| Plan Review Stops For Permit 04120963 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-29 |
Time |
16:30 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-29 |
Time |
16:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-04 |
Time |
10:04 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-08-04 |
Time |
10:04 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-28 |
Time |
14:02 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-02-28 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-02-03 |
Time |
10:03 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-02-03 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-14 |
Time |
10:46 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2005-01-14 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120963 | | | ADD: 5705 S DIXIE HWY | | | CONT: SUNDOWN DEVELOPMENT | | | TEL: (561)743-4420 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) CONTACT JOHN HIGGINS @ (561)822-1239 | | | TOCORRECT ADDRESS. CITY INDICATES 5705 | | | S | | | DIXIE NOT 5707. | | | 1A) USPS POSTAL STANDARD DOES NOT ALLOW | | | BAYS TO BE IDENTIFIED BY ALPHABETICAL | | | TERMS (BAY-A). | | | | | | 2) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3)FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 4) 1511.7 ROOF MOUNTED MECHANICAL UNIT | | | S | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | MECH. 301.13 WIND RESISTANCE MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUP PORTS | | | THAT | | | ARE EXPOSED TO WIND SHALL BE DESIGNED | | | AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT & THE | | | SUPPORTS AS DETERMINED IN ACCORDANCE | | | WITH THE FL BLD CODE. THIS MAY BE | | | ACCOMP | | | LISHED BY DESIGN OR BY APPLICATION OF | | | SECTION 301.13.1. | | | | | | 5) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO | | | THE | | | AUTHORITY HAVING JURISDICTION. SUCH | | | IDEN | | | TIFICATION SHALL BE ABOVE ANY | | | DECORATIVE | | | CEILING CEILING AND IN CONCEALED | | | SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 6)11-4.16.4 GRAB BARS FORWATER CLOSET | | | SEE FIGURE 29, MISSING THE GRAB BAR | | | BEHIND THE WATER CLOSET. | | | | | | 7)TABLE 803.3 MINIMUM INTERIOR | | | FINISH | | | CLASSIFICATION; PROVIDE INFORMATION | | | BASED ON INTERIOR FINISH REQUIREMENTS | | | BASED ON OCCUPANCY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT | | | NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR | | | SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-09 |
Time |
19:58 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-08-09 |
Time |
19:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-03 |
Time |
14:05 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-02-03 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-29 |
Time |
07:37 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2004-12-29 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2004-12-29 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE RISER SHOWS | | | MAIN/METER THE SAME AS UNITSF & G. | | | PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE SEE NOTE TO SERVICE LOAD | | | MENTIONS THIS IS AN ESTIMATED LAOD OF | | | 20WP/SQ FT. PLEASE SEE THIS IS SHOWN | | | FOR | | | GEN LT LOADS AND EST FOR LOADS NOT | | | KNOWN. | | | PLEASE SEE SOME UNIT ARE KNOW AT THIS | | | TIME AND INCLUDING ONE AS A REST. FIT | | | UP. | | | KNOWN LOADS MUST BE FIGURED INTO | | | SERVICE | | | LOAD CALCULATIONS.220.3B | | | | | | 3)NOTE: PLEASE PROVIDE A NOTE ON RISER | | | FOR A "FLOATING NEUTRAL REQUIRED" IN | | | TENANT METERS. PLEASE SEE 250.6, | | | 250.24. | | | | | | 4)NOTE: PLEASE SEE PLANS REFERENCE 5707 | | | S DIXIE, YET SYSTEM SHOWS 5707? PLEASE | | | SEE BLDG REVIEW COMMENTS AND POSSIBLE | | | ADDRESS CORRELATION. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ANY OLD/VOIDED SHEETS AND | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-29 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-08-29 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | REVISION APPROVED PER M. CARSILLOJW | | | REVISION |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-02-09 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-02-09 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-01-07 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-01-07 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2005-01-07 00:00:00 | 1. INTERIOR FINISH CLASSIFICATIONS | | | FOR WALLS AND CEILINGS TO COMPLY | | | WITH APPLICABLE FIRE CODE | | | REQUIREMENTS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2005-08-08 00:00:00 | TO "COMM" BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-15 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-15 |
Time |
10:21 |
Sent To |
B |
|
| Notes |
| 2005-07-15 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-28 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-28 |
Time |
14:32 |
Sent To |
P |
|
| Notes |
| 2005-02-28 00:00:00 | TO KSTEVENS BOX/TAKEN OFF "COMM" BD#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-24 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-24 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2005-02-24 00:00:00 | TO "COMM" BD#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-31 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-31 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | TO "COMM BD#16/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-19 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2005-02-03 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2004-12-20 00:00:00 | SENT TO "COMM BD#7 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-02-04 |
Time |
16:08 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2005-02-04 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2005-02-04 00:00:00 | PROVISO: | | | AUXILIARY DRAIN LINE SHALL TERMINATE AT | | | A CONSPICUOUS POINT (EXAMPLE; OVER SINK) | | | TO SERVE AS ALARM THAT THE PRIMARY DRAIN | | | IS RESTRICTED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-14 |
Time |
16:42 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2005-01-14 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | PROVISO: | | | 1.PLAN SHEET M-2 CONDENSING UNIT | | | STAND | | | SHALL COMPLY WITH 2001 FBC TABLE 1511.7 | | | FOR PROPER CLEARANCE BETWEEN THE ROOF | | | SURFACE AND THE BOTTOM OF THE SUPPORT | | | RAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-05 |
Time |
13:47 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-03-05 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-16 |
Time |
13:33 |
Rev Time |
0.54 |
| Received By |
kstevens |
Date |
2005-02-16 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2005-02-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | A) FROM PREVIOUS REVIEW: | | | 2) SHT A-1 BATHROOM DETAIL. THE | | | FOLLOWING INFORMATION IS REQUIRED TO | | | SHOW COMPLIANCE WITH SECTIONS 11-4.16, | | | 11-4.19, & 11-4.22 | | | B) FLUSH CONTROLS 11-4.16.5 | | | E) FAUCETS 11-4.19.6 | | | 4) PER TABLE 403.1 A DRINKING FOUNTAIN | | | IS REQUIRED. ALSO SE SECTION 410.1 - | | | SHOW THE LOCATION OF THE WATER COOLER ON | | | THE PLANS. SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-19 |
Time |
17:52 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-01-19 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SEE BUILDING REVIEW CONCERNING THE | | | ADDRESS. | | | 2) SHT A-1 BATHROOM DETAIL. THE | | | FOLLOWING INFORMATION IS REQUIRED TO | | | SHOW COMPLIANCE WITH SECTIONS 11-4.16, | | | 11-4.19, AND 11-4.22: | | | A) CLEAR FLOOR SPACE 11-4.16.2 | | | B) FLUSH CONTROLS 11-4.16.5 | | | C) CLEAR FLOOR SPACE 11-4.19.3 | | | D) EXPOSED PIPES & SURFACES 11-4.19.4 | | | E) FAUCETS 11-4.19.6 | | | F) THE WATER CLOSET SHALL BE 18" FROM | | | THE CENTERLINE OF THE FIXTURE TO THE | | | WALL. FIG. 28 | | | G) THE LAV SHALL CENTER ON THE 30" | | | MEASURMENT OF THE 30"X48" CLEAR FLOOR | | | SPACE AND SHALL BE MIN. OF 15" OFF THE | | | WALL TO THE CENTERLINE OF THE FIXTURE. | | | 3) SUBMIT A SANITARY AND A WATER RISER | | | DIAGRAM. SHOW ALL PIPE SIZES AND SHOW | | | WATER HAMMER ARRESTORS REQUIRED BY | | | SECTION 604.9 LOCATED NEAR THE FIXTURE, | | | NOT IN THE CEILING PER PDI-WH 201. AIR | | | CHAMBERS ARE NOT APPROVED. | | | 4) PER TABLE 403.1 A DRINKING FOUNTAIN | | | IS REQUIRED. ALSO SEE SECTION 410.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|