| Plan Review Stops For Permit 04121023 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-02 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-05-02 |
Time |
08:41 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
2005-05-02 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2005-05-02 00:00:00 | DRAWINGS D1 & D2 WINDOW DETAILS | | | REQUISTED BY INSPECTOR LS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-25 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-02-25 |
Time |
10:27 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-02-25 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-02-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-02-17 |
Time |
10:48 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2005-02-17 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2005-02-17 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. HIGHLIGHT THE STORM PANEL DRAWINGS | | | SHOWING THE METHOD OF ATTACHMENT TO | | | HOUSE. SHOW WHAT TYPE OF ANCHORS & TYPE | | | OF EXTERIOR WALLS. | | | | | | 2. LOCAL PRODUCT APPROVAL HAS BEEN | | | APPROVED FOR THE 650 & 660 DEVAC | | | WINDOWS. REMOVE ALL REFERENCES FOR | | | MODELS NOT BEING INSTALLED IN THIS | | | HOUSE. | | | | | | 3. DO NOT STAPLE PACKAGES. INDIVIDUAL | | | STAPLED PAPERS LIGH PRODUCT APPROVALS | | | ARE OKAY. | | | | | | 4. SEE ELEC. REVIEW NOTES. HAVE ENGINEER | | | RESIGN SHEETS SO ALL ARE ORIGINAL | | | SIGNATURES. | | | | | | ANY QUESTIONS PLEAASE CALL | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-06 |
Time |
07:43 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2005-01-06 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2005-01-06 00:00:00 | BUILDING PLAN REVIEW: FAILED: | | | | | | | | | 1. PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | NEED | | | FLORIDA PRODUCT APPROVALS FOR THE | | | FOLLOWING: | | | DOORS, WINDOWS & STORM PANELS | | | | | | 2.SUBMIT PRODUCT APPROVALS FOR THE | | | WINDOWS. | | | | | | 3. THE WINDOW DRAWINGS BY DONALD W. | | | SHACKELFORD P.E. SHOW WINDOWS 4,5,6,7,8 | | | TO BE SIZED AT 35" X 50" | | | THE WINDOW SCHEDULE HAS THE | | | MEASUREMENTS | | | AS 36" X 50X | | | | | | 3. SEE ELECTRICAL COMMENTS REGARDING | | | SEAL & SIGNATURE REQUIREMENTS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLAN REVIEW | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
14:21 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-02-24 |
Time |
14:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
15:08 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-02-14 |
Time |
15:08 |
Sent To |
B |
|
| Notes |
| 2005-02-14 00:00:00 | ******** UNSAT2ND REVIEW *********** | | | | | | 1)NOTE; PLEASE SEE NOTES #1 AND 2 FROM | | | PREVIOUS REVIEW. | | | PLEASE PROVIDE LICENSE #'S AS REQUIRED | | | PER FAC AND FS. | | | | | | PLEASE SEE STRUCTUAL CALCS WHICH ARE | | | PHOTO -COPIES OF SIGNATURE. | | | SEE BLDG REVIEW NOTES. MUST BE ORIGINAL | | | SIGNATURE. 471.025 | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-28 |
Time |
07:10 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-12-28 |
Time |
07:10 |
Sent To |
M |
|
| Notes |
| 2004-12-28 00:00:00 | **************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004 AND | | | FAC 61G15-23.002 FOR MISSING LICENSE | | | INFORMATION FOR ARCHITECTS AND | | | ENGINEERINGFIRM PER FS 481.219, | | | 471.023. | | | THIS INFORMATION IS REQUIRED FOR ALL | | | TRADES AND FOR ALL SHEETS WHEATHER OR | | | NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | | | | 2)NOTE: PLANS WHICH CONTAIN THE TITLE | | | BLOCK FOR ENGINEER RESPONSIBLE FOR | | | PLANS/DESIGN, MUST SIGN, DATE AND SEAL | | | PLANS. FS 471.025 | | | | | | 3)NOTE: PLEASE SUBMIT ELECTRICAL DRAWING | | | FOR PROPOSED ELECTRICAL WORK TO BE | | | PERFORMED. | | | NO PLANS SUBMITTTED YET, AN ELECTRICLA | | | CONTRACTOR IS SIGNED ON APPLIACTION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-29 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-29 |
Time |
11:26 |
Sent To |
B |
|
| Notes |
| 2005-04-29 00:00:00 | TO "LSMITH" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-18 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-18 |
Time |
14:46 |
Sent To |
E |
|
| Notes |
| 2005-02-18 00:00:00 | TO DPALMER DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-09 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-09 |
Time |
10:16 |
Sent To |
E |
|
| Notes |
| 2005-02-09 00:00:00 | TO DPALMER DESK/RESUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
11:33 |
Sent To |
E |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "E" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-15 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-15 |
Time |
10:30 |
Rev Time |
0.25 |
| Received By |
prafter |
Date |
2005-02-15 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-05 |
Time |
12:45 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-05 |
Time |
12:45 |
Sent To |
B |
|
| Notes |
|
|