOL LEGEND. THESE MUST MEET FBC 11-4.28.1, .2 AND | | | .3. | | | FS 633 REQUIRES THE BASE PLANS TO MEET REQUIRED DESIGN | | | INTENT FOR ALL BUILDING CODE REQUIREMENTS INCLUDING | | | NFPA-72. | | | THE HEIGHTS WHICH WERE ADDED IS NOT THE ONLY THING | | | REQUIRED. | | | | | | 3) NOTE: PLEASE COORDINATE RISER AND ELECTRICAL PANELS. | | | THE RISER SHOWS THE K2 PANEL BEING FED FROM K PANEL | | | HOWEVER K PANEL SCHEDULE ONLY INDICATES ONE PANEL BEING | | | FED WHICH IS THE K1 PANEL. | | | K PANEL CAN NOT BE A FEED-THRU PANEL AS K IS 400AMP | | | RATED AND K2 IS ONLY 250AMP RATED AND K IS FED BY | | | 400AMP OVER CURRENT PROTECTION. | | | 240.4, 310.16, 230.76, 110.3, ETC. | | | | | | 4) NOTE: PLEASE SEE 310.16 AS THE RISER SHOWS 350MCM | | | FEEDERS FROM THE 400AMP MCB DISCONNECT TO THE PANEL K. | | | HOWEVER BASED ON 310.16, 110.14, THE 350MCM ARE ONLY | | | RATED FOR 310AMPS. | | | | | | 5) NOTE: PLEASE SEE PREVIOUS NOTES THE NFPA-101 IN | | | EFFECT AT THE TIME OF PERMIT APPLICATION IS THE 2000. | | | PLANS STATE 2003 WHICH DID HAVE CHANGES TO EGRESS PATHS | | | IN DESIGN. | | | | | | 6) NOTE: A FORM 400C-04 WAS SUBMITTED AS PART OF THE | | | PACKAGE FOR PRESCRIPTIVE REQUIREMENTS. | | | THE FIRST ITEM WOULD BE THE FACT THE FORM WAS NOT | | | SIGNED, DATED OR SEALED BY THE ARCHITECT LISTED. | | | SECOND: THE FORM IS FROM THE 2004 FBC. PLANS ARE STATED | | | TO BE UNDER THE 2001 | | | THIRD: THE FORM IS NOT COMPLETE. | | | FORTH: THE FORM IS METHOD *C*, WHERE PLANS FOR LIGHTING | | | ANYWAY MENTIONS SPACE BY SPACE WHICH IS *B*. PLEASE SEE | | | THE CODE AS IT DOES NOT PERMIT THE USE OF TWO DIFFERENT | | | METHODS FOR THE SAME SPACE/PERMIT. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-01-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-16 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-16 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2009-01-16 10:50:23 | ** DENIED PLANS** | | | | | | | | | ** PLANS SUBMITTED DO CONTAIN REVISIONS AND NOT ALL ARE | | | A RE-STAMP. | | | | | | | | | 1) NOTE: PROJECT IS UNDER THE 2001 FBC. PLEASE ADJUST | | | CODES FOR OTHER AS WELL. | | | DESIGN MAY STILL BE UNDER 2004 AS SHOWN, HOWEVER AS | | | LONG AS THE DESIGN MEETS THE 2001 THIS IS THE CODE | | | WHICH NEEDS TO BE PLACED ON THE PLANS. | | | | | | 2) NOTE: PLEASE COORDINATE ALL ITEMS ON THE PANELS WITH | | | THE RISER DIAGRAM. THERE ARE SEVERAL ITEMS WHICH HAVE | | | BEEN COMPLETELY REVISED FROM ORIGINAL PLANS AS WELL AS | | | SEVERAL ITEMS WHICH DO NOT CORRELATE. | | | RISER SHOWS 600AMP MAIN TO 600AMP MAIN PANEL. | | | THIS PANEL IS NOTED AS PANEL *A* ON RISER YET PANEL *K* | | | ON PANEL SCHEDULE. | | | THIS PANEL IS ALSO 400AMP MLO ON SCHEDULE. | | | PANEL *K* SCHEDULE DOES NOT INDICATE THE | | | BREAKERS/CIRCUIT FEEDING BOTH PANELS AS SHOWN ON RISER. | | | IN FACT THE RISER SHOWS ONE PANEL AS PANEL *C* WHICH IS | | | 125AMPS AND PANEL *B* IS SHOWN AS 225AMP MLO. | | | THERE IS IN FACT NO PANEL *C* OR *B* SCHEDULE EVEN | | | SUBMITTED. THERE IS HOWEVER A NEW *K1*. | | | | | | ** THESE ITEMS AS NOTED ABOVE ARE A FEW EXAMPLES OF | | | ITEMS WHICH DO NOT COORDINATE. PLEASE REVISE AND SHOW | | | COMPLIANCE FOR ALL FEEDERS, OVER CURRENT PROTECTION, | | | REVISED SCHEDULES, REVISED PANELS ETC. | | | 240.4,310.16,408.4,250,230,225,215, | | | | | | 3) NOTE: PLEASE INCLUDE ALL HORN/STROBE LEVELS PER | | | 11-4.28.1,.2 AND .3. | | | | | | 4) NOTE: PLEASE SEE 700.12E FOR CIRCUITING OF EMERGENCY | | | AND EXIT LIGHTS. THERE ARE SOME ON PLANS MISSING | | | CIRCUITING. | | | | | | 5) NOTE: PLEASE SEE THE EGRESS PATHS ALONG THE BOOTHS | | | DO NOT SHOW ANY EMERGENCY BACK UP LIGHTS. WHEN THIS | | | PROJECT WAS ORIGINALLY PERMITTED THE REVIEW OF EGRESS | | | LIGHTING WAS NOT UNDER THE ELECTRICAL REVIEW. THIS IS | | | NOT PART OF THE ELECTRICAL REVIEW SO PLEASE REVISE TO | | | MEET THE LIFE SAFETY CODE IN EFFECT AT THE TIME OF | | | PERMIT APPLICATION. | | | PLEASE SEE NFPA-101 2000, 7.8 AND 7.9. | | | ** NOTED FOR INFORMATION: THE LIGHTING LEVELS FOR ALL | | | EGRESS WALKING SURFACES WHICH ARE FLAT ARE THE SAME AS | | | THE CURRENT CODES. ONLY STAIRS CHANGED IN THE 2003 LIFE | | | SAFETY CODE. | | | | | | 6) NOTE: PLEASE PROVIDE OR REVISE THE SYMBOL LEGEND AS | | | SUBMITTED. THERE ARE ITEMS ON PLANS WHICH CAN NOT BE | | | DETERMINED AT THIS TIME. SEE DEVICE WHICH SEEMS TO BE | | | HALF OF A HORN/STROBE WHICH IS SHOWN CIRCUITED TO A | | | LIGHT FIXTURE. WHAT IS THIS? | | | THERE ALSO SEEMS TO BE HORN/STROBES IN OTHER LOCATION | | | CONNECTED TO EMERGENCY AND EXIT LIGHTS. THIS IS NO | | | POSSIBLE. SEE NEC 760 FOR WIRING AND OTHER ADOPTED | | | CODES SUCH AS NFPA-13 FOR REQUIRED SYSTEMS. | | | NEC 1999 | | | FBC 104.1.2 | | | | | | 7) NOTE: PLEASE BE SURE TO IDENTIFY ALL FIXTURES ON | | | PLANS AND COORDINATE WITH THE FIXTURE LEGEND. | | | COMPLIANCE WITH FBC 13-415.2 WILL BE VERIFIED ONCE | | | THESE ARE DESIGNATED. | | | PLEASE ALSO COORDINATE DESIGNATIONS. FOR EXAMPLE: | | | EXTERIOR FIXTURES WHICH ARE NOTED AS *D* AS IDENTIFIED | | | AS FLOOR LAMPS ON THE FIXTURE LEGEND. | | | | | | 8) NOTE: PLEASE SEE 13-415.1.ABCD.1.1.5 FOR CONTROLS OF | | | EXTERIOR LIGHTING. | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-23 |
Time |
08:53 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-02-23 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | REDLINED NOTES: | | | | | | | | | EQUIPMENT GROUNDING CONDUCTOR STILL | | | SHOWN FROM GUTTER TO METER AND METER TO | | | FIRST MEANS OF DISCONNECT. | | | THIS SHALL NOT BE INSTALLED. | | | 250.6,250.24 | | | | | | BAR AREA RECEPTS TO BE GFI 210.8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-29 |
Time |
15:57 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-12-29 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2004-12-29 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE RISER INDICATES | | | EQUIPMENT GROUNDING CONDUCTORS FROM | | | GUTTER TO METER AND THEN TO THE FIRST | | | MEANS OF DISC? | | | PLEASE SEE 250.6,250.24, AN EQUIPMENT | | | GRND IS ONLY INSTALLED AFTER THE FIRST | | | MEANS OF DISC. | | | EXIST SERVICE EQUIPMENT IS SHOWN AS | | | HAVING THIS EG ALSO? PLEASE VERIFY. IF | | | THIS INSATLLED, THEN IT WILL BE REQUIRED | | | TO BE REMOVED WHEN SERVICE | | | WORK/CONNECTION IS DONE. | | | | | | 2)NOTE: PLEASE VERIFY LOAD SHOWN FOR NEW | | | SERVICE. PLEASE VERIFY 88.86 KVA = | | | 213A'S. | | | 215/220 | | | | | | 3)NOTE: PLEASE SEE CONDUCTORS FROM MAIN | | | DISC ARE 3/0'S WHICH ARE RATED FOR | | | 200A'S PER 310.16, YET MAIN DISC IS | | | SHOWING 300A FUSES? LOAD ON MAIN ALSO | | | EXCEEDS CONDUCTOR RATING. | | | PLEASE VERIFY. 310.16,240.4B | | | | | | 4)NOTE: PLEASE SEE 424.3B FOR "MIN" OCP | | | FOR AHU'S.THE AMPACITY OF THE | | | BRANCH-CIRCUIT CONDUCTORS AND THE RATING | | | OR SETTING OF OVERCURRENT PROTECTIVE | | | DEVICES SUPPLYING FIXED ELECTRIC | | | SPACE-HEATING EQUIPMENT CONSISTING OF | | | RESISTANCE ELEMENTS WITH OR WITHOUT A | | | MOTOR SHALL NOT BE LESS THAN 125 PERCENT | | | OF THE TOTAL LOAD OF THE MOTORS AND THE | | | HEATERS. | | | | | | 5)NOTE: PLEASE SEE 2002 NEC 210.8B3 | | | WHICH REQUIRES ALL RECEPTS IN KITCHEN TO | | | BE GFI/GFI PROTECTED. THIS IS NOT ONLY | | | FOR COUNTERSPACE OUTLETS. THIS WOULD | | | INCLUDE FRIG'S ETC. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-05-27 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-05-27 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2009-05-27 10:59:54 | *****REVISION, DATED 5/15/2009, APPROVED***** | | | | | | | | | REVISED PLAN SHEET 1.5A STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2009-03-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-03-25 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-03-25 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2009-03-25 13:23:45 | *****APPROVED***** | | | | | | | | | PLAN SHEETS 1.0A, 1.4A, 1.5A, 2.0E, AND 2.1E WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2009-02-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-02-03 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-02-03 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2009-02-03 14:59:58 | ***DENIED*** | | | | | | 1) PLEASE SEE MECHANICAL REVIEW COMMENT #3 REGARDING | | | HOOD/SUPPRESSION SYSTEMS. IN ADDITION, SEPARATE SHOP | | | DRAWINGS AND PERMITS REQUIRED PRIOR TO EQUIPMENT | | | INSTALLATION. | | | | | | 2) DUCT SMOKE DETECTORS SHALL INITIATE A GENERAL FIRE | | | ALARM IN ACCORDANCE WITH LOCAL REQUIREMENTS. | | | | | | 3) OCCUPANT LOAD SIGN IS REQUIRED PRIOR TO FINAL | | | INSPECTION. CONTACT BUREAU OF FIRE PREVENTION AT (561) | | | 804-4724 FOR ASSISTANCE. | | | | | | 4) PLEASE ADD NOTE FROM FIRST FIRE PLAN REVIEW ON DOOR | | | SCHEDULE REGARDING PANIC HARDWARE. | | | | | | | | | MIKE WENNERGREN, ASST. FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-22 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-22 |
Time |
17:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-21 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-21 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | 1. PLEASE PROVIDE DIMENSIONS FOR THE | | | LOOS CHAIRS LOCATED AT THE TABLES. | | | SOME OF THE LOOSE CHAIRS APPEAR TO | | | BE LOCATED TOO CLOSE TOGETHER. | | | | | | 2. ALL WALK-IN COOLERS AND FREEZERS | | | ARE TO BE FIRE SPRINKLER PROTECTED. | | | | | | 3. DEMOLITION, RENOVATION AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 4. PANIC HARDWARE REQUIRED ON ALL | | | EXIT DOORS SUBJECT TO AN OCCUPANCY | | | OF 100 OR MORE PERSONS. | | | | | | 5. HOOD EXHAUST DUCT TERMINATION | | | POINT APPEARS TO BE DIRECTLY | | | ADJACENT TO THE REAR EXIT DOOR. | | | | | | 6. PLEASE PROVIDE PRODUCT APPROVALS | | | FOR THE HOOD EXHAUST DUCT WRAP. | | | | | | 7. SEPARATE PLANS AND PERMITS | | | REQUIRED FOR ANY FIRE SPRINKLER | | | REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2009-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-15 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-15 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2009-10-15 18:00:36 | REVISION SHEET 3.2A OK -- NEW GAS APPLIANCES IN KITCHEN | | | AREA -- DELETED OTHER APPLIANCES. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-21 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-21 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2009-09-21 08:06:13 | REVISION OK -- SHT 3.2A(P) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-08 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-08 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2009-10-08 16:51:09 | *****************EXPEDITED*************** | | | GAVE TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-09-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-09-15 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-09-15 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2009-09-16 08:02:09 | REVIEW COMPLETE, PASSED TO KSTEVENS | | 2009-09-15 17:51:10 | *****************EXPEDITED********************* | | | GAVE TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-19 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2009-05-19 13:20:17 | SENT TO BOB BOX #B10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-21 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-21 |
Time |
17:01 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-26 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2009-02-26 16:38:43 | TO "COMM" BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-30 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-30 |
Time |
16:22 |
Sent To |
B |
|
| Notes |
| 2009-01-05 10:25:56 | 1/5/09--TO "COMM" BD#32---BROUGHT IN AS A RESTAMP, BUT | | | PER "JWITMER" IS ACTUALLY A REV. FEE'S ARE TO BE ADDED | | | ON ACCORDINGLY. | | 2008-12-30 16:23:28 | TO "JWITMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-29 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-29 |
Time |
14:38 |
Sent To |
P |
|
| Notes |
| 2005-03-29 00:00:00 | TO "KSTEVENS" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-08 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-08 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2005-02-08 00:00:00 | TO "COMM" BD #42/RESUBMISSION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-21 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2004-12-20 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | SENT TO "COMM BD#47 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-08 |
Time |
20:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-08 |
Time |
20:37 |
Sent To |
P |
|
| Notes |
| 2009-10-08 20:38:03 | REVISED 3.1M "AS-BUILTS" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-09-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-16 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-16 |
Time |
07:38 |
Sent To |
P |
|
| Notes |
| 2009-09-16 08:00:58 | PAGE 3.1M REVISION #2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-30 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-30 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2009-04-02 15:17:36 | PAGE 3.1M PROVIDED BY NEW DESIGNER OF RECORD. THIS PAGE | | | REPLACES ALL PREVIOUS MECHANICAL PAGES FROM PREVIOUS | | | DESIGNER OF RECORD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2009-02-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-02-01 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-02-01 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2009-02-01 14:20:32 | REVIEW #: REVISION - CHANGE OF DESIGNER | | | ACTION: DENIED | | | | | | FBC 2001 CODE FAMILY | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. GENERAL NOTES INDICATE THIS PROJECT IS UNDER THE | | | 2004 FBC. THIS PROJECT IS PERMITTED UNDER THE 2001 FBC. | | | PLEASE ADJUST ALL PLAN NOTES AND DESIGN REQUIREMENTS | | | ACCORDINGLY. | | | | | | 2. THESE PLANS WERE SUBMITTED AS A RESTAMP. HOWEVER, IN | | | CONJUNCTION WITH THE CHANGES IN DESIGN PROFESSIONALS, | | | THE HVAC SYSTEMS HAVE BEEN COMPLETELY REDESIGNED. THAT | | | MEANS THESE PLANS CONSTITUTE A REVISION. PLEASE PAY ALL | | | APPLICABLE FEES FOR A REVISION BASED ON THE CITY'S | | | CURRENT FEE SCHEDULE. | | | | | | 3. THE RE-CREATED PLANS BY METRO ARCHITECTURE HAVE | | | OMITTED THE COMMERCIAL KITCHEN EXHAUST SYSTEM. | | | COMMERCIAL KITCHEN GREASE HOOD, GREASE EXHAUST DUCT AND | | | ASSOCIATED VENTILATION SYSTEMS SHALL BE PROVIDED IN | | | ACCORDANCE WITH FBCM 506 AND 507. | | | | | | 4. SHOW HEIGHT OF ROOF STANDS TO BE IN COMPLIANCE WITH | | | FBCB TABLE 1511.7. | | | | | | 5. NOTE ON PAGE 3.1A CALLS FOR DUCTS PENETRATING | | | FLOOR/CEILING ASSEMBLY TO BE PROTECTED WITH "EXPANDING | | | COLLARS." DUCTS CONNECTING MORE THAN 2 FLOORS SHALL BE | | | ENCLOSED IN SHAFT CONSTRUCTION IN ACCORDANCE WITH FBCM | | | 607 AND FBCB CHAPTER 7. DUCT PENETRATIONS OF SHAFT | | | ENCLOSURES SHALL BE PROTECTED IN ACCORDANCE WITH FBCM | | | SECTION 607. | | | | | | 6. NOTE ON 3.1A CALLS FOR SMOKE DETECTORS ON EACH AHU. | | | THERE IS NO SMOKE DETECTOR SHOWN ON AHU 2 ON FLOOR | | | PLAN. PLEASE CORRECT IN ACCORDANCE WITH FBCM 606. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2005-03-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | PASS PRIVISO | | | 1) HOOD EXHAUST MUST TERMINATE 40 | | | IN.ABOVE ROOF NFPA 96 FIGURE A.4.2(D) | | | 2) SUPPLY HANGING DETAL FOR HOOD BEFOR | | | ROUGH INSPECTION | | | 3) YOU NEED HORN & STROBE FOR FAN | | | SHUTDOWN NOT A KEY SWITCH.THE MINIMUM | | | SOUND PRESSURE SHALL BE 60DBA MAXIMUM | | | SOUND PRESSURE SHALL BE 130DBA.STROBE | | | MUST BE SEEN FROM ANY PART OF THE | | | RESTAURANT. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-20 |
Time |
06:53 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-01-20 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | DENIED: | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPPRESSION, WALK-IN COOLERS AND | | | FREEZERS.PLEASE PROVIDE | | | MANUFACTURER'S | | | CUT SHEETS & INSTALLATION INSTRUCTIONS | | | FOR THE WALK-IN COOLERS/FREEZERS. | | | | | | HOOD REVIEW: | | | 1. PROVIDE DISTANCE TO PROPERTY LINES, | | | PARKING LOT, SIDE WALK OR ADJACENT | | | BUILDINGS AND FRESH AIR INTAKES IN | | | ACCORDANCE WITH 2001 FBC(M)506.3.14.3. | | | | | | 2. PLAN SHEET M2.1 KEF-1 IS TERMINATING | | | TO THE EXTERIOR WALL.PER 2001 | | | FBC(M)506.3.14.2, OPENINGS SHALL NOT BE | | | LOCATED WITHIN 3 FEET OF THE | | | TERMINATION.PROVIDE INFORMATION ON | | | THE | | | EXTERIOR WALL WHERE EXHAUST TERMINATES. | | | PLEASE NOTE, TERMINATION CAN NOT BE | | | LOCATED WHERE PROTECTED OPENINGS ARE | | | REQUIRED. | | | | | | 3.INDICATE ELEVATION FOR TERMINATION | | | OF THE KEF-1.PLAN SHEET A2.0 SHOWS | | | THE | | | KEF-1 TERMINATING ABOVE THE CAN WASH. | | | PLEASE CLARIFY. | | | | | | 4. PROVIDE INFORMATION ON THE "WRAP" | | | INDICATED FOR THE GREASE DUCT. | | | | | | PLEASE NOTE PLANS FOR THE HOOD MAY BE | | | SUBMITTED WITH THE HOOD PERMIT | | | APPLICATION.NO PLANS SUBMITTED FOR | | | THE | | | FIRE SUPPRESSION.PLEASE PROVIDE PLANS | | | WITH FIRE SUPPRESSION PERMIT | | | APPLICATION. | | | | | | HVAC REVIEW: | | | 1.PLEASE INDICATE HEIGHT OF THE | | | BUILDING.PLAN SHEET A2.0 INDICATES | | | THERE IS MORE THAN 1 STORY.PER 2001 | | | FBC(M)607.4, FIRE DAMPERS ARE REQUIRED | | | ON DUCTS THAT PENETRATE A CEILING FLOOR | | | ASSEMBLY.WHERE DUCTS EXTEND THROUGH | | | MORE THAN ONE FLOOR/CEILING A SHAFT | | | WILL | | | BE REQUIRED. | | | | | | 2.CONDENSING UNIT STANDS LOCATED ON | | | THE ROOF SHALL COMPLY WITH 2001 | | | FBC(M)1511.7 FOR CLEARANCE BETWEEN THE | | | ROOF SURFACE AND THE BOTTOM OF THE | | | SUPPORT RAIL. | | | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION TO ALARM/STROBE IN | | | NORMALLY OCCUPIED AREAS.2001 FBC(M) | | | 606.2.1 & 606.4.1 #2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-04-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-03 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-03 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2009-04-03 09:46:15 | NEW DESIGNER OF RECORD -- REVISIONS FOR ALL SHEETS | | | APPROVED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-30 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-30 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2009-01-30 13:34:31 | DENIED | | | REFERENCE: | | | FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | | | | 1. PLANS WERE SUBMITTED AS A RESTAMP. THERE ARE CHANGES | | | TO THE ORIGINAL PLANS AND THE ORIGINAL SET OF PLANS HAS | | | 5 PLUMBING SHEETS WHEREAS THERE WERE ONLY 3 PLUMBING | | | SHEETS. PLEASE SUBMIT ALL SHEETS. PER THE LETTER THERE | | | IS A NEW ARCHITECT OF RECORD SO ALL SHEETS SHALL BE | | | REPRODUCED BY THE NEW ARCHITECT OF RECORD. FAC | | | 61G1-18.002. | | | | | | 2. SHT 3.0P THE FLOOR SINK FOR THE 3 COMPARTMENT SINK | | | SHOWS NO CONNECTION TO THE BUILDING DRAIN OR BRANCH | | | LINE. SECTION 701.1. PLEASE INDICATE WHERE THE FLOOR | | | SINK CONNECTS TO THE SANITARY DRAINAGE. SECTION | | | 104.2.1. | | | | | | 3. SHT 3.0P THE HOT WATER SUPPLY TO THE LAVS IN THE | | | MEN'S & WOMEN'S TOILET ROOMS SHALL BE INDICATED ON THE | | | LEFT SIDE OF THE FIXTURE. SECTION 607.4. PLANS SHOW HOT | | | ON RIGHT SIDE OF FIXTURE. | | | | | | 4. SHT 3.2A NOTES NUMBER 3 INDICATES THE PLUMBING CODE | | | AS 2004. THE CODE IN EFFECT AT THE TIME THE PERMIT WAS | | | ISSUED WAS 2001. PLEASE CORRECT CODE REFERENCE. SECTION | | | 104.2.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-14 |
Time |
11:03 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2005-04-14 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-21 |
Time |
10:02 |
Rev Time |
1.85 |
| Received By |
kstevens |
Date |
2005-03-09 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2005-03-21 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | | | | 1. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 - | | | SHEETS REQUESTED ON 3-09-5 WERE FAXED | | | OVER ON 3-14-5 - CALLED CONTRACTOR | | | ADVISING NEW APPLIANCES WERE SHOWN AND | | | SHEET WERE REQUIRED FOR THOSE AND THAT A | | | DIFFERENT GAS APPLIANCE LAYOUT WAS FAXED | | | WITH SHEETS. NEW SHEETS DO NOT CORRELATE | | | WITH BTU'S LISTED ON PLANS AND SOME | | | SHEETS SHOW APPLIANCES NOT SHOWN ON THE | | | GAS RISER DIAGRAM. ED BRAHMAN INDICATED | | | ON 3-14-5 HE WILL GET BACK TO ME ON THIS | | | BUT DID NOT. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-20 |
Time |
17:52 |
Rev Time |
1.55 |
| Received By |
kstevens |
Date |
2005-01-20 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1) GREASE INTERCEPTORS SHALL BE SIZED BY | | | RODNEY COMPO, ENVIRONMENTAL COMPLIANCE | | | PER WASTE ORD. #2938-96. (561) 837-4074 | | | 2) SHT A2.0 EQUIPMENT SCHEDULE #3 NOT | | | FOUND ON THE FLOOR PLAN. PLEASE CLARIFY | | | SECTION 104.2.1. | | | 3) SHT A2.0 FIRST FLOOR PLAN. RED LINE | | | MARKINGS FROM THE FDBR HOTEL AND | | | RESTURANT DIV. INDICATES THAT 2 NEW HAND | | | SINKS ARE REQUIRED AND ONE OTHER HAND | | | SINK SHALL BE DELETED. PLEASE REVISE | | | SHT | | | A2.0 SHOWING THESE REQUIREMENTS. | | | RESUBMIT STAMPED SHEET A2.0 WITH NEW | | | SHT | | | A2.0 AND INDICATE ON SHEET FOR DBPR | | | STAMP ONLY. | | | 4) RPZ BACKFLOW IS REQUIRED ON THE WATER | | | SERVICE. SECTION 608.13.2. | | | 5) SHTS P2.1, P5.1, & P5.2 DO NOT SHOW | | | NEW HAND SINKS REQUIRED BY DBPR, NOR DO | | | THEY SHOW THE HAND SINK DELETED BY DBPR. | | | PLEASE REVISE AS REQUIRED. SECTION | | | 104.2.1. | | | 6) SHT P5.1 GAS RISER DIAGRAM. THE | | | FOLLOWING INFORMATION IS REQUIRED FOR | | | THE REQUIRED GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | D. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | 7) SHT P6.2 WATER FILTER FOR ICE MAKER | | | SHALL COMPLY WITH NSF-42. PLEASE SUBMIT | | | MANUF. SPECIFICATION SHEET SHOWING | | | COMPLIANCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2009-03-12 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2009-03-12 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2009-03-12 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2009-03-12 08:45:44 | ZONING REVIEW: NOT REQUIRED | | | | | | ** INTERIOR RENOVATIONS ONLY | | | | | | NOTE: THIS PROPERTY IS LOCATED IN A HISTORIC DISTRICT; | | | ANY FUTURE REVISIONS TO THESE DRAWING WHICH ALTER THE | | | EXTERIOR OF BUILDING WILL REQUIRE ZONING AND HISTORIC | | | REVIEW. | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2009-01-30 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2009-01-30 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2009-01-30 14:24:24 | ZONING REVIEW: NOT REQUIRED | | | | | | ** INTERIOR RENOVATION ONLY | | | | | | MATT FLIS - 822-1445 |
|
|