Plan Review Details - Permit 04120966
Plan Review Stops For Permit 04120966
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-08-04 Cont ID  
Sent By jwitmer Date 2005-08-04 Time 10:02 Rev Time 0.33
Received By jwitmer Date 2005-08-04 Time 10:02 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-02-28 Cont ID  
Sent By jwitmer Date 2005-02-28 Time 15:04 Rev Time 1.11
Received By jwitmer Date 2005-02-28 Time 15:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-03 Cont ID  
Sent By jwitmer Date 2005-02-03 Time 11:16 Rev Time 0.77
Received By jwitmer Date 2005-02-03 Time 10:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-14 Cont ID  
Sent By jwitmer Date 2005-01-14 Time 11:18 Rev Time 1.11
Received By jwitmer Date 2005-01-14 Time 11:18 Sent To  
Notes
2005-01-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120966
 ADD: 5705 S DIXIE BAY F&G
 CONT: SUNDOWN
 TEL: (561)743-4420
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) CONTACT JOHN HIGGINS @ (561)822-1239
 TO CORRECT ADDRESS. CITY INDICATES 5705
 S DIXIE NOT 5707.
 1A) USPS POSTAL STANDARD DOESN'T ALLOW
 BAYS TO BE IDENTIFIED BY A ALPHABETICAL
 TERMS BAY- A.
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3)FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 4) 1511.7 ROOF MOUNTED MECHANICAL UNIT S
 SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGHT IN ACCORDANCE WITH TABLE 1511.7.
 MECH. 301.13 WIND RESISTANCE MECHANICAL
 EQUIPMENT, APPLIANCES AND SUP PORTS THAT
 ARE EXPOSED TO WIND SHALL BE DESIGNED
 AND INSTALLED TO RESIST THE WIND
 PRESSURES ON THE EQUIPMENT & THE
 SUPPORTS AS DETERMINED IN ACCORDANCE
 WITH THE FL BLD CODE. THIS MAY BE ACCOMP
 LISHED BY DESIGN OR BY APPLICATION OF
 SECTION 301.13.1.
  
 5)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-02-03 Cont ID  
Sent By dpalmer Date 2005-02-03 Time 13:45 Rev Time 0.25
Received By dpalmer Date 2005-02-03 Time 13:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-29 Cont ID  
Sent By dpalmer Date 2004-12-29 Time 07:13 Rev Time 0.33
Received By dpalmer Date 2004-12-29 Time 07:13 Sent To  
Notes
2004-12-29 00:00:00*** UNSAT ***
  
 1)NOTE: PLEASE SEE RISER SHOWS
 MAIN/METER THE SAME AS UNITSC & D.
 PLEASE ADJUST.
  
 2)NOTE: PLEASE SEE NOTE TO SERVICE LOAD
 MENTIONS THIS IS AN ESTIMATED LAOD OF
 20WP/SQ FT. PLEASE SEE THIS IS SHOWN
 FOR
 GEN LT LOADS AND EST FOR LOADS NOT
 KNOWN.
 PLEASE SEE SOME UNIT ARE KNOW AT THIS
 TIME AND INCLUDING ONE AS A REST. FIT
 UP.
 KNOWN LOADS MUST BE FIGURED INTO
 SERVICE
 LOAD CALCULATIONS.220.3B
  
 3)NOTE: PLEASE PROVIDE A NOTE ON RISER
 FOR A "FLOATING NEUTRAL REQUIRED" IN
 TENANT METERS. PLEASE SEE 250.6,
 250.24.
  
 4)NOTE: PLEASE SEE PLANS REFERENCE 5707
 S DIXIE, YET SYSTEM SHOWS 5707? PLEASE
 SEE BLDG REVIEW COMMENTS AND POSSIBLE
 ADDRESS CORRELATION.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE REMOVE ANY OLD/VOIDED SHEETS AND
 INSERT NEW REVISED SHEETS INTO TWO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-02-09 Cont ID  
Sent By mcarsill Date 2005-02-09 Time 16:30 Rev Time 0.00
Received By mcarsill Date 2005-02-09 Time 16:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-01-07 Cont ID  
Sent By mcarsill Date 2005-01-07 Time 13:58 Rev Time 0.00
Received By mcarsill Date 2005-01-07 Time 13:58 Sent To  
Notes
2005-01-07 00:00:001. INTERIOR FINISH CLASSIFICATIONS
 FOR WALLS AND CEILINGS SHALL COMPLY
 WITH APPLICABLE FIRE CODE
 REQUIREMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-15 Cont ID  
Sent By adarroug Date 2005-07-15 Time 10:20 Rev Time 0.00
Received By adarroug Date 2005-07-15 Time 10:20 Sent To B
Notes
2005-07-15 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-24 Cont ID  
Sent By adarroug Date 2005-02-24 Time 16:24 Rev Time 0.00
Received By adarroug Date 2005-02-24 Time 16:24 Sent To  
Notes
2005-02-24 00:00:00TO "COMM" BD#8

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-31 Cont ID  
Sent By mjacobs Date 2005-01-31 Time 10:11 Rev Time 0.00
Received By mjacobs Date 2005-01-31 Time 10:11 Sent To  
Notes
2005-01-31 00:00:00TO "COMM BD#16/RESUB.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-20 Cont ID  
Sent By mjacobs Date 2005-01-19 Time 18:26 Rev Time 0.00
Received By kstevens Date 2004-12-20 Time 07:53 Sent To  
Notes
2004-12-20 00:00:00SENT TO "COMM BD#7

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-02-04 Cont ID  
Sent By pkrauss Date 2005-02-04 Time 16:55 Rev Time 0.40
Received By pkrauss Date 2005-02-04 Time 16:44 Sent To  
Notes
2005-02-04 00:00:00PROVISO;
 AUXILIARY DRAIN LINE SHALL TERMINATE AT
 A CONSPICUOUS POINT (I.E. OVER A SINK),
 TO SERVE AS AN ALARM THAT THE PRIMARY
 DRAIN IS RESTRICTED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By pkrauss Date 2005-01-19 Time 11:20 Rev Time 0.40
Received By pkrauss Date 2005-01-19 Time 11:20 Sent To  
Notes
2005-01-19 00:00:00DENIED:
 1.PLAN SHEET M-1 KEYNOTE #7 O.A.
 LOCATED ABOVE THE CEILING AS SHOWN FOR
 FUTURE USE BY ADJACENT TENANT.PER 2001
 FBC 704.3..1 WHEN ENCLOSED SPACES ARE
 PROVIDED FOR SEPARATE TENANTS, SPACES
 SHALL BE SEPARATED BY A 1 HR FIRE
 RESISTANCE.PLEASE PROVIDE FIRE DAMPERS
 AS REQUIRED PER 2001 FBC(M)607.1.2 AND
 IDENTIFY LOCATIONS ON THE PLANS IN
 ACCORDANCE WITH 2001 FBC(M)607.6.
  
 2.PLAN SHEET M-2 & P-1 INDICATE
 AUXILIARY DRAIN LINE TERMINATING OUTSIDE
 THE BUILDING.PER 2001 FBC(M)307.2.3,
 AUXILIARY DRAIN LINE IS TO TERMINATE AT
 A CONSPICUOUS POINT TO SERVE AS AN ALARM
 THAT THE PRIMARY DRAIN IS RETSTRICTED.
 PLEASE REVISE ACCORDINGLY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-03-05 Cont ID  
Sent By kstevens Date 2005-03-05 Time 15:07 Rev Time 0.60
Received By kstevens Date 2005-03-05 Time 15:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-02-16 Cont ID  
Sent By kstevens Date 2005-02-16 Time 14:00 Rev Time 0.33
Received By kstevens Date 2005-02-16 Time 14:00 Sent To  
Notes
2005-02-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 A) FROM PREVIOUS REVIEW:
 2) SHT A-1 BATHROOM DETAIL. THE
 FOLLOWING INFORMATION IS REQUIRED TO
 SHOW COMPLIANCE WITH SECTIONS 11-4.16,
 11-4.19, & 11-4.22
 B) FLUSH CONTROLS 11-4.16.5
 E) FAUCETS 11-4.19.6
 4) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SE SECTION 410.1 -
 SHOW THE LOCATION OF THE WATER COOLER ON
 THE PLANS. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By kstevens Date 2005-01-19 Time 18:31 Rev Time 0.50
Received By kstevens Date 2005-01-19 Time 18:26 Sent To  
Notes
2005-01-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SEE BUILDING REVIEW CONCERNING THE
 ADDRESS.
 2) SHT A-1 BATHROOM DETAIL. THE
 FOLLOWING INFORMATION IS REQUIRED TO
 SHOW COMPLIANCE WITH SECTIONS 11-4.16,
 11-4.19, AND 11-4.22:
 A) CLEAR FLOOR SPACE 11-4.16.2
 B) FLUSH CONTROLS 11-4.16.5
 C) CLEAR FLOOR SPACE 11-4.19.3
 D) EXPOSED PIPES & SURFACES 11-4.19.4
 E) FAUCETS 11-4.19.6
 F) THE WATER CLOSET SHALL BE 18" FROM
 THE CENTERLINE OF THE FIXTURE TO THE
 WALL. FIG. 28
 G) THE LAV SHALL CENTER ON THE 30"
 MEASURMENT OF THE 30"X48" CLEAR FLOOR
 SPACE AND SHALL BE MIN. OF 15" OFF THE
 WALL TO THE CENTERLINE OF THE FIXTURE.
 3) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE SECTION 410.1.
 4) SHT P-1 WATER ISOMETRIC, AIR CHAMBERS
 SHOWN ON THE LAVS ARE NOT APPROVED.
 DELETE FROM ISOMETRIC. SECTION 604.9.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]