| Plan Review Stops For Permit 04121009 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-03-29 |
Time |
09:57 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2005-03-29 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2005-03-29 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. PLANS MUST BE TAKEN TO PBC AND IMPACT | | | FEES PAID. THE PLANS WILL BE STAMPED BY | | | THEM AND A COPY OF THE RECEIPT MUST BE | | | SUBMITTED WITH THE STAMPED PLANS BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 2. THE FLOOR PLAN OF THE HOUSE HAS | | | CHANGED. THE REVISED BALANCE OF MONEY | | | OWED FOR THE PERMIT IS $463.77. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-12-30 |
Time |
11:46 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-12-30 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. SUBMIT THE FLORIDA PRODUCT APPROVALS | | | FOR THE USP & SIMPSON STRUCTURAL | | | COMPONENTS SHOWN ON SHEET A-5 ANCHOR | | | LEGEND & ITEM 1 & 3. | | | | | | 2. BEFORE A PERMIT CAN BE ISSUED THE | | | PLANS MUST BE TAKEN TO PBC AND IMPACT | | | FEES PAID. THE PLANS WILL BE STAMPED & | | | A | | | RECEIPT MUST BE SUBMITTED. | | | | | | 3. BUTT GLASS ASSEMBLY: | | | PROVIDE ENGINEERING FOR BUTT GLASS | | | ASSEMBLIES PER 2001 FBC 2406.2. THE | | | ARCHITECT MUST DO AN ON SITE INSPECTION | | | OF THE BUTT GLASS WHEN INSTALLED & A | | | SIGNED & SEALED LETTER FROM HIM | | | SUBMITTED STATING THE WINDOWS HAVE BEEN | | | INSTALLED PER HIS DRAWING. | | | | | | 4. THE LIVING ROOM WINDOWS (H) ARE | | | STOREFRONT PER PLANS.THE DADE COUNTY | | | PRODUCT APPROVALS FOR THE ARCH SERIES | | | 4500 STOREFRONT ARE NOT IMPACT WINDOWS | | | & | | | WILL REQUIRE STORM PANELS. FLORIDA | | | PRODUCT APPROVALS WILL HAVE TO BE | | | SUBMITTED FOR THE WINDOWS OR SITE | | | SPECIFIC APPLICATION. | | | | | | 5. THE STORM PANELS FOR THE LIVING ROOM | | | STOREFRONT WINDOWS WILL HAVE TO BE | | | ADDED | | | TO THE DRAWING FROM ALUFAB HURRICANE | | | SHUTTERS. | | | | | | 6. THE PGT 2"X STD. WALL ALUMINUM TUBE | | | CLIPPED MULLION (DADE COUNTY | | | #02-0701.11 | | | ARE NOT LISTED ON THE FL261 PRODUCT | | | APPROVAL. WHAT WINDOWS ARE THESE | | | MULLIONS FOR? | | | | | | | | | 7. THE VALUE OF THE HOUSE HAS BEEN | | | UNDERSTATED. $991.97 ADDITIONAL FEES | | | ARE | | | DUE BEFORE A PERMIT CAN BE ISSUED. | | | | | | 8. SEE THE NOTE FROM ZONING REGARDING | | | THE REFRIGERATOR IN THE BILLARD ROOM. | | | | | | 9. WHERE ARE THE THERMA-TRU WINDOWS | | | BEING INSTALLED. ACCORDING TO THE DADE | | | COUNTY PRODUCT APPROVAL THEY ARE NOT | | | IMPACT RATED & WILL REQUIRE STORM | | | PANELS. | | | | | | NOTE: MY REVIEW TIME WOULD BE LESS IF | | | YOU WOULD LABEL THE PRODUCT APPROVALS | | | WITH THE # SHOWN ON THE ARCHITECT SHEET | | | A2 IN THE WINDOW & DOOR SCHEDULE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-08 |
Time |
11:34 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-08 |
Time |
11:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-01 |
Time |
16:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-01 |
Time |
16:48 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-14 |
Time |
17:35 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-10-14 |
Time |
17:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-03-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-16 |
Time |
10:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-16 |
Time |
10:27 |
Sent To |
Z |
|
| Notes |
| 2005-03-16 00:00:00 | COMPLETE CHANGE IN PLAN SENT BACK TO | | | ZOING FOR NEW SITE PLAN. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-28 |
Time |
06:53 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-28 |
Time |
06:52 |
Sent To |
M |
|
| Notes |
| 2004-12-28 00:00:00 | ******** UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS FROM MAINS TO | | | PANELS. | | | 250.110,250.24, SIZE PER 250.122 | | | | | | 2)NOTE: PLEASE SEE A SECOND WATER | | | HEATER | | | IS MENTIONED ON PANEL SCHEDULE FOR | | | MASTER BEDRM, YET THIS SECOND UNIT | | | COULD | | | NOT BE LOCATED ON PLANS.? | | | | | | 3)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY | | | NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | 215.5 | | | | | | 4)NOTE: PLEASE SEE 250.66 FOR SIZING OF | | | GROUNDING ELECTRODE CONDUCTOR. (#2 MIN) | | | | | | PLEASE VERIFY OCP FOR OVEN. 50A FOR 6.5 | | | KW? THIS IS ONLY A NOTE: | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2005-12-01 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-12 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-12 |
Time |
10:33 |
Sent To |
E |
|
| Notes |
| 2005-10-12 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-20 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-20 |
Time |
13:33 |
Sent To |
B |
|
| Notes |
| 2005-04-20 00:00:00 | TO "LSMITH" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-05 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-05 |
Time |
08:54 |
Sent To |
P |
|
| Notes |
| 2005-04-05 00:00:00 | TO "KSTEVENS" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-22 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-22 |
Time |
08:25 |
Sent To |
M |
|
| Notes |
| 2005-03-22 00:00:00 | TO "PKRAUSS" BOX/RESUB-NEW PLANS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-21 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-14 |
Time |
14:15 |
Sent To |
E |
|
| Notes |
| 2005-03-14 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-27 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-27 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2004-12-27 00:00:00 | TO "SFR RACK" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
08:30 |
Sent To |
Z |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-23 |
Time |
18:06 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-03 |
Time |
09:46 |
Rev Time |
0.45 |
| Received By |
prafter |
Date |
2005-01-03 |
Time |
09:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-01 |
Time |
16:57 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2005-04-19 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-03-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-26 |
Time |
07:09 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-03-26 |
Time |
07:09 |
Sent To |
B |
|
| Notes |
| 2005-03-26 00:00:00 | DENIED; | | | 1.SIZE ALL PIPE. | | | 2.L.T TO DISCHARGE ABOVE W/M. | | | 3.FLOOR PLAN SHOWS ONE KITCHE SINK RISER | | | DIAGRAM SHOWS TWO SINKS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-01-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-01-06 |
Time |
09:52 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-01-06 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-03-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-03-21 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-03-21 |
Time |
10:16 |
Sent To |
I |
|
| Notes |
| 2005-03-21 00:00:00 | APPROVING SURVEY. SITE PLAN & SURVEY | | | DOES NOT SHOW THE SAME SETBACKS, BUT IS | | | BEING BUILT ACCORDING TO THE APPROVED | | | SETBACKS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-12-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-27 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-27 |
Time |
13:04 |
Sent To |
I |
|
| Notes |
| 2004-12-27 00:00:00 | PROVISO: MUST PROVIDE NEW FLOOR PLANS | | | SHOWING/INDICATING THE REF. AN UNDER THE | | | COUNTER REF.THIS MUST BE SUBMITTED | | | BEFORE PERMIT IS ISSUED. | | | MUST PULL SEPERATE PERMIT FOR | | | POOL/DECK/SCREEN ENCLOSURE. | | | CALLED NAT HEALY |
|
|