| Plan Review Stops For Permit 04120945 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2008-06-05 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2008-06-05 16:51:48 | SITE WALL REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-08 |
Time |
07:44 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-11-08 |
Time |
07:44 |
Sent To |
B |
|
| Notes |
| 2007-11-08 07:45:17 | RESTAMP PLANS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-07-20 |
Time |
07:59 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-07-20 |
Time |
07:59 |
Sent To |
PC |
|
| Notes |
| 2006-07-20 00:00:00 | REVISION STAIR SHOP DRAWING OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-15 |
Time |
08:04 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-06-15 |
Time |
08:04 |
Sent To |
PC |
|
| Notes |
| 2006-06-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120945 | | | ADD: 2010 PONCE DE LEON AV | | | CONT: TAYCON | | | TEL: (561)262-2113 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: STAIR SHOP DRAWINGS | | | ACTION: DENIED | | | | | | THE TOP SET OF WINDERS FAILED: | | | 1007.8.1 WINDERS SHALL HAVE A MINIMUM | | | TREAD DEPTH OF 6 INCHES (152 MM) | | | AT THE NARROW EDGE AND SHALL HAVE A | | | MINIMUM TREAD DEPTH OF 11 INCHES (279 | | | MM) AT A POINT 12 INCHES (305 MM) FROM | | | THE NARROW EDGE.WINDERS SHALL BE | | | PERMITTED TO BE USED AS A COMPONENT IN | | | THE MEANS OF EGRESS WITHIN A | | | DWELLING UNIT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-07 |
Time |
11:11 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-06-07 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2006-06-07 00:00:00 | ROOF REV UNDERLAYMEENT POLYSTICK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-03 |
Time |
09:11 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-04-03 |
Time |
09:11 |
Sent To |
B |
|
| Notes |
| 2006-04-03 00:00:00 | STRUCTURAL REVISIONS, LOFT CREATEED IN | | | END UNITS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-03 |
Time |
09:09 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-04-03 |
Time |
09:09 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | ROOF SUBMITTALS,FAILED NO ROOFING | | | CONTRACTOR SIGNED ON. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-06 |
Time |
12:26 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2006-02-06 |
Time |
12:03 |
Sent To |
PC |
|
| Notes |
| 2006-02-06 00:00:00 | REV: 2 HR TENANT SEPERATION( CONDO) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-19 |
Time |
07:25 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2005-12-19 |
Time |
07:14 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-10 |
Time |
16:32 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-11-10 |
Time |
16:32 |
Sent To |
PC |
|
| Notes |
| 2005-11-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120945 | | | ADD: 2010 PONCE DE LEON | | | CONT: TAYCON COSTRUCTION | | | TEL: (561)282-7310 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONS: | | | ACTION: DENIED | | | | | | THE REVISION LEGOND IS NOT FILLED OUT ON | | | S-1,S-2, S-3,S-4 & S-5 HAVE DATES BUT DO | | | NOT IDENTIFY WHICH REVISIONS ARE | | | ASSOCIATED WITH THE INDICATED DATES. | | | FL BLD CODE 104.2.1.2* | | | ADDITIONAL INFORMATION REQUIRED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-10 |
Time |
09:47 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2005-11-10 |
Time |
09:47 |
Sent To |
Z |
|
| Notes |
| 2005-11-10 00:00:00 | #4 REVISION TO SITE WALL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-09-27 |
Time |
08:51 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2005-09-22 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-08-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-13 |
Time |
16:54 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2005-08-13 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2005-08-13 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04120945 | | | ADD: 2018 PONCE DE LEON | | | CONT: TAYCON | | | TEL: (561762-0606 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | PRODUCT APPROVALS | | | 1) THE FL COVERSHEET FOR PGT FIXED | | | WINDOWS WAS SUBMITTED BUT NOT THE NOA. | | | | | | 2) THE SAAME HOLDS TRUE WITH THE PGT | | | MULLIONS ONLY THE COVERSHEETWHILE THE | | | REPORT INDICATES VAARIOUS NOA'S ARE | | | COVERED WITHIN THIS REPORT. | | | | | | 3) UNDER THE GARAGE DOOR REPORT | | | HIGHLIGHT OR INDICATE WHICH DOOR OR | | | SERIES YOU ENTENDTO USE? | | | | | | 4) STEEL ROOF PANELS ALSO INDICATE WHICH | | | SYSTEM INSULATED OR NOT? IF USING THE | | | NONINSULATED SYSTEM THE SYSTEM | | | LIMITATION OF A -60 MAXIMUM DESIGN | | | PRESSURE. YOUR ENGINEER CALCULATED AN | | | END ZONE PRESSURE OF -54.1 BUT USING THE | | | TRIBUTARY AREA OF 55 SQ FT. HE NOTES THE | | | END ZONE IS 3'. 3'X3'=9 SQ FT. AGAIN THE | | | | | | TABLES IN 1606.2B INDICATE A -68.1 WHICH | | | WILL REQUIRE ENHANCED FASTENING BY YOUR | | | ENGINEER ONLY FOR ZONE 3. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-01-14 |
Time |
09:34 |
Rev Time |
4.50 |
| Received By |
jwitmer |
Date |
2005-01-14 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2005-01-14 00:00:00 | SEE NOTES PRINTED UNDER PERMIT# 04120942 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-22 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-22 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | ELECTRICAL PLANS STAMPED. | | | | | | | | | ** HIGH-LIGHTED PLANS** | | | | | | | | | NO AFTER DUSK SWIMMING PERMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-09-11 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-09-11 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2005-09-11 00:00:00 | SEE NOTES UNDER 04120942 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-12 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-07-12 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | NOTES UNDER 04120942 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-14 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-06-14 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2005-06-14 00:00:00 | PLEASE SEE NOTES UNDER 04120942 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-29 |
Time |
19:30 |
Rev Time |
2.50 |
| Received By |
dpalmer |
Date |
2004-12-29 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2004-12-29 00:00:00 | *** PLEASE SEE NOTES/REVIEW UNDER PERMIT | | | #04120942 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-12-21 |
Time |
11:06 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2004-12-21 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | PASSED WITH PROVISOS: | | | | | | 1. PLEASE SUBMIT THE CIVIL PLANS ONLY TO | | | THE PUBLIC UTILITIES AND ENGINEERING | | | SERVICES FOR THEIR REVIEW AND APPROVAL | | | OF ALL THE CONNECTION TO THE CITY | | | SERVICES, ATT;MANNY GONZALEZ, 494-1085. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-06-15 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-06-15 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | SEE PLAN REVIEW ON PERMIT 04120942 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-20 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-20 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | PLEASE SEE REVIEW NOTES ON PERMIT | | | 04120942 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2009-10-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-05 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-05 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2009-10-06 13:38:41 | IN ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-03-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-06 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-06 |
Time |
11:46 |
Sent To |
B |
|
| Notes |
| 2008-03-06 11:46:36 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-28 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-28 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
| 2008-02-28 14:39:16 | TO "JWITMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-28 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-28 |
Time |
14:20 |
Sent To |
M |
|
| Notes |
| 2008-02-28 14:20:46 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
09:19 |
Sent To |
M |
|
| Notes |
| 2007-02-02 09:19:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-19 |
Time |
15:57 |
Sent To |
B |
|
| Notes |
| 2006-07-19 00:00:00 | TO "JWITMER" DESK/2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-12 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-12 |
Time |
12:52 |
Sent To |
B |
|
| Notes |
| 2006-06-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-09 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-09 |
Time |
15:42 |
Sent To |
P |
|
| Notes |
| 2006-06-09 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-07 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-07 |
Time |
16:37 |
Sent To |
B |
|
| Notes |
| 2006-06-07 00:00:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-30 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-30 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2006-05-30 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
13:51 |
Sent To |
P |
|
| Notes |
| 2006-05-06 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
14:30 |
Sent To |
B |
|
| Notes |
| 2006-03-24 00:00:00 | TO JW'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
10:02 |
Sent To |
B |
|
| Notes |
| 2005-10-22 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-14 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-14 |
Time |
17:56 |
Sent To |
B |
|
| Notes |
| 2005-10-14 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-04 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2005-10-14 00:00:00 | TO "COMM" BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2005-07-13 00:00:00 | TO "COMM" BD#63 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-16 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | TO "COMM" BD#24/PLANS ON RACK | | 2005-05-16 00:00:00 | IN INCOMING AWAITING SPACE ON "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-26 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-17 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | SENT TO "COMM BD#36 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2009-10-07 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-10-07 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-10-07 |
Time |
17:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-02-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-02-29 |
Time |
08:44 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-02-29 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2008-02-29 08:45:50 | REVISION TO MECH. PLAN PAGE M-3 (PLANS WITH #04120942). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-06 |
Time |
11:59 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-02-06 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2007-02-06 12:00:17 | MECH. REVISION TO PAGES M-2 AND M-3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-20 |
Time |
09:01 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-07-20 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2006-07-20 00:00:00 | *** DENIED *** | | | 1) THE ENERGY CAL'S. NEED TO BE SIGNED | | | AND SEALED BY AN ARCHITECT OR ENGINEER, | | | SEE 2001 FBC 13-600.3.ABC.1.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-19 |
Time |
16:48 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-19 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | *** DENIED *** | | | REVISION TO ENERGY CAL'S. | | | 1) BUILDING PERMIT IS UNDER 2001 | | | BUILDING CODE, SO ENERGY CAL'S. NEED TO | | | BE ON FORM 600A-2001, PER 2001 FBC | | | 13-600.3.A . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-08-19 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-08-19 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-24 |
Time |
08:58 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-01-24 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2005-01-24 00:00:00 | DENIED: | | | 1.ENERGY CALCULATIONS FOR MODEL A & C | | | INDICATE MULTI-FAMILY.ENERGY | | | CALCULATIONS FOR A UNIT SHOWS SINGLE | | | FAMILY.PLEASE CLARIFY.SEE ALSO | | | COMMENT #1 BY JIM WITMER, BUILDING PLAN | | | REVIEW. | | | | | | 2.PROVIDE OUTSIDE AIR CALCULATIONS IN | | | ACCORDANCE WITH 2001 FBC(M)402.2 & | | | 402.2.1 OR TABLE 403.3. | | | | | | 3.AHU'S SHALL BE A MINIMUM OF 4" | | | CLEARANCE AROUND UNIT FOR CONSTRUCTION, | | | SEALING INSPECTION AND MAINTENANCE. | | | | | | 4.DRYER EXHAUST TERMINATION SHALL BE | | | NOON-SCREENED AND EQUIPPED WITH A | | | BACKDRAFT DAMPER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-15 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-15 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2006-08-15 00:00:00 | REVISIONS OK - SHTS P-2 & P-3 CHANGED | | | SANT. AND VENTING FOR W/M, AND SECOND | | | FLOOR BATHROOMS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-12 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-12 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | PLUMBING REVISION DENIED; | | | B-1 SANITARY RISER DIAGRAM, AUTOMATIC | | | CLOTHES WASHER CAN NOT BE INSTALLED AS | | | DRAWN, DOES NOT MEET CODE SEE FBC-2001 | | | SEC. 908.3. A MECHANICAL VENT WILL ONLY | | | WORK UNDER A NEGATIVE PRESSURE, VERTICAL | | | RISERS MAY CREATE A POSITIVE PRESSURE. | | | CLEANOUT SHOULD SHOULD BE INSTALLED AT | | | 48" AFF. | | | ONE SET OF DRAWINGS MARKED IN RED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-05-12 |
Time |
15:21 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-05-12 |
Time |
15:21 |
Sent To |
PC |
|
| Notes |
| 2006-05-12 00:00:00 | SEE NOTES ON PERMIT #04120942 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-09-27 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-09-27 |
Time |
09:53 |
Sent To |
PC |
|
| Notes |
| 2005-09-27 00:00:00 | REVIEW PASSED 8-26-05 BY KEN STEVENS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-06-20 |
Time |
14:51 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-06-20 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2005-06-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATEVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | 2. SHT P-1 INDICATES UNITS C1 & C2, BUT | | | NO PLUMBING FLOOR PLANS OR RISER | | | DIAGRAMS ARE SUBMITTED. PLEASE CLARIFY. | | | SECTION 104.2.1. - NO COMMENT RESPONSE. | | | COMMENT NOT ADDRESSED. | | | 3. SHT P-3 WATER RISER DIAGRAMS. THE | | | WATER HAMMER ARRESTORS ARE REQUIRED ANT | | | THE WASH MACHINE HOT AND COLD WATER, AT | | | THE DISHWASHER, AND AT THE REFRIG. THEY | | | WILL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | | SECTION 604.9 AND PDI-WH 201. - WATER | | | HAMMER ARRESTORS ARE STILL SHOWN IN THE | | | CEILING, AND ARE NOT SHOWN AT THE WASH | | | MACHINE BOX AS REQUIRED. | | | 4. SHT P-3 SANITARY RISER DIAGRAM. APT | | | B1, 2ND BATH, THIRD FLOOR, SHOWER/TUB | | | NOT VENTED. SECTION 901.2.1. - NO | | | COMMENT RESPONSE. COMMENT NOT ADDRESSED. | | | | | | ****************NEW COMMENTS************ | | | 1B. SURVEY SHEETS ARE NOT SIGNED, SEALED | | | & DATED AS REQUIRED PER 61G15-23.002(1) | | | AND FS 471.025. ALSO ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET. FAC | | | 61G15-23.002(2) | | | 2B. SHTS C1.00 THRU C4.00 IF THE DESIGN | | | PROFESSIONAL IS AN ARCHITECT OR ENGINEER | | | LIGALLY REGISTERED UNDER THE LAWS OF | | | THIS STATE REGULATING THE PRACTICE OF | | | ARCHITECTURE OR ENGINEERING, THEN HE/SHE | | | SHALL AFFIX HIS/HER OFFICIAL SEAL TO | | | SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, AS REQUIRED BY | | | FLORIDA STATUTE. SECTION 104.2.2. - ALSO | | | ALL LICENSE NUMBERS, CERT. OF | | | AUTHORIZATIONS, PRINTED NAME OF DESIGN | | | PROFESSIONAL ECT REQUIRED BY FAC & FS. | | | 3B. SEE ATTACHED SHEET CONCERNING THE | | | DESIGN PROFESSIONAL AND FS 553,80(2)(B). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-01-19 |
Time |
08:22 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2005-01-18 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2005-01-19 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ARCHITECT SHALL SHOW THE CERTIFICATE | | | OF AUTHROIZATION ON THE TITLE BLOCK. | | | SEE | | | 61G1-16.004(2) & FS 481.219. | | | 2) SHT P-1 INDICATES UNITS C1 & C2, BUT | | | NO PLUMBING FLOOR PLANS OR RISER | | | DIAGRAMS ARE SUBMITTED. PLEAS CLARIFY. | | | 3) SHT P-3 WATER RISER DIAGRAMS. THE | | | WATER HAMMER ARRESTORS ARE REQUIRED AT | | | THE WASH MACHINE HOT AND COLD WATER, AT | | | THE DISHWASHER, AND AT THE | | | REFRIDGERATOR. THEY WILL BE LOCATED | | | NEAR | | | THE FIXTURE IN AN EFFECTIVE RANGE, NOT | | | IN THE CEILING. SECTION 604.9, AND | | | PDI-WH 201. | | | 4) SHT P-3 SANITARY RISER DIAGRAM. APT | | | B1, 2ND BATH, THIRD FLOOR, SHWR/TUB NOT | | | VENTED. SECTION 901.2.1. | | | 5) SHT P-4 FIXTURE SCHEDULE, W/M SHOWS | | | A | | | 1-1/2" TRAP. MINIMUM 2" TRAP REQUIRED. | | | TABLE 709.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-06-06 |
|
|
Cont ID |
|
| Sent By |
jlong |
Date |
2005-06-06 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
jlong |
Date |
2005-06-06 |
Time |
12:14 |
Sent To |
|
|
| Notes |
|
|