Plan Review Details - Permit 04120963
Plan Review Stops For Permit 04120963
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-08-29 Cont ID  
Sent By jwitmer Date 2005-08-29 Time 16:30 Rev Time 0.33
Received By jwitmer Date 2005-08-29 Time 16:30 Sent To P
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-08-04 Cont ID  
Sent By jwitmer Date 2005-08-04 Time 10:04 Rev Time 0.33
Received By jwitmer Date 2005-08-04 Time 10:04 Sent To FIRE
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-02-28 Cont ID  
Sent By jwitmer Date 2005-02-28 Time 14:02 Rev Time 1.11
Received By jwitmer Date 2005-02-28 Time 14:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-02-03 Cont ID  
Sent By jwitmer Date 2005-02-03 Time 10:03 Rev Time 0.55
Received By jwitmer Date 2005-02-03 Time 09:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-14 Cont ID  
Sent By jwitmer Date 2005-01-14 Time 10:46 Rev Time 1.11
Received By jwitmer Date 2005-01-14 Time 10:46 Sent To  
Notes
2005-01-14 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04120963
 ADD: 5705 S DIXIE HWY
 CONT: SUNDOWN DEVELOPMENT
 TEL: (561)743-4420
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) CONTACT JOHN HIGGINS @ (561)822-1239
 TOCORRECT ADDRESS. CITY INDICATES 5705
 S
 DIXIE NOT 5707.
 1A) USPS POSTAL STANDARD DOES NOT ALLOW
 BAYS TO BE IDENTIFIED BY ALPHABETICAL
 TERMS (BAY-A).
  
 2) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3)FL BLD CODE CHAP 13 ENERGY EFFICENCY
 PROVIDE ENERGY CALS/ W MANUAL "J"
  
 4) 1511.7 ROOF MOUNTED MECHANICAL UNIT
 S
 SHALL BE MOUNTED ON CURBS RAISED A
 MINIMUM OF 8 INCHES ABOVE THE ROOF SUR-
 FACE, OR WHERE ROOFING MATERIALS EXTEND
 BENEATH THE UNIT, ON RAISED EQUIPMENT
 SUPPORTS PROVIDING A MINIMUM CLEARENCE
 HEIGHT IN ACCORDANCE WITH TABLE 1511.7.
 MECH. 301.13 WIND RESISTANCE MECHANICAL
 EQUIPMENT, APPLIANCES AND SUP PORTS
 THAT
 ARE EXPOSED TO WIND SHALL BE DESIGNED
 AND INSTALLED TO RESIST THE WIND
 PRESSURES ON THE EQUIPMENT & THE
 SUPPORTS AS DETERMINED IN ACCORDANCE
 WITH THE FL BLD CODE. THIS MAY BE
 ACCOMP
 LISHED BY DESIGN OR BY APPLICATION OF
 SECTION 301.13.1.
  
 5) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO
 THE
 AUTHORITY HAVING JURISDICTION. SUCH
 IDEN
 TIFICATION SHALL BE ABOVE ANY
 DECORATIVE
 CEILING CEILING AND IN CONCEALED
 SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 6)11-4.16.4 GRAB BARS FORWATER CLOSET
 SEE FIGURE 29, MISSING THE GRAB BAR
 BEHIND THE WATER CLOSET.
  
 7)TABLE 803.3 MINIMUM INTERIOR
 FINISH
 CLASSIFICATION; PROVIDE INFORMATION
 BASED ON INTERIOR FINISH REQUIREMENTS
 BASED ON OCCUPANCY.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL
 LETTER
 LISTING THE ORIGINAL REVIEW COMMENT
 NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR
 SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-09 Cont ID  
Sent By dpalmer Date 2005-08-09 Time 19:58 Rev Time 0.25
Received By dpalmer Date 2005-08-09 Time 19:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-02-03 Cont ID  
Sent By dpalmer Date 2005-02-03 Time 14:05 Rev Time 0.25
Received By dpalmer Date 2005-02-03 Time 14:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-29 Cont ID  
Sent By dpalmer Date 2004-12-29 Time 07:37 Rev Time 0.30
Received By dpalmer Date 2004-12-29 Time 07:37 Sent To  
Notes
2004-12-29 00:00:00*** UNSAT ***
  
 1)NOTE: PLEASE SEE RISER SHOWS
 MAIN/METER THE SAME AS UNITSF & G.
 PLEASE ADJUST.
  
 2)NOTE: PLEASE SEE NOTE TO SERVICE LOAD
 MENTIONS THIS IS AN ESTIMATED LAOD OF
 20WP/SQ FT. PLEASE SEE THIS IS SHOWN
 FOR
 GEN LT LOADS AND EST FOR LOADS NOT
 KNOWN.
 PLEASE SEE SOME UNIT ARE KNOW AT THIS
 TIME AND INCLUDING ONE AS A REST. FIT
 UP.
 KNOWN LOADS MUST BE FIGURED INTO
 SERVICE
 LOAD CALCULATIONS.220.3B
  
 3)NOTE: PLEASE PROVIDE A NOTE ON RISER
 FOR A "FLOATING NEUTRAL REQUIRED" IN
 TENANT METERS. PLEASE SEE 250.6,
 250.24.
  
 4)NOTE: PLEASE SEE PLANS REFERENCE 5707
 S DIXIE, YET SYSTEM SHOWS 5707? PLEASE
 SEE BLDG REVIEW COMMENTS AND POSSIBLE
 ADDRESS CORRELATION.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE REMOVE ANY OLD/VOIDED SHEETS AND
 INSERT NEW REVISED SHEETS INTO TWO
 COMPLETE SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2005-08-29 Cont ID  
Sent By jwitmer Date 2005-08-29 Time 16:23 Rev Time 0.00
Received By jwitmer Date 2005-08-29 Time 16:23 Sent To  
Notes
2005-08-29 00:00:00REVISION APPROVED PER M. CARSILLOJW
 REVISION

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-02-09 Cont ID  
Sent By mcarsill Date 2005-02-09 Time 16:30 Rev Time 0.00
Received By mcarsill Date 2005-02-09 Time 16:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-01-07 Cont ID  
Sent By mcarsill Date 2005-01-07 Time 13:53 Rev Time 0.00
Received By mcarsill Date 2005-01-07 Time 13:53 Sent To  
Notes
2005-01-07 00:00:001. INTERIOR FINISH CLASSIFICATIONS
 FOR WALLS AND CEILINGS TO COMPLY
 WITH APPLICABLE FIRE CODE
 REQUIREMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-08-08 Cont ID  
Sent By adarroug Date 2005-08-08 Time 15:08 Rev Time 0.00
Received By adarroug Date 2005-08-08 Time 15:08 Sent To  
Notes
2005-08-08 00:00:00TO "COMM" BD#25

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-15 Cont ID  
Sent By adarroug Date 2005-07-15 Time 10:21 Rev Time 0.00
Received By adarroug Date 2005-07-15 Time 10:21 Sent To B
Notes
2005-07-15 00:00:00TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-02-28 Cont ID  
Sent By adarroug Date 2005-02-28 Time 14:32 Rev Time 0.00
Received By adarroug Date 2005-02-28 Time 14:32 Sent To P
Notes
2005-02-28 00:00:00TO KSTEVENS BOX/TAKEN OFF "COMM" BD#8

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-02-24 Cont ID  
Sent By adarroug Date 2005-02-24 Time 15:41 Rev Time 0.00
Received By adarroug Date 2005-02-24 Time 15:29 Sent To  
Notes
2005-02-24 00:00:00TO "COMM" BD#8

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-01-31 Cont ID  
Sent By mjacobs Date 2005-01-31 Time 10:03 Rev Time 0.00
Received By mjacobs Date 2005-01-31 Time 10:03 Sent To  
Notes
2005-01-31 00:00:00TO "COMM BD#16/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-20 Cont ID  
Sent By mjacobs Date 2005-01-19 Time 17:52 Rev Time 0.00
Received By jwitmer Date 2005-02-03 Time 09:18 Sent To  
Notes
2004-12-20 00:00:00SENT TO "COMM BD#7

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-02-04 Cont ID  
Sent By pkrauss Date 2005-02-04 Time 16:08 Rev Time 1.00
Received By pkrauss Date 2005-02-04 Time 13:26 Sent To  
Notes
2005-02-04 00:00:00PROVISO:
 AUXILIARY DRAIN LINE SHALL TERMINATE AT
 A CONSPICUOUS POINT (EXAMPLE; OVER SINK)
 TO SERVE AS ALARM THAT THE PRIMARY DRAIN
 IS RESTRICTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-01-14 Cont ID  
Sent By pkrauss Date 2005-01-14 Time 16:42 Rev Time 0.55
Received By pkrauss Date 2005-01-14 Time 16:30 Sent To  
Notes
2005-01-14 00:00:00PROVISO:
 1.PLAN SHEET M-2 CONDENSING UNIT
 STAND
 SHALL COMPLY WITH 2001 FBC TABLE 1511.7
 FOR PROPER CLEARANCE BETWEEN THE ROOF
 SURFACE AND THE BOTTOM OF THE SUPPORT
 RAIL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-03-05 Cont ID  
Sent By kstevens Date 2005-03-05 Time 13:47 Rev Time 1.00
Received By kstevens Date 2005-03-05 Time 13:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2005-02-16 Cont ID  
Sent By kstevens Date 2005-02-16 Time 13:33 Rev Time 0.54
Received By kstevens Date 2005-02-16 Time 13:33 Sent To  
Notes
2005-02-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 A) FROM PREVIOUS REVIEW:
 2) SHT A-1 BATHROOM DETAIL. THE
 FOLLOWING INFORMATION IS REQUIRED TO
 SHOW COMPLIANCE WITH SECTIONS 11-4.16,
 11-4.19, & 11-4.22
 B) FLUSH CONTROLS 11-4.16.5
 E) FAUCETS 11-4.19.6
 4) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SE SECTION 410.1 -
 SHOW THE LOCATION OF THE WATER COOLER ON
 THE PLANS. SECTION 104.2.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-01-19 Cont ID  
Sent By kstevens Date 2005-01-19 Time 17:52 Rev Time 0.50
Received By kstevens Date 2005-01-19 Time 17:52 Sent To  
Notes
2005-01-19 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) SEE BUILDING REVIEW CONCERNING THE
 ADDRESS.
 2) SHT A-1 BATHROOM DETAIL. THE
 FOLLOWING INFORMATION IS REQUIRED TO
 SHOW COMPLIANCE WITH SECTIONS 11-4.16,
 11-4.19, AND 11-4.22:
 A) CLEAR FLOOR SPACE 11-4.16.2
 B) FLUSH CONTROLS 11-4.16.5
 C) CLEAR FLOOR SPACE 11-4.19.3
 D) EXPOSED PIPES & SURFACES 11-4.19.4
 E) FAUCETS 11-4.19.6
 F) THE WATER CLOSET SHALL BE 18" FROM
 THE CENTERLINE OF THE FIXTURE TO THE
 WALL. FIG. 28
 G) THE LAV SHALL CENTER ON THE 30"
 MEASURMENT OF THE 30"X48" CLEAR FLOOR
 SPACE AND SHALL BE MIN. OF 15" OFF THE
 WALL TO THE CENTERLINE OF THE FIXTURE.
 3) SUBMIT A SANITARY AND A WATER RISER
 DIAGRAM. SHOW ALL PIPE SIZES AND SHOW
 WATER HAMMER ARRESTORS REQUIRED BY
 SECTION 604.9 LOCATED NEAR THE FIXTURE,
 NOT IN THE CEILING PER PDI-WH 201. AIR
 CHAMBERS ARE NOT APPROVED.
 4) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. ALSO SEE SECTION 410.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]