Plan Review Details - Permit 04120944
Plan Review Stops For Permit 04120944
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-01-05 Cont ID  
Sent By alange Date 2005-01-05 Time 14:35 Rev Time 2.00
Received By alange Date 2005-01-05 Time 10:38 Sent To  
Notes
2005-01-05 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT 2 COPIES OF PRODUCT APPROVALS
 FOR NEW EGRESS WINDOW, IMPACT PROTECTION
 AND STRAPS AND TIE-DOWNS.
 ALL PRODUCT APPROVALS REQUIRE THE
 FOLLOWING.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 4.BUILDING VALUATION TOO LOW. IT
 SHOULD REFLECT ALL MATERIALS AND LABOR.
 READJUST VALUE OR WE WILL ACCORDING TO
 MARSHALL AND SWIFTS EXTIMATING GUIDE.
  
 5.FINISH FLOOR IN HABITABLE BUILDINGS
 WITH A MONOLITHIC SLAB REQUIRE FINISH
 FLOOR TO BE A MIN. OF 4" ABOVE GRADE.
 SHOW ON PLANS.FBC WPB AMMENDMENTS
 1807.1.7
  
 6.SUBMIT 2 COPIES OF SITE PLAN SHOWING
 ALL BUILDINGS ON PROPERTY AND
 SEPERATIONS BETWEEN THAM SO THAT
 POSSIBLE TABLE 600 ISSUES CAN BE
 ADDRESSED.
  
 7.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS COMPLYING WITH FBC 2309.6
  
 8.ACCORDING TO 2002 GIS MAPPING NO
 STORAGE BUILDING IS SHOWN AND NO PERMITS
 HAVE BEEN OBTAINED FOR A SHED SINCE
 THEN.PLEASE VERIFY IF EXISTING
 BUILDING HAD A PERMIT.
  
 9.PLEASE SUBMIT 2 COPIES OF ENERGY
 CALCS FORM 600 C. FBC CHAPTER 13
  
 SEE NOTES FROM OTHER REVIEWERS THAT MY
 PREVENT ISSUING OF PERMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-12-28 Cont ID  
Sent By dpalmer Date 2004-12-28 Time 06:26 Rev Time 0.50
Received By dpalmer Date 2004-12-28 Time 06:26 Sent To P
Notes
2004-12-28 00:00:00********* UNSAT ************
  
 1)NOTE: PLEASE SEE IT DOES NOT APPEAR
 THIS PERMIT MAY PULLED AS OWNER BUILDER.
 PAPA INDICATES THIS IS NOT PRIMARY
 RESIDENCE FOR HOMESTEAD. PLEASE SEE
 ATTACHED SHEETS PRINTED FROM PAPA
 SHOWING MULTIPLE HOUSES/UNITS OWNED BY
 THE SAME PERSON W/OUT HOMESTEAD.
 PLEASE SEE OWNER/ BUILDER DISCLOSURE FS
 489. THIS MUST BE PRIMARY RESIDENCE
 ETC.
  
 2)NOTE: PLANS DO NOT INDICATE LOCATION
 OF SERVICE?
 PLEASE SEE 250.32,225.31 ETC . REVIEW
 FOR THIS PART OF CODE COMPLIANCE MAY NOT
 BE DONE AT THIS TIME.
  
 3)NOTE: PLEASE SEE RISER MENTIONS A NEW
 METER/MAIN COMBO, YET RISER INDICATES A
 NEW 250A MAIN DISC?
 PLEASE CORRELATE.
 215.5
  
 4)NOTE: PLEASE SEE RISER IS MISSING
 SEC'S PER 310.15B6,310.16
  
  
 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 6)NOTE: PLEASE SEE 250.66 FOR SIZING OF
 GROUNDING ELECTRODE SYSTEM.
  
 7)NOTE: PLEASE SEE THERE ARE MANY ITEMS
 INDICATED ON PANEL SCHEDULE, YET THESE
 DO NOT APPEAR ON PLANS??
 PLEASE COMPLETE PLANS.215.5
  
 8)NOTE: PLEASE SEE 410.8 FOR LT SHOWN IN
 CLOSET. MIN CLEARENCE REQUIRED.
  
 9)NOTE: PLEASE SEE SD REQUIRED OUTSIDE
 BEDRM IN LIVING RM AREA. NFPA-72
 8-1.4.1.6.2
  
 10)NOTE: PLEASE SEE ZONING COMMENTS FOR
 WHEATHER OR NOT THIS NEW APT UNIT IS
 PERMITTED.
 THIS WOULD AFFECT ELECTRICAL PLANS.
  
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-27 Cont ID  
Sent By mjacobs Date 2004-12-27 Time 08:09 Rev Time 0.00
Received By mjacobs Date 2004-12-27 Time 08:09 Sent To E
Notes
2004-12-27 00:00:00TO "E" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-12-17 Cont ID  
Sent By mjacobs Date 2004-12-17 Time 15:13 Rev Time 0.00
Received By mjacobs Date 2004-12-17 Time 15:13 Sent To Z
Notes
2004-12-17 00:00:00SENT TO "Z" BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2005-01-04 Time   Rev Time 0.00
Received By hmoser Date 2005-01-04 Time 08:42 Sent To B
Notes
2005-01-04 00:00:00DO NOT NEED PERMITS FOR WALL OR WINDOW
 A/C UNITS.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-01-01 Cont ID  
Sent By jleech Date 2005-01-01 Time 06:35 Rev Time 0.25
Received By jleech Date 2005-01-01 Time 06:35 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-12-23 Cont ID  
Sent By mmclean Date 2004-12-23 Time 16:17 Rev Time 0.00
Received By mmclean Date 2004-12-23 Time 16:17 Sent To I
Notes
2004-12-23 00:00:00DENIED, NEED TO PROVIDE TWO COPY OF
 SURVEY SHOWING THE LOCATION OF THE WORK
 WITH SETBACKS.